Loading...
09-629-002:r E DIALYSIS' - 2`007 FLON-ftlu"A BUILr%lNjft 0"DE K 1 M 'U"NSPRINKLERED"' JURISDICTION Miami & Dade County Construction Cade Enforcement LIFE SAFETY + CODE REVIEW REV. NO. State of Florida Division of Fire Prevention DESCRIPTION 2007 Florida Plumbing Code, Dade County Edition 2007 Florida Fuel Gas Code, Dade County Edition 2007 Florida Mechanical Code, Dade County Edition 2007 Florida Electrical Code, Dade County Edition 2007 Florida Fire Prevention Code, Dade County Edition 2007 Florida Building Code - Accessibility OCCUPANCY Business Group B Section 304 CLASSIFICATION OCCUPANTLOAD Business Area 100 gross 988 Occupants Table 1004.1.1 EXITS Maximum Dead End 200-01" Section 1017.3 Corridor Minimum Clear Door 32" Table 1008.1.1 Width MINIMUM CORRIDOR 148(Occupants /floor) x .15 = 29.41" / 2 (Exits) = 14.71" Section 1005.1 / 1017.2 WIDTH (56" provided) / (44" minimum width required) INTERIOR FINISHES Class A - Vertical Exits and Exit Passageways, Class B - Corridors Table 803.5 TOILET ACCESSABILITY 1 Accessible Unisex Toilet Room per Floor (1 provided) 11 -4.5.1 (2)(e) REQUIRED RATINGS Corridors 1 Hour Table 1017.1 Doors accessing 1 hour 20 min Table 715.4 corridor Vertical exit closures 2 Hour Section 1020.1 (buildings over 4 stories tall) Door in vertical exit 90 min Table 1017.1 closure - 2 hour rated wall Tenant Seperation No Separation Required Section 708.1 (Exception 1) HANDICAP ELEMENTS Hardware Lever handles throughout with knurled surfaces to hazard areas Signage As Required Fire Alarm Required Section 907.2.2 Emergency Lighting Required Section 1006 Fire Extinguishers Required NFPA 10 Height Above Finished Floor - Top of Extinguisher 60" AFF Max Section 6.1.3.8 9 ral LO N 66 LO a Fill! 1A .ii' 0 �` :b ii i s I 40 4 �� askew, III \v wea Architecture 1500 Union Avenue Planning Memphis, TN 3€3101 Interior Design Tel. 901 - 278 -6868 www.clnfa.COff1 G000 COVER SHEET G101 GENERAL SPECIFICATIONS G201 LIFE SAFETY PLANS G202 LIFE SAFETY PLANS A101 FIRST, SECOND & THIRD FLOOR DEMOLITION PLANS A102 FOURTH, FIFTH & SEVENTH FLOOR DEMOLITION PLANS A201 FIRST, SECOND & THIRD FLOOR FINISH FLOOR PLANS A202 FOURTH, FIFTH & SEVENTH FLOOR FINISH FLOOR PLANS A211 FIRST, SECOND & "THIRD REFLECTED CEILING PLANS A212 FOURTH, FIFTH & SEVENTH FLOOR REFLECTED CEILING P A501 ENLARGED PLANS AND INTERIOR ELEVATIONS A601 SCHEDULES & DETAILS E001 ELECTRICAL LEGEND & SCHEDULE E100 FIRST, SECOND & THIRD FLOOR LIGHTING PLANS E101 FOURTH, FIFTH & SEVENTH FLOOR LIGHTING PLANS E200 ELECTRICAL SPECIFICATIONS 1 OF 10 1 ST FLOOR - FIRE ALARM PLAN 2 OF 10 2ND FLOOR - FIRE ALARM PLAN 3 OF 10 3RD FLOOR - FIRE ALARM PLAN 4 OF 10 4TH FLOOR - FIRE ALARM PLAN 5 OF 10 5TH FLOOR - FIRE ALARM PLAN 6 OF 10 6TH FLOOR - FIRE ALARM PLAN 7 OF 10 7TH FLOOR - FIRE ALARM PLAN 8 OF 10 ROOF FIRE ALARM PLAN & BATTERY SCHEDULE 9 OF 10 CALCULATIONS - FIRE ALARM PLAN '10 OF 10 RISER , FIRE ALARM PLAN Grand total; 26 1 1 11/06/2009 LIFE SAFETY + CODE REVIEW REV. NO. I DATE DESCRIPTION Ulm PROJECT STATUS - - - - CONSTRUCTION OWIVI NT PROJECT NAME ONE 7000 PLACE 7000 SW 02 AVE. MIAMI, FL 33143 - COVER SHEET DRAWN CHECKED PROJECT NUMBER JLD JPW 08048 DATE SHEET NO. 07 -08 -2009 GOOO 0 2009 ASKEW NIXON FERGUSON ARCHITECTS INC. I` • •