09-629-036N
O
O
N
O
N
4TH FLOOR PLAN - LIGHTING
1/811 = 11 -011
KEY NOTES:
OCONTRACTOR SHALL DISCONNECT AND REMOVE EXISTING LIGHT
FIXTURE AND REINSTALL EXISTING LIGHT FIXTURE PER CEILING
GRID REWORK. CONTRACTOR SHALL EXTEND EXISTING
CIRCUITRY TO ACCOMMODATE EXISTING RELOCATED FIXTURE.
CONTRACTOR SHALL PROVIDE ALL HARDWARE, WIRE, CONDUIT,
ETC REQUIRED TO EXTEND THE EXISTING CIRCUITRY,
3 O REMOVE EXISTING WALL SCONCE AND REPLACE WITH NEW "D"
FIXTURE.
ODISCONNECT AND REMOVE EXISTING WALL WASHER LIGHT
FIXTURE. CONTRACTOR SHALL MAINTAIN CONTINUITY OF
EXISTING CIRCUITRY.
GENERAL NOTES:
1. CONTRACTOR SHALL DISCONNECT AND REMOVE EXISTING
EXIT LIGHTS AND REINSTALL EXIT LIGHTS IN SAME
LOCATION PER GRID REWORK.
2. THE GC IS TO VERIFY THAT ALL MAIN CORRIDOR AND
LOBBY EXIT SIGNS ARE INSTALLED AND ARE IN PROPER
WORKING CONDITION; EXIT SIGN LOCATION AS SHOWN
ON THE DRAWINGS. IF AND EXIT SIGN IS NOT IN
WORKING CONDITION OR IS MISSING, INSTALL A NEW
EXIT SIGN PER STATE AND LOCAL CODE.
3. ALL EMERGENCY LIGHTS AND BATTERY UNIT SHALL
REMAIN UNSWITCHED.
5TH FLOOR PLAN - LIGHTING
1/811 = 11 -011
7TH FLOOR PLAN - LIGHTING
1/8" = 11 -0f1
PxsTiNG rG 1 '. C 1 '1 °aW1v1S <31
)wjTrl Tits P� � &s SET 8E7 FUfiY1, !N "i X11 ;. ,ili� I ; ;:ly'i��d'110i: CoD
� askew
nlxon
ferguson
architects
Architecture
1500 Union
Planning
Avenue
Interior
Memphis, TN
Design
38104
Tel.
901- 278 -6868
www.anfa.com
1 1119109 GENERAL REVISION
jREV.NO.j DATE I DESCRIPTION
PROJECT STATUS
CONSTRUCTION DOCUMENT
PROJECT NAME
ONE 7000 F 'ACE
SW 62 AVE.
MIAMI, FL 33143
SHEET TITLE
FOURTH, FIFTH &
SEVENTH FLOOR
LIGHTING
PLANS
DRAWN CHECKED
�A
x v
vvui
GDW DEC 08048
DATE SHEET NO.
07 -08 -2009 E101
Q 2009 ASKEW NIXON FERGUSON ARCHITECTS INC.