07-1196-079LEAD CAP i IN. _\ DOWN INTO PIPE jA 2 INCH MIN USE LEAD CAPS FOR VENTS WITH LESS THAN 2 INCH PERIMETER MULTIPLY ROOFING ROOF DECKING NOTE: VENTS SHALL TERMINATE 1" ABOVE PARAPET WALLS. �- ROLLED LEAD FLASHING 1 IN. DOWN INTO PIKE PLUMBING VENT STACK MASTIC SEAL AT PERIMETER 4 IN. MIN. <_'�_ . *go . f . • • Y • •f Y •YGVr ••• 000 • M (u a r• r w W • "ERICO" STANDARD STRUT CLAMP • r s • r • r• r Y • • • • rh :Y r r t li• • • SUPPLY PIPE ON ROOF "' ° •" ' • rr•Y ••rfY ,•• •ffr - r • c, ` t " s r r • :0000 • t • r / r r • a • � • ..•. . r•r•r . WO •••Y M 6" MINIMUM �� '� ROOF "ERICO" POLYETHYLENE FOAM BLOCK SIZE VARIES "ERICO" INTEGRAL STRUT CHANNEL 4" MINIMUM INSTALL "ERICO" PIPE PIER SUPPORTS AT 6' -0" O.C. AND AT ALL FITTINGS AND ELBOWS DETAIL SCALE 15,� DETAIL SCALE 11� VENT THRU ROOF DETAIL SCALE ROOF PIPE SUPPORT DETAIL SCALE NON NONE NONE NONE TA �l 1/2' CHROME PLATED TRAP PRIMER LINE 1/2' x 12' FRESH WATER MAKE -UP LINE 'iCplilw1Zui1 11/2* X 12" 17 GAUGE FLUSH VALVE PRIMER TUBE WITH 3/8" COMPRESSION FIMNG WATER CLOSET FINISHED WALL 1/2" CHROME PLATED TRAP PRIMER LINE 1/2• X 12' 1/2" IPS SHALLOW CHROMED FLANGE BY OTHERS STUD WALL HYCO STRA NAILED TO 1 IP1T Al lr% f%f%l r% %A /ATrrf STU D WALL FLOOR DRAN FINISHED FLOOR `-- THREADED END-/ Lv__l 1/2. OD COPPER MAKE -UP WER GASES WATER LINE SE HYCO 90' BELOW WATER SEAL SECURED TO STRAP (TYP) P -TRAP SCALE SCALE SCALE SCALE DETAIL NONE 14 DETAIL NONE L101 TRAP PRIMER DETAIL N N 6 PIPE SUPPORT DETAIL 7r3l -_ 0 E NONE DETAIL SCALE NONE DETAIL OPEN TEE DRAIN LINE TO BE SLOPED AC -1 1/4" MIN. PER FOOT. A - —% FLASH AND COUNTER FLASH THRU ROOF (UNO) NOTES: A. FILL TRAP MANUALLY ON INITIAL START —UP. B. TRAP EACH COMPONENT DRAIN CONNECTION. C. PIPE SIZE SHALL NOT BE LESS THAN DRAIN PIPE CONNECTION SIZE. A = NEG. S.P. = 2" B =(2X NEG. S.P.) =4" ALL CONDENSATE PIPING TO BE COPPER (UNO). DETAIL SCALE CONDENSATE DRAIN DETAIL NONE NEW 4" STAINLESS STEEL INTAKE ABOVE CEILING 3 /4 "HWR 11/4"(300) 11 /2 "HW SCALE NONE 12,� DETAIL Na`N 8 CEILING 11/2 "CW 11/2 "CW BY —PASS VALVES FOR FUTURE SOFT WATER EQUIPMENT _ 11/2 "SOV do UCHECK VALVE 101 AMTROL No ST -12 EXPANSION TANK WH 1 AMTROL No "HB" 3/4" BRONZE tP BODY & FLANGES, 27 GPH 0 101 12 FT. HEAD, 1/16 HP, 1750 11 /2 "CW RPM, 115 V., 1 PH, 60 HZ 3 /4 "SOV k CHECK VALVE INSTALL NEW WATER HEATER ON WALL MOUNTED PLATFORM ABOVE NEW MOP SINK TWO TIMES FOOD SERVICE -� PIPE SIZE EQUIP. DRAIN AIR GAP r-t=7 I I l..—J1 FLOOR SINK FINISHED FLOOR SCALE 5 INDIRECT WASTE DETAIL NONE —NEW 4" STAINLESS STEEL EXHAUST ABOVE CEILING NEW CONCENTRIC VENT KIT WITH HORIZONTAL TERMINATION. CEILING EXISTING EXTERIOR WALL SECURE TO WALL WITH 18 GAUGE X 1-1/2' WIDE GALV. SHEET METAL STRAPS SECURED TO STUDS WITH 1/2" DIA. X 2" LAG BOLTS — TYP TWO STRAPS — ONE AT TOP 1/3 OF TANK AND ONE AT BOTTOM OF TANK. ROUTE T.P.R.V. DRAIN FROM WATER HEATER MOP SINK BELOW WATER HEATER WITH LEGAL AIR GAP. ROUTE DRAIN FROM WATER HEATER DRAIN PAN TO MOP SINK BELOW WATER HEATER WITH LEGAL AIR GAP. MIN, 6" ABOVE FIN. FLOOR SCAL,E___l NONE � CRO ENGINEERING GROUP, INC. 18652 Florida Street, Suite 150 Huntington Beach, CA 92648 P (714)847 -7100 F (714)841 -6000 SCALE NONE ri RA 5U5H1 CORPORATION 5COTT5DALE, AZ ■ 12 -22 -OG V J C) O Q z O �►���ol ❑ 06. 15.07 15t LANDLORD 5U6MITTAL ❑ 08.21 .07 15t CITY 5UBMITTAL ❑ 02.07.08 2nd CITY SUBMITTAL ❑ DATE 5829 5W 73RD 5T SOUTH MIAMI, I'L f�