09-629-0205 N O CV rn 0 O N 00 izz O O O O 1/8" A B LIGHT BOX ASSEMBLY -1 1/4" = 1' -0" 0 0 1. ASSEMBLE ARMSTRONG DRYWALL METAL FRAME (APPROXIMATELEY 2' X 4' BETWEEN 2" BEAMS) 2. FIT PLYWOOD PANELS TO (FRAME (ALLOW 3 314" OVERHANG ALL AROUND. LAYOUT ......................... ............................... ........ ............ ...... ;.................. ;........ BASED ON 2'x 7' -4" SHEETS AROUND PERIMETER.) ,� \0 '• NOTE: GAPS BETWEEN SH EETS WILL NOT BE AN ISSUE. 0 3. ATTACH 5/8" PLYWOOD TO EDGE OF PLYWOOD ........ 4 PANELS - ATTACHING WITH ALUMINUM ANGLE BRACKET I" 4. ATTACH 10 - 4' FLOURESCENT FIXTURES TO PLYWOOD \ PANELS @ 19" ON CENTER. - I 5. FIT DELUXE FRAME EDGING TO 5/8" PLYWOOD -FIT MITRED CORNER EDGING TO ALL 4 CORNERS i USING LIQUID NAILS AND SMALL PAN HEAD SCREWS. ; ONCE FITTED, CUT THE SHORT LENTHS TO SIZE AND FIT i IN THE GAP. j 6. ADD WOVIN WALL GRID TOI FRAME - ASSEMBLE GRID IN TWO HALVES.,_ " -FIX GRID TO FRAME WITH SCREWS, PUSHING IT OUTWARDS SO AS TO BE EVEN AND TIGHT AGAINST THE EDGE. - ° --- - 7. SPACERS SUPPLIED BY WOVIN WALL 1" x 1" WIDE, 4" O DEEP TO SUPPORT FRAME AT EACH SECOND CROSS OF GRID. _.._ — r _ O Q� 8. TILES THEN SLOT INTO GRIID AND HIDE ALL OF THE STRUCTURE BEHIND. LIGHT BOX ASSEMBLY -2 1/41' = 1' -0" CG2 0 0 0 (D) OE 0 s •� a a "3 0 .3 - �+ J Su a•a FACE OFLIGHTBOXTOBE WRAPPED WIJij ••� ¢Wa ••• SPECTRIM (TR3) • a see a . . . • �.. ,' •. 5/8" PLYWOOD •sss ssa. tee ARMSTRONG DRYWALL SYSTEM •_ . 0 4 a s k e w 1 I I MANUFACTURER RECOMMENDATION ••a� � '� r (.('r h I t e c t 4314"1 ALUMINUM ANGLE BRACKET 1" SPACER SUPPLIED BY 3 -FORM Architecture 1500 Union Avenue Planning Memphis, TN 38104 Interior Design Tel. 901- 278 -6868 1 www.onfo.com 4' FLUORESCENT LIGHT STRIP GENERAL NOTES WOVIN WALL GRID 1. REUSE ALL EXISTING CORRIDOR LIGHT FIXTURES, REPLACE ANY BROKEN DIFFUSERS. WOVIN PANEL 2. KEEP ALL CORRIDOR EXIT LIGHTS IN PLACE. DELUXE 3 -FORM EDGING FIXED TO PLYWOOD FACADE 3. REPLACE ALL CEILING GRID THAT IS RUSTED OR STAINED LIGHT BOX SECTION DETAIL WITH MATCHING GRID. 4. REPLACE ALL CEILING TILES. 3" = 1' -0" 5. CLEAN ALL EXISTING DIFFUSERS & LIGHTS. CEILING LEGEND OF 2'x2' FLUORESCENT LIGHT FIXTURE 2ND FLOOR •► 1/8'. = 1' -0" E EFLECTED CEILING PLAN ^o 0 O u 0 0 ESTROOM 0 REMAIN, TYP. I" .— 2'x4' FLUORESCENT LIGHT FIXTURE WALL SCONCE FIXTURE M � , IREV.NO.l DATE I DESCRIPTION PROJECT STATUS 3 CONSTRUCTION DOCUMENT PROJECT NAME ft.,, 3RD FLOOR r 1/8" = 1 '-0" EFLECTED CEILING PLAN ONE 7000 PLACE 7000 SW 62 AVE. MIAMI, FL 33143 SHEET TITLE FIRST, SECOND & THIRD REFLEC EL CEILING PLANS i yX SEAL 5 X of © 2009 ASKEW NIXON FERGUSON ARCHITECTS INC. ::,, DRAWN CHECKED PROJECT NUMBER JLD JPW 08048 DATE SHEET NO. 07 -08 -2009 A211� © 2009 ASKEW NIXON FERGUSON ARCHITECTS INC.