Loading...
06-2124-014A -40=( WP /GF f , 0 0 8 -23 WP /GF I OA-39 \� V A -39 4 z w QN U n w N n LOAD SERVED +� Y V 4500 zQ Y U LOAD SERVED VA- Q z w ON U N o Q Q } Q Y w Q !L (L 4 50 2 )A-36 A-35 �A -35 � MAS E 2 a- 2 V 6 I i \A -38 \ \FAN W/ LIGHT 1 2 1 \\ 1 �\ � 1 \\ I A . v 1200 \N\ A -38 4 +10 KW HTR CONN. LOAD LESS A/C 10 KW o 1009a REST 40% A/C OR HTN TOTAL DEMAND WATTS AMPS A 240/120 V.1PH3W 39130 A -39 TO SWITCH -3 11892 - 21600 50 2 1480 181 \\ �/ (0 \ �^ A -42 FC -1 6 A -31 0-, A -38 I \\ rn O 20 1 1500 HALLW Y�/ 12 GENERAL LIGHTING 1 8 _� G�,TI 3 8 III 9500 I 50 40 2 I � 10 SPACE 9 101 1 10 / 5000 2 1 30 \ TO FRONT �� ( A -42 (� A -38 4 �\ A -38 11 \ kO A -38 \ I FLOOD LIGHT A -35 \ ON 2ND FLOOR / M,45 / Trz W / \ A -38 - 1 54TH 4 A -411 dVP 1 8 -23 8 -25 WP /GF I 1 0 5 -25 0 WP /GF I A -30 WP /CFI 8 -23 1 � �\\ A -30 A -30 - - - - - -- II `` �- - -A -31 j FAN W/ L ` �� I / �'- �--- �A -31 ��\ I A -30 I I 8 -22 Ll \ FUTURE A -3) I V POOL EQUIP. FAN W/ LIGHT / h 11 I 1 A -31 / FA M i O M 1 / I ,o I ---------------- - - - - -- I / _ JI %'' ; SPRINK ---------------- - - - - -- _ ° PUMP t . ---------------- - - - - -- ---------------- - - - - -- _ r 6 WP /CFI � ---- - -- - - - - - -- -- --- -__ - A -31 I �_ A -30 A -31 �� �� - - - - -- �� WP /GFI /4-' A -31 I A -30 t� COV RED TERR 8 -22 A -29 — — — 8 -22 FAN W/ LIGHT / - - A-28 \ FAN W/ L IGHT� 8 -22 ��� 8 -22 - 0 - - - -- A -29 A- o - A- GF _- TV im ro' HIGH BR�A�ST / -42 42 -42 A -42� WP /GFf A -31 1 6, "fib 6 A -36 / A -36 A -42 O H - A -36 / I I O 1 LIVING ROOM I 1 A -36 \ TO LIVING ROOM LIGHTS % IA-42 TO TRACK \\ 1 A -36 LIGHTING ABOVE 4, r- A -29 A -29 1 1/ 1 A -31 A -41 A_2 I - -- �A -41 -41 A- 8 -�A- 1 I - 0 A -28 \ \ GF /� o I o \ \ 1 A -3 A- 1 1 I A -32 \ / / 0 13,15 0 I A -29 I \ j A -41 A -41 1 I k - KITCi-iE *I� lv - 0 �I�A -41 I 32 I A -31 -- A -31 G I/ _E NG OO''~ I I /A -32 A-2'1 1 _ 1 I WP /GFf -1 - 2 A -20 /A -32 _ - �'A -5,1 / \\ A -41 / 1 �\ -21,29 4A -41 \\ I /':4-4 \ 1 tI I A -28 \ N 1 / /A- - A -60 A -31 U) U- Q V Q aL -1 4 z w QN U n w N n LOAD SERVED +� Y V 4500 zQ Y U LOAD SERVED VA- Q z w ON U N o Q Q } Q Y w Q !L (L 4 50 2 )A-36 A-35 �A -35 � TO LIGHTS AT\1 \ \ CU -1 a- 2 FC -1 6 m 00 'b Q' M 00 108001 2 -31 3000 �\ � STAIR NICHES 1 \ � A . v 1200 N 3 4 +10 KW HTR CONN. LOAD LESS A/C 10 KW o 1009a REST 40% A/C OR HTN TOTAL DEMAND WATTS AMPS A 240/120 V.1PH3W 39130 \' TO SWITCH -3 11892 - 21600 50 2 1480 181 \\ �/ (0 \ AT 2ND OCR FC -1 6 A -31 0-, 31 �� 2 60 rn O 20 1 1500 HALLW Y�/ 12 GENERAL LIGHTING 1 8 _� G�,TI 3 8 III 9500 2 50 40 2 5000 b4 10 SPACE 9 101 DRYER 10 ON 5000 2 1 30 \ TO FRONT �� ( \ (� SPACE 11 12 kO 14 \ I FLOOD LIGHT A -35 \ ON 2ND FLOOR / A -34 40 2 6000 8 COOK TOP A -40 A - 8 1 * 6000 2 40 LAU 15 1 * 14 GENERAL LIGHTING 15 16 15 16 * 1 fir-- -lj --I 20 1 ® \ — -3 32 C -2 I/ A -32 2 A 3 35 � 1 A -32 / \\ V A -33 2 A A- I \\ C -3 ♦\ I 1 ®� \ � I A -32 \ �A -32 8 -1,3 �/ I iBED OM 4 4 1 TA -32 A -33 A -32 I 1 M ELEC. �1,4_32 MI / - - -- A _ -10 "1 \ A -33 \\ 3 1 A -40 A -351 A -35 \ A -35 �9A -35 U 11 �v `� v� j U A -33 1 PNL PNL A -33 A -35 A -33 +A�- WP/GI�I ��R WP /GFI i � 1 \ GFI A -34 W/ LICIT �I / b -- 1 A -134 I / A -40 �A -31 / b' \�i �>/ 5 -21 �� - - -y I / A -34 A -40 / I 0 �� A -40 �' 13 -23 B -23 � WP/GFI 1 I - - - - -- 1 A -22 1 FIST WP/GF' ELEyTFRICAL FLAN SCALE.- 1/4' = 1'-0' Q4 NOTE: ALL OUTLETS, LIGHT RECEPTACLES AND SMOKE DETECTORS IN BEDROOMS SHALL BE ARC FAULT PROTECTED 12 CAR GARAGE %/ 'v� WP /G P /GF f 1 1 / i 1 I / \ I / A -34 % I / I / A -34 5-24 , A�34 WP /GFI ON TIMER O! IN WEATHER PROOF DISCONNECTS NEW U.G. ELEC. SERVICE TYPE : SQUARE'D' QO (OR EQUAL) I AN n n MAIN BUS: 200A SERVICE: RESIDENCE I NEUTRAL: 200A VOLTAGE : 240/12OV. 10 3111. MAIN: LUGS ONLY MOUNTING: SURFACE ALL 20 AMPS, I POLE CKTS, EXCEPT AS NOTED A /C: GARAGE U) U- Q w O Q 0- Q aL -1 4 z w QN U n w N n LOAD SERVED +� Y V 4500 zQ Y U LOAD SERVED W w N B cn Q z w ON U N o Q Q } Q Y w Q !L (L 4 50 2 1480 800 1 8 CU -1 1 2 FC -1 6 m 00 'b Q' M 00 108001 2 60 3000 u 1500 3000 . v 1200 N 3 4 +10 KW HTR CONN. LOAD LESS A/C 10 KW o 1009a REST 40% A/C OR HTN TOTAL DEMAND WATTS AMPS A 240/120 V.1PH3W 39130 39100 10000 10000 11892 11880 21600 50 2 1480 181 8 CU -2 5 6 FC -1 6 10800 2 60 rn O 20 1 1500 12 GENERAL LIGHTING 1 8 +10 KW HTR 8 III 9500 2 50 40 2 5000 b4 10 SPACE 9 101 DRYER 10 ON 5000 2 1 30 SPACE 11 12 GENERAL LIGHTING 14 * 1 15 40 2 6000 8 COOK TOP 13 14 OVEN 8 * 6000 2 40 15 1 * 14 GENERAL LIGHTING 15 16 15 16 * 1 15 20 2 1500 20 1 1500 11 18 12 MICROWAVE 11 18 DISHWASHER 12 1200 1 20 20 1 800 12 DISPOSAL 19 20 REFRIGERATOR 12 1500 1 1 20 * 14 20 1 1500 GENERAL LIGHTING 12 WASHING MACHINE 21 22 GARAGE DR OPENER 12 1000 1 20 * 14 20 1 1500 GENERAL LIGHTING 12 GFI BATH 23 24 GFI BATH 12 1500 1 20 1500 12 20 1 1500 LANDSCAPE LIGHING 12 GFI BATH 25 26 GFI BATH 12 1500 1 20 6000 8 20 1 1500 GATE MOTORS 12 SMALL APPLIANCES 21 28 SMALL APPLIANCE 12 1500 1 20 20 1 1500 12 12 SMALL APPLIANCES 29 30 GENERAL LIGHTING 14 * 1 15 15 1 * 14 GENERAL LIGHTING 31 32 GENERAL LIGHTING 14 * 1 15 15 1 * 14 GENERAL LIGHTING 33 34 GENERAL LIGHTING 14 * 1 15 15 1 * 14 GENERAL LIGHTING 35 36 GENERAL LIGHTING 14 * 1 15 15 1 * 14 GENERAL LIGHTING 31 38 GENERAL LIGHTING 14 * 1 15 15 1 * 14 GENERAL LIGHTING 39 40 GENERAL LIGHTING 14 * 1 15 15 1 * 14 GENERAL LIGHTING 41 42 GENERAL LIGHTING 14 * 1 15 CONNECTED LOAD: SEE LOAD CALC. FEEDER: SEE RISER FED FROM: TYPE : SQUARE'D' QO (OR EQUAL) FA I E L n 5 u MAIN BUS: 150A SERVICE: RESIDENCE I I V NEUTRAL: 150A VOLTAGE : 240/12OV. 10 3111. MAIN: LUGS ONLY MOUNTING: SURFACE ALL 20 AMPS, 1 POLE CKTS, EXCEPT AS NOTED A /C: 10000 A 4 cp O 0- 4 4 Q Y w ON UN w N E3 0) LOAD SERVED O Y V 4500 O U LOAD SERVED w N �d w ON UN 4 4 O Y J cD -� Q o- fL 50 2 1480 800 8 CU -3. 1 2 FC -1 6 m 00 'b Q' M 00 10800 2 (00 3000 u 1500 3000 . v 1200 N 3 4 +10 KW HTR CONN. LOAD LESS A/C 10 KW o 1009a REST 40% A/C OR HTN TOTAL DEMAND WATTS AMPS A 240/120 V.1PH3W 39130 39100 10000 10000 11892 11880 21600 20 1 1500 181 12 GFI BATH, 5 6 GFI BATH 12 1500 1 20 rn O 20 1 1500 12 GENERAL LIGHTING 1 8 TANKLESS WATER 8 cu 9500 2 50 40 2 5000 b4 10 WATER HEATER 9 10 HEATER ON .� 11 12 GENERAL LIGHTING 14 * 1 15 15 1 * 14 GENERAL LIGHTING 13 14 GENERAL LIGHTING 14 * 1 15 15 1 * 14 GENERAL LIGHTING 15 16 GENERAL LIGHTING 14 * 1 15 20 2 1500 12 FUTURE POOL 11 18 SPRINKLER PUMP 12 A 1500 1 20 EQUIPMENT 19 20 15 1 * 14 GENERAL LIGHTING 21 22 GENERAL LIGHTING 14 * I 15 15 1 * 14 GENERAL LIGHTING 23 24 GENERAL LIGHTING 14 * I 15 20 1 1500 12 LANDSCAPE LIGHT 25 26 LANDSCAPE LIGHING 12 1500 1 20 40 2 6000 8 OVEN 21 28 GATE MOTORS 12 1500 1 1 20 29 301 GATE MOTORS 12 1500 1 1 20 CONNECTED LOAD: SEE LOAD CALL. FEEDER: SEE RISER FED FROM: LEGEND ELECTRICAL OUTLET LIGHT RECEPTACLES 1 -WAY SWITCH S® SMOKE DETECTOR ® ELECTRICAL OUTLET 73 3 -WAY SWITCH a EF. EXHAUST FAN FLUORESCENT LIGTH Q ELECTRICAL PANEL ELECT. DISCONNECTOR FLOOD LIGHT Q TELEPHONE JACK 4 TELEVISION JACK HI -HAT Q ELEC. FLOOR OUTLET XFAN W/ LIGHT ITEM PNL A PNL 8 50. FT. 2410 1500 WATTS o 3W /SF. SMALL APPLIANCES COOK TOP OVEN DISHWASHER REFRIGERATOR DISPOSAL POOL EQUIPMENT (FUTURE) DRYER WASHER WATER HEATERS GFI BATH WHIRLPOOL LANDSCAPE LIGHTING CENTRAL VAC SPRINKLER PUMP GATE MOTORS 1230 4500 4500 6000 6000 6000 1200 1500 800 CIA O 1500 5000 1500 m 00 'b Q' M 00 14500 6000 3000 u 1500 3000 . v 1200 N 1500 3000 CONN. LOAD LESS A/C 10 KW o 1009a REST 40% A/C OR HTN TOTAL DEMAND WATTS AMPS A 240/120 V.1PH3W 39130 39100 10000 10000 11892 11880 21600 10800 43492 32680 181 136 TOTAL LOAD ON SERVICE 311A L �4J4 J. Bonfill & Associates U 'd Job: MENDEZ Drawn: H.F. Checked: .O M V 00 M tr) 00 N CIA O � o0 c\ m 00 'b Q' M 00 O -v w o > 00 Cd u m 00 CA �..� . v N O� d1 o rr(u� O [� rn O Cd r__4 cu b4 � m0 ON .� W 'd Job: MENDEZ Drawn: H.F. Checked: .O Scale: V w F� morn m 00 'b Q' M 00 O -v w o > 00 � m 00 CA �..� o � �. 0 G N d1 o O ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF J. BONFILL & ASSOCIATES, INC., AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF J. BONFILL & ASSOCIATES, INC. REVISIONS I BY Date: 12 -5 -06 Job: MENDEZ Drawn: H.F. Checked: J.B.G. Scale: AS SHOWN SHEET OF 2