09-629-031
ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION FINISH LIGHTING REMARKS I COMMUNICATIONS 2'x2' LAY —IN FLUORESCENT LIGHTING FIXTURE ► TELEPHONE OUTLET �A (LETTER REFERENCES FIXTURE SCHEDULE) Q TELEPHONE OUTLET IN FLOOR #2SP8— G -3 -17— FLUORESCENT LIGHTING FIXTURE — DUAL SWITCHED ® COMBINATION TELEPHONE /DATA OUTLET COORDINATE LIGHT FIXTURE WITH FLUORESCENT EMERGENCY LIGHTING FIXTURE COMBINATION TELEPHONE /DATA OUTLET IN FLOOR 3509K INCANDESCENT, FLUORESCENT OR H.I.D. LIGHTING FIXTURE S Q CEILING MOUNTED SPEAKER q (LETTER REFERENCES FIXTURE SCHEDULE) GOTHAM RESCESSED iOO WALL MOUNTED SPEAKER K> WALL MOUNTED LIGHTING FIXTURE 18o VERIFY —� TV ANTENNA OUTLET IN WALL .<- POLE MOUNTED LIGHTING FIXTURE IC INTERCOM STATION 0 MASTER INTERCOM STATION (1) EXIT SIGN (FURNISH WITH DUAL FACES AND DIRECTIONAL ARROWS SURFACE C WHERE INDICATED) #S— 1 —32—MVOLT SECURITY VERIFY EMERGENCY LIGHTING UNIT —GEB 101S 3509K CCTV CAMERA CR CARD READER ALUCHE LIGHTING SERVICE AND DISTRIBUTION WALL MOUNTED D CS CALL STATION ® SWITCHBOARD KK KEYPAD ® DISTRIBUTION PANEL RX REQUEST —TO —EXIT PUSHBUTTON ® BRANCH CIRCUIT PANEL QS ELECTRIC STRIKE QT TRANSFORMER OM MAGNETIC LOCK �S MOTOR CONNECTION OB TOUCH —SENSE BAR D, DISCONNECT SWITCH (FUSED AS REQUIRED) CHROME FIRE ALARM MOTOR CONTROLLER E27 (SPECIFIED IN OTHER THAN DIV. 16) �F FIRE ALARM MANUAL PULL STATION EQUIPMENT NOT FURNISHED UNDER DIV. 16 H FIRE ALARM HEAT DETECTOR FRAME (SPECIFIED IN OTHER THAN DIV. 16) US FIRE ALARM SMOKE DETECTOR ® EQUIPMENT ELECTRICAL CONNECTION QS FIRE ALARM SMOKE DETECTOR (HVAC DUCT MOUNTED) ®M ELECTRIC METER 0 FIRE ALARM WATERFLOW SWITCH LC LIGHTING CONTACTOR Ell FIRE ALARM HORN FPKI PHOTOCELL [o". FIRE ALARM STROBE FT C] TIME CLOCK FIRE ALARM COMBINATION HORN & STROBE © SPRINKLER SYSTEM PRESSURE SWITCH BASIC MATERIALS U SPRINKLER SYSTEM SOLENOID VALVE Q FIRE ALARM TAMPER SWITCH 1 BRANCH CIRCUIT WIRE & CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING, HOME RUN TO PANELBOARD. A NUMERAL, IF PRESENT AT ARROW OPIV SPRINKLER SYSTEM POST INDICATOR VALVE TAMPER SWITCH HEAD, INDICATES CIRCUIT NUMBER. ANY BRANCH CIRCUIT SHOWN WITHOUT SLASH MARKS INDICATES A CONDUIT CONTAINING (3) #12 AWG CONDUCTORS O MAGNETIC DOOR HOLDER (HOT, NEUTRAL & GROUND). SLASH MARKS, IF PRESENT, INDICATE THE FAC FIRE ALARM CONTROL PANEL FOLLOWING: FAA FIRE ALARM ANNUNCIATOR HOT (ENERGIZED) CONDUCTOR NEUTRAL CONDUCTOR I ABBREVIATIONS GROUND CONDUCTOR AF AMPERES FRAME AFF ABOVE FINISHED FLOOR WIRE & CONDUIT RUN EXPOSED AFG ABOVE FINISHED GRADE AIC AMPERES INTERRUPTING CAPACITY WIRE & CONDUIT RUN IN /UNDER FLOOR OR BELOW GRADE AT AMPERES TRIP WIRE & CONDUIT TURNED UP ATS AUTOMATIC TRANSFER SWITCH C CONDUIT WIRE & CONDUIT TURNED DOWN CB CIRCUIT BREAKER --�— /— BARE GROUND CONDUCTOR CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED GKT CIRCUIT Q GROUND ROD (3/4" x 10') CT CURRENT TRANSFORMER JO JUNCTION BOX DISC DISCONNECT Q PUSHBUTTON EDF ELECTRIC DRINKING FOUNTAIN FACP FIRE ALARM CONTROL PANEL $r, MANUAL MOTOR STARTER SWITCH FLA FULL LOAD AMPS $ SINGLE —POLE, SINGLE —THROW (S.P.S.T.) WALL SWITCH FR FRAME FVNR FULL VOLTAGE NON— REVERSING $K KEYED S.P.S.T WALL SWITCH G GROUND $D WALL BOX DIMMER GA GROUND FAULT CIRCUIT — INTERRUPTER $s DOUBLE —POLE, SINGLE —THROW (D.P.S.T.) WALL SWITCH HOA HAND —OFF —AUTO MCP MOTOR CIRCUIT PROTECTOR $3 SINGLE —POLE, DOUBLE —THROW (S.P.D.T.) WALL SWITCH MLO MAIN LUGS ONLY $4 DOUBLE —POLE, DOUBLE —THROW (D.P.D.T.) WALL SWITCH NF NON —FUSED e-- SINGLE RECEPTACLE IN WALL (NEMA 5 -20R) OHE OVERHEAD ELECTRIC PIV POST INDICATOR VALVE � DUPLEX RECEPTACLE IN WALL (NEMA 5 -20R) RAP REMOTE ANNUNCIATOR PANEL G.F.I. TYPE DUPLEX RECEPTACLE IN WALL (NEMA 5 -20R) RGS RIGID GALVANIZED STEEL DUPLEX RECEPTACLE IN WALL, SPLIT WIRED (NEMA 5 -20R) SOWB SPACE ONLY WITH BUS UNO UNLESS NOTED OTHERWISE ISOLATED— GROUND DUPLEX RECEPTACLE IN WALL (NEMA 5- 20R —IG) WP WEATHERPROOF ISOLATED— GROUND DOUBLE DUPLEX RECEPTACLE IN WALL (NEMA 5- 20R —I0) XFMR TRANSFORMER ® DUPLEX RECEPTACLE IN FLOOR (NEMA 5 -20R) 3P THREE POLE 3PH THREE PHASE DOUBLE DUPLEX RECEPTACLE IN WALL (NEMA 5 -20R) 4W FOUR WIRE ®- SPECIAL RECEPTACLE AS INDICATED 30/3 30 AMPERE, 3 —POLE NOTE 1: ALL SYMBOLS MAY NOT BE USED ON THIS PROJECT. NOTE 2: SYMBOLS FOR SECURITY AND COMMUNICATIONS EQUIPMENT REPRESENT ELECTRICAL ROUGH —INS ONLY. INSTALL (1) -3/4 "C FROM EACH ROUGH —IN TO NEAREST ACCESSIBLE CEILING SPACE UNLESS NOTED OTHERWISE. N_ Yl u7 a� 0 O N 0 N IT LIGHTING FIXTURE SCHEDULE MARK DESCRIPTION MANUFACTURER LAMP FINISH MOUNTING REMARKS 2'x2' LAY —IN LITHONIA 901- 278 -6868 LAY —IN DIFFUSER SHALL MATCH EXISTING. A LENSED TROFFER #2SP8— G -3 -17— F17WT8 MATCH COORDINATE LIGHT FIXTURE WITH MVOLT- 1 /3— GEB101S 3509K EXISTING EXISTING 8" COMPACT GOTHAM RESCESSED B FLUORESCENT #AF— 1 — 1 8DTT-8— 18o VERIFY DOWN LIGHT AR— MVO LT 3509K 4' FLUORESCENT LITHONIA (1) SURFACE C STRIP FIXTURE #S— 1 —32—MVOLT VERIFY —GEB 101S 3509K WALL SCONCE ALUCHE LIGHTING WALL MOUNTED D #31127 18W BRUSHED 3500' K NICKEL PENDANT MOUNTED OSSY #OSSY50 (1) BLACK PENDANT MOUNTED F FIXTURE FIXTURE 21) CHROME E27 BASE AND FRAME �A7(I } Architecture 1500 Union Planning Avenue Interior Memphis, TN Design 38104 Tel. 901- 278 -6868 www.anM.com REV. NO. I IDATF—F DESCRIPTION PROJECT STATUS CONSTRUCTION DOCUMENT PROJECT NAME ONE 7000 PLACE SW 62 AVE. MIAMI, FL 33143 SHEET TITLE SEAL ELECTRICAL LEGEND ' AND SCHEDULE`+ r. .Q S a° Lv it g v i Y} I DRAWN CHECKED PROJECT NUMBER GDW DEC 08048 DATE SHEET NO. E001 w,; 07 -08 -2009 E 0 01 k' Q 2009 ASKEW NIXON FERGUSON ARCHITECTS INC. i.