09-629-030
ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION FINISH LIGHTING REMARKS I COMMUNICATIONS 2'x2' LAY —IN FLUORESCENT LIGHTING FIXTURE ► TELEPHONE OUTLET �A (LETTER REFERENCES FIXTURE SCHEDULE) Q TELEPHONE OUTLET IN FLOOR #2SP8— G -3 -17— FLUORESCENT LIGHTING FIXTURE — DUAL SWITCHED P COMBINATION TELEPHONE /DATA OUTLET COORDINATE LIGHT FIXTURE WITH FLUORESCENT EMERGENCY LIGHTING FIXTURE 08048 ` COMBINATION TELEPHONE /DATA OUTLET IN FLOOR 3509K 3500' K INCANDESCENT, FLUORESCENT OR H.I.D. LIGHTING FIXTURE 0 CEILING MOUNTED SPEAKER A (LETTER REFERENCES FIXTURE SCHEDULE) GOTHAM RESCESSED Ids WALL MOUNTED SPEAKER K> WALL MOUNTED LIGHTING FIXTURE 18DTT VERIFY —4> TV ANTENNA OUTLET IN WALL - POLE MOUNTED LIGHTING FIXTURE IC INTERCOM STATION 0 MASTER INTERCOM STATION (1) EXIT SIGN (FURNISH WITH DUAL FACES AND DIRECTIONAL ARROWS SURFACE C WHERE INDICATED) #S— 1 —32— MVOLT SECURITY VERIFY EMERGENCY LIGHTING UNIT CCTV CAMERA — GEB101S CR CARD READER SERVICE AND DISTRIBUTION CALL STATION ALUCHE LIGHTING (1) CS WALL MOUNTED ® SWITCHBOARD QK KEYPAD ® DISTRIBUTION PANEL RX REQUEST —TO —EXIT PUSHBUTTON ® BRANCH CIRCUIT PANEL QS ELECTRIC STRIKE FT TRANSFORMER OM MAGNETIC LOCK 0 MOTOR CONNECTION I TOUCH —SENSE BAR E�h DISCONNECT SWITCH (FUSED AS REQUIRED) F FIRE ALARM MOTOR CONTROLLER CHROME (SPECIFIED IN OTHER THAN DIV. 16) 0 FIRE ALARM MANUAL PULL STATION r , EQUIPMENT NOT FURNISHED UNDER DIV. 16 QH FIRE ALARM HEAT DETECTOR (SPECIFIED IN OTHER THAN DN. 16) LITHONIA LED SEE DRAWINGS US FIRE ALARM SMOKE DETECTOR ® EQUIPMENT ELECTRICAL CONNECTION S® FIRE ALARM SMOKE DETECTOR (HVAC DUCT MOUNTED) �M ELECTRIC METER UW FIRE ALARM WATERFLOW SWITCH LC LIGHTING CONTACTOR FIRE ALARM HORN PC PHOTOCELL ��" FIRE ALARM STROBE ITC] TIME CLOCK Ell FIRE ALARM COMBINATION HORN & STROBE Eg © SPRINKLER SYSTEM PRESSURE SWITCH BASIC MATERIALS O SPRINKLER SYSTEM SOLENOID VALVE 0 FIRE ALARM TAMPER SWITCH 1 BRANCH CIRCUIT WIRE & CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING, HOME RUN TO PANELBOARD. A NUMERAL, IF PRESENT AT ARROW OPIV SPRINKLER SYSTEM POST INDICATOR VALVE TAMPER SWITCH HEAD, INDICATES CIRCUIT NUMBER. ANY BRANCH CIRCUIT SHOWN WITHOUT SLASH MARKS INDICATES A CONDUIT CONTAINING (3) #12 AWG CONDUCTORS MAGNETIC DOOR HOLDER (HOT, NEUTRAL & GROUND). SLASH MARKS, IF PRESENT, INDICATE THE AC FIRE ALARM CONTROL PANEL FOLLOWING: FF-A-Al FIRE ALARM ANNUNCIATOR HOT (ENERGIZED) CONDUCTOR NEUTRAL CONDUCTOR I ABBREVIATIONS GROUND CONDUCTOR AF AMPERES FRAME AFF ABOVE FINISHED FLOOR WIRE & CONDUIT RUN EXPOSED AFG ABOVE FINISHED GRADE AIC AMPERES INTERRUPTING CAPACITY WIRE & CONDUIT RUN IN /UNDER FLOOR OR BELOW GRADE AT AMPERES TRIP WIRE & CONDUIT TURNED UP ATS AUTOMATIC TRANSFER SWITCH C CONDUIT �y WIRE & CONDUIT TURNED DOWN CB CIRCUIT BREAKER --� —�— BARE GROUND CONDUCTOR CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED CKT CIRCUIT Q GROUND ROD (3/4" x 10') CT CURRENT TRANSFORMER Q JUNCTION BOX DISC DISCONNECT PUSHBUTTON EDF ELECTRIC DRINKING FOUNTAIN FACP FIRE ALARM CONTROL PANEL $M MANUAL MOTOR STARTER SWITCH FLA FULL LOAD AMPS $ SINGLE —POLE, SINGLE —THROW (S.P.S.T.) WALL SWITCH FR FRAME FVNR FULL VOLTAGE NON— REVERSING $K KEYED S.P.S.T WALL SWITCH G GROUND $o WALL BOX DIMMER GFI GROUND FAULT CIRCUIT — INTERRUPTER $2 DOUBLE —POLE, SINGLE —THROW (D.P.S.T.) WALL SWITCH HOA HAND —OFF —AUTO MCP MOTOR CIRCUIT PROTECTOR $3 SINGLE —POLE, DOUBLE —THROW (S.P.D.T.) WALL SWITCH MLO MAIN LUGS ONLY $4 DOUBLE —POLE, DOUBLE —THROW (D.P.D.T.) WALL SWITCH NF NON —FUSED e- SINGLE RECEPTACLE IN WALL (NEMA 5 -20R) OHE OVERHEAD ELECTRIC PIV POST INDICATOR VALVE � DUPLEX RECEPTACLE IN WALL (NEMA 5 -20R) RAP REMOTE ANNUNCIATOR PANEL G.F.I. TYPE DUPLEX RECEPTACLE IN WALL (NEMA 5 -20R) RGS RIGID GALVANIZED STEEL A� DUPLEX RECEPTACLE IN WALL, SPLIT WIRED (NEMA 5 -20R) SOWB SPACE ONLY WITH BUS UNO UNLESS NOTED OTHERWISE ISOLATED— GROUND DUPLEX RECEPTACLE IN WALL (NEMA 5- 20R —I0) WP WEATHERPROOF ISOLATED— GROUND DOUBLE DUPLEX RECEPTACLE IN WALL (NEMA 5- 20R —IG) XFMR TRANSFORMER ® DUPLEX RECEPTACLE IN FLOOR (NEMA 5 -20R) 3P THREE POLE 3PH THREE PHASE 0 DOUBLE DUPLEX RECEPTACLE IN WALL (NEMA 5 -20R) 4W FOUR WIRE 0- SPECIAL RECEPTACLE AS INDICATED 30/3 30 AMPERE, 3 —POLE NOTE 1: ALL SYMBOLS MAY NOT BE USED ON THIS PROJECT. NOTE 2: SYMBOLS FOR SECURITY AND COMMUNICATIONS EQUIPMENT REPRESENT ELECTRICAL ROUGH —INS ONLY. INSTALL (1) -3/4 "C FROM EACH ROUGH —IN TO NEAREST ACCESSIBLE CEILING SPACE UNLESS NOTED OTHERWISE. N_ III L f` u7 b' C) N O N wr LIGHTING FIXTURE SCHEDULE MARK DESCRIPTION MANUFACTURER LAMP FINISH MOUNTING REMARKS 2'x2' LAY —IN LITHONIA (3) LAY —IN DIFFUSER SHALL MATCH EXISTING. LENSED TROFFER #2SP8— G -3 -17— MATCH DRAWN CHECKED COORDINATE LIGHT FIXTURE WITH A 08048 ` 3- 1/3 MVOLT -1 / 3509K 3500' K EXISTING EXISTING 8" COMPACT GOTHAM RESCESSED B FLUORESCENT #AF— 1 — 18DTT-8— 18DTT VERIFY DOWNLIGH'T AR —MVOLT 3500'K 4' FLUORESCENT LITHONIA (1) SURFACE C STRIP FIXTURE #S— 1 —32— MVOLT VERIFY — GEB101S 3509K WALL SCOINCE ALUCHE LIGHTING (1) WALL MOUNTED D #31127 18W BRUSHED 3500' K NICKEL PENDANT (MOUNTED OSSY #OSSY50 (1) BLACK PENDANT MOUNTED F FIXTURE FIXTURE 21) CHROME E27 BASE AND EXIT SIGN LITHONIA LED SEE DRAWINGS #LAMS— I —G -120 WHITE —EL —N BATTERY UNIT LITHONIA (2) 2) WHITE SEE DRAWINGS Eg #ELM2 —H- 120/277 HALO askew nixon fer o uson architects Architecture 1500 Union Planning Avenue Interior Memphis, TN Design 38104 Tel. 901 - 278 -6868 www.anfa.com 1 1119109 GENERAL REVISION REV.NO.j DATE I DESCRIPTION PROJECT STATUS CONSTRUCTION DOCUMENT PROJECT NAME ONE 7000 PLACE SW 62 AVE' MIAMI, FL 1, s SHEET TITLE "r p Y k1� ELECTRICAL LEGEND :, _ , •' : ' �!•d, AND SCHEDULE',:; rr�Q 1` e DRAWN CHECKED PROJECT NUMBER GDW DEC 08048 ` DATE SHEET NO. E 0 0 07 -08 -2009 (Q 2009 ASKEW NIXON FERGUSON ARCHITECTS INC.