6611 SW 78 TERR_EB-09-015-016 ELECTRICAL LOAD CALCULATIONS REVISIONS
PANEL A ` ` L)
SERVICE: / 1. GUARANTEES D RESPONSIBILITY: ALL MATERIAL AND WORKMANSHIP FOR ONE T F CONTRACTOR
;
« ®/9� I7 . . I L A° Y FROM DATE OF ACCEPTANCE. ALL DEFECTS SHALL BE CORRECTED WITHOUT 1. V{ ALL U Q L FIXTURES. T F PLATES,
MOUNTING: SURFACE (ALL 20 AMPS, CHARGE, INCLUDING ALL PATCHING AND PAINTING AND OTHER INCIDENTAL REPAIRS RECEPTACLES , DIMMERS ANDS ITCHES.
SQ. FT 21840 1 L L OR REPLACEMENT. COLOR & FINISH TO BE SELECTED BY OWNER COORDINATE
• VERIFY / .
2• WORKMANSHIP: ALL WORK SHALL BE INSTALLED IN A NEAT, ORDERLY MANNER.
DEVICES, PLATES, EXPOSED RACEWAYS, ENCLOSURES, COVERS, FIXTURES, ETC. SHALL
SMALL APPLIANCES 2 0 0 0 N N REMARKS REMARKS N 0 N 0 < E IGNED PERPENDICULAR TO OR PARALLEL WITH, PRINCIPAL STRUCTURAL 2• COORDINATE TELEPHONE LINE SERVICE CONNECTION
4,500 WITH LOCAL TELEPHONE COMPANY COMPANY OWNER.. THIS
MEMBERS. THE EDGE OF THESE COVERS, PLATES ENCLOSURES, ETC., SHALL BE IN
RANGE & OVEN
s 1 1/ 1 L LIGHT 1 2 L LIGHT 1 1/ 1 VERTICAL OR HORIZONTAL PLANE AS APPLICABLE FOR THE ITEMS INVOLVED. EXPOSED INCLUDES UlPM T LOCATION, SPEC f T
1 1/ 1 L LIGHT 3
RACEWAYS SHALL BE OFFSET WHERE THEY ENTER SURFACE—MOUNTED
REFRIGERATOR 20 L LIGHT 1 1/ 1 EQUIPMENT. WIRING INSTALLED IN PANELS AND OTHER ENCLOSURES SHALL BE
___ 17000 T 1 1/2 1 L LIGHT 5 6 DISPOSAL 1 1/ 0 1 NEATLY LOOPED AND LADED NOT WADDED OR BUNDLED.
MICROWAVE 12000 — :1
c1*4 LO
15 1 800 1/2 14 REFRIGERATOR 7 R BATH GFI 12 1/2 1500 1 20 3. MATERIAL STANDARDS: ALL MATERIALS SHALL BE NEW & CONFORM TO THE
WASHER 1 ,250 60 2 10,500 / IL#1 9 10 APPLICABLE STANDARDS WHERE SUCH HAVE BEEN ESTABLISHED FOR THE MATERIALS a
RANGE 6 3/ 1 IN QUESTION. THE PUBLICATIONS AND STANDARDS OF THE ORGANIZATIONS BELOW
11 12 ARE APPLICABLE TO THE MATERIALS SPECIFIED HERE IN. CO E
RECEPTACLE 1 ,960 60 2 3,500 3/4 6 Cu #1 13 14 1 /4 5,000
A. AMERICAN SOCIETY FOR TESTING AND MATERIALS ( M)
cf) CD
HYDRO TUB 15 16 B. UNDERWRITER'S LABORATORIES, INC. (UL)
C. AMERICAN STANDARDS ASSOCIATION ( )
HOOD 200 a 1,500 1/ 1 17 1 D. NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA)
19 20 A.F.C.I. 12 1/2 1 20 E. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
WINE COLLER 1 ,200 20 1 1/2 1 A.F.C.I. 21 22 A.F.C.I. 12 1/2 1 20 WHERE REFERENCE IS MADE TO TRADE NAMES OR NAMES OF MANUFACTURERS, SUCH LL
DRYER BOOSTER 400 20 1 1/2 1 A.F.C.I. 23 24 RECEP & LIGHTS 12 1/2 # 1 20 REFERENCES ARE MADE SOLELY TO DESIGNATE AND TO IDENTIFY THE QUALITY OF THE 00 uj
MATERIALS OR EQUIPMENT TO BE FURNISHED, AND DOES NOT PRECLUDE THE USE OF
DRYER 27500 1, 1/ 1 DETECTOR ,f 25 2 LL APPLIANCES .I 1 1/2 1, 1 "EQUAL" EQUIPMENT AS APPROVED BY IS ENGINEER, a
1 , / 1 I LL APPLIANCES 7 2� LI 1 1/ 1
DISHWASHER
4. REFERENCE STANDARDS: INSTALLATION SHALL COMPLY WITH THE
1 ,500 15 1 380 1/2 1 2 EXT.RECEP.&LIGHTS 29 1 30 GARAGE DOOR 12 1/2 1,600 1 REGU TIONS OF THE FOLLOWING:
SMART PANEL FEED 1 ,500 20 1 1/2 12 EXHAUST FAN 31 32 RECEPTACLES 1 1/ 1, 1
2 1 1/ L LIGHT 33 34
GENERAL LIGHT T 1 1/2 1 A. NATIONAL ELECTRICAL CODE (NFPA), LATEST EDITION
DISPOSAL
B. FLORIDA BUILDING CODE, LATEST EDITION
' 1/ 1 [ 35 3 EXTERIOR f 1 1/ 1
COFFE SYSTEM
. DO NOT SCALE ELECTRICAL DRAWINGS. REFER TO PLANS AND ELEVATIONS FOR
BATHROOM (GFI) 1 ,500 f 1 ,500 3 , 3/4 1 T 7 36 f 1 1/2 1,500 E GT LOCATION OF L EQUIPMENT. CONFIRM WITH OWNER'S PREVENTATIVE.
39 4
SPARE 1 42 . THE MINIMUM WIRE SIZE SHALL E 12 AWG, UNLESS OTHERWISE NOTED.
CONNECTED LOAD: (SEEL OAD ALL CONDUCTORS SHALL BE COPPER WITH TW INSULATION FOR SIZE #8 AND
L CULA T/ON) FEEDER SEE RISER SMALLER. CONDUCTORS LARGER THAN #8 SHALL HAVE TYPE THE INSULATION,
FED FROM: UNLESS OTHERWISE NOTED. ALL CONDUCTORS #10 AND SMALLER MAY BE SOLID
SERVICE
AND ALL THOSE #8 AND LARGER SHALL BE STRANDED.
FIRST 1OKW @ 100% 7. ALL RACEWAYS AND PIPES PLACED IN OR THRU A CONCRETE SLAB SHALL
10,000 BE SPACED A MINIMUM OF 3 DIAMETERS OF THE LARGEST CONDUIT OR PIPE OF ANY
OTHER SERVICE.
A/C OR 8. ALL RACEWAYS SHALL BE CARLON PY—DUIT, TYPE A, Ul. LISTED OR
Q 18,240 EQUAL. CONDUIT FITTINGS AND CEMENT SHALL BE PRODUCED BY THE SAME
DEMAND LOAD: 39852 MANUFACTURER.
s
A. RUNS IN CONCRETE IN CONTACT WITH TH, UNDERGROUND, POSED OR IN
BREAKER SIZE 200 INTERIOR WALLS OR FEEDERS 1 1/4" OR LARGER, SHALL BE RIGID STEEL OR PVC
B. METALLIC ELECTRICAL CONDUIT OR ROMEX MAY BE USED IN THE INTERIOR
PARTITIONS AND CEILINGS. CO
PANELA . OUTLET BOXES SHALL BE POLYVINYL CHLORIDE AND SHALL CONFORM TO THE
N.E.MA• STANDARDS.
NEUTRALLOAD WATTS 10. THE DISCONNECT SWITCHES SHALL BE HORSEPOWER—RATED HEAVY DUTY, 00 LL
QUICK—MAKE/QUICK—BREAK IN N.E.M.A.-1 INTERIOR,4 EXTERIOR.
s s
APPLIANCES 147270 11. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF
CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH & INSTALL ALL ITEMS uj <
FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS FOR THE
EQUIPMENT TO BE PLACED IN A PROPER WORKING ORDER. SHOULD ANY ITEMS U) 2
BALANCE @ 35% 3,945 BE MISSING, HE SHALL NOTIFY THE ARCHITECT/ENGINEER BEFORE COMMENCING WORK.
NO ADDITIONAL PAYMENT WILL BE MADE FOR THE CONTRACTOR'S FAILURE TO NOTIFY CD
RANGE @70% s
THE ARCHITECT/ENGINEER.
EXTERIOR LIGHTING & co 0
ELECTRICAL NOTE.S,-. co cn
RECEPTACLES s
1. OUTSIDE RECEPTACLES, RECEPTACLES AT BATH, GARAGE AND KITCHEN COUNTER,
SHALL BE G.F.I.
BATHROOM (GFI) 1 500 2. SMOKE DETECTOR HARDWIRED TO KITCHEN OR BATHROOM NON—SWITCHABLE NO G.F.I.
s LIGHTING CIRCUIT INTERCONNECTED AND WITH BATTERY BACK—UP.
DISHWASHER 1 ,500 3. ELECTRICAL METER AND PANEL LOCATION MAY VARY AS PER SERVICE ENTRANCE
LOCATION.
4. ELECTRICAL CONTRACTOR TO COORDINATE SERVICE WITH F.P.L.
. ALL "J" BOXES SHALL COMPLY WITH N.E.C. 314
. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD ELEVATION
120V. APPLIANCES 19600 SHALL BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED
ON (SEPARATE) INDEPENDENT CIRCUITS FROM THOSE IN THE HABITAT AR
7. NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD
TOTAL NEUTRAL ELEVATION.
W..'
g ' 8. IT IS SUGGESTED THAT YOU CONFER WITH FLORIDA POWER AND LIGHT TO LOCATE THE
NEUTRAL AMPS ELECTRICAL METER TO COMPLY WITH FEDERAL EMERGENCY MANAGEMENT AGENCY
(N.W./208) 96 REQUIREMENTS
GROUNDING
ELECTRODE
CONDUCTOR
1-1 � BOLTED-TYPE
CONNECTION DEVICE
3 OR EXOTHERMIC WELD.
0
SD GROUNDING 0 NONMETALLIC
ELECTRODE PROTECTIVE
NEMA 3R 10,040 A/C KITCHEN OR SLEEVE.
2 I ^�: - '.r. 'tee.. •.pa,. ..q°.:..:..;.. :rt'- rt:..y..
,.v ♦ty
Y
:x e.
c° t
V51'e
k;
I
N FPL SERVICE CONNECTION ELECTRICAL t
PANEL q ° a. q n+ a ° • " *
CONTRACTOR MUST CONTACT FPL FOR SCHEDULE Q DE 0 <.
CONNECTION REQUIREMENT INCLUDE IN BID L ' I rL q ••C®NC:RETE FOU L7ATION«4` COPPER CONDUCTOR OR STEEL:No.4 AWG OR LARGER BARE
I qm
9 I q . , q e
NECES Y WORK ®®.-d a.-a
®._ _®_a—
L—m ®--_---®®•.�, —,�---®---®_®—®—®—,�®—.._ 2 e s® . 4 � .,q LE
SS ® ANNi-INC RDIAMETER.OT FDATE
TO FPL 1
• a
q • .4 ° .'ad ..
E LOCATED INSIDE .« « 4° a•
a s 20 in. q ®« 4 •. d9.
6
r
GARAGE I MIN. a s q Qa q q
SCALE
1-1l2° 3 0 THVVN I I m q
AS SHOWN
1-1 3#2/0THWN a i i :•: 20 .'. . DIRECT CONTACT LLJ
r w o MIN. WITH EART, . L.
I F
1
DRAWN
1#4 -3/4-(GND) i L.T.
h
[ GROUNDING-
CONNECT TO C8 °x10'GROUNDING RODS SPACED .
'BOND TO A 3/4"COPPER WATER PIPE STUB—OUT AT
METER LOCATION&ENCASED GROUND SEE DETAIL. ELEuom%TRODE DETAIL
I
CONNECTION DETAIL
® e N.T.S.
.�
ELECTRIC RISER DIAGRAM
_
SCALE: N.T.S.
LSHEET 2 OF 2