6840 SW 77 TERR_EB-96-065-002 PROJECT
KITCHEN OR BATH— SMOKE DETECTOR DATE: june 24 96
LROOM LIGHT. NTL A PA' !a bus: 125 A. M.C.B.
120/240 V, 1 0, 3W. REVISIONS
SD
SWkTCH�
120 V CKT P/T W & C DESCRIPTION LOAD CKT # P/T W & C DESCRIPTION LOAD
LINE SIDE
.......... 3 .
bench SWITCH r l
OF SWITCH,. 1 1/15 LIGHTS & REC. .7 2 2 6 4 0
I I 3 4 50 1" C KITCHEN RANGE 4.0
LEG. PHASE CONDUCTOR LIGHTS & REC.
5 LIGHTS & REC. 6 2
NOTE: SPARE
Y
SMOKE DETECTOR SHALL BE HARDWIRED (110 VOLT TYPE) TO A 7 8 20
9 NON—SWITCHABLE KITCHEN OR BATHROOM LIGHTING CIRCUIT, WITH
A..., � 120V. BATTERY BACK—UP AND SHALL NOT BE CONNECTED ONTO THE
LOAD SIDE OF GROUND FAULT CIRCUIT INTERRUPTER. ALL SMOKE LIGHTS & REC. .7 10 2 2.25 NE S DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED. WATER HEATER A . LUGU
•A .
Iin. 11 LIGHTS & REC, .7 12 .30 2.25
S.W.SMOKE DETECTOR DETAIL t THE
NTS I 11
13 2 4.a 14 1/15 —
I-- — — _ ® °—I A/C UNIT
NOTE' 15 60 4.0 16 1/15 .7 H — 1
I� 9 _. s J TYPE ON E120TV.. 1 SHALL ATTERY BACK-UP 17 1/20 SPARE 17 18 .7
WIRED IN ONE ZONE / 1/'15
ONE DETECTOR IN ANNONCING MODE SHALL
ACTIVATE AND SOUND ALL OTHER DETECTORS 19 1/20 LIGHTS & REC. .7 20 1/15 `7
21 1/20 LIGHTS & REC, .7 22
9 23 1/20 LIGHTS & REC. .7 24
r SPARE
' kt
S
TOTAL: 17.8 KVA TOTAL: 14.6 KVA
TOTAL CONNECTED LOAD: 32.4
TOTAL DEMAND LOAD: (SEE LOAD CALCULATIONS)
9 9
9 f LOAD CALCULATIONS:
F
` TOTAL CONNECTED : 32,400 VA
,. - TAT FLORIDA LICENSE
^ - 1a
10 FIRST 1 o,00a @ 100 � �-
10,000
A/C @ 100 % = 8,000 A R - 0 0 1 3 9 8 1
f REMAINDER LOAD @ 40% = 5,760
TOTAL DEMAND PNL "A" 23,760 ./ 240 = 99 AMPS
....... TO F.P.L. SERVICE
1a 9 3 #3/0 THWN IN 2" COND.
°t4 ,
® 200 AMP. PANEL
Qt
Y W/. MAIN. DISC.
pantry
(EXISTING)
# 4 THW CU. IN 1" COND.
db
9 9
PROPOSED
METER --0
ss [
2 5 8" GR
(EXISTING} OUND NEW HOUSE
RODS X 10° @ 6' APART
E" € dryer
9 FOR:
s41.. IN 2 COND.3 #3/0 THW o
washer
� .
dlw.......: 3/4!, C.W.P.
M L....._...,,.._....._._I 9 s M 6840 S.W. 77th TERRACE
_..__,_.._...... ._,....._ 200 A —2P, NE 3R SOUTH MIAMI, FLORIDA
I A/C MAIN DISC. SWITCH
"1 ", 10 Ev"L E C'"Iff"ll m", I UO"AL 'I" I S"El"" IA 0 RA's ff
NTS
9 9
10
ELEC'RICAL N"ES -
slow=
_... F —
s
ALL WORK SHALL CUMPLY WITH CURRENT EDITIONS OF N.E.C. F
E AND S .B.C.
ALL CABLE SHALL BE COPPER UNLESS OTHERWISE NOTED AND APPROVED
INDOORS CONDUIT SHALL BE EMT PROPERTY OF A. LUGOES, R.A.
9 -' OUTDOORS UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC UNDER PAVED AREAS NO PART OF THESE IDEAS, PLANS OR DESIGNS MAY BE
ELECTRICAL CONTRACTOR SHALL FURNISHED ALL LABOR, MATERIALS AND EQUIPMENT FOR A COMPLETE REPRODUCED OR COPIED UNLESS AUTHORIZED IN WRITING.
WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE
10
ELECTRICAL INSTALLATION IN ACCORDANCE WITH THE APPROVED DRAWINGS AND SUBSIDISRY PERMIT PRECEDENCE OVER SCALE DIMENSIONS.
A. LUGONES, R.A.., ASSUMES NO LIABILITY FOR THE UNAUTHO-
ELECTRICAL CONTRACTOR TO PROPERLY COORDINATE ALL OUTLET LOCATIONS RIZED USE OF THESE DRAWINGS AND SPECIFICATIONS OR
9 ELECTRICAL CONTRACTOR TO PROVIDE EMPTY CONDUITS FOR TELEPHONE AND T.V. ANTENA FOR ANY VARIATION FROM THE ORIGINAL DOCUMENTS.
9 ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR
.'........".........._............:................. ALL LIGHT FIXTURES, FANS AND SPECIAL ELEMENTS AS SELECTED BY OWNER
11
IMPORTANT:
SCALE: 1/4"=1'—Op GENERAL CONTRACTOR IS TO BE RESPONSIBLE FOR CALLING
THE ARCHITECT WHEN CERTIFICATIONS AND/OR SPECIAL
INSPECTIONS ARE RE 'D. BY COUNTY OR CITY REGULATIONS®
SAID INSPECTION AND/OR CERTIFICATIONS ARE NOT PART
OF THE SERVICES INCLUDED WITH THE PRODUCTION OF THIS
PERMIT SET OF WORKING DRAWINGS.
CALL THE ARCHITECT WITH 72 HOURS IN ADVANCE, ALWAYS BEFORE CALLING BUILDING DEPARTMENT INSPECTOR.