Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-441-046
NOTE: ALL RATED PENETRATION DETAILS ON TH16 SHT. ARE TO COMPLY WITH UNITED STATES GYPSUM COMPAN' - F-TAI -0 °Of-d HOSPITAL, A- ',�_4:LsTIts:.l ONAL CONSrf�CTION. NOTE: THE DETAILS ON THIS SHEET AfiRE GONSOERED T�I'PIGAL AND AF�,)E NOT NEGESSARIL'4' GALLED OJT ON FLANS HAND500K DATED FEBRUARY i9 '51, REVISED AUGUST 1991. EQUIVALENT DETAIL NUMBERS ARE SHOWN WHERE Af�PLICAFvLE � ;v••� ; ; • V u e • • •s•.• V C:V V•. • • V YvV • • M • I OR 2 HOUR FIRE OR SMOKE WALL 2' 0' (PE U) ACOUSTICAL SEALANT SCREW • u v u • CLIP BACK AND SIDES OF a �— • a w u V v • e • BOX AS NECESSARY C:y v METAL STUD FOR SOUND RATING • • LAi EP AC =ESS F' aNE; + 4' O.C. _ ONE OR TWO LAYERS OF DRYWALL • • u u 5/8' TYPE "X" �•. - AS REQUIRED FOR WALL GONST. — I -i/t' CRC •••b •••€• VVO •MV•• :r ;r - - - - -- ACOUSTICAL SEALANT TAPE AND FIN15H BEHIND CABINET v -- F1RE!RATED cr=*iNG W v FIRE RETARDANT - AROUND BOX PENETRATION TREATED WOOD ^�v v — MAXIMUM 16 $0. IN. STUD$ 51ZED AS REQUIRED FOR PIPING M s v Ar�.I�CENT�J��R ELECTRICAL BOX) =5 U • STU °S 16' O.G. MAXIMUM OPENING rW �• y •. u o u r�• u u u 100 SQ- INA00 S.F. TELEPHONE OR ELECTRICAL BOXES SECTION AT CEILING — LAMINATE BACK PIECE TO WALLBOARD - -- LINER PANEL E -STUD 1 SHALLOW FIVE _SIDE BOX DETAIL L J__ J -fZ NNER SAFING REQUIRED WHERE BOX EXCEEDS 16 $Q, INCHES — — FASTEN TO E -5TUD5 CD STUDS 24' O.G, CHANNEL OR AGGREGATE OF BOXES EXCEEDS 100 5Q. INJ 100 SF OF WALL AREA. , 7 `,' - LABELED ACCESS PANEL IMPALING CLIPS - VARIES =4 ELECTRICAL JUNCTION BOXES J- I�IJNNER eLAN VIEW (2) PER STUD - FASTEN TO E -STUDS SPACE Y WHEN A METALLIC JUNCTION BOX FOR ELECTRICAL RECEPTACLES OR SWITCHES IS CONTAINED WITHIN ELECT. PANEL, F,H-C. OR OTHER - - A RATED WALL OF GYPSUM DRYWALL CONSTRUCTION AND AN OPENING 15 PROVIDED FOR THE BOX IN WALL MOUNTED CABINET � THE SURFACE OF THAT WALL, THE AREA OF THE OPENING MAY NOT EXCEED 16 SQUARE INCHES, UNLE55 — SCREUI5 THE JUNCTION BOX 15 ENCLOSED BY A "5 -SIDED BOX' (SEE APPROVED DETAILS). 1 + + CLIP AT EACH THE AGGREGATE AREA OF ALL SUCH JUNCTION BOXES IN A RATED WALL NOT ENCLOSED BY FUR WALL ABOVE AND BELOW NOTES: STUD 'S -51DED BOXES' DESCRIBED ABOVE SHALL NOT EXCEED 100 SQUARE INCHES IN 100 SQUARE FEET I: GYPSUM BOARD APPLIED VERTICALLY, 5 /G" TYPE "X' OF WALL AREA AS MEASURED FROM FLOOR TO STRCCTURAL DECK OR RATED MEMBRANE. 2. JOINTS TO RECEIVE LIED VERTICALLY, TAPE AND JOINT COMPOUND. JUNCTION 5OXE5 WITH OPENINGS ON OPP051TE FACES OF RATED WALLS SHALL HAVE A HORIZONTAL SEPARATION OF 24 INCHES AS A MINIMUM, REGARDLESS OF BOX SIZE, UNLESS ENCLOSED BY '5 -5IDED BOXES.' LOCATIONS OF STUDS DO NOT HAVE ANY BEARING ON THE ABOVE REQUIREMENTS, NOR DOES THE USE PLAN DETAIL AT SHAFT WAS SECTION PENETRATION RATED PARTIJICIN OF MINERAL WOOL FIRE SAFING ALTER THESE REQUIREMENTS. REF: UL SYSTEM No. 409 EQUIV: TO SKETCH " 206, USG, HANDBOOK EQUIV: TO SKETCH " 101, USG, HANDBOOK -- j TYPICAL JOINT REG2UIREMENTS FOR i HOUR WALL RATED PARTITION PENETRATION DETAIL N.T.S. 3 TYPICAL FIVE SIDE BOX DETAIL RECESSED WALL CABINET DETAILjAGGESS PANEL INSTALLATION DETAIL N.t.s. N.T.S. ON RATED PARTITION FIRE RESISTIVE MATERIAL SECURE ANGLE — r — LESS THAN b" 2' BRACE (I I' MIN, OVERLAP GREATER THAN METAL STUDS FIRE PAMPER SLEEVE F3REAKAWA7 CONNECTION FLOOR OR ROOF SLAB ASSEMBLY ',I I OPTIONAL ------ - - - - -- GUT GYPSUM PANELS TO s OPENING TO BE S FIT DECK GONFIG. 5/8' TYPE 'X' GYP. BD. MATERIAL OF RATING LINED WITH FIRE WOOD STUD EQUAL TO THAT ON -- ONE OR TWO LATER OF DRYWALL ------- - - - - -- 1/4' NOM. GAP FILL RESISTIVE THE WALL (REQUIRED WITH AUOUST, SEALANT BY AHCA) ALTERNATE I: BLOW -OUT ONE n STRAPS WRAPPED AROUND SIDE OF WALL TAPE 4 JOINT RUNNERS - ATTACH WITH METAL STUDS MAY BE COMP. DRYWALL OR SEALANT ANCHORS 2' -0' O.C. USED ON SOME U.L. METAL RUNNERS USED - FIRE RATED ACOUSTIC APPROVED FIRE DAMPER CEILING ASSEMBLY AN IN PLACE OF ALTERNATE 2: FIRE DAMPER ANGGLE LE IRON RON FRAMES, CHANGE OF G I IN H I HT AT T CEILING SLEEVE — I FACE 70 SE SEALED WITH CONTINUOUS STEEL STUDS �— I' MIN. OVERLAP DRYWALL, SEALANT, OR TAPE (16' / 24' DG.) BREAKAWAY AND JOINT COMPOUND CONNECTION OPTIONAL LINING OF NOTE: S OPENING: LOCAL OVER I' GAP REQUIRES A SECURE WITH FIRE RE515tIVE tMTAL ,STU© AUTHORITIES MAY REQUIRE BLOW-OUT PATCH CEILING MATERIAL OF RATING OPENING TO BE LINED ACOUSTICAL SEALANT BRACE EQUAL TO THAT ON THE PAC< WITH -91 METAL STUDS WALL FOR SOME FIRE SANNG AT MANUFACTURED METAL RUNNERS - ATTACH WITH PAMPER INSTALLATION. ANCHORS 2' -0' O.G. DAMPER REQUIRED (NOT REQ'D. BY AHCA) DENSITY WITH NO VOIDS r f FIN. FLOOR I" MIN. OVERLAP OR GAPS / (FIRE ONLY) f�` �''" FIRE DAMPER SLEEVE f DUCT BREAKAWAY YI-4— SECTION A -A ONE HOUR_IUAL� CONNECTION -rte AL TERNATE 1 OR 2 MAY BE USED ON EItHER SIDE OF WALL. 5/8' THPE 'X" GYP. BD. � ONE 51DE OF PENETRATION MAY REMAIN OPEN. F, CONCRETE OR MASONRY =q==m - , --FIRE RATED 5ECTIDN CEILING ASSEMBLY NOTE: N.T.S. ASS M Y TRANS NON RATED SPECIFIC FRAMING REQUIREMENTS OF OPENINGS NOTES: CEILING ASSEMBLY SHOULD BE PROVIDED IN THE ARCHITECTURAL I. JOINTS MAY BE CEG5iTE IF SAFEING 15 USED IN CAVITY. TEST REF: REF: GEG B -II -83 GEG 5 -9 -84 T- 3362 -05U AND STRUCTURAL DRAWINGS THAT ARE SUBMITTED T- II14 -06U NOTE: 2 LAYERS 5/8' TYPE 'x' DRYWALL FOR BUILDING PERMITS. REF: UL SYSTEM No. WL 1065 2. JOINTS IN FIN15H LAYER TO RECEIVE TAPE AND JOINT COMPOUND GA -WP -1200 AT 2 HOUR RATED CEILING ASSEMBLY BULKHEAD AT ONE -HOUR DAMPER SLEEVE INSTALLATION DETAIL N.t.s. ��MULTII-LE PIPE PENETRATION DETAIL N.T.S. �] HORIZONTAL 5U6F JOINT REQUIREMENTS N.T.S. I0 SM ©ICE � ONE -HOUR PARTITION DETAIL N.T.S. RATED CEILING; ASSEMBLY N.t.S. A OV SUSPEND D CE I INC-cS (rEkrENDicuLAr� To DECK) STRUCTURE ABOVE MEMBRANE FLOOR OR ROOF SLAB ASSEMBLY DECK I HR RATED r. MAX. 2' FILL VOIDS. SEE DETAIL 16 NEW 5/8' TYPE 'X' w PIPINGS AND /OR CONDUIT NEW STUD EXTEN51ON Q — REMOVE EXIST. :f SCHEDULE DRYWALL PIPING TIGHTLY FILL VOIDS AT METAL CEILINGS w PECK WITH SAFING MATERIAL - I 5 /S' TYf � 'X' GYP&UM "' i u - RATED CEILING A/C DUCT 4 */CF DEN I,UALLBOARD AT RATED 5/8' CSYPSUM BOARD ALL DRYWALL RUNNERS - ATTACH WITH PARTITIONS h NOTE: ANCHORS 2' -0' O.G. OVER 3 5/S' METAL STUDS � �" _ DRYWALL JOINTS �`� _ ELECTRICAL CEILING STAGGERED 518' TYPE "x" - CL SIDES BY MIN, 12' CONTINUOUS STEEL STUDS RED• H05E EX15TING WALL REMOVE EXIST. I8" Id' I8' (I6' / 24' O.G.) CABINET/ HEAD TRACK CLEA CLEA CLEA ELECTRICAL/ SAFING AS REQUIRED TELEPHONE PANELS X� TEND EXISTING WALL. 2 H - WA TH U I H . A55'Y. A/C DUCT TO DECK FOR I HR WALL (SHAFT WALL SIMILER) RECESSED LIGH FI TURE ACOUSTICAL SEALANT DECK (SHAFT CEILING -- GUNNERS - ATTACH WITH I ANCHORS 2' -0' O.C. CLIP — FIN. FLOOR IN I RA RATED 2 PER STUD EXTRA WIDE WALL SPADE ROOM CORRIDOR ROOM I HR RATED + MEMBRANE - - -� - -ALL DYRPEALL - - - 5 GE TIRI RATED WALL N.T.S. NOTE: FURRING - -- TEST REF: REFER TO 1 /6' FLOOR PLAN FOR EXACT LOCATIONS SATED CHASE WALL THRU I HR- CLG AS5'Y. FU}2RED WALL T- 3362 -051.1 F. E. CABINET T- II14 -05U GA -WP -1200 �I SMOKE 4 ONE -HOUR PARTITION DETAIL N.T.S. �2 EIRE EXTINGUISHER CABINET /ELECTRICAL/ N.T.S. I3 PARTITION O HOR RATED MEMBRANEAIL OF N.T.S. �� EQUIPMENT CLEARANCE DETAIL N.T.s. Imo✓ — N.T.s. (I`ERPENDIGULPtTOPECK) TELEPHONE /PANELS SECTION loo N.T.5, N.T.S. 18 N.T S. I g N.T.S. 2 0 N.T.S. Revisions: 0 z O � N 0i I �< z Q•' Fr 0 O N Y 0 I m u 0 RS A LAj Cie rmir V) z z A 0 �- z a z W a." PERMIT SET DRAWN: RR CHECKED. LEN DATE: 04 -19 -2013 SCALE: A5 SHOWN SEAL. ........ . , , . ..T (� "" . ... r . �. Sheei No. A -20 OF 20 JOB # 201301 l