07-1196-0760000 ••• . . w�'... . •.
WH
. - - - a e • 000.0
16
------------- - - - - -- - PLAN NOTES
- -' �� ;•, 10 22 1 24 2 3 2Fi 4 28
�___ 3/4" GAS TO OPEN BURNER - ITEM J22 (112 CFH).
Y • 3
21_/2
314 GAS TO BROILER ITEM X24 (60 CFH). ., ... • ... • . • . . , .
- I C_........_ —.__. � �..J' \.._.; I! � ._....___�_ ...,. _.�' s,,.,. _..._ :; .. _.._....:.... _. t� -iii - - �� I, - • • • •
" 0000 •• : •
GAS._DN: i i 4 GAS TO FRYER -- ITEM 26 ZRO CFH
! i � ! ..__li � � . . . . ..._,__._._. _._...__.___. ....._.._ ' ) ' i .' ' + ` /. "} �� � I f i,, d � ' f � . y}� I I f l , 1 1 , 1 1 1 1 ] I ! . y l i -i. "!" I ' . I I I t . . � 4 .' " ..,� � r • Y Y s • Y veto • • • • • D& , • •
\'; 1 2" T RICE _
• /
GAS 0 E COOKER ITEM #23 (35 CFH).
(� 2 "(400) + 21/z ( ) == —= -- • -� 5 3/4" GAS TO CONVECTION OVEN - ITEM f32 (28 CFH).
2" GAS • +67" A.F.F. TO NEW WATER HEATER (400 CFH).
11/2 GAS PIPING UP (270 CFH) - SEE SHEET P -5 FOR CONTINUATION.
I 1
n 21 2"
GAS COCK k ELECTRIC SOLENOID VALVE INSTALLED MOVE CEILING FOR HOOD FIRE MtOTECTION
� I
fi -�I ! SYSTEM - L/15EL CEILING TILES "HOOD VALVES ABOVE CEILING ".
_._ �. -- - - - - -- =- - - � - ' RA SUSHI CORPORATION
�:.. W—= - -,. - - - - -- ---- - - - -_. _.— __ _ __ _ ,2 (7 TON r.....�..� -�/ I,�r L J._ - _ _ —� I y
-:� _ - -__ ___.._._ —_ L� -__ _.__ -.__ _. ____._._.___. 1 _I ^ -- 1 _ I �J 1 EMERGENCY DRAIN TO FAN COIL PAN ABOVE CEILING. SCOTTSDALE, AZ
I �1 i r ,
1" EMERGENCY DRAIN ON. -� SPILL DIRECTLY ABOVE SINK.
1 j�i I 11 1" CONDESATE DRAIN TO FAN COIL ABOVE CEILING.
I
I
1" CONDENSATE DRAIN ON TO FLOOR SINK WITH 2" AIR GAP (7 TONS). - U�,
_ f )
15 TONS !
- 13 1" CONDENSATE DRAIN ON TO FLOOR SINK WITH 2" AIR GAP (18 TONS). �
11 (s TON��I I!
I 1 /2 (270) L_ _ r�'� r y li ! I ! 14 MECHANK,AL E UIPMENT IN CEIllNG SPACE -SEE MECWINICAL DRAWINGS. �' � ^ •
I I ( ✓� 1� � �� y� >.� �_ ii Q �i�y �� .�C P� �p1�1��''*�i
ailc n •
, r`� I
_�_ CD �' 1�, r �� I { I v -� 'I ' I r CONDENSATE DRAIN UP SEE SHEET -5 FOR CONTINUATION. , r ', ;{�` E �
" \ 15 ii/
ED " — 1 ' `,_ : �_. _..___ / �;' _ _.._.._'.__...________,_. _ y , 1` SWEET P -6 FOR DETAIL OF EXACT ROUTING OF SEALED DIRECT VENT WITH CONCENTRIC VENT (� M
TERMINATION.
I y <•„ \ b
y
8 17 21/2 GAS PIPING ON TO FULL SIZE GAS HEADER ALONG WALL (662 CFH).
POC OF NEW 3" GAS INTO EXISTING 3" GAS ABOVE CEILING - CONTRACTOR SHALL FIELD VERIFY EXACT
10 14 10 \ , , /, I LCCATION, SIZE, AND CONDITION OF EXISTING 3 GAS PRIOR TO THE START OF ANY NEW WORK AND
SHALL IMMEDIATLIY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
■ 1 2.22 -0G
v/ \�
1
\\ /�
L
1
11f4" /��
�-JI+ + } I
r r ! I -- - - --
-
I !
C>
I
0
0!
Cz
0
0
c�
_
LL-
'��� --
I
:
J
\,
�jI // I
0 <
it j j I
CT
C.
_ --
-- G - - -- --- - - - - -- c
I ,
I z
III
P. I !�
� •ee,....e27" € I
I ,
n C C7 I C I
r C7
- - G ' I CONDENSATE SIZING TABLE
■I REVISIONS
I
:
I
I
Jv i I / <> ' I ,, -- PI_ PE SIZE P I I ❑ OG. 15.07
_ - - - - -- - - - - -'— - - ��- -- _ _- -..I _
_ _ -- _ - _ _ _ _ -- 1 ___.
N
i -- --� — _ - �= -�. �J���L� �- -... _ �. v y - -- — T -, — -- �� - — -
� / » 15t LANDLORD SUBMITTAL
_- ...__. ______ . / � I > '� � � I 3 4 UP TO 3 TONS
1" 4 To zo TONS ❑ 08.21 .O7
I � .
i1/4" 21 TO 90 TONS 1 5t CITY SUBMITTAL
11/2» 91 TO 125 TONS ❑ DATE
� I
2" 126 TO 250 TONS ❑ DATE
GENERAL NOTES
1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS & EXACT SIZE, DEPTH, LOCATION, tt CONDIT'ION
OF ALL EXISTING UTILITIES PRIOR TO THE START OF ANY NEW WORK - CONTRACTORS BID SHALL REFLECT
r ALL EXISTING SITE CONDITIONS. 5829 SW 73RD ST
2. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF ANY NEW WORK. SOUTH MIAMI, EL
_ ___. ____ 3. PROVIDE QUICK DISCONNECT SWIVEL GAS HOSES AT ALL GAS FEED MOVABLE API'L-IANCES.
CRO ENGINEERING
GROUP, INC.
NORTH
18652 F'laftda Street, Suite 150 GAS % C�gATE
Huntington Beach, CA 92646
I - SCALE P 71� a47� -7100 F'1'�Vi..AN
GASA PIPING FLAN n ,_ n F 714841 -6000 1 4 -- 1 f)
'
� I