5864 SW 77 TERR_EB-05-054-017 ----------- ----------
GENERAL NOTES
4' WIDE WOOD ACCE55 GATE WITH SELF-CL05ING 1. CONCRETE SHALL HAVE 3,000 PSI CO-MPRESSIVE STRENGTH AT
DEVICE AND SELF-LATCHING DEVICE TO BE LOCATED to ------ C\2
ON THE POOL SIDE MIN, 3' BELOW TOP OF GATE 28 DAYS, UNLESS OTHERWISE NOTED (LI.O.W.).
'a
TO COMPLY WITH FB.C. (BY OTHERS) 2. ALL REINFORCING STEEL SHALL BE DEFORMED BARS, AND 00 CO
PROf=ERT"r LINE 143,a4' SHALL HAVE A MINIMUM YIELD STRENGTH OF 60,000 PSI GRADE 00 LO
11-01 0 -------- 1-00 60, AND MEET ASTM A-36 SPECS, LO
C\2
E
B_ 71 0
3. ALL STRUCTURAL STEEL SHALL HAVE A MINIMUM YIELD 0 U
STRENGTH OF 36,000 PSI, AND MEET ASTM A-36 SPECS. 0
<
j [a
�7-0 Lill 4� ALL DETAILING, FABRICATION AND PLACING OF REINFORCING E-
j f
BARS MUST FOLLOW THE ACI "MANUAL OF STANDARD PRACTICE
------ --------- FOR DETAILING REINFORCED CONCRETE STRUCTURES", U.O.N.
--------- ----- ----------- -------------- 1 0 0 04
I _;� 5, CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS
V-01 /] FH
251-ol AT JOB SITE BEFORE STARTING WORK. DISCREPANCIES SHALL -
Z :� co
SETBACK ETeACK BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER
I -- ------ BEFORE PROCEEDING WITH THE WORK, Cd
TUM=GP-ASS ESI_Qj�:�
Q R 1)�WA Y
rl 6. STRUCTURAL DRAWINGS SHALL BE WORKED TOGETHER WITH E- 0
Emm�j -4:� C-) 0
4 ARCHI- TECTURAL, A/C, ELECTRICAL AND MECHANICAL DWGS., TO
C'I 4-4
10' V1615ILTY 4' WIDE ACCESS GATE 1,44 _54 LOCATE OPENINGS, DRAINS, SLEEVES, SLOPES, DEPRESSED SLABS,
j 2 4 ClEgEN A BOLTS, CURBS, ETC.
4
TRIANGLE WITH SELF-CL05ING r: 2
DEVICE AND SELF-LATCHI,4G ----------- 7� ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH
DEVICE TO BE LOCATED ACI-301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR
MIN,
ON THE POOL SIDE BUILDINGS"
3' BELOW TOP Or- GATE s, �D
TO COMPLY WITH R5.C, (B* N 8. REMOVAL OF FORMWORK SHALL BE IN ACCORDANCE WITH 4.j
L -----
2
OTHERS)
ACI-347 "RECOMMENDED PRACTICE FOR CONCRETE FORMWORK," -7- 0
10' V151BILTY 9. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ARCHITECT/
TRIANGLE ENGINEER'S APPROVAL.
10. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN.
TUF;�;--CBRASS PLPCr�, 4_4
ON 11. REBARS SHOWN ON SECTIONS ARE FOR PLACEMENT DETAIL
7 Q)
ONLY, SIZE AND AMOUNT OF REBARS ARE AS PER SCHEDULES.
12. CONTRACTOR SHALL OBTAIN LATEST SET OF DRAWINGS, 4j
., 0 0
WALKWAY 1.x INCLUDING ANY REVISIONS, BEFORE STARTING CONSTRUCTION. 0
I I W
It 13. DO NOT SUBSTITUTE MATERIALS, EQUIPMENT, OR METHODS 02
. 0 OF CONSTRUCTION UNLESS SUCH SUBSTITUTIONS OR CHANGES
00
HAVE BEEN APPROVED IN WRITING BY THE OWNER / ARCHITECT
V
4 4 ENGINEER.
_0
12 14. THIS OFFICE DOES NOT ACCEPT ANY RESPONSIBILITY FOR �T4
-IM F-IF-11 EQ9LP CK I I CCI �111
F91 H THE INTERPRETATION OF THESE PLANS BY OTHERS, UNLESS
swimm !2L�c
(PY OT�4EES REQUESTED IN WRITING, AND IT IS GIVEN THE AUTHORITY TO
U U H CHECK AND APPROVE SHOP DRAWINGS, AND TO VERIFY THE
ACTUAL PLACING OF REBARS IN THE FIELD
TION SHALL MEET THE REQUIREMENTS OF
15. ALL CONSTRUC
LOCAL ORDINANCES AND THE "FLORIDA BUILDING CODE",
v� ZZ
CURRENT EDITION.
3 16. WINDOW MANUFACTURER TO VERIFY ALL WINDOW OPENINGS
\C_� 1 10' V1516ILTY AT FIELD PRIOR TO WINDOW PLACEMENT.
e), - cjj% t
tZ TRIANGLE
0
17� NO TIE BEAMS SHALL BE FORMED / POURED PRIOR TO
VO,
TRUSS SHOP DRAWINGS APPROVAL.
117 18. ARCHITECT / INTERIOR DESIGN ENGINEER'S VISITS AT THE
SITE DURING CONSTRUCTION SHALL BE SCHEDULED WITH
CONTRACTOR BEFORE COMMENCING OF WORK AND DURING
L - - ---- .. ....
T27 CONSTRUCTION SHALL BE COORDINATED WITHIN 24 HOURS IN
ADVANCE PRIOR TO INSPECTION.
OR
0
19. THE CONTRACTOR IS FULLY RESPONSIBLE FOR ANY ITEMS
PURCHASED BY THE OWNER AND GIVEN TO THE CONTRACTOR
Ca W FOR INSTALLATION.
17 - 4 , 0
"k
ILL! 20. THE CONTRACTOR SHALL NOT PROCEED WITH ANY
A. TIONAL TIFICATION
'7 ADDI
Pi SERVICES OR WORK WITHOUT PRIOR NO
TO THE OWNER FOLLOWED BY A CHANGE ORDER,
0 Cn
0
21. THE CONTRACTOR SHALL MAKE REQUIRED ARRANGEMENTS, F14
f=R0f=EFTY LINE 143.&4' SECURE AND PAY FOR ALL SANITARY FACILITIES, BARRICADES,
4' WIDE WOOD ACCESS, GATE WITH 5ELF-CL05ING G) ENCLOSURES, AND FENCING AS NEEDED FOR AND DURING THE 1-4
DEVICE AND SELF-LATCHING DEVICE TO BE LOCATED PROGRESS OF CONSTRUCTION. CONTRACTOR SHALL PROTECT _Rt
ON THE FOOL SIDE MIN, 3' BELOW TOP OF GATE ADJACENT PROPERTIES. 0
TO COMPLY WITH F.B.C. (BY OTHERS) SCALE 1/0' 1'-0' N 22. THE ARCHITECT / INTERIOR DESIGNER / OWNER HAS THE 01
RIGHT TO REFUSE ANY MATERIAL AND WORKMANSHIP THAT DOES 0
NOT MEET HIGH QUALITY STANDARDS OF THE VARIOUS TRADES 1�4
INVOLVED. 12L.,
23. THE CONTRACTOR SHALL MAINTAIN AN ACCURATE RECORD
SOIL STATEMENT SECURITY AND FORCED ENTRY PREVENTION OF CHANGE ORDERS AND VARIATIONS THROUGHOUT THE LO
4' OF MULCH TO PROGRESS OF THE WORK. USE ONE SET OF DOCUMENTS
EXTEND OVER BERM LANDSCAPE LEGEND SOIL AT THIS SITE IS SAND & ROCK ADEQUATE TO SUPPORT THE 1. PROVIDE INTRUSION AND BURGLARY SECURITY DEVICES AS SET FORTH EXCLUSIVELY FOR THIS JOB.
�/ 4' HIGH EARTH BERM IN THE FLORIDA BUILDING CODE. cj E-'
TO ENCIRCLE SHRUB Chapter 18A-Ordinance 98-13 DESIGN LOAD OF 2000 PSF. AFTER EXCAVATION SIGNED AND 24. THE CONTRACTOR SHALL DELIVER THE ANNOTATED JOB
_12"MIN� SEALED LETTER WILL BE SUBMITTED BY THE ARCHITECT OR THE 2. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A RECORD SET TO THE OWNER UPON COMPLETION OF THE WORK Z �D
ZONE R5_3 ENGINEER ATTESTING THAT THE SITE HAS BEEN OBSERVED AND FORCE OF 300 LB. APPLIED IN ANY MOVEABLE DIRECTION AND IN AS A CONDITION OF ACCEPTANCE.
REMOVE ALL BURLAP AND TWINE DISRTICT THE FOUNDATION CONDITIONS ARE SIMILAR TO THOSE UPON WHICH ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH IN THE FLORIDA 25. CLEANING AND DEBRIS REMOVAL. THE OWNER SHALL RECIEVE
FROM TOP OF ROOT BALL -<--SUBSOIL TO BE LOOSENED WITH THE DESIGN IS BASED ON. BUILDING CODE. THE PROPERTY FREE FROM DUST, ALL GLASS SURFACES SHALL
SYNTHETIC BURLAP AND/OR A PICK PRIOR TO PLANTING Gross Land 14,162 (acre) Net Lcind�0,78B (acre) Water Bodies-(acre)
TWINE TO BE REMOVED 3. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY BE CLEAN AND DEBRIS SHALL BE REMOVED FROM THE SITE. THE
ENTIRELY LEGAL DESCRIPTION OPERATED FROM, THE EXTERIOR WITH A MINIMUM OF 6000 POSSIBLE KEY CONTRACTOR SHALL MAKE EFFORT TO MAINTAIN THE FLOOR
BACKIFILL WITH TOPSOIL AND PEATMOSS IN REQ. PROV� 04 Q4 C-0
A 3:1 RATIO BY VOLUME. Landscape Open Space (if applicable) % % LOT 6 BLOCK 142, CORAL GABLES RIVIERA SECTION PART NINE CHANGES OR LOCKING AUXILLIARY SINGLE DEAD BOLT WITH HARDENED 13OLT CLEAN DURING CONSTRUCTION PROGRESS. LEFTOVERS FORM 1:4
BACKFILL IN 9" LAYERS, WATERING EACH SUBDIVISION, ACCORDING TO THE PLAT THEREOF AS RECORDED IN INSERTS, MEALS CONSUMED ON PREMISES SHALL BE DEPOSITED IN SEALED n
LAYER UNTIL SETTLED. DO NOT TAMP. CONTAINERS. - co r_0
Greenbelt Width (if applicable) feet feet PLAT BOOK 55, AT PAGE 84 OF THE PUBLIC RECORDS OF DADE 4. THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL HAVE 0
COUNTY, FLORIDA. SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING DOORS. THE 26. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND 04
SHRUB DETAIL (00 E-1
%
Lawn Area (as defined in Ordinance) % INACTIVE LEAF SHALL HAVE MULTIPLE POINTS OF LOCKS WITH 5/8" MIN. METHODS OF CONSTRUCTION, AND FOR THE SEQUENCES AND C0 co -It
ro,4-12 SQ FT THROW BOLTS WITH INSERTS. PROCEDURES TO BE USED,
TREES ZONING C,4LCUL,4TIONS; 5� JAMBS OF ALL EXTERIOR OFFSET TYPE IN SWING DOORS SHALL BE
Trees per Net Lot(Note: 30% of required trees 27. FOR BURGLARY INTRUSION NOTES REFER TO "METROPOLITAN
and/or palms shall 3 PER NET LOT RABBETTTED OR OF SIMILAR FABRICATION TO PREVENT DEFEATING THE DADE COUNTY CODE", SECTION 8C/18. Lij
be native species. No more than 20% of the' native tree LOT AREA : 10,71aO SQ. FT. PURPOSE OF THE STRIKE AND THE INTEGRITY OF THE LOCKS AND LATCHES. �.4 $___4 U) 0
28. THE ARCHITECTURAL AND STRUCTURAL DRAWINGS SHALL o T-) --4' CO
Z
requirement shall be Sobal Palmetto [cabbage palm]) 6. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NON GOVERN THE LOCATIONS OF THE INSTALLATIONS OF THE Z Z
Street Trees ro PER NET LOT GROUND FL. A/C AREA 2,2E�O SQ. FT, REMOVEABLE PINS AND NON-EXPOSED SCREWS, MECHANICAL AND ELECTRICAL SYSTEM. CONTRACTOR MUST INFORM 0
(Trees int the right of way (*) or on private property)* will SECOND FL. A/C AREA 1,12(o SQ- FT. 7. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN THE ARCHITECT BEFORE FORMING ANY CONCRETE BEAM IF P. co 12.
require Public Works approval or Special Taxing District. NATIONAL STANDARDS ISTITUTE'S STANDARD 297.1. INTERFERING WITH A/C DUCT OR PLUMBING FIXTURES EXACT
TOTAL A/C, AREA 3,c3a4 50, FT, LOCATION. ANY DEVIATION FROM THE MECHANICAL / ELECTRICAL
TOTAL NUMBERS OF TREES 9 PER NET LOT 8, VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40 OF PLANS TO ACCOMODATE THE ABOVE CONDITIONS SHALL BE MADE
THE INSIDE LOCKING ACTIVATING DEVICE OF LOOSE AND SWING DOORS SHALL WITHOUT ADDITIONAL COST TO THE OWNER.
Shrubs (10 shrubs for each tree required) CjxIO 'BO SHRUBS GARAGE AREA 451 SQ. FT. COMPLY WITH THE AMERICAN NATIONAL STANDARD INSTITUTE'S STANDARD 29. THE CONTRACTOR SHALL PRODUCE, BY MEANS OF SHOP
*30% shrubs'/hedqes shall be native species. COVERED TERRACE 335 SQ. FT. 297A. DRAWINGS, ALL ADDITIONAL DETAILS WHICH ARE INFERABLE FROM
*Irrigation system required pursuant to COVERED VERANDA 130 SQ. FT. 9. WINDOWS SHALL BE INSTALLED AND CONSTRUCTED SO THAT NO PANEL THESE PLANS AND WHICH ARE NECESSARY FOR THE EXECUTION
Chapter 33 Dade County Code AND COMPLETION OF THE WORK.
ENTR'r 62 SQ. FT, CAN BE LIFTED FROM THE TRACKS WHEN IN THE LOCKED POSITION AND SO 0
Business (BU) and Industrial (IU) zones 5ALCON'T' - roro SQ. FT. AS TO COMPLY WITH THE ARCHITECTURAL ALUMINUM MAGS ASSOCIATION 30� THE CONTRACTOR MUST FURNISH ALL LABOR, TOOLS,
STANDARDS FOR FORCE ENTRY RESISTANCE, AAMA 13033 PROVIDE LOCKS. MATERIALS AND EQUIPMENT NECESSARY TO EXECUTE THE
DOUBI F STRAND OF 10 GAUGE A). Open space required per Section 33 of Zoning Code EXTERIOR WINDOW SHALL BE LOCKED WITH DEVICE CAPABLE OF CONSTRUCTION OF THIS JOB.
GALV. WIRE TWISTED (THREE MAX. BLDG. COVERAGE : 3,23ro SQ. FT, (309. MAX) WITHSTANDING A FORCE OF 150 LB. APPLIED IN AN OPERABLE DIRECTION. 0
GUYS PER TREE, SPREAD net lot area (sq.ft.) - x - %= sq.ft. 31. UPON ACCEPTANCE AS SUBSTANTIALLY COMPLETE, THE �-4
120 DEGREES APART) GARDEN HOSE B). P(jrking lot landscaping required per Chapter 18A-6(J) 5LDG;. COVERAGE f='ROVIDED : 3,23(o SQ. FT. 10. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR ARCHITECT SHALL ISSUE THE CONTRACTOR A "PUNCHLIST",
WHITE FLAGGING TAPE 4' OF MULCH TO number of parking spaces= - x 10 sq�ft.= sq.ft. SCOPE OR VISION PANELS. INDICATING THE OBSERVED DEFICIENCIES IN THE WORK. THE
EXTEND OVER BERM C . Add A+B= - sq.ft, (total lawn area required) CONTRACTOR SHALL MAKE SUCH CORRECTIONS AND ACHIEVE
4" HIGH EARTH BERM D�. Maximum lawn area (sod) permitted 20% of A+B= sq,ft. MAX. IMFERVIOU5 AREA : 4,314 5Q- FT- (409.' MAX) FINAL COMPLETION WITHIN 14 CALENDAR WORKING DAYS.
TO ENCIRCLE TREE _ x .20= -sqft. DOOR NOTES: 0�
E). Maximum lawn area provided - sq.ft. IMPERVIOUS COVERAGE PROVIDED 4,215 SQ. FT. COMPONENTS OF MEANS OF ESCAPE 32. CONTRACTOR TO VERIFY THAT THERE ARE NO PERTINENT .4
FEATURES ON THE ADJACENT PROPERTIES AND ACROSS THE
12"MIN� A. NO DOOR IN THE PATH OF MEANS OF ESCAPE SHALL BE LESS
STREET THAT MAY AFFECT THE ONSITE SEWAGE TREATMENT AND
THAN 28" WIDE EXCEPT THAT BATHROOM DOORS MAY BE 24" WIDE DISPOSAL SYSTEM INSTALLATION. C14
Tree Name Native Max. Canopy Height UNLESS A LAGER DOOR OPENING IS REQUIRED TO SATISFY I'd
Species Height Diameter at Time REQUIREMENTS OF THE FLORIDA BUILDING CODE. Q)
21X2-X3'-O- STAKE, -<-SUBSOIL TO BE LOOSENED WITH Symbol New Scientific - C-ommon Yes/No of LOCATION RECUIREL:) PROVIDEE> -"4 0
NOTCHED TO RETAIN GUY A PICK PRIOR TO PLANTING Planting B. EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN Q)
OPEN THE DOOR FROM INSIDE THE CLOSET. 0
(2UF-RCUS LIVE FRONT 25'-0' 20'-0' 4-) (,j Q) 0
VIRSINIANA OAK YES 501-01 14'-C. C. EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO ALLOW THE ;.q 4 ;.-,
I 1 -11-(, 11
0
15T FLOOR 51DE 0
PO CALLICARFA 4MEPICAN YES 4'-5. Ia. OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY.
REMOVE ALL BURLAP AND TWINE AMERICANA jI5EAUTT-5EFRY I I I .11-r 11 CALL 48 HOURS
FROM TOP OF ROOT BALL, IST FLOOR SIDE III-V D. DOORS MAY BE SWINGING OR SLIDING. BEFORE YOU DIG
SYNTHETIC BURLAP AND/OR BACKFILL WITH TOPSOIL AND PEATMOSS IN *Shrubs to screen A/C units & pool equipment to be planted at Ht. of 36" IF71-011 sheet no.
TWINE TO BE REMOVED A 3:1 RA110 BY VOLUME. **Tr I ht >f-way shall be free of obstruction between the height of 2ND FLOOR 51DE IE5'-0- E. NO DOOR IN ANY MEANS OF ESCAPE SHALL BE LOCKED AGAINST
ENTIRELY BACKFILL IN 9- LAYERS, WATERING EACH (,ees in ria -c I
LAYER UNTIL SETTLED. DO NOT TAMP, and (6y feet. EGRESS WHEN THE BUILDING IS OCCUPIED. ALL LOCKING DEVICES WHICH IT S THE LAW!
2ND FLOOR 51DE 15'-0 24'-10' IMPEDE OR PROHIBIT EGRESS OR WHICH CANNOT BE EASILY DISENGAGED 1-800-432-4770
SHALL BE PROHIBITED.
SHADE TREE DETAIL SUNSHINE STATE ONE CALL OF FLORIDA, INC.
MAXIMUM HEIGHT ALLOWED 25' TO MEDIAN OF ROOF
0 of
0
�_-__ z