07-1196-042SPST N.O. RELAY 0 LL1— INTERLOCK CIRCUIT STARTS BLOWER MOTORS FOR FC -1 THRU 3 TO PROVIDE 100: MECHANICAL INTERLOCK FOR EXHAUST AND MAKE -UP AIR Cd� m 208V -3 0 �4 --- - - - - -� FAN SECTION FROM LOAD SIDE OF EXH FAN MAGNETIC MOTOR STARTER EXHAUST FAN ►TE: CONTRACTOR TO VERIFY ROUTING REQUIREMENTS OF i TE & LOW VOLTAGE WIRING FOR EF -1 0 ?-i R ------- _� R-------- - - - - -- (2) -116, IN CONDUIT FROM � PQTO REMOTE SENSORS 208V -3 0 C.B. IL aE D.S. 20aV -3 d aECB. .D.S. 208V -3 0 MOUNT SYSTEM MANAGER �1 INSIDE MUA -t CONTROL RETU OUTSIDE AIR C B PANEL & SET COOLING TO BAR 78' F/ 507. H do HEALING WD.S. TO 65' F FC -2 DINING i 2200 <1800> TO SMOKE DEFECTOR FC -3 KITCHEN CIRCUIT, SEE DIAGRAM 2400 <600> TYPICAL MUA -1 Cd� m 208V -3 0 �4 --- - - - - -� FAN SECTION FROM LOAD SIDE OF EXH FAN MAGNETIC MOTOR STARTER EXHAUST FAN ►TE: CONTRACTOR TO VERIFY ROUTING REQUIREMENTS OF i TE & LOW VOLTAGE WIRING FOR EF -1 0 ?-i R ------- _� R-------- - - - - -- (2) -116, IN CONDUIT FROM � PQTO REMOTE SENSORS 208V -3 0 C.B. IL aE D.S. 20aV -3 d aECB. .D.S. (5) - #16, IN CONDUIT FROM ACP T REMOTE SENSORS (10) -116, IN CONDUIT FROM AY T CP REMOTE SENSORS 208V -1 0 DPST N.O. RELAY BY E.C. (1/2- HP EXHAUST FAN /MUA 120V -1 0 -- L1 - SPST N.O. RELAY HP- 1 /FC -1 BAR EF -2 0 DISHWASHER HOOD 1 ZUV -1 0 BY E.C. TO HOOD FIRE SUPPRESSION SYSTEM INTERLOCK SWITCH FILTER SECTION ------------------ - - - - -j EF SMOKE DETECTORS FUI INSTALLED BY THE MEI CONTRACTOR, WIRED B ELECTRICAL CONTRACT( (TYP OF 3) 120V -1 0 SPST N.C. RELAY TO HOOD FIRE SUPRESSION BY E.C. SYSTEM INTERLOCK BY E.C. Q (ACTIVATION OF 'ANSUL" SYSTEM SHUTS DOWN MUA -1, MUA -2 & FC -1 THRU 3 aco 120V -1 0 72' HP -3 FC -3 L KITCHEN HP--2 FC--2 DINING EF--3 RESTROOMS NOTE: CONTRACTOR TO VERIFY ROUTING REQUIREMENTS OF ALL LOW VOLTAGE WIRING BETWEEN OUTDOOR AND INDOOR UNITS USTRIES INC. 1605 GENE AUTRY WAY ANAHEIM, CA. 92805 r - ZA TEL: 714- 634 -1771 pa� FAX: 714 -634 -8880 L E MAIL: s stems0 eor ethall.com CONTROL PANELS A /C_ LOGIC AND CONTROL PANEL NTS TO ILLS FIRE ALARM CONTROL PANEL (FIRE /LIFE SAFETY) ntaffl ------ =-(+G 120V -1 0 TO BUILDING FIRE ALARM CONTROL PANEL SMOKE DEFECTOR WIRING DIAGRAM SEE ELECTRICAL DRAWINGS 208V -3 0 120V -1 0 COIL -;- SPST N.Q. RELAY BY E.C. E D.S. - 120V -1 0 HP (1/4 EXHAUST FAN/—EF—\ isov —i e 2 SPST N.O. RELAY BY QC L E D.S. HP (1/6 EXHAUST FAN/ EF 3 GENERAL NOTES 1) ALL WORK AND EQUIPMENT SHALL COMPLY WITH THE LATEST APPLICABLE CODE. 2) ALL FIELD CONDITIONS AND JOBSTTE DIMENSIONS ARE TO BE VERIFIED PRIOR TO THE COMMENCEMENT OF ANY WORK. 3) ALL WORK SHALL BE COORDINATED WITH OTHER TRADES. 4 THE LOCATION OF ALL ROOF PENETRATIONS SHALL BE COORDINATED WITH THE ARCHITECTURAL AND STRUCTURAL DRAWINGS. 5) THE LOCATION OF ALL CEILING AIR DISTRIBUTION DEVICES SHALL BE COORDINATED WITH THE ARCHITECT'S REFLECTED CEILING PLAN AND LIGHTING PLAN. RAL CONTRACTOR 1 PROVIDE ALL LEVEL EQUIPMENT CURBS, RUNNERS AND PLATFORMS TO INCLUDE SHEET METAL CAPS OR LEVELING OF FACTORY CURBS. 2) PROVIDE ALL REQUIRED ROOFING, PATCHING, CUTTING, HEADING, RATED SHAFTS, ACCESS DOORS, FURRING, FLASHING AND PAINTING. 3) SIZE AND LOCATION OF ALL WAG RELATED ROOF, WALL AND CEILING PENETRATIONS TO BE COORDINATED WITH THE MECHANICAL CONTRACTOR 1) PROVIDE ALL REQUIRED DRAINS, GAS, WATER & CONDENSATE PIPING COMPLETE WITH APPLICABLE TRAPS & VALVES. MCTRICk CONTRACTOR 1) SYMBOLS LINE VOLTAGE WIRING, IN CONDUIT E.C. ________ _ _ LOW VOLTAGE WIRING, IN CONDUIT �BY BY E.C. LMINSTALLED EMS FURNISHED AND INSTALLED BY E.C. EMS FURNISHED & WIRED BY E.C. AND BY MECHANICAL CONTRACTOR EMS FURNISHED AND INSTALLED BY THE PWMBIN ►A- CONTRACTOR LINE VOLTAGE CONDUIT AND LINE VOLTAGE WIRING INCLUDING FINAL CONNECTIONS 3) FURNISH & INSTALL ALL LOW VOLTAGE CONDUIT AND LOW VOLTAGE WIRING INCLUDING FINAL CONNECTIONS (LOW VOLTAGE DEFINED AS 24 VOLT CONTROL WIRING) 4) FURNISH & INSTALL ALL FUSES, CIRCUIT BREAKERS AND DISCONNECT SWITCHES 5) NTITRN NE OTGE GSSST CHS S, OCOSINSTALL LINE VLA TA , RELAYS & W E 6) THE WIRING DIAGRAMS ARE SCHEMATIC, INTENDED TO SHOW SEQUENCE AND METHOD OF OPERATION. ALL ELECTRICAL WORK TO COMPLY WITH ALL LOCAL AND STATE CODES. 7) THE FINAL CONNECTIONS TO EQUIPMENT TO BE RAN IN FLEXIBLE CONDUIT (SEALTTTE OR EQUAL). 8) THERMOSTATS TO BE MOUNTED 0 + 48' AFF, REMOTE SENSORS TO BE MOUNTED 0 + 78' AFF, U.N.O., (VERTICAL BOX) 9) ALL LOW VOLTAGE WIRING TO BE #14 GA. STRANDED, U.N.O. r + EF - 1 COOKLINE FAN ►N SECTION SPRING AIR MODEL NO. KESF40- 57- IH -0S -SN 3982 CFM Q 2.00" E.S.P. 208V -3 0 -60 HZ., 2555 RPM, 7.5 HP TEFC OPERATING WEIGHT = 1690 LBS. FILTER SECTION SPRING AIR MODEL NO. KES40- 57- ISH -ON 115V -1 0 -60 HZ., (FROM FAN SECTION) OPERATING WEIGHT = 850 LBS. SYSTEM ACCESSORIES: PER MMIUFACTURER'S SUBMITTAL DIMENSIONS, (BOTH UNITS; CLOSE COUPLED): LENGTH 11' -2 ", WIDTH 49 ", HEIGHT 42' AFF, (INCLUDES 6" CONCRETE PAD) NOTE: SEE MANUFACTURER'S SHOP DRAWINGS ITEF-2 SERVES DISHWASHER HOOD LOREN COOK MODEL NO. ACRU- B- 120R3B NL2_1 1041 CFM 0 .75" E.S.P, 1/4 HP MOTOR 120V -1 0 -60 HZ., 1435 RPM ACCESSORIES: BIRDSCREEN & BACKDRAFT DAMPER UNIT DIMENSIONS: DIAMETER 2' -6" OPERATING WEIGHT = 100 LBS E EF -3 SERVES RESTROOMS LOREN COOK MODEL NO. ACE- B- 120C3B \ij600 CFM 0 .75" E.S.P, 1/6 HP MOTOR 12OV -1 0 -60 HZ., 1210 RPM ACCESSORIES: BIRDSCREEN & BACKDRAFT DAMPER UNIT DIMENSIONS: DIAMETER 2' -6" F\ OPERATING WEIGHT = 100 LBS MUA -15 SERVES FC -1 THRU 3 AAON MODEL NO. RM- 025- 8- A -BB12 -349: MOOQ- UEO -OEE- 000- PJOOCOF- 00- OAOOOOOAB 324 MBH TOTAL COOLING, 174 MBH SENSIBLE, EER = 11.1 270 MBH INPUT, 218.7 MBH OUTPUT HEATING, (817 EFF) 5000 CFM 0 .75' E.S.P., 849 RPM, 3 HP IFM ELECTRICAL DATA: POWER SUPPLY. 208V -3 0 -60 HZ TOTAL FULL LOAD AMPS: ................................ 123. 00 MINIMUM CIRCUIT AMPACTIY . ...........................135. 00 MAXIMUM OVERCURRENT PROTECTION: ........... 175. 00 ACCESSORIES: PER MODEL NO. SUFFIX PLUS FACTORY SOLID BOTTOM ROOF CURB, ADJUSTABLE PITCH UNIT DIMENSIONS: LENGTH 99" X WIDTH 92' X 67' AFR OPERATING WEIGHT = 3000 LBS. MUA -2 SERVES HOODS LOREN COOK MODEL NO. 120 KSPB 1600 CFM 0 .75" E.S.P, 1/2 HP MOTOR /gU-A\ 208V -1 0 -60 HZ., 808 RPM ACCESSORIES: BIRDSCREEN & BACKDRAFT DAMPER UNIT DIMENSIONS: 60" LONG X 32" WIDE X 40" HIGH OPERATING WEIGHT = 300 LBS BUILDING AIR BALANCE & PRESSURIZATION DATA AIR FLOW CHART UN �1 SUPPLY RETU OUTSIDE AIR EXHAUST FC -1 BAR 4000 1500 <2500> FC -2 DINING i 2200 <1800> 1 FC -3 KITCHEN 3000 2400 <600> MUA -1 FC -1, 2 & 3 5000 0 (5) - #16, IN CONDUIT FROM ACP T REMOTE SENSORS (10) -116, IN CONDUIT FROM AY T CP REMOTE SENSORS 208V -1 0 DPST N.O. RELAY BY E.C. (1/2- HP EXHAUST FAN /MUA 120V -1 0 -- L1 - SPST N.O. RELAY HP- 1 /FC -1 BAR EF -2 0 DISHWASHER HOOD 1 ZUV -1 0 BY E.C. TO HOOD FIRE SUPPRESSION SYSTEM INTERLOCK SWITCH FILTER SECTION ------------------ - - - - -j EF SMOKE DETECTORS FUI INSTALLED BY THE MEI CONTRACTOR, WIRED B ELECTRICAL CONTRACT( (TYP OF 3) 120V -1 0 SPST N.C. RELAY TO HOOD FIRE SUPRESSION BY E.C. SYSTEM INTERLOCK BY E.C. Q (ACTIVATION OF 'ANSUL" SYSTEM SHUTS DOWN MUA -1, MUA -2 & FC -1 THRU 3 aco 120V -1 0 72' HP -3 FC -3 L KITCHEN HP--2 FC--2 DINING EF--3 RESTROOMS NOTE: CONTRACTOR TO VERIFY ROUTING REQUIREMENTS OF ALL LOW VOLTAGE WIRING BETWEEN OUTDOOR AND INDOOR UNITS USTRIES INC. 1605 GENE AUTRY WAY ANAHEIM, CA. 92805 r - ZA TEL: 714- 634 -1771 pa� FAX: 714 -634 -8880 L E MAIL: s stems0 eor ethall.com CONTROL PANELS A /C_ LOGIC AND CONTROL PANEL NTS TO ILLS FIRE ALARM CONTROL PANEL (FIRE /LIFE SAFETY) ntaffl ------ =-(+G 120V -1 0 TO BUILDING FIRE ALARM CONTROL PANEL SMOKE DEFECTOR WIRING DIAGRAM SEE ELECTRICAL DRAWINGS 208V -3 0 120V -1 0 COIL -;- SPST N.Q. RELAY BY E.C. E D.S. - 120V -1 0 HP (1/4 EXHAUST FAN/—EF—\ isov —i e 2 SPST N.O. RELAY BY QC L E D.S. HP (1/6 EXHAUST FAN/ EF 3 GENERAL NOTES 1) ALL WORK AND EQUIPMENT SHALL COMPLY WITH THE LATEST APPLICABLE CODE. 2) ALL FIELD CONDITIONS AND JOBSTTE DIMENSIONS ARE TO BE VERIFIED PRIOR TO THE COMMENCEMENT OF ANY WORK. 3) ALL WORK SHALL BE COORDINATED WITH OTHER TRADES. 4 THE LOCATION OF ALL ROOF PENETRATIONS SHALL BE COORDINATED WITH THE ARCHITECTURAL AND STRUCTURAL DRAWINGS. 5) THE LOCATION OF ALL CEILING AIR DISTRIBUTION DEVICES SHALL BE COORDINATED WITH THE ARCHITECT'S REFLECTED CEILING PLAN AND LIGHTING PLAN. RAL CONTRACTOR 1 PROVIDE ALL LEVEL EQUIPMENT CURBS, RUNNERS AND PLATFORMS TO INCLUDE SHEET METAL CAPS OR LEVELING OF FACTORY CURBS. 2) PROVIDE ALL REQUIRED ROOFING, PATCHING, CUTTING, HEADING, RATED SHAFTS, ACCESS DOORS, FURRING, FLASHING AND PAINTING. 3) SIZE AND LOCATION OF ALL WAG RELATED ROOF, WALL AND CEILING PENETRATIONS TO BE COORDINATED WITH THE MECHANICAL CONTRACTOR 1) PROVIDE ALL REQUIRED DRAINS, GAS, WATER & CONDENSATE PIPING COMPLETE WITH APPLICABLE TRAPS & VALVES. MCTRICk CONTRACTOR 1) SYMBOLS LINE VOLTAGE WIRING, IN CONDUIT E.C. ________ _ _ LOW VOLTAGE WIRING, IN CONDUIT �BY BY E.C. LMINSTALLED EMS FURNISHED AND INSTALLED BY E.C. EMS FURNISHED & WIRED BY E.C. AND BY MECHANICAL CONTRACTOR EMS FURNISHED AND INSTALLED BY THE PWMBIN ►A- CONTRACTOR LINE VOLTAGE CONDUIT AND LINE VOLTAGE WIRING INCLUDING FINAL CONNECTIONS 3) FURNISH & INSTALL ALL LOW VOLTAGE CONDUIT AND LOW VOLTAGE WIRING INCLUDING FINAL CONNECTIONS (LOW VOLTAGE DEFINED AS 24 VOLT CONTROL WIRING) 4) FURNISH & INSTALL ALL FUSES, CIRCUIT BREAKERS AND DISCONNECT SWITCHES 5) NTITRN NE OTGE GSSST CHS S, OCOSINSTALL LINE VLA TA , RELAYS & W E 6) THE WIRING DIAGRAMS ARE SCHEMATIC, INTENDED TO SHOW SEQUENCE AND METHOD OF OPERATION. ALL ELECTRICAL WORK TO COMPLY WITH ALL LOCAL AND STATE CODES. 7) THE FINAL CONNECTIONS TO EQUIPMENT TO BE RAN IN FLEXIBLE CONDUIT (SEALTTTE OR EQUAL). 8) THERMOSTATS TO BE MOUNTED 0 + 48' AFF, REMOTE SENSORS TO BE MOUNTED 0 + 78' AFF, U.N.O., (VERTICAL BOX) 9) ALL LOW VOLTAGE WIRING TO BE #14 GA. STRANDED, U.N.O. r + EF - 1 COOKLINE FAN ►N SECTION SPRING AIR MODEL NO. KESF40- 57- IH -0S -SN 3982 CFM Q 2.00" E.S.P. 208V -3 0 -60 HZ., 2555 RPM, 7.5 HP TEFC OPERATING WEIGHT = 1690 LBS. FILTER SECTION SPRING AIR MODEL NO. KES40- 57- ISH -ON 115V -1 0 -60 HZ., (FROM FAN SECTION) OPERATING WEIGHT = 850 LBS. SYSTEM ACCESSORIES: PER MMIUFACTURER'S SUBMITTAL DIMENSIONS, (BOTH UNITS; CLOSE COUPLED): LENGTH 11' -2 ", WIDTH 49 ", HEIGHT 42' AFF, (INCLUDES 6" CONCRETE PAD) NOTE: SEE MANUFACTURER'S SHOP DRAWINGS ITEF-2 SERVES DISHWASHER HOOD LOREN COOK MODEL NO. ACRU- B- 120R3B NL2_1 1041 CFM 0 .75" E.S.P, 1/4 HP MOTOR 120V -1 0 -60 HZ., 1435 RPM ACCESSORIES: BIRDSCREEN & BACKDRAFT DAMPER UNIT DIMENSIONS: DIAMETER 2' -6" OPERATING WEIGHT = 100 LBS E EF -3 SERVES RESTROOMS LOREN COOK MODEL NO. ACE- B- 120C3B \ij600 CFM 0 .75" E.S.P, 1/6 HP MOTOR 12OV -1 0 -60 HZ., 1210 RPM ACCESSORIES: BIRDSCREEN & BACKDRAFT DAMPER UNIT DIMENSIONS: DIAMETER 2' -6" F\ OPERATING WEIGHT = 100 LBS MUA -15 SERVES FC -1 THRU 3 AAON MODEL NO. RM- 025- 8- A -BB12 -349: MOOQ- UEO -OEE- 000- PJOOCOF- 00- OAOOOOOAB 324 MBH TOTAL COOLING, 174 MBH SENSIBLE, EER = 11.1 270 MBH INPUT, 218.7 MBH OUTPUT HEATING, (817 EFF) 5000 CFM 0 .75' E.S.P., 849 RPM, 3 HP IFM ELECTRICAL DATA: POWER SUPPLY. 208V -3 0 -60 HZ TOTAL FULL LOAD AMPS: ................................ 123. 00 MINIMUM CIRCUIT AMPACTIY . ...........................135. 00 MAXIMUM OVERCURRENT PROTECTION: ........... 175. 00 ACCESSORIES: PER MODEL NO. SUFFIX PLUS FACTORY SOLID BOTTOM ROOF CURB, ADJUSTABLE PITCH UNIT DIMENSIONS: LENGTH 99" X WIDTH 92' X 67' AFR OPERATING WEIGHT = 3000 LBS. MUA -2 SERVES HOODS LOREN COOK MODEL NO. 120 KSPB 1600 CFM 0 .75" E.S.P, 1/2 HP MOTOR /gU-A\ 208V -1 0 -60 HZ., 808 RPM ACCESSORIES: BIRDSCREEN & BACKDRAFT DAMPER UNIT DIMENSIONS: 60" LONG X 32" WIDE X 40" HIGH OPERATING WEIGHT = 300 LBS BUILDING AIR BALANCE & PRESSURIZATION DATA AIR FLOW CHART UN AREA SERVEF SUPPLY RETU OUTSIDE AIR EXHAUST FC -1 BAR 4000 1500 <2500> FC -2 DINING 4000 2200 <1800> FC -3 KITCHEN 3000 2400 <600> MUA -1 FC -1, 2 & 3 5000 0 5000 MUA -2 TYPE I HOODS 1600 0 1600 EF -1 MAIN HOOD -3982 EF -2 DISH HOOD -1041 EF -3 RESTROOMS -600 TOTALS 1 19600 6100 6600 -5623 6600 CFM OSA - 5623 EXH = 977 CFM POSSTTIVE NOTE: MUA -1 PROVIDES 5000 CFM OF PRE - CONDITIONED OUTSIDE AIR TO FC -1 2 AND 3 PER THE QUANTITIES INDICATED IN THE OUTSIDE AIR COLMUME IN C > BRACKETS NOTE: FC -1 THRU 3 SHALL BE EQUIPPED WITH APPROVED TYPE SMOKE DETECTORS INSTALLED IN THE UNITS RETURN AIR PLENUM. MUA -1 SHALL HAVE A SMOKE DETECTOR FACTORY INSTALLED IN THE UNITS SUPPLY AIR PLENUM. UPON DrL ECTOOKI OF SMOKE FRO,! ANY SINGLE DETECTOR, A SIGNAL SHALL BE SENT TO LL'S FIRE / LIFE SAFETY WHEREBY AN ADDITIONAL SIGNAL SHALL BE RETURNED TO THE A/C LOGIC AND CONTROL PANEL SHUTTING DOWN ALL INDOOR SUPPLY AIR FANS. ALL DETECTORS FOR FC -1 THRU 3 & MUA -1 SHALL BE FURNISHED AND INSTALLED, (AS APPLICABLE), BY THE MECHANICAL CONTRACTOR. ALL DETECTORS SHALL BE WIRED BY THE ELECTRICAL CONTRACTOR. HP -1 / FC -1 SERVES BAR HP OUTDOOR UNIT CARRIER MODEL NQ. 38AR0012 112 MBH TOTAL, 90 SENSIBLE COOLING, EER = 10. 1 WITH 95 MBH TOTAL HEATING, (HEAT PUMP), COP = 3. 2 ELECTRICAL DATA: /FC POWER SUPPLY: 208V -3 0 -60 HZ TOTAL FULL LOAD AMPS: ............................... MINIMUM CIRCUIT AMPACITY : ..........................45.00 MAXIMUM OVERCURRENT PROTECTION: .......... 60.00 ACCESSORIES: STANDARD UNIT DIMENSIONS: LENGTH 59" X WIDTH 45' X 42" AFS OPERATING WEIGHT = 600 LBS. INDOOR UNIT CARRIER MODEL NO. 4ORM0012 4000 CFM 0 .60" E.S.P., 2.4 HP IFM, 864 RPM ELECTRICAL DATA: POWER SUPPLY: 208V -3 0 -60 HZ ACCESSORIES: BLOWER CONTACTOR KIT, HEAT PUMP CHECK VALVE KIT AND SUSPENSION KIT. (CONTRACTOR TO PROVIDE 20 VA XFMR) UNIT DIMENSIONS: LENGTH 60" X WIDTH 50' X 28" HIGH OPERATING WEIGHT = 405 LBS. HP -2 / FC -2 SERVES DINING Hp OUTDOOR UNIT CARRIER MODEL NO. 38ARQ012 112 MBH TOTAL, 90 SENSIBLE COOLING, EER = 10. 1 WITH 95 MBH TOTAL HEATING, (HEAT PUMP), COP = 3. 2 ELECTRICAL DATA: FC POWER SUPPLY. 208V -3 0 -60 HZ TOTAL FULL LOAD AMPS: ............................... MINIMUM CIRCUIT AMPACIIY : ..........................45.00 /-F _C \ MAXIMUM OVERCURRENT PROTECTION: .......... 60.00 ACCESSORIES: STANDARD UNIT DIMENSIONS: LENGTH 59' X WIDTH 45" X 42" AFS OPERATING WEIGHT = 600 LBS. INDOOR UNIT CARRIER MODEL NO. 4ORMQ012 4000 CFM @ .60" E.S.P., 2.4 HP IFM, 864 RPM ELECTRICAL DATA: POWER SUPPLY. 208V -3 0 -60 HZ ACCESSORIES: BLOWER CONTACTOR KIT, HEAT PUMP CHECK VALVE KIT AND SUSPENSION KIT. (CONTRACTOR TO PROVIDE 20 VA XFMR) UNIT DIMENSIONS: LENGTH 60' X WIDTH 50' X 28" HIGH OPERATING WEIGHT = 405 LBS. HP -3 / FC -3 SERVES KITCHEN OUTDOOR UNIT CARRIER MODEL NO. 38ARQOOB /HP\ 91 MBH TOTAL 69 SENSIBLE COOLING, EER 10. 4 WITH ELECTRICAL MBH TOTAL HEATING, (HEAT PUMP), COP = 3. 2 ELECTRICAL DATA: /FC POWER SUPPLY: 208V -3 0 -60 HZ TOTAL FULL LOAD AMPS: ........................... ... MINIMUM CIRCUIT AMPACTTY : ..........................39.80 MAXIMUM OVERCURRENT PROTECTION: .......... 60.00 ACCESSORIES: STANDARD UNIT DIMENSIONS: LENGTH 60' X WIDTH 45' X 40' AFS (INCLUDES 6" HIGH CONCRETE PAD) OPERATING WEIGHT = 464 LBS. INDOOR UNIT CARRIER MODEL NO. 4ORMQOO8 3000 CFM 0 .60" E.S.P., 2.4 HP IFM, 740 RPM ELECTRICAL DATA: POWER SUPPLY: 208V -3 0 -60 HZ ACCESSORIES: OVERHEAD SUSPENSION PACKAGE, LIQUID LINE SOLENOID VALVE, LIQUID LINE FILTER DRIER & SIGHT GLASS. (ALL REFRIGERATION ACCESSORIES TO BE BI -FLOW TYPE) UNIT DIMENSIONS: LENGTH 60" X WIDTH 50' X 28' HIGH OPERATING WEIGHT = 385 LBS. CRO ENGINEERING GIROUP INC. 18652 Florida Street, Suite 150 Huntington Deoch, CA 92648 P (00 F 141 -6000 ti 06*.* u u • • r 10:0 • • • • • • u ► r • ••ssr - r�. w w v W•wv W i w w •!• r.f. • • L G RA 5U5111 CORPORATION 5COTT5DALE, AZ City of MlE nll Builk ink Department � » " a �.. s-.W, .« F E I2 -22 -OG V A � Q L E- N REV1510N5 ❑ OG. 15.07 15t LANDLORD 5UDMITTAL ❑ 08.21 .07 15t CITY SUBMITTAL 8 ❑ 02- :07.0 end CITY -5 BMITTAL DATE 5820 5W 73R 5T 50UT1j_M1AM1, EL Rm 10 MECHANICAL - 5CIIEDULE5 � DIAGRAMS