06-765-016
LUMINAIRE SCHEDULE LUMINOUS INTENSITIES BASED ON THE USE OF SYLVANIA LAMPS DES MTS LAME VOLTS No. OF LAMPS DESCRIPTION MANUFACTURER CATALOG No. MANUFACTURER CATALOG No. REMARKS A R F 120 1 -60 A -19 60 W SINGLE LAMP INCANDESCENT DELUX 2303 BSS BUILDING STRUCTURAL STEEL C B R F 120 1 -75 PAR30NFL TRACK HEAD LOL 9630BK/60028K CIRCUIT BREAKER CLG CEILING C R F 120 DC DOWN CAN LOL 1102P1/1176 EC EMPTY CONDUIT EG D R F 120 1 -90 PAR38HFL 6" BLACK CYLINDER DELUX 2787 ELECTRIC WATER COOLER EM ELECTRIC WATER HEATER E R F 120 TV PENDANT LIGHT LBL PF5495BUSC3515 UG UNDERGROUND UL E1 R F 120 VOLT AMPERES PENDANT LIGHT LBL PF5495AMSC3515 WARM WHITE WP WEATHERPROOF F W F 120 WALL SCONCE LATIGO SY0715 G R F 120 3- FO32 /830/XP/EC0 2X4 3 -LAMP RECESSED FLUORESCENT LOL XP2GVA332UNVCI G1 R F 120 3 -FO32 /830 /XP/ECO 2X4 PARABOLIC RECESSED FLUORESCENT LOL DPAG18LS332120SO H R F 120 3- FO17 /830/XP/ECO 2X2 RECESSED FLOURESCENT TROFFER LOL XT2GV126UUNVSO J R MH 120 1- MCP100 /C/U/MED HID DOWN LIGHT LOL C7E170VM/MG /C710MH0E1 S LED 120 INCL EXIT LIGHT DLT WIRED AHEAD OF LOCAL SWITCH S 1 120 INCL EMERGENCY LIGHT HARDI WIRED AHEAD OF LOCAL SWITCH 1. 2. 3. 4. 5. 6 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. ELECTRICAL GENERAL NOTES IT SHALL BE UNDERSTOOD THAT ALL WORK PERFORMED SHALL BE DONE BY A LICENSED ELECTRICAL CONTRACTOR AND IN A FIRST CLASS WORKMANLIKE MANNER. SAID CONTRACTOR SHALL MEET ALL REQUIREMENTS SET FORTH BY ANY LOCAL ORDINANCE AND /OR GOVERNING AUTHORITIES. ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE. LATEST EDITION NEC AND THE LATEST EDITIONS OF ALL LOCAL CODES, RULES, AND ORDINANCES HAVING JURISDICTION. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS, AND SUPERVISION NECESSARY TO ACCOMPLISH THE WORK SHOWN AND /OR NOTED ON THE DRAWINGS. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BID AND VERIFY ALL CONDITIONS, LOCATIONS, DIMENSIONS AND COUNTS AS SHOWN AND /OR NOTED ON THE DRAWINGS. THIS SHALL INCLUDE ANY AND ALL FABRICATIONS REQUIRED PRIOR TO INSTALLATION. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR FOR THE ADVANCED ORDERING OF LONG LEAD ITEMS SO AS NOT TO INTERFERE WITH THE PRODUCTION OF OTHER TRADES RESULTING IN ANY DOWN OR LAG TIME. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN (1) YEAR FROM DATE OF ACCEPTANCE, UNLESS INDICATED OR SPECIFIED OTHERWISE. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR TO ORIGINAL CONDITIONS ANY AND ALL DAMAGES TO BUILDING SURFACES, EQUIPMENT AND FURNISHINGS CAUSED DURING PERFORMANCE OF WORK. ELECTRICAL CONTRACTOR SHALL NOT SCALE DRAWINGS. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT UNLESS NOTED OTHERWISE. ALL ELECTRICAL EQUIPMENT, DEVICES, WIRE, ETC., SHALL BE LISTED FOR THE INTENDED USE, WITH UNDERWRITER'S LABORATORIES, INC. (UL) WHERE STANDARDS HAVE BEEN ESTABLISHED BY UL AS A MINIMUM, ALL EQUIPMENT SHALL MEET APPLICABLE STANDARDS FOR THE TYPE OF EQUIPMENT AND INTENDED USE OF THE FOLLOWING: A. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). B. ILLUMINATING ENGINEERS SOCIETY (IES). C. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM). D. NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA). NOTE: THESE STANDARDS ARE SUBORDINATE TO CODES AND STANDARDS SET BY UL IT SHALL NOT BE THE INTENT OF THESE PLANS AND /OR SPECIFICATIONS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE ELECTRICAL CONTRACTOR SHALL BE EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. ALL CONDUIT RUNS ARE SHOWN DIAGRAMMATICALLY. EXACT ROUTING SHALL BE DETERMINED IN THE FIELD, UNLESS OTHERWISE NOTED. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL THE PROPER NUMBER OF CONDUCTORS IN ALL RACEWAYS AS REQUIRED TO ACCOMPLISH THE PROPER FUNCTIONING OF THE DEVICE OR EQUIPMENT AS SHOWN. A. THE ELECTRICAL CONTRACTOR SHALL PROVIDE & INSTALL 4-3/4" E.C. FROM ALL FLUSH MOUNTED, PANELBOARDS TERMINATING 6" ABOVE CEILING. THE ELECTRICAL CONTRACTOR SHALL KEEP ALL AREAS IN WHICH WORK IS BEING PER- FORMED, FREE FROM DEBRIS AT ALL TIMES AND SAID AREAS SHALL BE LEFT BROOM CLEAN AT THE END OF EACH WORKING DAY. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES. INSPECTIONS, AND TESTING. ARCHITECTURAL AND /OR ENGINEERING EXPENSES THAT ARE INCURRED DUE TO REVISIONS OR SUBSTITUTIONS REQUESTED BY THE CONTRACTOR SHALL BE PAID FOR BY THAT CONTRACTOR. ELECTRICAL CONTRACTOR SHALL SUBMIT (6) COPIES OF EQUIPMENT LAYOUT FOR ALL ELECTRICAL SPACES, ROOMS, ETC. TO ENGINEER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT OR INSTALLING CONDUITS, ETC. LAYOUT SHALL CONSIST OF PLAN VIEWS ( SCALED AT 1/2" = 1' -0" ) AND ELEVATIONS (DIMENSIONED) FOR EACH SUCH SPACE, ROOM, ETC. ELECTRICAL CONTRACTOR SHALL SUBMIT AT ONE TIME, SIX (6) SETS OF LOOSE -LEAF BOUND BOOKS, INDEXED WITH ALL PRODUCTS, MATERIALS, LIGHTING FIXTURES, LAMPS, WIRING DEVICES, SWITCHGEAR, ETC. ALL EQUIPMENT SHALL BE AS SPECIFIED ON PLANS. THE RESPONSIBLITY TO ACCEPT OR REJECT ANY PROPOSED SUBSTITUTION REMAINS WITH THE PROJECT ENGINEER. THE CONTRACTOR MAY AT HIS JUDGMENT USE ANY ARTICLE, DEVICE, PRODUCT, OR MATERIAL WHICH IN THE JUDGMENT OF THE ENGINEER EXPRESSED IN WRITING ARE EQUAL TO THAT SPECIFIED. UNLESS NOTED AS EXISTING, ALL EQUIPMENT, WIRING, DEVICES, ETC., SHALL BE NEW AND AS SPECIFIED. COORDINATE ALL ELECTRICAL SITE WORK WITH GENERAL CONTRACTOR PRIOR TO INSTALLATION. FOR ELECTRIC POWER SYSTEM. A. COORDINATE POWER SERVICE WITH POWER COMPANY. B. VERIFY LOCATION OF POWER SERVICE TERMINATION WITH POWER COMPANY PRIOR TO SUBMITTING BID. FOR TELEPHONE SYSTEM: A. PROVIDE GROUNDING FOR ALL TELEPHONE/DATA OUTLETS AND EQUIPMENT PER REQUIREMENTS OF OWNERS TELEPHONE COMPANY. B. VERIFY LOCATION OF TELEPHONE SERVICE WITH TELEPHONE COMPANY, PRIOR TO SUBMITTING BID. 23. ALL CONDUCTORS SHALL BE IN CONDUIT. ALL CONDUITS SHALL BE INTERMEDIATED (IMC) OR RIGID GALVANIZED STEEL (RGS) EXCEPT THAT. (a) POLYVINYL CHLORIDE (PVC) CONDUITS MAY BE USED IN CONCRETE SLABS, WALLS, AND UNDERGROUND PROVIDED ELBOWS AND RISERS ARE RGS: (b) ELECTRICAL METALLIC TUBING (EMT) MAY BE USED IN OR ON WALLS OR CEILING WHERE NOT SUBJECT TO MECHANICAL DAMAGE, DAMP CONDITIONS OR CORROSIVE CONDITIONS; (c) LIQUID -TIGHT FLEXIBLE CONDUIT WHERE REQUIRED; (d) FLEXIBLE METALLIC CONDUIT WHERE REQUIRED IN DRY LOCATIONS; (e) THE USE OF AC, MC, OR NM CABLES SHALL BE PROHIBITED. ALL CONDUITS IN HAZARDOUS AREAS (PER NEC) SHALL MEET THE REQUIREMENTS OF NEC CHAPTER 5. ALL FITTINGS FOR EMT SHALL BE MADE OF STEEL 24. FOR UNDERGROUND ELECTRICAL CONDUITS, PROVIDE PULL BOXES, SUCH THAT NO SINGLE CONDUIT RUN HAS BENDS IN EXCESS OF 360. PULL BOXES SHALL BE SUITABLE AND APPROVED FOR THE INTENDED USE. WHERE CONDUITS PASS UNDERNEATH PAVED AREAS THEY SHALL BE RGS. WHERE UNDERGROUND CONDUITS ARE NOT EXPOSED TO MECHANICAL DAMAGE OR ARE NOT UNDER PAVED AREAS, THEY MAY BE SCHEDULE 40 PVC, BUT ALL CONDUIT RISERS SHALL BE RGS. RGS CONDUITS SHALL EXTEND A MINIMUM OF 18" BELOW GRADE 25. APPLY BITUMASTIC COATING TO ALL METALLIC CONDUITS IN SLABS OR UNDERGROUND. 26. ALL CONDUCTORS SHALL BE COPPER, RATED 75'c WET/DRY EXCEPT WHERE OTHERWISE REQUIRED BY U.L OR CODES (LION). MINIMUM WIRE SIZE SHALL BE #12 AWG EXCLUDING CONTROL WIRING. PROVIDE INSULATED EQUIPMENT GROUNDING CONDUCTOR IN EACH CONDUIT. 27. WIRE WAYS SHALL BE SIZED AS REQUIRED, PER NEC, UNLESS OTHERWISE NOTED. 28. ALL ELECTRICAL EQUIPMENT SHALL BE RAINTIGHT WHERE EXPOSED TO THE WEATHER. ALL FLEX CONDUITS CONNECTED TO SUCH EQUIPMENT SHALL BE LIQUID - TIGHT. 29. OUTLET BOXES SHALL BE STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURE FOR OTHER CLASSIFIED AREAS. PROPER PLASTER RINGS SHALL BE USED WITH OUTLET BOXES. PROPER COORDINATION BETWEEN ELECTRICAL SUBCONTRACTOR AND GENERAL CONTRACTOR FOR PLASTER RING INITIATION WILL BE REQUIRED. NO "GOOF" RINGS SHALL BE ALLOWED. ALL OUTLET BOXES SHALL BE SECURELY FASTENED. ALL DEVICES SHALL BE WHITE (DECORA TYPE) WITH STAINLESS STEEL PLATES (UON). 30. MOTOR STARTERS SHALL BE MANUAL OR MAGNETIC, AS INDICATED OR REQUIRED, WITH OVERLOAD RELAYS OR FUSES IN EACH HOT LEG. 31. FURNISH AND INSTALL DISCONNECT SWITCHES AND WIRING FOR AIR CONDITIONING SYSTEM AS PER MANUFACTURER RECOMMENDATIONS. CONTROLS ARE TO BE SUPPLIED BY AIR CONDITIONING CONTRACTOR AND CONNECTED BY ELECTRICAL CONTRACTOR. PROVIDE ALL CONTROL WIRING FOR A/C SENSORING AND CONTROL UNITS. COORDINATE WITH A/C CONTRACTOR FOR WIRING DIAGRAMS AND EXACT MOUNTING LOCATIONS. 32. ALL DISCONNECT SWITCHES SHALL BE SIZED BY NEC TO ACCOMMODATE EQUIPMENT SERVED, INCLUDING REQUIRED FUSES, U.O.N., DISCONNECT SWITCHES SHALL BE HORSEPOWER RATED. HEAVY -DUTY TYPE. 33. ALL FUSES SHALL BE CURRENT LIMITING, PER U.L. RATED 600 VOLTS, UNLESS OTHERWISE NOTED. A. NONTIME DELAY FUSES IN MAIN SWITCHES AND SWITCHES FEEDING PANELS. B. TIME DELAY FUSES FOR MOTOR AND A/C CIRCUITS. 34. ELECTRICAL CONTRACTOR SHALL VERIFY CIRCUIT PROTECTIVE DEVICE RATING FOR EQUIPMENT PRIOR TO CONSTRUCTION. 35. TWO AND THREE -POLE CIRCUIT BREAKERS SHALL HAVE COMMON TRIP. NO TIE HANDLES SHALL BE PERMITTED. ALL PANELBOARDS SHALL HAVE COPPER BUS. ALL CIRCUIT BREAKERS SHALL BE INVERSE TIME -TYPE (THERMAL - MAGNETIC). 36. WHERE CORE DRILLING OF FLOOR /WALLS IS REQUIRED, CONTRACTOR SHALL SEAL OPENINGS WATERTIGHT AFTER UTILITIES HAVE BEEN INSTALLED. LOCATION OF CORED HOLES SHALL BE COORDINATED WITH LOCATION OF EQUIPMENT IN A MANNER TO BE CLEAN AND FUNCTIONAL THE CONTRACTOR SHALL INSTALL ONLY ONE CONDUIT PER HOLE AND SEAL THE OPENING AROUND THE CONDUIT AS SPECIFIED. 37. PROVIDE FIRE RETARDANT U.L APPROVED SEALANT ON ALL PENETRATIONS OF FIRE RATED PARTITIONS, WALLS AND STRUCTURAL SLABS. IT SHALL BE THE RESPON- SIBILITY OF THE ELECTRICAL CONTRACTOR TO VERIFY, PRIOR TO SUBMITTING BID, LOCATIONS OF ALL SUCH FIRE RATED PARTITIONS, WALLS, AND STRUCTURAL SLABS. 38. ALL OPENINGS FOR LIGHT FIXTURES IN CEILING SHALL BE PROTECTED IN A MANNER INGR (THIS APP CODES) THAT WILL PROVIDE HE SAME RATING AS THE CEIL- ING. TO ALL FIRERATED CEILINGS). ALL FLUORESCENT BALLASTS SHALL BE ELECTRONIC I.S. AND HAVE P. F. OF 0.90. ALL BALLASTS FOR MERCURY VAPOR, METAL HALIDE AND HIGH PRESSURE SODIUM FIXTURES SHALL BE CONSTANT WATTAGE TYPE WITH 5% LAMP WATTS FOR 10X NOMINAL LINE VOLTAGE VARIATION. 40. PROVIDE LAMPS WITH FIXTURES, SEE LUMINAIRE SCHEDULE FOR LAMP TYPE. 41. ALL CONNECTIONS TO GROUND RODS & BUILDING STEEL SHALL BE MADE WITH UL APPROVED WELDED CONNECTIONS, UNLESS OTHERWISE NOTED. 42. PROVIDE MOUNTING BACKBOARDS FOR ELECTRICAL AND COMMUNICATION EQUIPMENT. BACKBOARDS SHALL BE OF TYPE "AC" PLYWOOD, PAINTED ON BOTH SIDES AND EDGES WITH TWO COATS OF LIGHT GREY PAINT. 43. PROVIDE A FUSE HOLDER AND FUSE IN THE PRIMARY SIDE OF EACH UNGROUNDED CONDUCTOR FOR EACH BALLAST (BUSSMAN HEB AND FNQ OR EQUAL), AT THE HAND HOLE OF EACH EXTERIOR POLE MOUNTED LIGHTING FIXTURE OR J -BOX FOR WALL OR GROUND MOUNTED FIXTURE. 44. PROVIDE TEMPORARY ELECTRICAL SERVICE FOR USE BY ALL TRADES DURING CON- STRUCTION AND REMOVE SAME AT COMPLETION OF PROJECT, 45. THE ELECTRICAL CONTRACTOR SHALL FURNISH A COMPLETE SET OF AS -BUILT DRAWINGS, SHOWING ALL CHANGES AND DEVIATIONS TO THE ARCHITECT/ENGINEER PRIOR TO COMPLETION OF THE PROJECT. 46. PREPARE AND AFFIX A TYPEWRITTEN DIRECTORY TO THE INSIDE COVER OF EACH NEW AND OR EXISTING (REVISED) PANELBOARD INDICATING LOADS CONTROLLED BY EACH CIRCUIT. AMP AMPERES AFF ABOVE FINISHED FLOOR AG ABOVE GRADE ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE AC ALTERNATING CURRENT AHU AIR HANDLING UNIT A/S ANTI -SWEAT AIC AMP INTERRUPTING CAPACITY BLDG BUILDING BSS BUILDING STRUCTURAL STEEL C CONDUIT CCT CIRCUIT CT CURRENT TRANSFORMER CU COPPER CB CIRCUIT BREAKER CLG CEILING CW COOL WHITE CWP COLD WATER PIPE DC DIRECT CURRENT E EXISTING EC EMPTY CONDUIT EG ELECTRICAL GROUND EM EMERGENCY ER EXISTING TO BE REMOVED ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLER EM ELECTRIC WATER HEATER EP EXPLOSION PROOF EX. EXISTING F FLUORESCENT FA FIRE ALARM FLR FLOOR FC FOOT CANDLE FPL FLORIDA POWER & LIGHT FT FOOT GALV GALVANIZE GFI GROUND FAULTINTERRUPTER GND GROUND HT HEIGHT HID HIGH INTENSITY DISCHARGE HIPS HIGH PRESSURE SODIUM HO HIGH OUTPUT I INCANDESCENT ISC INSTANTANEOUS SHORT CIRCUIT ID IDENTIFICATION JB JUNCTION BOX KW KILOWATT KVA KILO VOLT- AMPERE LIPS LOW PRESSURE SODIUM LT LIGHT MFG MANUFACTURER MTG MOUNTING MID MOUNTED MT MOUNT MV MERCURY VAPOR MH METAL HALIDE NIC NOT IN CONTRACT NC NORMALLY CLOSED NO NORMALLY OPEN P PENDANT PA PUBLIC ADDRESS PEC PHOTOELECTRIC CELL PF POWER FACTOR PNL PANEL R RECESSED REP REPRESENTATIVE RGS RIGID GALV. STEEL RS RAPID START S SURFACE Sc SHORT CIRCUIT "SUBJECT FIELD INSPEC TV TELEVISION TX TRANSFORMER UG UNDERGROUND UL UNDERWRITERS LABORATORIES UON UNLESS OTHERWISE NOTED VA VOLT AMPERES W WATT WW WARM WHITE WP WEATHERPROOF GENERAL CONDITIONS: 1. THE NATURE OF THIS CONTRACT INVOLVES EXTENSIVE REMODELING OF EXISTING FACILITIES. THE ELECTRICAL CONTRACTOR, PRIOR TO BID, SHALL INSPECT THE EXISTING CONDITIONS AT THE JOB SITE AND ACQUAINT HIMSELF WITH THE CONDITIONS THAT WILL AFFECT HIS WORK. 2. PRIOR TO ROUGH -IN, THIS CONTRACTOR SHALL COORDINATE HIS WORK WITH THE ACTUAL EQUIPMENT BEING FURNISHED. 3. PRESENT ELECTRICAL EQUIPMENT WHERE INDICATED ON THE DRAWINGS OR WHERE THE INSTALLATIONS WILL INTERFERE WITH THE INSTALLATION OF NEW EQUIPMENT OR NEW ARCHITECTURAL CHANGES, SHALL BE REMOVED, RELOCATED, OR RE -ROUTED TO PERMIT COMPLETETION OF SUCH WORK. 4. SALVAGED MATERIALS, EQUIPMENT, AND LIGHT FIXTURES SHALL BE DELIVERED TO THE OWNER AT HIS PROPERTY AND STORED WITHIN THE BUILDING WHERE DIRECTED. ANY REMOVED MATERIALS OR EQUIPMENT WHICH THE OWNER DOES NOT WISH TO KEEP SHALL BE DISPOSED OF BY THE CONTRACTOR, WITHOUT ADDITIONAL COST TO THE OWNER. 5. ALL PRESENT CONDUIT IN EXISTING AREAS TO BE ALTERED, WHICH WILL HAVE NO USE UPON COMPLETION OF THE ALTERATIONS SHALL BE REMOVED. WHENEVER CONDUITS ARE OR WILL BECOME EXPOSED TO VIEW, OR WILL INTERFERE WITH THE INSTALLATION AND COMPLETION OF THE WORK REQUIRED.THEY SHALL ALSO BE REMOVED. 6. THE ELECTRICAL CONTRACTOR SHALL DETERMINE THE EXTENT TO WHICH EXISTING CONDUIT AND THE WIRING WILL HAVE TO BE RE- ROUTE), RELOCATED, OR RECONNECTED, AND THE AMOUNT OF ADDITIONAL WORK WHICH MAY BE REQUIRED DUE TO THE PHYSICAL CONDITIONS OF THE CONDUIT AND WIRING SHALL BE PERFORMED UNDER THIS CONTRACT WITHOUT ADDITIONAL CHARGES TO THE OWNER. 7. CONDUIT SHALL NOT BE RUN EXPOSED THROUGH EXISTING OR NEW FINISHED SPACE UNLESS WRITTEN PERMISSION IS GRANTED BY THE OWNER. 8. INTERRUPTION OF EXISTING FACILITIES OR SERVICES SHALL BE KEPT TO A MINIMUM AND THE CONTRACTOR SHALL FURNISH ALL MATERIALS AND LABOR REQUIRED WHENEVER TEMPORARY CONDITIONS ARE NECESSARY TO MAINTAIN CONTINUITY OF SERVICE. INTERRUPTION OF SERVICES, THE INSTALLATION OF TEMPORARY FACILITIES, AND THE WORK OF MAKING FINAL CONNECTIONS TO NEW WORK SHALL BE DONE ONLY AT SUCH TIMES AS PERMITTED AND SCHEDULED BY THE OWNER WITHOUT ADDITIONAL COST. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE THE SERVICE INTERRUPTIONS WITH THE OWNER AND GENERAL CONTRACTOR. M ELECTRICAL SYMBOL LEGEND All mounting heights to be as shown unless otherwise noted. LIGHTING FIXTURES 2' X 4' FLUORESCENT Q 1' X 4' FLUORESCENT I--� FLUORESCENT STRIP 0 DOWN LIGHT CEILING MOUNTED ® DOWN LIGHT RECESSED MOUNTED I-0 WALL MOUNTED v v TRACK WITH TRACK HEADS EMERGENCY LIGHT - BATTERY UNIT 0 EXIT SIGN W/ BATTERY UNIT t� POLE MOUNTED SITE LIGHT FIXTURE 2' X 4' FLUORESCENT W/ EMERGENCY OR NIGHT LITE CIRCUIT ® DOWN LIGHT RECESSED W/ EMERGENCY OR NIGHT LITE CIRCUIT ® FIXTURE TYPE DESIGNATION. SEE FIXTURE SCHEDULE A: DENOTES FIXTURE TYPE. O RECESSED, SEMI - RECESSED, SURFACE OR PENDANT MOUNTED 2a FIXTURE. 2 - CIRCUIT NO. 'a' IS SWITCH LEG. WIRING DEVICES 0= DUPLEX GROUNDING RECEPTACLE MOUNTED 18" AFF - 20 AMP. 8- SINGLE GROUNDING RECEPTACLE MOUNTED 18" AFF - 20 AMP. DUPLEX GROUNDING RECEPTACLE MOUNTED ABOVE COUNTER - 20 AMP. DUPLEX GROUNDING RECEPTACLE WITH ISOLATED GROUND WIRE MOUNTED 18" AFF - 20 AMP. DUPLEX GROUNDING RECEPTACLE WITH GROUND FAULT INTERRUPTER MOUNTED GFI 18" AFF -20 AMP ® DUPLEX GROUNDING RECEPTACLE FLUSH FLOOR MOUNTED - 20 AMP. QUADRUPLEX GROUNDING RECEPTACLE MOUNTED 18 "AFF - 20 AMP. © MULTI - OUTLET ASSEMBLY W/RECEPTACLES 6" ON CENTER ® SPECIAL PURPOSE RECEPTACLE MOUNTED 18" AFF - DATA AS NOTED SINGLE POLE SWITCH MOUNTED 48" AFF - 20 AMP. 3 THREE WAY SWITCH MOUNTED 48" AFF - 20 AMP. 44 FOUR WAY SWITCH MOUNTED 48" AFF - 20 AMP. D DIMMER SWITCH, 2000 WATT, MOUNTED 48" AFF F FAN SPEED CONTROL SWITCH MOUNTED 48" AFF 4K KEY OPERATED SWITCH MOUNTED 48" AFF - 20 AMP. M HORSEPOWER RATED MANUAL STARTER SWITCH - MTD AT EQUIPMENT W. TELEPHONE OUTLET BOX MOUNTED 18" AFF W ► TELEPHONE OUTLET BOX MOUNTED 54" AFF e TELEPHONE OUTLET FLUSH FLOOR MOUNTED Q CEILING MOUNTED JUNCTION BOX F-Q WALL MOUNTED JUNCTION BOX JD FLUSH FLOOR MOUNTED JUNCTION BOX POWER DISTRIBUTION EQUIPMENT SAFETY SWITCH;3 =POLES, 30 =SWITCH RATING, -FUSE SIZE,PER - -W- FUSE SIZE OR MANUFACTURERS NAMEPLATE LABEL ® CONTACTOR OR MOTOR STARTER BRANCH CIRCUIT PANELBOARD T� DRY TYPE STEP -DOWN TRANSFORMER FIRE ALARM DEVICES ►in 1109}t COMBINATION HORN AND STROBE LIGHT MOUNTED 80" AFF W/75 CANDELLAS + STROBE LIGHT MOUNTED O 80" AFF. F� PULL STATION MOUNTED 48" AFF © FLOW SWITCH © TAMPER SWITCH SPEAKER WITH STROBE LIGHT W/75 CANDELLAS F A FIRE ALARM CONTROL PANEL N® REMOTE ANNUNCIATOR PANEL ® SMOKE DETECTOR ® HEAT DETECTOR ®--. DUCT DECTCCTOR MISCELLANEOUS SO SPEAKER - CEILING MOUNTED Q DOOR BUZZER CALL BUTTON MOUNTED 48" AFF ( -I CALL BUZZER MOUNTED 90" AFF 0 ELEVATOR "DO NOT USE" LIGHT MOUNTED 60" AFF --Q TELEVISION OUTLET MOUNTED 18" AFF TO THERMOSTAT MOUNTED 60" AFF MOTOR ® CARD READER (SECURITY) 1� CCTV SECURITY CAMERA (HEIGHTS VARY) NOTE: THESE ARE STANDARD SYMBOLS AND ALL MAY NOT APPEAR ON PROJECT DRAWINGS. WHEREVER THE SYMBOL ON THE PROJECT OCCURS. THE ITEM SHALL BE PROVIDED AND INSTALLED. Architects Engineers Planners Q f- 901 Ponce de Leon Blvd., Suite 900 Coral Gables, Florida 33134 Voice 305.445.2900 Fax 305.445.3366 AA0002142 EB0005022 L 0 LL U . Z W E W .� O V CL M Q f- m Q� 0 ZO W H L_ L W -C '� 0 uJ J 0 B N U M B E R 01702.01 FILE No. : DRAWN REVIEWED: CHECKED: (;m OED ENGNEERNG, NC. CONSULTING ENGINEERS 1318 S.E 2nd AVE. Certificate No. E80005720 Ft-Lauderdale. Florida 33316 Ph W- 761 -7117 Fz 954- 761 -7915 QED Job 26007 10 7HE BEST OF OUR IOIO"M 1*X PLANS AND SPDCF1CAIM AS SUMMED HOE VM CMPLY MIN 7HE E70 W KTIN4VAIM AND PRONSIOI�S OF_ APPUCABIE BULDNB CCOES. IRIS DFAMNB R '�Ik 901E PROPERTY OP CO MGM= OW A� D IS AN NSIRUM M OF SERVICE NOT 70 K FEPRODUMD r ;=CIDLE CR N PART WMff W E WOO = 1.1 M RN QED DIGICO I6 NC. D A T E 02/23/06 I S S U E R E V I S 1 0 N S S H E E T T I T L E ELECTRICAL NOTES SHEET NU MBE R E�4 "I C_ 1.