Loading...
13-441-002_ 1 ! r �' V 9, H p f A L GENERAL NOTES I. CONTRACTOR IS BEING PROVIDED WITH COMPLETE SETS OF DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUBCONTRACTORS WITH COMPLETE SETS OF DRAWINGS, INTENT IS FOR ALL SYSTEMS AND EQUIPMENTS TO BE PROVIDED WITH UTILITY CONNECTIONS AS REQUIRED FOR OPERATION. EXAMPLE, IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS, AND THE PLUMBING PLANS DO NOT SHOW A WATER OR DRAWING CONNECTION, THE ENGINEER WILL PROVIDE THE DESIGN DETAILS IN ACCORDANCE WITH THE DESIGN CRITERIA FOR THE REST OF THE INSTALLATION, CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE CONNECTION AT NO ADDITIONAL COST TO THE OWNER. 2. CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE DURING THE BIDDING PERIOD, AND VERIFY THAT CONDITIONS ARE AS DESCRIBED IN THE DOCUMENTS. DISCREPANCIES ARE TO BE NOTED IN WRITING, AND ARCHITECT /ENGINEERS, NOTIFIED. CONTRACTOR ACCEPTS CONDITIONS AS THEY ARE ON THE SITE, AND MUST PROVIDE SYSTEMS AND WORK, AS DESCRIBED IN THE CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER. 3. DIMENSIONS PROVIDED ARE NOMINAL NOT ACTUAL. THEY TAKE AS A BASIS EXISTING WALLS. IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT IMMEDIATELY FOR COORDINATION. IF CONTRACTOR PROCEEDS, HE DOES SO AT HIS OWN RISK, AND IS RESPONSIBLE FOR ALL EXPENSES INCURRED, IF AT THE DISCRETION OF THE OWNER OR Tl-F- ARCHITECT THE WORK HAS TO BE RE -DONE, 4. SHUTDOWN OF UTILITIES; IF A SHUTDOWN OR ANY TYPE OF INTERFERENCE WITH EXISTING SYSTEMS IS ANTICIPATED, THE CONTRACTOR MUST NOTIFY THE OWNER 72 HOURS IN ADVANCE, AND OBTAIN APPROVAL IN WRITING PRIOR TO PROCEEDING, 5. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS, AND USE ALL APPROPRIATE CONSTRUCTION METHODS /TECHNIQUES TO PROTECT EXISTING UTILITIES AND OTHER PROPERTY NOT NOTED FOR REMOVAL. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES INCURRED DURING CONSTRUCTION, AND SHALL REPAIR ANY DAMAGES AT NO EXPENSE TO THE OWNER. 6. IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE CONTRACTOR SHALL OBTAIN CLARIFICATIONS DURING THE BIDDING PERIOD. IF THE DISCREPANCY COMES UP DURING THE CONSTRUCTION, IT IS ASSUMED THE CONTRACTOR BID THE MOST EXPENSIVE WAY, AND WILL DO THE WORK AS PER THE DIRECTIONS OF THE OWNER / ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. 7. ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COMMON USE, ARCHITECT WILL DEFINE INTENT OF ANY IN QUESTION. 8. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER EQUIPMENTS TO PROTECT THE SAFETY OF ALL PERSONS AND THE PROPERTY THROUGHOUT THE ENTIRE PERIOD OF THE CONSTRUCTION CONTRACT. 9. THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENTS WITH SUBCONTRACTORS, AS WELL AS SHOP DRAWINGS AS APPROVED BY ARCHITECT, BEFORE PROCEEDING WITH THE WORK. 10, ALL ITEMS USED IN CONSTRUCTION, BUT NOT SPECIFICALLY MENTIONED HEREIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE ORDINANCES AS TO APPLICATION AND USE, II. PROVIDE ELECTRIC INSULATION BETWEEN ALL DISSIMILAR METALS AND ALSO BETWEEN CEMENT AND METAL. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS TO COMPLETE THE PROJECT. 13. CONTRACTOR TO REVIEW ALL EXISTING BUILDING SYSTEMS, AS TO THEIR COMPLIANCE WITH ALL LOCAL AGENCY REQUIREMENTS, AND BRING ANY NON - CONFORMING ITEMS TO ARCHITECT'S AND ENGINEER'S ATTENTION, 14. GENERAL CONTRACTOR IS TO PROTECT EXISTING ADJACENT AREAS WHERE WORK IS TO BE PERFORMED, ANY EXISTING MILLWORK OR EQUIPMENT DAMAGED DUE TO WORK PERFORMED, SHALL BE REPAIRED /REPLACED TO MATCH EXISTING (TYPICAL UNLESS OTHERWISE NOTED). 15. DRAWINGS ARE SCHEMATIC, SNOWING RELATIVE LOCATIONS AND CONNECTIONS, AND SHALL NOT BE SCALED AT ANY TIME. 16. ALL WOOD BLOCKING WITHIN BUILDING STRUCTURE, SHALL BE FIRE - RETARDANT TREATED AS PER SPECIFICATIONS. 17. GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING RATED WALLS /PARTITIONS WITHIN SCOPE OF WORK AREA, CONTRACTOR SHALL UPGRADE EXISTING PARTITIONS AS REQUIRED TO MAINTAIN THE INTEGRITY OF THE DESIGNATED RATING. 18, ELEVATIONS AND LEVELS, A. ALL NUMERICAL ELEVATIONS AWE TO TOP OF CONCRETE SLAB. UNLESS NOTED OTHERWISE. 19, ALL INTERIOR GYPSUM WALL BOARDS ARE 5/8' TYPE "X" G.W.B. ON METAL STUDS OR FURRING CHANNELS, UNLESS NOTED OTHERWISE. SIZES AS DIMENSIONE=D ON FLOOR PLANS. SEE NOTE NUMBER "9' FOR LOCATION OF WATER RESISTANT G.W.B. 20. PROVIDE WATER RESISTANT TYPE 'X" G.W.B. IN ALL TOILETS AND JANITOR'S CLOSETS. 21, BEFORE PATCHING A; ,Y FIRE- 12ATED C.M.U, PARTITION, FILL ANY EXPOSED CELLS SOLID WITH GROUT. 22. PROVIDE FINISH WALL UNDER AND BEHIND ALL EQUIPMENTS AND CASE WORK. 23, LOCATION AND SIZE OF CEILING AND WALL ACCESS PANELS SHALL BE DETERMINED BY THE POSITION OF VALVES AND OTHER MECHANICAL AND ELECTRICAL ITEMS WHICH REQUIRE ACCESS. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES. THE ARCHITECT SHALL REVIEW AND APPROVE ALL FINAL LOCATIONS OF ACCESS PANELS PRIOR TO INSTALLATION. 24. THERE SHALL BE NO BACK -TO -BACK ELECTRICAL TELEPHONE OR OTHER OUTLETS. 25, ALL VERTICAL PIPING AND COLUMNS EXPOSED IN ROOMS, SHALL BE FURRED WITH METAL STUDS AND DRY WALL, AND FINISF -,ED TO MATCH ADJACENT WALLS, U.N.O. EXCEPTIONS, A. ELECTRIC CLOSETS C. MECHANICAL ROOMS B. TELEPHONE CLOSETS D. STAIRS 26, WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE, AS REQUIRED TO PROVIDE ADEQUATE SUPPORTS, ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE S.T.C. MATERIAL. 27. SEE INTERIOR ELEVATIONS FOR FINISHES AND FINISH DETAILS FOR INTERIOR SPACES. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR ACOUSTICAL TILE FINISH. 28. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF CEILING - MOUNTED MECHANICAL /ELECTRICAL FIXTURES, 29, STAGGER JOINTS VERTICALLY AND HORIZONTALLY IN ALL G.W.B. PARTITIONS, EACH SIDE, JOINTS STAGGERED MINIMUM 2' -0" U.O.N. 30. CONTRACTOR SHALL CONFIRM THAT ALL EXISTING EXPOSED STEEL COMPLIES WITH N.F.P.A. FIRE PROTECTION REQUIREMENTS, CONTRACTOR SHALL PROVIDE ALL NECESSARY INSULATION /FIRE PROTECTIVE COATINGS. 31. CONTRACTOR TO SUBMIT ALL SHOP DRAWINGS TO ARCHITECT AND THE BUILDING DEPARTMENT FOR APPROVAL, (ELEVATOR, TRUSSES, WINDOWS, ETC.) 32, CONTRACTOR REQUIRED TO PULL SEPARATE DEMOLITION PERMIT. i'1 1. '7000 BLDG OFIC RENOVATION LARX1.`kkT COMMINITY HOSPITAL 7000 S.W. 62thAVE ! SOUTH MIAMI, FLORIDA 33143 TEL: (305) 284-7500 � FAX: (305) 284 -7545 EB00009r LOUIS J. AGUIRRE & ASSOCIATES PA. CONSULTING ENGINEERS 9150 SOUTH DADELAND BLVD. SUITE 9) MIAMI, FLORIDA 3316 TELEPHONE: (305) 670 -0141 FAX: (305) 670 -0144 E -MAIL ADDRESS: GRALMAIL@LJAAPA.COM APRIL 1, 2013 L rj JA a a r c h i t c it S FLORIDA LICENSE *AA0002689 2100 Ponce de Leon Blvd. Suite 1170, Coral Gables, Florida 33134 Tch (305)265 -7177 Fax: (305)262 -$435 LUIS E. NAYA• A1.A FL AR0008063 PROJECT NUMBER: 201301 INJEX OF CITY MAP LIFE SAFETY c + MO.00 SYMBOL LEGEND AND GENERAL NOTES - MECHANICAL LS -1 SIXTH FLOOR LIFE SAFETY PLAN. M3.00 SIXTH FLOOR PLAN, DEMOLITION - HVAC "A" ak M3.01 SIXTH FLOOR PLAN AREA - HVAC ARCHITECTURAL ;ISM € s AREA "B" - HVAC n a M6.01 SCHEDULES - HVAC A -1 DEMOLITION PLAN, LEGEND AND N01 M7.00 �� Salt V ((��N t JA Mfi i♦il w ( }.rd.c3f Iii 4 J A -2 SIXTH FLOOR PLAN, AREA "A ", LEGE AND NOTES. Ta .. DETAILS - HVAC A -3 PARTIAL 5TH FLR., 7TH FLR., ROOF M7,02 CONTROLS -HVAC �• I A -4 SIXTH FLOOR EQUIPMENT PLAN, AR "A ". LEGEND AND NOTES. ELECTRICAL A -5 SIXTH FLOOR EQUIPMENT PLAN, ARE'B ", LEGEND AND NOTES. EO.00 SYMBOL LEGEND AND GENERAL NOTES - ELECTRICAL A -6 SIXTH FLOOR CEILING PLAN, AREA ", LEGEND AND NOTES, E0.01 LIGHTING FIXTURE SCHEDULE AND LIGHTING CONTROL DETAILS - ELECT. A -7 SIXTH FLOOR CEILING PLAN, AREA "1 LEGEND AND NOTES. c, SIXTH FLOOR PLAN DEMOLITION - ELECTRICAL A -8 SECTIONS, LEGEND AND NOTES. E3.01 SIXTH FLOOR PLAN AREA "A" LIGHTING - ELECTRICAL A -9 INTERIOR ELEVATIONS E3.02 SIXTH FLOOR PLAN AREA "I" LIGHTING - ELECTRICAL A -10 INTERIOR ELEVATIONS E3.03 SIXTH FLOOR PLAN SI E3.04 SIXTH FLOOR PLAN ^y A -11 INTERIOR ELEVATIONS E3.05 y* AREA "A" SYSTEMS - ELECTRICAL A -12 TYPICAL CARINET DETAILS hi SIXTH FLOOR PLAN AREA "B" SYSTEMS -- ELECTRICAL v PR0JEC SITE I� POWER RISER DIAGRAM - ELECTRICAL A -14 ROOM FINISH SCHEDULE NOTES AND NAILS E5.01 FIRE ALARM RISER DIAGRAM - ELECTRICAL A -15 DOOR SCHEDULE. NOTES AND DETAIL E5.02 SYSTEMS RISER DIAGRAM - ELECTRICAL L -16 PARTITION TYPES, %TOTES AND DETAI >S s) PANEL SCHEDULES - ELECTRICAL A -17 TYPICAL CEILING DETAILS - CONTINV. E6.01 PANEL SCHEDULES - ELECTRICAL A -la MISCELLANEOUS DETAILS. E7.00 SYSTEMS RISER DIAGRAM - ELECTRICAL A -19 PENETRATION AND FIRE RATING DETi.S. PLUM tI ING J Jitl.°S,r'„ ff A -20 PENETRATION AND FIRE RATING DETLS. 7 i PO.00 SYMBOL LEGEND AND GENERAL NOTES - PLUMBING ! P3.00 SIXTH FLOOR PLAN, i' AREA MAP SIXTH FLOOR PLAN AREA "A" DRAINAGE - PLUMBING n�, P3.02 SIXTH FLOOR PLAN AREA "B" DRAINAGE - PLUMBING P3.03 SIXTH FLOOR PLAN AREA "A" DOMESTIC WATER -- PLUMBING P3.04 SIXTH FLOOR PLAN AREA "B" DOMETIC WATER - PLUMBING P5.00 SIXTH FLOOR PLAN SANITARY ISOMETRIC -- PLUMBING P5.01 SIXTH FLOOR PLAN DOMESTIC WATER ISOMETRIC - PLUMBING P7.00 DETAILS - PLUMIRING P7.02 DETAILS - PLUMBING BUILDING I REVISIONS ORIGINAL BUILDING DE >CRIPTION y, BUILDING JURISDICTION : SOUTH IIAMI Q PRIMARY USE CLASS : BUSINES CONSTRUCTION TYPE (NFPA) : TYPE I 332) w z „y• ?4ttr w.0it� x JJ l3:lila JI `'T x ~^I i NUMBER OF STORIES [SEVEN 3TORIESI. 1 CLASSIFICATION OF WORK : ALTERAT,ON - LEVEL 2 / \� ALLOWABLE AREA " NOT LII►4TED ( 3.+ NEW PROJECT DESCRIPTION A PROJECT AREA: : 10,949 SQ. FT. NON SPRINKLED. A APPLICABLE CODES PROTECT SITE *FLORIDA BUILDING CODE 2010 EDITION. • FLORIDA FIRE PREVENTION CODE 2010 EDITION. /� • NFPA 101 LIFE SAFETY CODE, 2009 EDITION. [A (CHAPTER 36 NEW BUSINESS). CL REQUIRED PARKING SPACES ARE AS FOLLOWS: 3 PARKING SPACES PER 1000 SQ. FT. ;�V 7.4h S( 101,658 GROSS BLDG. SQ. FT./333 SF PER SPACE = 305 SPACES REQUIRED a REQUIRED PROVIDED TOTAL PARKING SPACES (9' x 18') 305 SPACES 318 SPACES HANDICAP SPACES (12' x 18') 7 SPACES 19 SPACES APRIL 1, 2013 L rj JA a a r c h i t c it S FLORIDA LICENSE *AA0002689 2100 Ponce de Leon Blvd. Suite 1170, Coral Gables, Florida 33134 Tch (305)265 -7177 Fax: (305)262 -$435 LUIS E. NAYA• A1.A FL AR0008063 PROJECT NUMBER: 201301 INJEX OF DRAWINGS LIFE SAFETY MECHANICAL MO.00 SYMBOL LEGEND AND GENERAL NOTES - MECHANICAL LS -1 SIXTH FLOOR LIFE SAFETY PLAN. M3.00 SIXTH FLOOR PLAN, DEMOLITION - HVAC "A" M3.01 SIXTH FLOOR PLAN AREA - HVAC ARCHITECTURAL SIXTH FLOOR PLAN AREA "B" - HVAC M6.00 M6.00 SCHEDULES - HVAC M6.01 SCHEDULES - HVAC A -1 DEMOLITION PLAN, LEGEND AND N01 M7.00 DETAILS - HVAC A -2 SIXTH FLOOR PLAN, AREA "A ", LEGE AND NOTES. 117.01 DETAILS - HVAC A -3 PARTIAL 5TH FLR., 7TH FLR., ROOF M7,02 CONTROLS -HVAC AND SIXTH FLOOR PLAN, AREA "B ", GEND AND NOTES. A -4 SIXTH FLOOR EQUIPMENT PLAN, AR "A ". LEGEND AND NOTES. ELECTRICAL A -5 SIXTH FLOOR EQUIPMENT PLAN, ARE'B ", LEGEND AND NOTES. EO.00 SYMBOL LEGEND AND GENERAL NOTES - ELECTRICAL A -6 SIXTH FLOOR CEILING PLAN, AREA ", LEGEND AND NOTES, E0.01 LIGHTING FIXTURE SCHEDULE AND LIGHTING CONTROL DETAILS - ELECT. A -7 SIXTH FLOOR CEILING PLAN, AREA "1 LEGEND AND NOTES. E3.00 SIXTH FLOOR PLAN DEMOLITION - ELECTRICAL A -8 SECTIONS, LEGEND AND NOTES. E3.01 SIXTH FLOOR PLAN AREA "A" LIGHTING - ELECTRICAL A -9 INTERIOR ELEVATIONS E3.02 SIXTH FLOOR PLAN AREA "I" LIGHTING - ELECTRICAL A -10 INTERIOR ELEVATIONS E3.03 SIXTH FLOOR PLAN AREA "A" POWER - ELECTRICAL E3.04 SIXTH FLOOR PLAN AREA "U" POWER - ELECTRICAL A -11 INTERIOR ELEVATIONS E3.05 SIXTH FLOOR PLAN AREA "A" SYSTEMS - ELECTRICAL A -12 TYPICAL CARINET DETAILS E3.06 SIXTH FLOOR PLAN AREA "B" SYSTEMS -- ELECTRICAL A -13 TYPICAL RESTROOM PLANS, ELEVATIO AND DETAILS E5.00 POWER RISER DIAGRAM - ELECTRICAL A -14 ROOM FINISH SCHEDULE NOTES AND NAILS E5.01 FIRE ALARM RISER DIAGRAM - ELECTRICAL A -15 DOOR SCHEDULE. NOTES AND DETAIL E5.02 SYSTEMS RISER DIAGRAM - ELECTRICAL L -16 PARTITION TYPES, %TOTES AND DETAI E6.00 PANEL SCHEDULES - ELECTRICAL A -17 TYPICAL CEILING DETAILS - CONTINV. E6.01 PANEL SCHEDULES - ELECTRICAL A -la MISCELLANEOUS DETAILS. E7.00 SYSTEMS RISER DIAGRAM - ELECTRICAL A -19 PENETRATION AND FIRE RATING DETi.S. PLUM tI ING A -20 PENETRATION AND FIRE RATING DETLS. 7 PO.00 SYMBOL LEGEND AND GENERAL NOTES - PLUMBING ! P3.00 SIXTH FLOOR PLAN, DEMOLITION - PLUMBING P3.01 SIXTH FLOOR PLAN AREA "A" DRAINAGE - PLUMBING P3.02 SIXTH FLOOR PLAN AREA "B" DRAINAGE - PLUMBING P3.03 SIXTH FLOOR PLAN AREA "A" DOMESTIC WATER -- PLUMBING P3.04 SIXTH FLOOR PLAN AREA "B" DOMETIC WATER - PLUMBING P5.00 SIXTH FLOOR PLAN SANITARY ISOMETRIC -- PLUMBING P5.01 SIXTH FLOOR PLAN DOMESTIC WATER ISOMETRIC - PLUMBING P7.00 DETAILS - PLUMIRING P7.02 DETAILS - PLUMBING BUILDING I REVISIONS ORIGINAL BUILDING DE >CRIPTION BUILDING JURISDICTION : SOUTH IIAMI Q PRIMARY USE CLASS : BUSINES CONSTRUCTION TYPE (NFPA) : TYPE I 332) CONSTRUCTION TYPE : TYPE I-] FLORIDA BUILDING CODE NUMBER OF STORIES [SEVEN 3TORIESI. 1 CLASSIFICATION OF WORK : ALTERAT,ON - LEVEL 2 / \� ALLOWABLE AREA " NOT LII►4TED ( NEW PROJECT DESCRIPTION A PROJECT AREA: : 10,949 SQ. FT. NON SPRINKLED. A APPLICABLE CODES *FLORIDA BUILDING CODE 2010 EDITION. • FLORIDA FIRE PREVENTION CODE 2010 EDITION. /� • NFPA 101 LIFE SAFETY CODE, 2009 EDITION. [A (CHAPTER 36 NEW BUSINESS). PARKING INFORMATION REQUIRED PARKING SPACES ARE AS FOLLOWS: 3 PARKING SPACES PER 1000 SQ. FT. A (BASED ON SOUTH MIAMI LAND DEVELOPMENT CODE AT TIME OF ORIGINAL CONSTRUCTION) 101,658 GROSS BLDG. SQ. FT./333 SF PER SPACE = 305 SPACES REQUIRED a REQUIRED PROVIDED TOTAL PARKING SPACES (9' x 18') 305 SPACES 318 SPACES HANDICAP SPACES (12' x 18') 7 SPACES 19 SPACES _ -� - -, -+n n n wwAne Aw• w w w nn •n w w • A A• A A A • A A A A 'TIONS AB B R n n n nn n ewn n •n w .....� �.,.,. ..: wwWyl�yx:, +�- .w"°irr..Wtlf- wi•W'�rWW'° . ., A n nAA A Ann n ARCHITECTURAL Aaf1 VIATIONS: t>��ING DRAUJIN i AN nnnn" nnn"n nnnnn L ANGLE nnnA n" ^ n n • AT + n w n p G CENTERING nn� "n "n " n n n n O DIAMETER ID "INS C✓k PiarlE TK "l "I�it �I ") u UNPEF�GUT • POUND OR NUMleE:R IN INCHES UL UNDERWRITER'S LABO z.+TURIES 4 INT INTERIOR UNF UNFINISHED A/G AIR CONDITIONING J UON UNLE65 OTHERWISE NOTED ACI AMERICAN CONCRE=TE INSTITUTE JAN JA ^41TOR U05 UNLESS OTr,ER 5f='ECIFIED ACP ASBESTOS CEMENT PeE JE3 JUNCTION BOX UR URINAL ACSC ASPHALTIC CONCRETE 5JRFAGE GOUrc6E JGT JUNCTION UTIL UTILITY ACU AIR CONDITIONING UNIT J5< JANITORS SINK V ACT ACOUSTICAL CEILING TILE JT JOINT AD AREA GRAIN !� vl:.5 VINYL ADJ ADJU5TAE3LrE K VCT VINYL CO 'F'051TIUh TIDE A/E ARCHITECT /ENCzINE.I*t2 KNACK OUT vEERT VERTICAL AF ACCESS FLOORING KO VEST VE5TIBULE AFF ABOVE FINISHED FLOOR L VF VERIFY IN FIELD AG6 p, AGGREGATE VOL vOLuME AHU AIR HANDLING UNIT L LEr,GTH VT VAPOR TIGHT ALT ALTERNATE LAM LAMINATE VTF< VENT THRU ROOF AL ALUMINUM LAV LAVATORY ANN ANNUNCIATOFZ L55 POJND5 W , AN61 AMERICAN NATIONAL STANDARDS iNSTITUTE L55 /HR POUNDS PER HOUR ANT ANTENNA LD LINEAR DIFFUSER WR WIRE AP ACCESS PANEL LP LOW POINT W WINDOW APL AC-CF-55 PLENUM LT LIGHT W/ WITH APROX APPROXIMATE WC WATER CLOSET ARCH WD ARCHITECTURAL m WD WOOD WALL GLEANOUT A55 ASBESTOS MATL i IATER14L ASPH ASPi"IALT MAX MAXIMUM WF WALL FABRIC ASTM AMERICAN SOCIETY OF TEbTING t MATErzIAL5 MG MEDICINE C«•AL::NET We WITHOUT 15 MECH MECHANICAL WS WATER PROOF MEMB MEMBRANE WT WAINSCOT BAT i3ATTERY Wt WEICsI -iT BD BOARD MFR MANUFACTURER WWF WELDED WIRE FABRIC BITUM 5ITUMINOL46 MIN MINIMUM WW 1 WELDED WIRE MESH BLDG BUILDING MISG MISCELANEOU5 BLKG E3LOCKIN6% MO MASONRY OPENING BM 15EAM MTD' MOUNTED BOT BOTTOM MTL METAL MUL r ^ULL ION Cr MULT MULTIPLE CA5 CABINET CB CATCH 5A61N GEM CEMENT N NORTH GER CERAMIC NEC NATIONAL ELECTt�IG DOGE CFM CUBIC FEET PER MINUTE NIC NOT IN CONTRACT GCs CORNER GUARD NO NUM5ER CHP CRICKET HIGH POINT ROM NOMINAL GI CAST IRON NPL NAME PLATE CIG CAST IRON COVER NT5 NOT TO SCALE; CIF CAST IRON PIPE GJ CONTROL JOINT 0 CLG CEILING OA OVERALL CLGD CEILING DIFFUSER OBS 085CURE CLKG CAULKING OG ON CENTER CLO CLOSET OD OUTSIDE DIAMETER DIM) CLP CRICKET LOW POINT OF5 OVEFFLOW 5r-UPPER CLR CLOSER OPP OPPOSITE CMP CORRUGATED METAL PIPE CMU CONCRETE MA50NRY UNIT iz CNTR COUNTER PC FRECA5T CONCRETE CO CLEAN OJT PJ PIPE JOINT COL COLUMN PL PLASTIC Comm COMMUNICATION P LAM PLASTIC LAMINATE CONG CONCRETE PLA5 PLASTER CONN CONNECTION PLYWD PLYWOOD GON5T5 CONSTRUCTION PNT PAINT CONT CONTINUOUS PT POINT OR PATIENT PTD PAPER TOWEL D15PENCER CPT CARPET TILE PTN PAPER TN CT CERAMIC TILE CTR CENTER PAPER TOWEL RECEPTACLE CT5K COUNTERSUNK Q 0 CRT QUARTER pBL DOUBLE QT QUARRY TILk DEG DEGREE DEPT DEPARTMENT R REAR DE51G DESIGNATION RA RETURN AIR DET DETAIL RAP RADIUS DF DRINKING FOUNTAIN Rg REINFORCED L3EAM pG DOOR. GRILLE RCPT RECEPTION DIA DIAMETER RD ROOF DRAIN DIAL DIAGRAM REF REFERENCE DIM DIMENSION REINF REINFORCED D15R P15PEN5ER REQ REQUIRED DIN DOWN RE5L FRE51LIENT PO DOOR OPENING RGTR REGISTER D5P DRY STANDPIPE RM ROOM D5 DOWN SPOUT RO ROUGH OPENING pWG5 DRAWING5 RWL RAIN WATER LEADEhK DWR DRAWER a E 5 STUCCO EA EACH SG SCREED CONCRE=TE EC EPDXY COATING SCHED SCHEDULE EHD ELEGTKIG HAND DRYER SEC SECOND EL ELEVATION 5D SMOKE DETECTOR EJ EXPANSION JOINT SECT SECTION ELEG ELECTRICAL 5F SUPPLY FAN ELEV ELEVATOR 5G SPANDREL GLASS EMER EMERGENCY SGR SYNTHETIC GRADE ENCL ENCLOSURE SHR SHOWER ENGR ENGINEER SHT SHEET EPNL ELECTRICAL PANEL 51G SIGNAL EQ EQUAL SIM SIMILAR EQPT EQUIPMENT 5,K SINK EST ESTIMATE 5M SHEET META; ET EXPANSION TANK SMK SMOKE EWG ELECTRIC WATER COOLER 5ND SOUND EXH EXHAUST SPEC SPECIFICATION EX5T EXISTING SPKR 5PEAKER5 fA` T EXTERIOR 5Q 50UARE FIRE ALARM 55T SQUARE FEET FABL FIRE ALARI"1 BELL 5ST STAINLESS STEEL FD FLOOR DRAIN 5T STREET t•�GLASS 5tG SOUND TRANSMISSION COEFFICIENT FG FIBE STD STANDARD FGO FLOOR CLEANOUT FD FIRE DAMPER ST-D STORM DRAIN FDG FIRE DEPARTMENT CONNECTOR 5TL STEEL 5TRL STRUCTURAL FpR FIRE DOOR 5 FDN FOUNDATIONS M SYMMETRICAL SUSPENDED FDV FIRE DEPARTMENT VALVE SYS FEC FIRE EXTINGUISHER CABINET 5Y5 SYSTEM FEX FIRE EXTINGUISHER T FF FINISH FLOOR T TOILET FH FIRE HYDRANT TB TIE BEAM FIN FINISH TC TIE COLUMN FL FLOOR TEL TELEPHONE FM FACTORY MANUAL TEMP TEMPERATURE FLASH FLASHING TtG TONGUE AND GROVE FLG FLANGE TH< THICK FLOUR FLUORESCENT TOG TOP OF GURY FOC FACE OF CONCRETE TOPP TOP OF PARAPET FOF FACE OF FIN16H TO$ TOP OF SLAB FOM FACE OF MASONRY TP TOP OF PAVEMENT F05 FACE OF STUD TRD TREAD FPRF FIREPROOF T5 %13ULAF2 STEEL FPM FEET PER MINUTE T THERMOSTAT FRD FRENCH DRAIN TV V TELEVISION FE TW TOP OF WALL 5 FULL 51Z TYP TYPICAL FT FOOT OR FEET FTG FOOTING FT -LB FOOT POUND5 FURR FURRING FLIT FUTURE co GAUGE GAL GALLON GALV GALVANIZED GB GRADE BEAM GEN GENERATOR GL GLA55 GND GROUND GLB GLASS BLOCK GR GRILLE GRP GRADE .••�'y GW5 GYPSUM WALL BOARD * J 7 GYP GYPSUM • �'' � '' • J1 HB HOSE BIB HG WANDIGAPF EP +�` '+ '• HDWD HARDWOOD �% 0 HDWE HARDWARErJj w HGT HEIGHT HM HOLLOW METAL HORIZ HORIZONTAL HP HIGH POINT HR HOUR +, HEATER �•'�„r . • •' g�. HTR E HVAC HEATING, VENTILATION, AND AIR CONDITIONING * w ,- HYD HYDRANT