07-1196-07514 PL
10 C22 1 24 2 3 26 4 28
— - - -- w
❑
7 21 2" 21 2 _ —21 2" 21 2"
-6- __— - -- — -_ -- - -�- T - ❑
" _ 3 Ts
—
2-(400) II II 21 s7a f- 0
f J il••i"
A1ri • • 444 . i •
_AN NOTES • . Y •••••
• • s • Y n i •
1if •i• • i • 1i4 • Y i
f . f
3/4" GAS TO OPEN BURNER — ITEM #22 (112 CFH). •" W • ••"
• i r s �� Y r
3/4" GAS TO BROILER - ITEM 124 (60 CFH).
11/4- GAS TO FRYER — ITEM #26 (280 CFH). • • • i • • . • . • • f r
r • • r • r
1/2 GAS TO RICE COOKER — ITEM 128 (35 CFH). : • . r • . � • . • "• , • • • • ,
3/4" GAS TO CONVECTION OVEN — ITEM f32 (28 CFH).
9 B 2" GAS 0 +67" A.F.F. TO NEW WATER HEATER (400 CFH).
11 ❑
- _ — - - -- -- 11/2" GAS PIPING UP (270 CFH) -- SEE SHEET P -5 FOR CONTINUATION.
Air, 21 2" GAS / COCK k ELECTRIC SOLENOID VALVE INSTALLED ABOVE CEILING FOR HOOD FIRE PROTECTION
- — SYSTEM —LABEL CEILING TILES HOOD VALVES ABOVE CEILING ".
- RA SUSHI CORPORATION Ida
_ 12 (7 TONS
_ - - - - - -_ El 1" EMERGENCY DRAIN TO FAN COIL PAN ABOVE CEILING. SCOTTSDALE, AZ
•
El in EMERGENCY DRAIN DN. — SPILL DIRECTLY ABOVE SINK.
11 1" CONDESATE DRAIN TO FAN COIL ABOVE CEILING.
- -- FI
12 1" CONDENSATE DRAIN DN TO FLOOR SINK WITH 2" AIR GAP (7 TONS). t4
FC 11 (9 TO [ s 2 FC_2 LC 9 TONS) 13 1" CONDENSATE DRAIN ON TO FLOOR SINK WITH 2" AIR GAP (1i TONS). T 1 /2 "(270) -�
/� ��i✓ 1 "
- 14 MECHANICAL EQUIPMENT IN CEILING SPACE — SEE MECHANICAL DRAWINGS. R Ip�
CD I a 15 11/4 CONDENSATE DRAIN UP — SEE SHEET P -5 FOR CONTINUATION. �F� E D V"
ED " a 1• -- 1G SEE SHEET P -6 FOR DETAIL OF EXACT ROUTING OF SEALED DIRECT VENT WITH CONCENTRIC VENT
TERMINATION.
C) ) " - - - -- 17 21/2" GAS PIPING DN TO FULL SIZE GAS HEADER ALONG WALL (662 CFH).
" 1a POC OF NEW 3" GAS INTO EXISTING 3" GAS ABOVE CEILING — CONTRACTOR SHALL FIELD VERIFY EXACT
71 (S TONS) 14 10 LCOATION, SIZE, AND CONDITION OF EXISTING 3" GAS PRIOR TO THE START OF ANY NEW WORK AND
h SHALL IMMEDIATLEY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
IN 12 -22-OG
-0- Li TT
uuuuu
�J
C00O 000 0000
_
0 0 0 0 0 00
0
°
°
o CZ
0 o
C 11/2 "(270) 11/4" 0 — -
C 0-
- ° LL
r o
0
o _
Elf p rl ._ - -- - Ll o Z
o
0
0
— J
-� ��
0
0 o 0 °o 0 o
-
00 0 0 0 --
__- -
F 7=1
'j
------------
____ - -- 11 2„ 270 1174' � _ 00 0
0 0 n °o U U 0 0 0 °° 0 o o -- CONDENSATE SLING TABLE ° ■ REVISIONS
o°
oo' -
o PIPE SIZE CAPACITY IN TONS OF REFRIGERATION 11 OG. 15.07
BMITTA
- - -- -- SU
- - -- --- ' - - - - -- L
❑ 08.2 I .07
4 TO 20 TONS
15t CITY SUBMITTAL
11/4 21 TO 90 TONS ❑ 02.07-05
11/2" 91 TO 125 TONS 2nd CITY SUBMITTAL
2" 126 TO 250 TONS ❑ DATE
GENERAL NOTES
1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS is EXACT SIZE, DEPTH, LOCATION, k CONDITION
OF ALL EXISTING UTILITIES PRIOR TO THE START OF ANY NEW WORK — CONTRACTORS BID SHALL REFLECT
ALL EXISTING SITE CONDITIONS. 55829 5W 73RD 5T
2. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF ANY NEW WORK. SOUTH MIAMI, FL
3. PROVIDE QUICK DISCONNECT SWIVEL GAS HOSES AT ALL GAS FEED MOVABLE APPLIANCES.
a
•
MINIBOOM
.__ __._ —____ CRO ENGINEERING GROUP, INC.
NORTH
-- ....._.______.____ _ 18652 Florida Street, Suite 150 (•'A$ & CONDENSATE
Huntington Beach, CA 92648 PSG
SCALE P �77144r47-7100 PLAN
GAS & CONDENSATE PIPING PLAN F 141 -6o0n