5864 SW 77 TERR_EB-05-054-020 0
CID
co
t_ f 1_ r 1 t 1p l_1/n/ 0 co co
co LID
SEE DETAIL A,-2 A
(F SH-35 E
' -
_ e 1 r r 2'--11 r ! n 21- i1' n i® e dW 17O 2—SH-25 ——_ � I 1
I 20'X3 'xE1a' PLY WD
ACCESS PANEL I I _ _—
AL GLADDDED PANTRY _1
HR FI °r fff \��
I___. __ W/ LIGHT 4 REF f ' ICE,' I
LL DN. CHAIN) 1°I I
-1N I _ a
2° SLOPE BBQ FAMILY
I 1 �
GAOAC E w TERRACE VE E ROOM EA AST j ® j
p('-� �
® ,® `/ [ p ( W 1_
cs) 3'Xa' 6 24' O.G. W/
z IDNNNG
GARAGE NOTES 7° 1 t- 2'XEo° TONGUE g I ' I- I j 1
M% �{'1 (,( PROVIDE S/$' TYPE-X GYP. GROVE CLIG (TYP. �1_1 14 uI I Itu I I FAVER5 CEILING CONE HOUR FIRE TED) AS 1 W ALl� EXT_ GL'S) I � I �I 1 a -PER NO I BELOW° PROVIDE ONE -11- 6'-0 3 W
I COAT VENEER PLASTER OVER C ,5. I U 1
TOP LOW. POINT WALL ® - I 1
EL, 0"® ' (DATUM) THE OPENA LE GA GE DOORS i�- R ` `
WINDOWS MEET THE MIN. REQUIREMENT Z I E
45a THE GARAGE FLOOR AREA GALLERY 1 I -gam s
FOR VENTILATION AS PER F.B.C. �' �+
42' P. ALUM. Ito
PROVIDE SIGN TO AD : 'DANGER. I I > I
DO NOT OPERATE ENGINES WITH DOOR -1 REJECT A�, I 1 t� I 1 I ,
CLOSED CARBON MONOXIDE E ISION -
t
SPHERE CTYP
IS LETHAL ALL RAILING § I �- G I
LOCATIONS) � D/W I SING I as
15 _ »wry WINE/� '�r
i t W e t r 'f 1 ' ! ` W'10 - I 5 6 OR GE (W/1-t m _
L-�} 1 .�
1C, H-35 I6 I KITH 1�1 I 1 I I
t ° Q t V/42"GO - TOPS "o WIOVEN BELOW - r =II(GAS) 1 S$ HIGP -
I _ _®___ 20 Gy C I AINST UP 22 �t 1 °
A® I J o Q O W $ ALL) - GH RAILING
10 ' cn
ABINET ABOVE Q o �° �GAE3INET ABOVE
___ TO REJECT A 4®
t`
OPENING
OOO i- -,
1 _YI t 1 Q p
1 r 1 p
1 V
COVE CL G. ABOVE
I
&=4
I 1 ro to _
1 I
1/$'X FT. SLOPE I I /$'x FT. SL E
f = I I I
f [fff �� ( I `�' awl
I I I I
I I L__ L__� E_ 1 I 6° S° \ � I I I to-3 I 1 tJ1 STUCCO ' LG�ON E„
_ �
I 1 I I I 1 -f
COVERED - LIVING _ 1 I I MTL. LAT OR 1/2
_ I I E _ I z I 10'X10' DEC DE Z _ .' FGtY
j— j---) I TER OE I �c?e�M 1 _ I W I WA. COL. 1 I I PLYWD. § IN
I i I I
171 _ I I 1 I C� I I q I TOP FIN. FL, j CTYpPcc A L xT
L!G V)
CN
® I VX$`I 'S 24' O.G. W/ 12 I I I I '- { I EL. + 0'-0' CDA M) I 1 - 1
� I G� I 2'X ' TONGUE d - - I
W
I GROVE CL'G CTYP.. I E j I I
1 T 2 I ALL EXT. CL'S) itt 1 I T �'
u I I1 I I
-1 _t I ®I `N 1 . 1 r 21,E
,— W W
PEN ING
I ui�T Iri �
42' H. ALUM. I 4` 11`-S�° 4' PAMPER 11''S2® "� 4' °. � °
RAILING TO - -
JECT A j -[ w co
4 SPHERE I 61 j POOL 10 ! -°
(TYP a ALL I I BAT 1-6 CAT. 11, SF_GL. MAC
RAILING SHOWER I--• BEDROOM LO
LOCATIONS) I ( DOOR - j ° E
(WHERE I 0 ENCLOSURE G:U ST 4
ALL SHOW) I -- — BED OOM I I LO
I WASHER
j 1 FAUCET IN
RECESSED I
I
SHOWER I METAL W
_ I_® POCKET Ac,:
ATH 1
I PER F °C.
ita 1 J SH-H 33 4' I a'-10' D1 -2' ' �ts A
CAT, I, SF. GL.
f I LAUN12 Y I , '
ROOM cc
c _ Z`-
1K SH-35 1L H—H-33 1M SH—HI,33 GL.
EGRESS.
11 1_ f
I
W r
TRACK BRACKET OR m
ALL EGRESS WINDOWS TO COMPLY W/ FIG: OUTSIDE
REGULAR ANGLE
TERMITE PROTECTION NOTE WINDOW O DOOR OPERABLE FROM THE INSIDE WITHOUT GARAGE DOOR
. THE USE TOOLS AND PROVIDING A CLEAR OPENING 2' X 6® P.T. W/ 1/4' OUN I D F L 0 0 f R Fo__*OIL 4 N p-, co P.,
AS PER F,B.C. 1$Iro°l.°l, ALL BUILDINGS SHALL HAVE P -CONSTRUCTION TREATMENT NOT LESS THAN LS WIDE X 2VI HIGH AND A SQ. FT, IN . TAPCONS U/ 111/2'
PROTECTION AGAINST SUBTERRANEAN TE 1TES. THE RULES AND LA AS ESTABLISHED PENETRATION e $'
AREA. THE BOTTOM THE OPENING SHALL NOT E MORE Y THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUME SERVICES SHALL BE STAGGERED �" FROM r� � 1 �
THAN 44° OFF THE FLOOR. THE MODE OPERATION MUST 6i,�c1_ : 1/ 1
DEEMED AS APPROVED WITH RESPECT TOPRE-CONSTRUCTION SOIL TREATMENT FOR ---�, FLOG � TOP PLATE a�L � STRUCTURAL PLC �DESCRIPTION
PROTECTION AGAINST SUBTERRANEAN TERMITES. A CERTIFICATE COMPLIANCE NOT REQUIRE THE USE A Y, TOOL, SPECIAL
SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL KNOWLEDGE O EFFORT TO MAKE AVAILABLE THE
COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: REQUIRED CLEAR OPENING, AND NO PART THE �6
'THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION
OPERATION MECHANISM SHALL BE PLACED HIGHER THAN STOP MOULDING �'
SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES 4 LAWS 54 ABO THE FINISHED FLOOR �' < AREA CALCULATION
ESTABLISHED BY THE FLORIDA DEPARTMENT AGRICULTURE AND CONSUME SERVICES.' MIN.35 KSI STEEL TUBS COLUMN(SEE s CT. LOT A : 10,155 . T.
MASONRY P FOR SIZES CONCRETE FILLED W/ ` .�
MIN.2 I CONCRETE ENCL05ED IN r
FIRE RATINGS DESCRIPTION EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT HOUR FIRE RATED PARTITION IC&�4 IS 0
CHILDREN CAN OPEN THE DOOR FROM INSIDE THE OF NC STIBL MATERIALS. COL MUST GROUND L. A/ AREA : 2,2513 . T.
BE
CLOSET° AS PER FBC 1 SET FORTH
N SECT.2 ro THE I HOLES AS
1.- I X FURRING I&' O.C. , ONE LAYER S/$® TYPE X GYPSUM LATH, SCI EVERY BATHROOM DOOR LOCK SHALL E DESIGNED TO ccaL - FIG,1 9_f ra SLY w/ SECTION N EL. A/ AREA s 1,°126 T_
CEMENT-COATED OR RING SPANKED NAILS (o' O.C. PAPS TAPE EMBEDDED N.T. �- 12 -PICx.7 ac a�Ttae� c.�
PERMIT THE PENING THE LOCKED DOOR FROM THE
IN CEMETENTITIOUS COMPOUND O JOINTS, EXPOSED NAIL HEADS COVERED OUTSIDE IN AN EMERGENCY. AS PER FBC I : I /p�
WITH COMPOUND OVER JOINTS, EXPOSED NAIL PEARS COVERED WITH COMPOUND
P FAB TRUSS TOTAL ,�/ t4 : a T.
AND PRODUCT APPROVED INSULATION FI E LASS OR MINERAL WOOL ATTS, S/a' E HOUR
OR BLOWN IN FIBERGLASS,MINERAL WOOL OR CELLULOSIC, INSULATION HAVING NOTE : ALL. HALLWAY DOORS TO BE FIRE D�Y BOARD A 1 ° FT.
A MINIMUM INSULATION VALUE -11. NON-LOG LE (PRIMARY MEANS E5OAPE) 3 16 NAILS �` , T T.
2.- NO. 25 GAUGE CHANNEL-SHAPED STUDS 16' O/C WITH 1 FULL LENGTH LAYERS EA END(TYP.) ,
OF S/$' TYPE 'X' GYPSUM WALLBOARD APPLIED VERTICALLY EACH SIDE, FIRST NT 2 , FT.
LAYER ATTACHED WITH I' LONG NO. ro DRYWALL SCREWS, $' O/C AROUND THE ALL PRECAST ELEMENTS TO BE ATTACHED W/ ,�
PERIMETER AND 12' O/C ON THE INTERMEDIATE STUD_ SECOND LAYER APPLIED 114' DIA_ TAPCONS W/ 1 1/2' PENETRATION INTO �g" r. 1° T
WITH VERTICAL JOINTS OFFSET I STUD-SPACE FROM FIRST LAYER USING AN CONC. 'a ' O.C. EA, WAY, IF PRECAST MEMBER
2X4--114
X4 2X4 a —_ _ -r=1 —_ _ �3
III- d, '- C�I—
APPROVED ADHESIVE, IS LESS THAN O EQUAL TO $' IN WIDTH THAN IX3 SUPPORT —i . / I i 1-1 s c—i i 1 i i i 10 i 1 ul
SOIL STATEMENT STAGGERED D ONLY ONE TOP d BOOT TAPCONS ACCESS IC \ ., • �e i for—�t�t 1—t..�Q� (—t.� m C}
\f`XaI'14IC)�I I @I I'1 k1I�Ikl III It 11 �� ITEMS- 0 a...... dn� sheet Vs
SOIL AT THIS SITE IS SAND 4 ROCK ADEQUATE TO SUPPORT THE DESIGN LOAD PREFAB WD. TRUSS APPLICABLE,
NOTE STRUCTURAL GI.AZQ TRUSSES DOORS ROOFING WINDOWS
OF 2000 P.S.F. I HEREBY ATTEST THAT THE 51TE HAS BEEN OBSERVED AND THE VERIFY ALL WINDOW 4 DOOR T'I' 2 RIDGE VENTILATIOI`CURTAIN WALLS MULLIONS SIGNS GLASS ,WALL
74 - 2
FOUNDATION CONDITIONS A SIMILAR TO THOSE UPON WHICH THE DESIGN IS ROUGH OPENINGS W1TI-1 WINDOW FORECAST SYSTEM$1ANDRAILS RAIO_S FENCES
BASED ON, IF YOU HAVE ANY QUESTION REGARDING THIS MATTER, PLEASE DOOR MANUFACTURER-' N.T, N.T.Q. -
CONTACT THIS OFFICE. STORM SHUTTERSSTEEL JOISTS STORE FRONT AWNINGS
of 5