13-441-056
ELECTRICAL SYMBOL LEGEND POWER EQUIPMENT HIGH VOLTAGE DISTRIBUTION PANELBOARD 277/480V LOW VOLTAGE DISTRIBUTION PANELBOARD 120/208V ® HIGH VOLTAGE PANELBOARD 277/48OV. LOW VOLTAGE PANELBOARD 120/208V. +FJ HD FUSIBLE DISCONNECT OR CIRCUIT BREAKER. NEMA 3R WHEN OUTDOORS. 3 o 3 =N0. OF POLES, 60= SWITCH SIZE, 50 =FUSE, NF =NON - FUSED, ` =FUSE SIZE AS REQUIRED BY LOAD. MOTOR STARTER W /CONTROL XMFR, HOA SELECTOR SW. AND RED PILOT LIGHT. NEMA SIZE BY MOTOR. PROVIDE NEMA 4 ENCLOSURE WHEN OUTDOORS COMBINATION MOTOR STARTER WITH DISCONNECT SWITCH OR CB. SAME Lp ENCLOSURE AND ACCESSORIES AS INDICATED ABOVE © CONTACTOR. SAME ENCLOSURE AND ACCESSORIES AS STARTERS FAN MOTOR "2" WHEN SHOWN INDICATES HORSEPOWER TRANSFORMER POWER DEVICES_ (ALL RECEPTACLES SHALL BE GROUNDING TYPE HOSPITAL GRADE TYPE) DUPLEX RECEPT - 20 AMP NEMA 5 -20R (18" A.F.F.) SINGLE RECEPT - 20 AMP NEMA 5 -20R (18" A.F.F.) DUPLEX RECEPT. MOUNTED ABOVE COUNTER - 20 AMP NEMA 5 -20R (44" A.F.F.) U.O.N. Qj DUPLEX PRECEPT - CRITICAL POWER 20 AMP NEMA 5 -20R 18" A.F.F. (COLOR RED) 04 POWER RECEPT. TWIST LOCK - 20 AMP NEMA 5 -20R (18" A.F.F.) QUAD - PLEX RECEPT - CRITICAL POWER 20 AMP NEMA 5 -20R (18" A.F.F.) 04 QUAD - PLEX RECEPT - 20 AMP NEMA 5 -20R (18" A.F.F.) RE DUPLEX RECEPT FLUSH FLOOR MOUNTED - 20 AMP NEMA 5 -20R DUPLEX RECEPT FLUSH CEILING MOUNTED - 20 AMP NEMA 5 -20R 0i SPECIAL PURPOSE RECEPT (18" A.F.F.) A, B, C A - 250V, 30A, 4W B - 250V, 50A, 4W. C - 25OV, 50A, 5W. JUNCTION BOX & WALL MOUNTED JUNCTION BOX FLOOR MOUNTED JUNCTION BOX UNDER RAISED FLOOR FOR CONNECTION TO WIREMOLD PLUG STRIP MOUNTED AT RACKS AND FURNITURE BY A HARDWIRE FLEXIBLE CONNECTION BY ELECTRICAL CONTRACTOR. I't PULL BOX WIRING / \ BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT. NO TICKS INDICATES 2 #12 CONDUCTORS & 1 #12 GROUND IN 3/4" CONDUIT, TICK MARKS WHEN SHOWN, INDICATES NUMBER OF ##12 CONDUCTORS IF OTHER THAN THREE, I (1) INDICATES GROUND. CONDUIT LARGER THAN 3/4" & CONDUCTOR LARGER THAN #12 SHALL BE AS INDICATED. HOME RUN TO PANEL "A" = PANEL DESIGNATION, 1,3,5 = CIRCUIT NUMBERS. U.O.N. MINIMUM SIZE OF 3 /4 "C AND MAXIMUM OF THREE CIRCUITS PER A -1,3,5 HOMERUN. (DEDICATED NEUTRAL FOR EACH HOT WIRES MUST BE PROVIDED) �J11� FLEXIBLE CONDUIT CONDUIT RUN CONCEALED IN CEILING OR WALLS -U /G - CONDUIT RUN UNDERGROUND OR IN SLAB CONDUIT RUN EXPOSED [ CAPPED CONDUIT -;-;- 1 SYSTEM AND /OR EQUIPMENT GROUNDING CONDUCTOR GROUNDING ELECTRODE AND CONDUCTOR SYSTEM -- x CONDUIT SEAL CABLE TRAY DATA, COMMUNICATIONS AND SECURITY V TELEPHONE L DATA OUTLET (4 "x 4 "x 2 1/2" OUTLET BOX) (18" A.F.F.) M TELEPHONE & DATA OUTLET FLUSH FLOOR MOUNTED Q DATA OUTLET (4 "x 4 "x 2 1/2" OUTLET BOX) (18" A.F.F.) m TELEPHONE OUTLET FLUSH FLOOR MOUNTED Q TELEPHONE OUTLET (4 "x 4 "x 2 1/2" OUTLET BOX)(18" A.F.F.) VW WALL MOUNTED TELEPHONE OUTLET (60 "A.F.F.) UC CLOCK (8' -0" AFF) TERMINAL CABINET - TYPE INDICATED ® TELEPHONE TERMINAL BACK BOARD O CLOSE CIRCUIT TV MONITORS CCTV CCTV CAMERA Q RADIO REMOTE Q PAGER SPEAKER I-fl PHYSIOLOGICAL MONITOR OUTLET rt ROOM RESERVATION SYSTEM. POWERED OVER ETHERNET. IC W INTERCOM STATION (WALL MTD) -3GANG BOX @ 4' -0" IC D INTERCOM (DOOR STATION) SAME AS WALL MTD IC INTERCOM @ 4' -0" A.F.F. c� CATV STATIONS @ 2' -6" A.F.F. (U.N.O.) I� WALL MOUNTED TV OUTLET. Q SECURITY PUSH BUTTON SECURITY DOOR BELL CHIME KP SECURITY SYSTEM KEYPAD CR SECURITY SYSTEM CARD READER SLCURITY SYSTEM UHF CARD READER ® SECURITY SYSTEM MOTION DETECTOR PS SECURITY SYSTEM DOOR STRIKE SECURITY SYSTEM DOOR CONTACT © SECURITY SYSTEM MAGNETIC LOCK 0 POWER SUPPLY �EPO EMERGENCY OFF BUTTON 48 "A.F.F. E5-4 PUSH PLATE (48" A.F.F.) NURSE CALL NCMS NURSE CALL MASTER STATION NURSE CALL STAFF STATION 48" AFF S �/ NURSE CALL DUTY STATION 48" AFF D NURSL CALL TOILET EMERGENCY STATION 48" AFF T t✓ NURSE CALL CODE BLUE STATION 48" AFF T AC� NURSE CALL DOME LIGHT, CEILING MOUNTED GENERAL NOTES: 1. SITE INVESTIGATION: PRIOR TO BIDDING THE CONTRACTOR SHALL VISIT THE JOBSITE AND BECOME ACQUAINTED WITH ALL OF THE EXISTING CONDITIONS WHICH WILL AFFECT HIS WORK. FAILURE TO DO SO WILL NOT BE ACCEPTED AS A REASON FOR REQUESTING EXTRA PAY WHERE THE EXISTING CONDITION RESULTS IN EXTRA MATERIAL. OR LABOR. THE CONTRACTOR SHALL SUBMIT IN HIS BID AN AMOUNT THAT WOULD BE SET ASIDE FOR UNIDENTIFIED ITEMS. 2. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS MANNER AND SHALL BE A COMPLETED AND FULLY OPERATIVE TO THE ACCEPTANCE OF THE OWNER, GENERAL CONTRACTOR AND ENGINEER. 3. THE CONTRACTOR SHALL_ FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE COMPLETE INSTALLATION OF THE ELECTRICAL SYSTEMS, ALL IN ACCORDANCE WITH THESE CONSTRUCTION DOCUMENTS. ALL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2010 AND ALL THE STANDARDS OF CONSTRUCTION ESTABLISHED BY LCH, NFPA CODES INCLUDING, BUT NOT LIMITED TO NFPA 70 - (2006), NFPA 72 (2007), NFPA 99 - (2005), NFPA 110 - (2005), NFPA 101 - (2009), NFPA 760 - (2011), AIA 2010, FGI - (2010) AND OSHA. 4. THIS CONTRACTOR SHALL PAY FOR ALL FEES, INSPECTIONS, TESTS, FINES, ETC., AS REQUIRED. 5. MINIMUM STANDARDS: THE MATERIAL, EQUIPMENT, INSTALLATIONS, AND WORKMANSHIP FURNISHED UNDER THIS SECTION SHALL CONFORM AT LEAST TO THE REQUIREMENTS OF THE REGULATING AGENCIES AS LISTED IN ITEM (3) ABOVE. ALL MATERIALS AND EQUIPMENT USED SHALL BE LISTED OR BEAR U.L. APPROVAL FOR THEIR INTENDED USE. 6. RESPONSIBILITIES: CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A COMPLETE INSTALLATION OF THE RACEWAY SYSTEM, EQUIPMENT AND WIRING IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. GUARANTEE: THE CONTRACTOR /SUB- CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL WORK EXECUTED UNDER THIS CONTRACT SHALL BE FREE FROM DEFECTS OF WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE AND THAT HE, AT HIS OWN EXPENSE, WILL REPAIR OR REPLACE ALL WORK WHICH BECOMES DEFECTIVE DURING THE TIME OF THE GUARANTEE. 8. ALL EQUIPMENT, SYSTEMS AND SYSTEM COMPONENTS SHALL BE FROM THE SAME MANUFACTURER AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS AND SPECIFICATIONS. 9. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL PLANS PRIOR TO ANY FABRICATIONS OR INSTALLATION. 10. OBTAIN FULL INFORMATION REGARDING PECULIARITIES AND LIMITATIONS OF SPACE AVAILABLE FOR INSTALLATION OF THE EQUIPMENT AND MATERIALS UNDER CONTRACT, AND PROVIDE READY ACCESSIBILITY TO ELECTRICAL EQUIPMENT, INCLUDING ANY PART OF SYSTEM REQUIRED TO BE REACHED FOR MAINTENANCE AND OPERATIONS. 11. PROVIDE ACCURATE LAYOUT, GRADES AND ELEVATIONS. TAKE PROPER PRECAUTIONS TO PROTECT WORK AND EQUIPMENT FROM DAMAGE. 12, PROVIDE CODE APPROVED FIRE STOPPING AT ALL CONDUIT PENETRATIONS THROUGHOUT BUILDING CONSTRUCTION TO MAINTAIN FIRE, SMOKE AND SOUND RATING, FIRE SEAL ALL. PENETRATIONS. SEAL TELECOMMUNICATION SLEEVES AFTER CABLES HAVE BEEN INSTALLED. 13. RACEWAYS AND FITTINGS: CONDUIT RUNS SHALL BE CONCEALED IN CEILING SPACES AND WALL PARTITIONS, NO CONDUIT SHALL BE EXPOSED IN INTERIOR SPACES EXCEPT FLEXIBLE CONNECTION TO WIRE MOLDS. CONCEALED CONDUITS ARE TO BE EMT. SURFACE MOUNTED RACEWAYS (WIRE MOLD) ARE TO BE INSTALLED IN SOLID WALLS ONLY. THE MINIMUM CONDUIT SIZE IS TO BE 3/4" FOR THE HOMERUN. ALL CONDUITS AND RACEWAYS SHALL_ BE METAL. 14. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHERS AS WELL AS PROVIDING TEMPORARY POWER. 15. VERIFY EQUIPMENT SIZES, VOLTAGE AND CURRENT CHARACTERISTICS, ETC., BEFORE THE ORDERING OF ANY EQUIPMENT AND PRIOR TO ROUGHING -IN FOR EQUIPMENT TO BE SUPPLIED TO OTHERS, NOTIFY ENGINEER OF ANY CONFLICT. 16. PROVIDE COMPLETE POWER CIRCUIT WIRING AND CONNECTIONS FOR EACH AND EVERY ITEM OF PERMANENT MECHANICAL EQUIPMENT. PRIOR TO ANY ROUGH -IN, COORDINATE WITH HVAC AND PLUMBING EQUIPMENT NAME PLATE TO OBTAIN CORRECT WIRE SIZE AND OVERCURRENT PROTECTION RATING. IF THE NAME PLATE LABEL REQUIRES THE OVERCURRENT PROTECTION DEVICE TO BE FUSES, PROVIDE A FUSED SWITCH WITH PROPER SIZE FUSES AT THE EQUIPMENT LOCATION, 17. CONDUCTOR: ALL CONDUCTOR WIRE AND CABLE SHALL CONSIST OF 98% CONDUCTIVITY COPPER. ALL CABLES SHALL BE SINGLE CONDUCTOR, 600 VOLT, THERMOPLASTIC INSULATION, SUITABLE FOR CONTINUOUS OPERATION AT 75 DEGREES C. CONDUCTOR TEMPERATURE IN BOTH WET AND DRY LOCATIONS. THESE CABLES SHALL BE N F.C. INSULATION CLASSIFICATION TYPE THWN /THHN. MINIMUM SIZE SHALL BE ##12. ALL CONDUCTOR INSULATION SHALL. BE COLOR CODED MAINTAINING THE INTEGRITY OF THE EXISTING INSTALLATION. COLORED INSULATION SHALL BE USED FOR AWG SIZES #10 AND SMALLER AND APPROVED COLOR TAPES SHALL BE USED FOR AWG SIZES #8 AND LARGER. ALL POWER AND CONTROL CIRCUITS SHALL CARRY EQUIPMENT GROUNDING CONDUCTOR SIZED PER NEC 250 -122. 18. THE NATURE OF THIS TYPE OF CONSTRUCTION POSES SPECIAL PROBLEMS FOR THE DESIGN ENGINEER AS WELL AS THE CONTRACTOR. EVERY EFFORT HAS BEEN MADE BY THE ENGINEER TO SHOW AND VERIFY WHERE POSSIBLE THE LOCATION OF THE EXISTING ELECTRICAL SYSTEM THE MAJOR PORTION OF THE ELECTRICAL SYSTEMS ARE AS SHOWN ON THE DRAWINGS. HOWEVER, MINOR DEVIATIONS MAY BECOME EVIDENT AS THE JOB PROGRESSES. NO ADVANTAGE IS TO BE TAKEN BY THE CONTRACTOR BECAUSE OF THESE MINOR DIFFERENCES. 19, CORRECTION OF ANY DEFECTS, REPAIRS OR DAMAGE DURING CONSTRUCTION AS WELL AS ANY MINOR CHANGES IN OUTLET LOCATIONS SHALL BE MADE WITHOUT ADDITIONAL COST. 20. GUTTERS, PULL BOXES, ETC., SHALL BE GALVANIZED STEEL SIZED PER NATIONAL ELECTRICAL CODE, ARTICLE 312, MADE OF MATERIAL SUITABLE FOR THE ENVIRONMENTAL CONDITIONS PRESENT. 21. ALL FLOORS, WALLS AND ROOF PENETRATIONS SHALL BE PROPERLY SEAL-LD -OFF. IF FIRE RATED, AN APPROVED FIRE RETARDANT SEAL SHALL_ BE USED. 22, ALL WIRING SHALL BE IN RACEWAY. A. INDOORS - USE 1 HE FOLLOWING WIRE METHODS: EXPOSED: EMT CONCEAL L.D: EMT CONNECTION TO VIBRATION EQUIPMENT (INCLUDING TRANSFORMERS AND HYDRAULIC, PNEUMATIC, ELECTRIC SOLENOID, OR MOTOR - DRIVEN EQUIPMENT). FMC, EXCEPT IN WET OR DAMP LOCATIONS USE LFMC. DAMP OR WET LOCATIONS: RIGID STEEL CONDUIT. BOXES AND ENCLOSURES: NEMA 250, TYPE 1, EXCEPT AS FOLLOWS: B. DAMP OR WET LOCATIONS: NEMA 250, TYPE 3R STEEL. C. DAMP OR WET LOCATIONS: 250, TYPE 4, NONMETALLIC. UNDERGROUND RNC (SINGLE RUN OR GROUPED). D. SEALING FITTINGS SHALL BE INSTALLED AT FOLLOWING POINTS, AND ELSEWHERE AS SHOWN. WHERE REQUIRED BY THE NEC. WVVV UVY V V VU YVNW V W V t • W V V ♦YIN �GV f V 23. THESE DRAWINGS ARE A GUIDE FOR THE INSTALLATION OF THE RACEWAY SYSTEM AND W I W • EQUIPMENT. THEY ARE INTENDED TO SHOW THE GENERAL ARRANGEMENT, DESIGN AND EXTENT OF THE WORK AND ARE PARTLY DIAGRAMMATIC. THE CONTRACTOR IS -,T v W W W• RESPONSIBLE FOR PROVIDING A COMPLETE AND FUNCTIONAL INSTALLATION. 24. CIRCUIT NUMBERS ARE FOR IDENTIFICATION PURPOSES ONLY. THE CONTRACTOR IS ••` RESPONSIBLE FOR CORRECTLY PHASING THE CIRCUITS IN THE PANEL AND SHALL BALANCE THE LOAD ON THE PHASES UNDER NORMAL OPERATING CONDITIONS. 4WYr PROVIDE TYPE WRITTEN PANEL BOARD DIRECTORIES IN EXISTING PANEL BOARD DIRECTORIES. UPDATE ALL, DIRECTORIES IN EXISTING PANEL BOARDS AFFECTED BY THIS PROJECT ELECTRONICALLY TRACING ALL CIRCUITS. 25, ANY DEVIATION FROM THESE DRAWINGS AND SPECIFICATIONS MUST BE AUTHORIZED IN WRITING FROM THE ENGINEERS OFFICE, THE CONTRACTOR SHOULD BE HELD LIABLE FOR ANY DEVIATIONS WITHOUT SUCH AUTHORIZATION. 26. ALL POWER AND LIGHTING CIRCUITS SHALL HAVE A GREEN EQUIPMENT GROUNDING CONDUCTOR SIZED AS PER NEC 250 -122. NEUTRAL CONDUCTOR SHALL BE 10 AWG (MINIMUM CU -THW) IN ALL MULTI - CIRCUIT BRANCH CIRCUITS. 27. PROVIDE NYLON PULL STRINGS IN ALL EMPTY CONDUITS FOR FUTURE USE 28. COLOR CODING FOR CONDUCTORS: " A. WIRING FOR 120/208 VOLT SYSTEM SHALL BE CODED AS FOLLOWS: PHASE A - BLACK PHASE B - RED PHASE C - BLUE NEUTRAL - WHITE GROUND - GREEN B. WIRING FOR 120/240 VOLT SYSTEM SHALL BE AS FOLLOWS: PHASE A - BLACK PHASE B (HIGH LEG) - ORANGE PHASE C - RED NEUTRAL - WHITE GROUND - GREEN C. WIRING FOR 277/480 VOLT SYSTEM SHALT_ BE CODED AS FOLLOWS: PHASE A - YELLOW PHASE B - BROWN PHASE C - ORANGE NEUTRAL - GRAY GROUND - GREEN D. COLORS ON CONDUCTOR 6 AWG AND SMALLER SHALL BE AN INTEGRAL PART OF INSULATION, ON CONDUCTOR 4 AWG AND LARGER CONDUCTORS, EITHER COLOR CODING TAPE OR PAINTED WITH TWO COATS OF CORRECT COLOR PAINT AT ALL TERMINALS AND CONNECTION POINTS. * UNLESS OTHERWISE REQUIRED BY APPLICABLE CODE. 29. ANY WORK NOT SHOWN OR SPECIFICALLY MENTIONED ON THESE PLANS BUT CONSIDERED NECESSARY FOR COMPLETION OF WORK IN THE PROPER MANNER SHALL BE PROVIDED BY THE CONTRACTOR WITHOUT ADDITIONAL CHARGE. 30. CONTRACTOR SHALL VERIFY SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT, ELECTRICAL CONTRACTOR IS TO COORDINATE HIS WORK WITH THE ARCHITECT BEFORE ROUGH INSTALLATION OF ALL OUTLETS (LIGHTS, RECEPTACLES, SWITCHES, PULL. BOXES, ETC.) FOR EXACT LOCATION. 31. ALL ELECTRICAL EQUIPMENT SUCH AS PANELS, PULL /J- BOXES, FEEDERS, BREAKERS, ETC. SHALL BE PROPERLY IDENTIFIED WITH A PERMANENT LABEL AFFIXED TO THE EQUIPMENT. IDENTIFY BREAKERS IN PANELS BY MEANS OF A TYPED, PLASTIC COVERED DIRECTORY. CONTRACTOR SHALL PROVIDE UPDATED PANEL DIRECTORIES. 32, SPOT PAINT CONDUITS AND BOXES, IDENTIFY CONDUITS WITHIN 6 INCHES (6 ") OF BOX OR ENCLOSURE. USE ONLY COLOR CODE IN COMPLIANCE WITH USER REQUIREMENTS UPON COMPLETION. 33, ALL SERVICE INTERRUPTIONS AND ALL. REMOVAL AND DISPOSAL WORK SHALL BF SCHEDULED AND COORDINATED WITH THE AUTHORIZED REPRESENTATIVE OF THE OWNER. 34. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, - TAXES, INSPECTIONS, TESTS AND OTHER ITEMS AS REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 35. UPON COMPLETION OF THE INSTALLATION, CONTRACTOR SHALL CONDUCT A COMPLETE EQUIPOTENTIAL TEST AS DEFINED IN NFPA 99 4.3.3 (2005). CON FRACTOR SHALL SUBMIT THE RESULTS OF THE TEST TO THE OWNER AND THE A /E. THE CONTRACTOR SHALL_ HAVE TEST EQUIPMENT AVAILABLE FOR SPOT CHECK AT FINAL CONSTRUCTION SURVEY, CONTRACTOR SHALL USE A HAMPDEN OR BENTLEY NEVADA METER OR APPROVED EQUAL. 36. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF PRINTS FOR INDICATING ALL CHANGES AS THE CONSTRUCTION PROGRESSES AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL DELIVER A SET OF AS -BUILT DRAWINGS TO THE OWNER IN REPRODUCIBLE MATERIAL. CONTRACTOR SHALL STAMP AS -BUILT ON THE PLANS (EACH SHEET), PRINT, DATE, AND SIGN IN BLUE INK. 37. CONVENIENCE RECEPTACLE LIGHTING SWITCHES AND WIRING DEVICES MUST BE HOSPITAL GRADE AND SHALL BE ENGRAVED INDICATING PANEL AND CIRCUI T NUMBERS. 38. SEPARATE PERMIT APPLICATIONS ARE REQUIRED FOR FIRE ALARM, BURGLAR ALARM, TELEPHONE, TV, CCTV, COMPUTER WIRING AND ANY OTHER LOW VOLTAGE SYSTEM. COPY OF CONTRACT MUST BE SUBMITTED WITH EACH APPLICATION. 39. FIRE ALARM SHOP DRAWING AND PERMIT SHALL BE PROVIDED BY THE CONTRACTOR. UPON COMPLETION OF THE WORK, THE FIRE ALARM SYSTEM SHALL. BE TESTED AND RE- CERTIFIED. CONTRACTOR MUST HAVE A COPY OF RE- CERTIFICATION AVAILABLE AT FINAL CONSTRUCTION SURVEY. 40. UPON COMPLETION OF ANY NURSE CALL SYSTEM WORK, THE NURSE CALL SYSTEM SHALL- BE TESTED AND RE- CERTIFIED. CONTRACTOR MUST HAVE A COPY OF RE- CERTIFICATION AVAILABLE AT FINAL CONSTRUCTION SURVEY. 41. CONTRACTOR SHALL VERIFY AND PROVIDE NECESSARY CORRECTIVE ACTION TO COMPLY WITH PANELBOARD BONDING PER NEC 517.14. 42. CONDUIT AND BOXES COLOR CODE CHART. ORANGE - CRITICAL BRANCH YELLOW - LIFE SAFETY BRANCH GREEN - EQUIPMENT BRANCH RED - FIRE ALARM 43. WIRING AND GROUNDING IN ALL PATIENT CARE AREAS SHALL BE INSTALLED IN COMPLIANCE WITH NEC ARTICLE 517.13. 44. CONTRACTOR IS RESPONSIBLE FOR REPLACING ALL PARTITION, FLOOR CEILING, CONDUIT PENETRATIONS, AND ANY OTHER EXISTING CONDITION AFFECTED BY THIS PROJECT. UPON COMPLETION, RE -PAINT ALL AFFECTED SURFACES MATCHING SURROUNDING COLOR. 45. TELECOM RACEWAYS, EMPTY BOXES AND PULL STRINGS TO BE INSTALLED BY ELECTRICAL CONTRACTOR. WIRING AND WIRING DEVICES AND FINAL CONNECTION IS TO BE BY OWNER. WWVUV vW V V es WuYau c+ V V LPRO,� No,tZn,� CA 924 V V W u f V U V TM ` 01011 J: WhGUIRRE & ASSOCIATES P.A. 4 �'CONSULTING ENGINEERS 9150° CTUTTI" DADFLAND BLVD. SUITE 900 MIAMI, FLORIDA 33156 ,TLLEPFI x!4(305) 670- -0141 FA: (y05) 670 -0144 y WWi�.11a0 q.rnh1 W f ' Revisions: 0 Z� n L A Q< W a V) �i r� z �< =J nit s <f 0 V) 1 U it +t O C,d Z W LLA Z j"ti � W Z W Z PEKMIT SET DRAWN: AP CHECKED: _NOTE: 1. SYMBOLS IN DASHED LINE INDICATE EXISTING ABBREVIATIONS /SUFFIXES DEVICES. 04 - 19 - 2013 2. ALL SYMBOLS MAY NOT BE USED IN THIS PROJECT. A.F.F. ABOVE FINISHED FLOOR A.F.G. ABOVE FINISHED GRADE AWG AMERICAN WIRE GAUGE BD. BOARD C. CONDUIT CAB. CABINET C.B. CIRCUIT BREAKER CKT. CIRCUIT CCTV CLOSED CIRCUIT TELEVISION CO -THW COPPER WIRE WITH THERMOPLASTIC, HEAT RESISTANT, MOISTURE RESISTANT CHARACTERISTICS E.A. EMPTY CONDUIT E.W.C. ELECTRIC WATER COOLER E EXISTING TO REMAIN ER EXISTING TO BE RELOCATED OR REMOVED EMT ELECTRICAL METALLIC TUBING F.A. FIRE ALARM G.F.I. GROUND FAULT INTERRUPTER GND. GROUND HID HIGH INTENSIVE DISCHARGE HPS HIGH PRESSURE SODIUM I.G. ISOLATED GROUND LT. LIGHT LTG, LIGHTING MCB MAIN CIRCUIT BREAKER MLO MAIN LUGS ONLY MT. MOUNT MTG. HT. MOUNTING HEIGHT N.E.C. NATIONAL ELECTRICAL CODE N.I.C. NOT IN CONTRACT NL NIGHT LIGHT NFPA NATIONAL FIRE PROTECTION ASSOCIATION NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION. LFMC LIQUID TIGHT FLEXIBLE METAL CONDUIT P.A. PUBLIC ADDRESS PNL, PANEL PTZ PAN -TILT -ZOOM CAMERA RECEPT. RECEPTACLE RMC RIGID METAL CONDUIT S.D.B.C. SOFT DRAWN BARE COPPER SW. SWITCH TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION PANEL U.O.N. UNLESS OTHERWISE NOTED V.P. VAPOR PROOF VOC VOLATILE ORGANIC COMPOUND WAP WIRELESS ACCESS POINT W.G. WIRE GUARD. W.P. WEATHER PROOF (NEMA 3R ENCLOSURE) X.P. EXPLOSION PROOF (CLASS TO MEET N.E.C.) LIGHTING FIXTURES O LIGHTING FIXTURE IDENTIFICATION. SEE SCHEDULE 0 HID OR FLUORESCENT DOWN LIGHT a ACCENT TYPE LIGHT FIXTURE a HID OR FLUORESCENT WALL MOUNTED LIGHT FIXTURE RECESSED / LAY -IN MOUNTED FLUORESCENT LIGHT FIXTURE SURFACE OR PENDANT MOUNTED FLUORESCENT LIGHT FIXTURE WALL MOUNTED FLUORESCENT LIGHT FIXTURE F--g� SURFACE OR PENDANT MOUNTED FLUORESCENT STRIP d HID DOWN LIGHT CIRCUIT & EQUIPPED WITH RESTRIKE SYSTEM 01 HID WALL MOUNTED LIGHT FIXTURE LIGHT CIRCUIT RECESSED /FLUORESCENT LIGHT FIXTURE ON EMERGENCY CRITICAL CIRCUIT. SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE ON EMERGENCY CRITICAL CIRCUIT. RECESSED / LAY -IN MOUNTED FLUORESCENT LIGHT FIXTURE ON EMERGENCY LIFE SAFETY CIRCUIT. RECESSED MOUNTED /FLUORESCENT LIGHT FIXTURE ON EMERGENCY LIFE SAFETY CIRCUIT, 9 EXIT LIGHT WALL MOUNTED EXIT LIGHT SHADED QUADRANT INDICATES NUMBER OF FACES. ► -- ARROWS AS SHOWN OR REQUIRED. UNIT EQUIPMENT BATTERY BACKUP EMERGENCY LIGHT + COMBINATION EXIT / EMERGENCY LIGHT WITH BATTERY BACKUP. LANDSCAPE LIGHT FIXTURE O{] POLE MOUNTED SINGLE SITE LIGHTING FIXTURE C7o-� POLE MOUNTED DOUBLE SITE LIGHTING FIXTURE Q CEILING MOUNTED OCCUPANCY SENSOR. INCLUDE POWER PACK AS REQUIRED. ® OCCUPANCY SENSOR POWER PACK. ® LTG. TRANSFER RELAY. S SINGLE POLE SWITCH - 20 AMP (48" A.F.F.) S3 THREE WAY SWITCH - 20 AMP (48" A.F.F.) S4 FOUR WAY SWITCH - 20 AMP (48" A.F.F.) SD DIMMER SWITCH 2000 WATTS 48" A.F.F.) SF FAN SPEED CONTROL (48" A.F.F.) SK KEY OPERATED SWITCH - 20 AMP (48" A.F.F.) SI• SINGLE POLE SWITCH WITH PILOT LIGHT - 20 AMP(48" A.F.F.) Sm MOTOR RATED SWITCH (ONE, TWO OR THREE POLE AS REQUIRED) ST TIME CONTROL SWITCH SOS OCCUPANCY SENSOR SINGLE POLE SWITCH - 20 AMP. (42" AFF). Sos2 OCCUPANCY SENSOR 2 RELAY DUAL TECH SWITCH - 20 AMP. (42" AFF). Sort OVERRIDE SWITCH - 20 AMP. (42" AFF). FIRE ALARM DEVICES n FIRE ALARM PULL STATION (48" A.F.F.) SEMI FLUSH MOUNTED, PROVIDE BREAKABLE GLASS COVER. 04 FIRE ALARM BELL WITH STROBE LIGHT (80 "A.F.F.) ADA FIRE Al -ARM SPEAKER WITH STROBE LIGHT (80 "A.F.F.) ADA 0 FIRE ALARM SPEAKER WITH STROBE LIGHT. CEILING MOUNTED �5 FIRE ALARM MASS NOTIFICATION SPEAKER. CEILING MOUNTED FIRE ALARM STROBE LIGHT - 75 CANDELA MIN. - (80 " A.F.F.) OR 6" BELOW CEILING WHISHEVER IS LOWER, INSTALLATION SHALL COMPLY WITH A.D.A., FIRE ALARM STROBE LIGHT. CEILING MOUNTED ® 24V SMOKE DETECTOR (PHOTOELECTRIC TYPE). ®H SMOKE AND HEAT DETECTOR Q 24V FIXED TEMPERATURE 135° F THERMAL DETECTOR. Q 24V PHOTOELECTRIC DUCT DETECTOR. DH FIRE ALARM DOOR HOLDER IS FIRE ALARM FLOW SWITCH TS FIRE ALARM TAMPER SWITCH F�1CP FIRE ALARM CONTROL PANEL POWER EQUIPMENT HIGH VOLTAGE DISTRIBUTION PANELBOARD 277/480V LOW VOLTAGE DISTRIBUTION PANELBOARD 120/208V ® HIGH VOLTAGE PANELBOARD 277/48OV. LOW VOLTAGE PANELBOARD 120/208V. +FJ HD FUSIBLE DISCONNECT OR CIRCUIT BREAKER. NEMA 3R WHEN OUTDOORS. 3 o 3 =N0. OF POLES, 60= SWITCH SIZE, 50 =FUSE, NF =NON - FUSED, ` =FUSE SIZE AS REQUIRED BY LOAD. MOTOR STARTER W /CONTROL XMFR, HOA SELECTOR SW. AND RED PILOT LIGHT. NEMA SIZE BY MOTOR. PROVIDE NEMA 4 ENCLOSURE WHEN OUTDOORS COMBINATION MOTOR STARTER WITH DISCONNECT SWITCH OR CB. SAME Lp ENCLOSURE AND ACCESSORIES AS INDICATED ABOVE © CONTACTOR. SAME ENCLOSURE AND ACCESSORIES AS STARTERS FAN MOTOR "2" WHEN SHOWN INDICATES HORSEPOWER TRANSFORMER POWER DEVICES_ (ALL RECEPTACLES SHALL BE GROUNDING TYPE HOSPITAL GRADE TYPE) DUPLEX RECEPT - 20 AMP NEMA 5 -20R (18" A.F.F.) SINGLE RECEPT - 20 AMP NEMA 5 -20R (18" A.F.F.) DUPLEX RECEPT. MOUNTED ABOVE COUNTER - 20 AMP NEMA 5 -20R (44" A.F.F.) U.O.N. Qj DUPLEX PRECEPT - CRITICAL POWER 20 AMP NEMA 5 -20R 18" A.F.F. (COLOR RED) 04 POWER RECEPT. TWIST LOCK - 20 AMP NEMA 5 -20R (18" A.F.F.) QUAD - PLEX RECEPT - CRITICAL POWER 20 AMP NEMA 5 -20R (18" A.F.F.) 04 QUAD - PLEX RECEPT - 20 AMP NEMA 5 -20R (18" A.F.F.) RE DUPLEX RECEPT FLUSH FLOOR MOUNTED - 20 AMP NEMA 5 -20R DUPLEX RECEPT FLUSH CEILING MOUNTED - 20 AMP NEMA 5 -20R 0i SPECIAL PURPOSE RECEPT (18" A.F.F.) A, B, C A - 250V, 30A, 4W B - 250V, 50A, 4W. C - 25OV, 50A, 5W. JUNCTION BOX & WALL MOUNTED JUNCTION BOX FLOOR MOUNTED JUNCTION BOX UNDER RAISED FLOOR FOR CONNECTION TO WIREMOLD PLUG STRIP MOUNTED AT RACKS AND FURNITURE BY A HARDWIRE FLEXIBLE CONNECTION BY ELECTRICAL CONTRACTOR. I't PULL BOX WIRING / \ BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT. NO TICKS INDICATES 2 #12 CONDUCTORS & 1 #12 GROUND IN 3/4" CONDUIT, TICK MARKS WHEN SHOWN, INDICATES NUMBER OF ##12 CONDUCTORS IF OTHER THAN THREE, I (1) INDICATES GROUND. CONDUIT LARGER THAN 3/4" & CONDUCTOR LARGER THAN #12 SHALL BE AS INDICATED. HOME RUN TO PANEL "A" = PANEL DESIGNATION, 1,3,5 = CIRCUIT NUMBERS. U.O.N. MINIMUM SIZE OF 3 /4 "C AND MAXIMUM OF THREE CIRCUITS PER A -1,3,5 HOMERUN. (DEDICATED NEUTRAL FOR EACH HOT WIRES MUST BE PROVIDED) �J11� FLEXIBLE CONDUIT CONDUIT RUN CONCEALED IN CEILING OR WALLS -U /G - CONDUIT RUN UNDERGROUND OR IN SLAB CONDUIT RUN EXPOSED [ CAPPED CONDUIT -;-;- 1 SYSTEM AND /OR EQUIPMENT GROUNDING CONDUCTOR GROUNDING ELECTRODE AND CONDUCTOR SYSTEM -- x CONDUIT SEAL CABLE TRAY DATA, COMMUNICATIONS AND SECURITY V TELEPHONE L DATA OUTLET (4 "x 4 "x 2 1/2" OUTLET BOX) (18" A.F.F.) M TELEPHONE & DATA OUTLET FLUSH FLOOR MOUNTED Q DATA OUTLET (4 "x 4 "x 2 1/2" OUTLET BOX) (18" A.F.F.) m TELEPHONE OUTLET FLUSH FLOOR MOUNTED Q TELEPHONE OUTLET (4 "x 4 "x 2 1/2" OUTLET BOX)(18" A.F.F.) VW WALL MOUNTED TELEPHONE OUTLET (60 "A.F.F.) UC CLOCK (8' -0" AFF) TERMINAL CABINET - TYPE INDICATED ® TELEPHONE TERMINAL BACK BOARD O CLOSE CIRCUIT TV MONITORS CCTV CCTV CAMERA Q RADIO REMOTE Q PAGER SPEAKER I-fl PHYSIOLOGICAL MONITOR OUTLET rt ROOM RESERVATION SYSTEM. POWERED OVER ETHERNET. IC W INTERCOM STATION (WALL MTD) -3GANG BOX @ 4' -0" IC D INTERCOM (DOOR STATION) SAME AS WALL MTD IC INTERCOM @ 4' -0" A.F.F. c� CATV STATIONS @ 2' -6" A.F.F. (U.N.O.) I� WALL MOUNTED TV OUTLET. Q SECURITY PUSH BUTTON SECURITY DOOR BELL CHIME KP SECURITY SYSTEM KEYPAD CR SECURITY SYSTEM CARD READER SLCURITY SYSTEM UHF CARD READER ® SECURITY SYSTEM MOTION DETECTOR PS SECURITY SYSTEM DOOR STRIKE SECURITY SYSTEM DOOR CONTACT © SECURITY SYSTEM MAGNETIC LOCK 0 POWER SUPPLY �EPO EMERGENCY OFF BUTTON 48 "A.F.F. E5-4 PUSH PLATE (48" A.F.F.) NURSE CALL NCMS NURSE CALL MASTER STATION NURSE CALL STAFF STATION 48" AFF S �/ NURSE CALL DUTY STATION 48" AFF D NURSL CALL TOILET EMERGENCY STATION 48" AFF T t✓ NURSE CALL CODE BLUE STATION 48" AFF T AC� NURSE CALL DOME LIGHT, CEILING MOUNTED GENERAL NOTES: 1. SITE INVESTIGATION: PRIOR TO BIDDING THE CONTRACTOR SHALL VISIT THE JOBSITE AND BECOME ACQUAINTED WITH ALL OF THE EXISTING CONDITIONS WHICH WILL AFFECT HIS WORK. FAILURE TO DO SO WILL NOT BE ACCEPTED AS A REASON FOR REQUESTING EXTRA PAY WHERE THE EXISTING CONDITION RESULTS IN EXTRA MATERIAL. OR LABOR. THE CONTRACTOR SHALL SUBMIT IN HIS BID AN AMOUNT THAT WOULD BE SET ASIDE FOR UNIDENTIFIED ITEMS. 2. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS MANNER AND SHALL BE A COMPLETED AND FULLY OPERATIVE TO THE ACCEPTANCE OF THE OWNER, GENERAL CONTRACTOR AND ENGINEER. 3. THE CONTRACTOR SHALL_ FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE COMPLETE INSTALLATION OF THE ELECTRICAL SYSTEMS, ALL IN ACCORDANCE WITH THESE CONSTRUCTION DOCUMENTS. ALL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2010 AND ALL THE STANDARDS OF CONSTRUCTION ESTABLISHED BY LCH, NFPA CODES INCLUDING, BUT NOT LIMITED TO NFPA 70 - (2006), NFPA 72 (2007), NFPA 99 - (2005), NFPA 110 - (2005), NFPA 101 - (2009), NFPA 760 - (2011), AIA 2010, FGI - (2010) AND OSHA. 4. THIS CONTRACTOR SHALL PAY FOR ALL FEES, INSPECTIONS, TESTS, FINES, ETC., AS REQUIRED. 5. MINIMUM STANDARDS: THE MATERIAL, EQUIPMENT, INSTALLATIONS, AND WORKMANSHIP FURNISHED UNDER THIS SECTION SHALL CONFORM AT LEAST TO THE REQUIREMENTS OF THE REGULATING AGENCIES AS LISTED IN ITEM (3) ABOVE. ALL MATERIALS AND EQUIPMENT USED SHALL BE LISTED OR BEAR U.L. APPROVAL FOR THEIR INTENDED USE. 6. RESPONSIBILITIES: CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A COMPLETE INSTALLATION OF THE RACEWAY SYSTEM, EQUIPMENT AND WIRING IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. GUARANTEE: THE CONTRACTOR /SUB- CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL WORK EXECUTED UNDER THIS CONTRACT SHALL BE FREE FROM DEFECTS OF WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE AND THAT HE, AT HIS OWN EXPENSE, WILL REPAIR OR REPLACE ALL WORK WHICH BECOMES DEFECTIVE DURING THE TIME OF THE GUARANTEE. 8. ALL EQUIPMENT, SYSTEMS AND SYSTEM COMPONENTS SHALL BE FROM THE SAME MANUFACTURER AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS AND SPECIFICATIONS. 9. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL PLANS PRIOR TO ANY FABRICATIONS OR INSTALLATION. 10. OBTAIN FULL INFORMATION REGARDING PECULIARITIES AND LIMITATIONS OF SPACE AVAILABLE FOR INSTALLATION OF THE EQUIPMENT AND MATERIALS UNDER CONTRACT, AND PROVIDE READY ACCESSIBILITY TO ELECTRICAL EQUIPMENT, INCLUDING ANY PART OF SYSTEM REQUIRED TO BE REACHED FOR MAINTENANCE AND OPERATIONS. 11. PROVIDE ACCURATE LAYOUT, GRADES AND ELEVATIONS. TAKE PROPER PRECAUTIONS TO PROTECT WORK AND EQUIPMENT FROM DAMAGE. 12, PROVIDE CODE APPROVED FIRE STOPPING AT ALL CONDUIT PENETRATIONS THROUGHOUT BUILDING CONSTRUCTION TO MAINTAIN FIRE, SMOKE AND SOUND RATING, FIRE SEAL ALL. PENETRATIONS. SEAL TELECOMMUNICATION SLEEVES AFTER CABLES HAVE BEEN INSTALLED. 13. RACEWAYS AND FITTINGS: CONDUIT RUNS SHALL BE CONCEALED IN CEILING SPACES AND WALL PARTITIONS, NO CONDUIT SHALL BE EXPOSED IN INTERIOR SPACES EXCEPT FLEXIBLE CONNECTION TO WIRE MOLDS. CONCEALED CONDUITS ARE TO BE EMT. SURFACE MOUNTED RACEWAYS (WIRE MOLD) ARE TO BE INSTALLED IN SOLID WALLS ONLY. THE MINIMUM CONDUIT SIZE IS TO BE 3/4" FOR THE HOMERUN. ALL CONDUITS AND RACEWAYS SHALL_ BE METAL. 14. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHERS AS WELL AS PROVIDING TEMPORARY POWER. 15. VERIFY EQUIPMENT SIZES, VOLTAGE AND CURRENT CHARACTERISTICS, ETC., BEFORE THE ORDERING OF ANY EQUIPMENT AND PRIOR TO ROUGHING -IN FOR EQUIPMENT TO BE SUPPLIED TO OTHERS, NOTIFY ENGINEER OF ANY CONFLICT. 16. PROVIDE COMPLETE POWER CIRCUIT WIRING AND CONNECTIONS FOR EACH AND EVERY ITEM OF PERMANENT MECHANICAL EQUIPMENT. PRIOR TO ANY ROUGH -IN, COORDINATE WITH HVAC AND PLUMBING EQUIPMENT NAME PLATE TO OBTAIN CORRECT WIRE SIZE AND OVERCURRENT PROTECTION RATING. IF THE NAME PLATE LABEL REQUIRES THE OVERCURRENT PROTECTION DEVICE TO BE FUSES, PROVIDE A FUSED SWITCH WITH PROPER SIZE FUSES AT THE EQUIPMENT LOCATION, 17. CONDUCTOR: ALL CONDUCTOR WIRE AND CABLE SHALL CONSIST OF 98% CONDUCTIVITY COPPER. ALL CABLES SHALL BE SINGLE CONDUCTOR, 600 VOLT, THERMOPLASTIC INSULATION, SUITABLE FOR CONTINUOUS OPERATION AT 75 DEGREES C. CONDUCTOR TEMPERATURE IN BOTH WET AND DRY LOCATIONS. THESE CABLES SHALL BE N F.C. INSULATION CLASSIFICATION TYPE THWN /THHN. MINIMUM SIZE SHALL BE ##12. ALL CONDUCTOR INSULATION SHALL. BE COLOR CODED MAINTAINING THE INTEGRITY OF THE EXISTING INSTALLATION. COLORED INSULATION SHALL BE USED FOR AWG SIZES #10 AND SMALLER AND APPROVED COLOR TAPES SHALL BE USED FOR AWG SIZES #8 AND LARGER. ALL POWER AND CONTROL CIRCUITS SHALL CARRY EQUIPMENT GROUNDING CONDUCTOR SIZED PER NEC 250 -122. 18. THE NATURE OF THIS TYPE OF CONSTRUCTION POSES SPECIAL PROBLEMS FOR THE DESIGN ENGINEER AS WELL AS THE CONTRACTOR. EVERY EFFORT HAS BEEN MADE BY THE ENGINEER TO SHOW AND VERIFY WHERE POSSIBLE THE LOCATION OF THE EXISTING ELECTRICAL SYSTEM THE MAJOR PORTION OF THE ELECTRICAL SYSTEMS ARE AS SHOWN ON THE DRAWINGS. HOWEVER, MINOR DEVIATIONS MAY BECOME EVIDENT AS THE JOB PROGRESSES. NO ADVANTAGE IS TO BE TAKEN BY THE CONTRACTOR BECAUSE OF THESE MINOR DIFFERENCES. 19, CORRECTION OF ANY DEFECTS, REPAIRS OR DAMAGE DURING CONSTRUCTION AS WELL AS ANY MINOR CHANGES IN OUTLET LOCATIONS SHALL BE MADE WITHOUT ADDITIONAL COST. 20. GUTTERS, PULL BOXES, ETC., SHALL BE GALVANIZED STEEL SIZED PER NATIONAL ELECTRICAL CODE, ARTICLE 312, MADE OF MATERIAL SUITABLE FOR THE ENVIRONMENTAL CONDITIONS PRESENT. 21. ALL FLOORS, WALLS AND ROOF PENETRATIONS SHALL BE PROPERLY SEAL-LD -OFF. IF FIRE RATED, AN APPROVED FIRE RETARDANT SEAL SHALL_ BE USED. 22, ALL WIRING SHALL BE IN RACEWAY. A. INDOORS - USE 1 HE FOLLOWING WIRE METHODS: EXPOSED: EMT CONCEAL L.D: EMT CONNECTION TO VIBRATION EQUIPMENT (INCLUDING TRANSFORMERS AND HYDRAULIC, PNEUMATIC, ELECTRIC SOLENOID, OR MOTOR - DRIVEN EQUIPMENT). FMC, EXCEPT IN WET OR DAMP LOCATIONS USE LFMC. DAMP OR WET LOCATIONS: RIGID STEEL CONDUIT. BOXES AND ENCLOSURES: NEMA 250, TYPE 1, EXCEPT AS FOLLOWS: B. DAMP OR WET LOCATIONS: NEMA 250, TYPE 3R STEEL. C. DAMP OR WET LOCATIONS: 250, TYPE 4, NONMETALLIC. UNDERGROUND RNC (SINGLE RUN OR GROUPED). D. SEALING FITTINGS SHALL BE INSTALLED AT FOLLOWING POINTS, AND ELSEWHERE AS SHOWN. WHERE REQUIRED BY THE NEC. WVVV UVY V V VU YVNW V W V t • W V V ♦YIN �GV f V 23. THESE DRAWINGS ARE A GUIDE FOR THE INSTALLATION OF THE RACEWAY SYSTEM AND W I W • EQUIPMENT. THEY ARE INTENDED TO SHOW THE GENERAL ARRANGEMENT, DESIGN AND EXTENT OF THE WORK AND ARE PARTLY DIAGRAMMATIC. THE CONTRACTOR IS -,T v W W W• RESPONSIBLE FOR PROVIDING A COMPLETE AND FUNCTIONAL INSTALLATION. 24. CIRCUIT NUMBERS ARE FOR IDENTIFICATION PURPOSES ONLY. THE CONTRACTOR IS ••` RESPONSIBLE FOR CORRECTLY PHASING THE CIRCUITS IN THE PANEL AND SHALL BALANCE THE LOAD ON THE PHASES UNDER NORMAL OPERATING CONDITIONS. 4WYr PROVIDE TYPE WRITTEN PANEL BOARD DIRECTORIES IN EXISTING PANEL BOARD DIRECTORIES. UPDATE ALL, DIRECTORIES IN EXISTING PANEL BOARDS AFFECTED BY THIS PROJECT ELECTRONICALLY TRACING ALL CIRCUITS. 25, ANY DEVIATION FROM THESE DRAWINGS AND SPECIFICATIONS MUST BE AUTHORIZED IN WRITING FROM THE ENGINEERS OFFICE, THE CONTRACTOR SHOULD BE HELD LIABLE FOR ANY DEVIATIONS WITHOUT SUCH AUTHORIZATION. 26. ALL POWER AND LIGHTING CIRCUITS SHALL HAVE A GREEN EQUIPMENT GROUNDING CONDUCTOR SIZED AS PER NEC 250 -122. NEUTRAL CONDUCTOR SHALL BE 10 AWG (MINIMUM CU -THW) IN ALL MULTI - CIRCUIT BRANCH CIRCUITS. 27. PROVIDE NYLON PULL STRINGS IN ALL EMPTY CONDUITS FOR FUTURE USE 28. COLOR CODING FOR CONDUCTORS: " A. WIRING FOR 120/208 VOLT SYSTEM SHALL BE CODED AS FOLLOWS: PHASE A - BLACK PHASE B - RED PHASE C - BLUE NEUTRAL - WHITE GROUND - GREEN B. WIRING FOR 120/240 VOLT SYSTEM SHALL BE AS FOLLOWS: PHASE A - BLACK PHASE B (HIGH LEG) - ORANGE PHASE C - RED NEUTRAL - WHITE GROUND - GREEN C. WIRING FOR 277/480 VOLT SYSTEM SHALT_ BE CODED AS FOLLOWS: PHASE A - YELLOW PHASE B - BROWN PHASE C - ORANGE NEUTRAL - GRAY GROUND - GREEN D. COLORS ON CONDUCTOR 6 AWG AND SMALLER SHALL BE AN INTEGRAL PART OF INSULATION, ON CONDUCTOR 4 AWG AND LARGER CONDUCTORS, EITHER COLOR CODING TAPE OR PAINTED WITH TWO COATS OF CORRECT COLOR PAINT AT ALL TERMINALS AND CONNECTION POINTS. * UNLESS OTHERWISE REQUIRED BY APPLICABLE CODE. 29. ANY WORK NOT SHOWN OR SPECIFICALLY MENTIONED ON THESE PLANS BUT CONSIDERED NECESSARY FOR COMPLETION OF WORK IN THE PROPER MANNER SHALL BE PROVIDED BY THE CONTRACTOR WITHOUT ADDITIONAL CHARGE. 30. CONTRACTOR SHALL VERIFY SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT, ELECTRICAL CONTRACTOR IS TO COORDINATE HIS WORK WITH THE ARCHITECT BEFORE ROUGH INSTALLATION OF ALL OUTLETS (LIGHTS, RECEPTACLES, SWITCHES, PULL. BOXES, ETC.) FOR EXACT LOCATION. 31. ALL ELECTRICAL EQUIPMENT SUCH AS PANELS, PULL /J- BOXES, FEEDERS, BREAKERS, ETC. SHALL BE PROPERLY IDENTIFIED WITH A PERMANENT LABEL AFFIXED TO THE EQUIPMENT. IDENTIFY BREAKERS IN PANELS BY MEANS OF A TYPED, PLASTIC COVERED DIRECTORY. CONTRACTOR SHALL PROVIDE UPDATED PANEL DIRECTORIES. 32, SPOT PAINT CONDUITS AND BOXES, IDENTIFY CONDUITS WITHIN 6 INCHES (6 ") OF BOX OR ENCLOSURE. USE ONLY COLOR CODE IN COMPLIANCE WITH USER REQUIREMENTS UPON COMPLETION. 33, ALL SERVICE INTERRUPTIONS AND ALL. REMOVAL AND DISPOSAL WORK SHALL BF SCHEDULED AND COORDINATED WITH THE AUTHORIZED REPRESENTATIVE OF THE OWNER. 34. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, - TAXES, INSPECTIONS, TESTS AND OTHER ITEMS AS REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 35. UPON COMPLETION OF THE INSTALLATION, CONTRACTOR SHALL CONDUCT A COMPLETE EQUIPOTENTIAL TEST AS DEFINED IN NFPA 99 4.3.3 (2005). CON FRACTOR SHALL SUBMIT THE RESULTS OF THE TEST TO THE OWNER AND THE A /E. THE CONTRACTOR SHALL_ HAVE TEST EQUIPMENT AVAILABLE FOR SPOT CHECK AT FINAL CONSTRUCTION SURVEY, CONTRACTOR SHALL USE A HAMPDEN OR BENTLEY NEVADA METER OR APPROVED EQUAL. 36. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF PRINTS FOR INDICATING ALL CHANGES AS THE CONSTRUCTION PROGRESSES AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL DELIVER A SET OF AS -BUILT DRAWINGS TO THE OWNER IN REPRODUCIBLE MATERIAL. CONTRACTOR SHALL STAMP AS -BUILT ON THE PLANS (EACH SHEET), PRINT, DATE, AND SIGN IN BLUE INK. 37. CONVENIENCE RECEPTACLE LIGHTING SWITCHES AND WIRING DEVICES MUST BE HOSPITAL GRADE AND SHALL BE ENGRAVED INDICATING PANEL AND CIRCUI T NUMBERS. 38. SEPARATE PERMIT APPLICATIONS ARE REQUIRED FOR FIRE ALARM, BURGLAR ALARM, TELEPHONE, TV, CCTV, COMPUTER WIRING AND ANY OTHER LOW VOLTAGE SYSTEM. COPY OF CONTRACT MUST BE SUBMITTED WITH EACH APPLICATION. 39. FIRE ALARM SHOP DRAWING AND PERMIT SHALL BE PROVIDED BY THE CONTRACTOR. UPON COMPLETION OF THE WORK, THE FIRE ALARM SYSTEM SHALL. BE TESTED AND RE- CERTIFIED. CONTRACTOR MUST HAVE A COPY OF RE- CERTIFICATION AVAILABLE AT FINAL CONSTRUCTION SURVEY. 40. UPON COMPLETION OF ANY NURSE CALL SYSTEM WORK, THE NURSE CALL SYSTEM SHALL- BE TESTED AND RE- CERTIFIED. CONTRACTOR MUST HAVE A COPY OF RE- CERTIFICATION AVAILABLE AT FINAL CONSTRUCTION SURVEY. 41. CONTRACTOR SHALL VERIFY AND PROVIDE NECESSARY CORRECTIVE ACTION TO COMPLY WITH PANELBOARD BONDING PER NEC 517.14. 42. CONDUIT AND BOXES COLOR CODE CHART. ORANGE - CRITICAL BRANCH YELLOW - LIFE SAFETY BRANCH GREEN - EQUIPMENT BRANCH RED - FIRE ALARM 43. WIRING AND GROUNDING IN ALL PATIENT CARE AREAS SHALL BE INSTALLED IN COMPLIANCE WITH NEC ARTICLE 517.13. 44. CONTRACTOR IS RESPONSIBLE FOR REPLACING ALL PARTITION, FLOOR CEILING, CONDUIT PENETRATIONS, AND ANY OTHER EXISTING CONDITION AFFECTED BY THIS PROJECT. UPON COMPLETION, RE -PAINT ALL AFFECTED SURFACES MATCHING SURROUNDING COLOR. 45. TELECOM RACEWAYS, EMPTY BOXES AND PULL STRINGS TO BE INSTALLED BY ELECTRICAL CONTRACTOR. WIRING AND WIRING DEVICES AND FINAL CONNECTION IS TO BE BY OWNER. WWVUV vW V V es WuYau c+ V V LPRO,� No,tZn,� CA 924 V V W u f V U V TM ` 01011 J: WhGUIRRE & ASSOCIATES P.A. 4 �'CONSULTING ENGINEERS 9150° CTUTTI" DADFLAND BLVD. SUITE 900 MIAMI, FLORIDA 33156 ,TLLEPFI x!4(305) 670- -0141 FA: (y05) 670 -0144 y WWi�.11a0 q.rnh1 W f ' Revisions: 0 Z� n L A Q< W a V) �i r� z �< =J nit s <f 0 V) 1 U it +t O C,d Z W LLA Z j"ti � W Z W Z PEKMIT SET DRAWN: AP CHECKED: PA DATE: 04 - 19 - 2013 SCALE: AS 5HOLUN Sheet Na. 80.00 JOB # 201301 MA D: PA'w'S' P.E. LICENSE r. 52078 Sheet Na. 80.00 JOB # 201301