13-441-025S I XTi� fL00fR
FL 00fR FLAN_
SG,ALE: 1/8" = V -0"
Ff p"OF1015ED
NORTH
r�
FL_00'` -uD
W`•`�
V V V
CHECKED:
GONTRO!_
rrr rrr Frr wrw
WALL OR PARTITION
�
(SEE PARTITION TYF, S)
ONE H'7tIR TKE /SM:XE'wATED
err I rn� i w+ i rrw C wwM
�JyaL'L Orr FhRT�Tl00.1 • y
"
(SEA �-
T O H`b F-,RE /SNv,:E RATED
rir: I I rw i rirr I l l�l
WALL OR PARTITION
(SEj E PARTITION TYPFS)
PAf;,P IZION,T'C7UNDEf-,t�iCIE OF
1- " 1+
STR! ItTURE FOR SEGJRIT� REA5ON5
DRYWALL L30T+', 5056 NOT RATE
EXISTING 5'x 5' STEEL COLUMN
NEW REINFORCED CONCRETE
COLUMN OR CONCRETE WALL
(5 F ARCH. t 5TRUCTURA
_
NEW CONCRETE BLOCK WALL
(SEE FLOOR PLANS)
NEW METAL STUD PARTITION
--
(SEE FLOOR PLANS AND
(fAS11 TI N TYPE DETAILS)
EXISTING REINFORCED CONC.
Lj
COLUMN OR CONCRETE WALL
(BEE ELOOS PLANS)
EXISTING WALL OR'
PARTITION TO REMAIN
WALL OR PARTITION
WITH NEW DOOR AND DOOR NUMBE
(COORDINATE W/ DOOR SCHEDULE)
NOTE:
BROKEN LINE DOOR INDICATES
DOUBLE ACTING DOOR
WALL OR PARTITION WITH
EXISTING DOOR TO REMAIN
INDICATES
NEW FOLDING PARTITION
ROOM NUMBER SYMBOL
123
(REFER TO ROOM FINISH SCHEDULE)
STOREFRONT / WINDOW OR
O
BORROWED LIGHT 5YM50L
(SEE ELEVATIONS)
LOUVER SYME30L
(SEE ELEVATIONS)
—
CABINET 5YMBOL
(SEE ELEVATIONS)
PARTITION TYPES SYMBOL
8
(REFER TO PARTITION
TYPE DETAILS AND NOTES)
INTERIOR ELEVATION SYMBOL
<2>
(SEE INTERIOR ELEVATIONS)
ELEVATION MARKS
(HATCHING DENOTES NEW)
(UNHATCHED DENOTES EXISTING)
I
SECTION SYMBOL
A-
W/ DRAWING AND SHEET NUMBERS
DETAIL 5YMB0L
A-
W/ DRAWING AND SHEET NUM1 ER5
�\
REVISION SYMBOL
(REFER TO COVER SHEET
FOR REVISION INFORMATION)
OUT OF SCOPE OF WORK
SHIELDING RECOMMENDATION:
WALL A - ADJACENT TO CORRIDOR, SECONDARY BARRIER,
LEAD SHIELDING 1116"
WALL A - ADJACENT TO CORRIDOR, PRIMARY BARRIER,
LEAD SHIELDING I/V
WALL B - ADJACENT TO WORK AREA, FUTURE X -RAY
LEAD SHIELDING I /16'
WALL C - ADJACENT TO CORRIDOR, LEAD SHIELDING I/16"
WALL D - ADJACENT TO CONTROL RM. LEAD SHIELDING 1116"
WALL E - ADJACENT TO DICTATION ROOM
LEAD SHIELDING 1116'
WALL F - ADJACENT TO CORRIDOR. LEAD SHIELDING 1/16"
WALL G - ADJACENT TO VIEWING ROOM
LEAD 5HIELDING I /16'
WALL H - ADJACENT TO E.W.H. d STORAGE CLOSET
LEAD SHIELDING 1116'
WALL I - ADJACENT TO CORRIDOR. LEAD SHIELDING
X -RAY
RR
CHECKED:
GONTRO!_
DATE:
•
��631
AS SHOWN
D
C+
631
A
5T IUC;<Y 11
I
G-
�H
LEAD SHIELDING PLAN
SCALE, 3AW - I' -I' --
N
dypp
< W
G O
1--4
F�1
C)
y�:E
Mai
!F-4
1+1
O
� U
u ,11
w1
O (d I
z LLJ
0
fi ^ z
o Z
LL. oG A
z
X
V
PERMIT SET
DRAWN:
RR
CHECKED:
LEN
DATE:
04 -19 -2013
SCALE:
AS SHOWN
SEAR"
s co , �#
4Y ..... r
Sheet No.
A -2
Of
20
liols# 201301