5827 SW 77 TERR_EB-10-050-014 Revisions
GENEF1AL PLUMBING NOTES
0
1. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE, FEDERAL 7. PROVIDE MEANS "FURNISH AND INSTALL". 8
ORDINANCES AND BUILDING CODES GOVERNING THE
INSTALLATION OF THE PLUMBING SYSTEM. IF WORK AS LAID 8. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE.
OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS ,P
WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS, . SHOP DRAWINGS: CONTRACTOR SHALL FURNISH THE ENGINEER SITE INVESTIGATION NOTE THE CONTRACTOR SHALL REPORT IN WRITING TO THE WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE
ARCHITECT/ENGINEER BEFORE SUBMITTING A BID. THE FOR APPROVAL. EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK: THE BIDDER IS REQUIRED,
ARCHITECT/ENGINEER WILL THEN ISSUE INSTRUCTIONS AS BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND w
HOW TO PROCEED. 10. AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL FAMILIARIZE HIM OR HERSELF WITH THE NATURE AND EXTENT OF THE WORK AND
GIVE THE OWNER AN AS—BUILT SET OF REPRODUCIBLE SEPIAS ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE
2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT SHOWING THE EXACT LOCATION OF ALL INSTALLATIONS. AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES
NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE NEW AND/OR EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL CONSIDERATION SHALL
MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE 11. PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, NEW FACILITIES AND ALL BUILDING
STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL REQUIRED BY CODE. TEST SHALL BE WITNESSED AND APPROVED STRUCTURES FAMILIARIZE TO HIMSELF WITH ALL EXISTING CONDITIONS. SLIGHT VARIATION
GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW BY PROPER AUTHORITIES. OF ROUTING AND OR CONSTRUCTIONS SHOULD BE ANTICIPATED BY THIS CONTRACTOR TO AVOID cx
DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL CONFLICTS WITH OTHER TRADES. THESE VARIATIONS ARE EXPRESSLY INCLUDED AS PART OF THE —
TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED 12. THE PLUMBING CONTRACTOR SHALL WARRANT ALL WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART "
AND MAINTAIN MAXIMUM HEAD ROOM, AND SPACE CONDITIONS WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM THE DATE OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITY
AT ALL POINTS. WHERE HEAD ROOM, OR SPACE CONDfTONS OF FINAL WORK ACCEPTANCE BY OWNER. ANY BREAKDOWN ASSUMED UNDER THIS CONTRACT.
APPEAR INADEQUATE, ARCHITECT/ENGINEER SHALL BE OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE
NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS TO THE OWNER.
CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD
MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT 13. PROVIDE BATHROOM FIXTURES AS SPECIFIED.
WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION
OF THE WORK . 14. PROVIDE SHUT—OFF VALVE FOR EACH FIXTURE.
J. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. 15. WHEREVER NOT SIMILAR METALS ARE TO BE JOINED, ca
CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND/OR A DI—ELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH
C
0 ca
ONNECT WITH APPROPRIATE SERVICES ALL PLUMBING ITEMS TYPES OF PIPES.
SHOWN ON ANY OF THE ARCHITECTURAL, AIR CONDITIONING,
16. PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING :c:1) 0 1
ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL CONDENSATE DRAIN AND TRAP. SEE AIR CONDITIONING PLANS
EXPENSE TO THE OWNER. IF DISCREPANCIES , CONFLICTS FOR LOCATION OF UNITS AND DRAINS.
INTERFERENCE OR OMISSIONS OCCUR BETWEEN DRAWINGS,
NOTIFY IN WRITING THE ARCHITECT,O ENGINEER IN AMPLE TIME 1 T. MATERIALS — — — — _
B.D. W.C.
TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED. A 3"0(4FU)
A, COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE a cc
4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST TYPE L° COPPER BELOW GROUND AND E M" COPPER ABOVE
CLASS WORKMANLIKE MANNER. THE OWNER RESERVES THE GROUND.
-------------------------- � 3 4FU)
RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS WHICH, B. GOLD WATER PIPES INSIDE OF SLAB SHALL BE TYPE "K°' SOFT —
t A
IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE COPPER INSTALL INSIDE POLYETHYLENE CONDUIT NO JOINTS
APPEARANCE. REMOVAL AND REPLACEMENT IS TO BE DONE I i s L,
ca
IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT PERMITTED INSIDE SLOB. TE ACE w
THE SOLE EXPENSE OF CONTRACTOR. C. SANITARY WASTE AND VENT 4"0 AND SMALLER SHALL BE P.V.C., I ` IVI ASTER s
SCHEDULE 40. BEDROOM i3" 9FU 2"0V.T.R 0
5, START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS D. STORM LINES INSIDE BUILDING SHALL BE P.V.C. SCHEDULE 40
ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO ° I r ( ) I 2"0(iFU)
SUITABILITY OF THE WORK OF OTHER. TRADES OR OTHER E. IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF
CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR BUILDING SHALL BE SCHEDULE 40, PVC. 2"0V
SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL PLUMBING F CONDENSATE DRAIN PIPE SHALL BE SCHEDULE 40, PVC PIPE I i I i MASTER
lqt c:
WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF s BATH
AND FITTINGS. ,
INTERFERENCE WITH OTHER TRADES.
G. WATER HEATER RELIEF AND DRAIN LINE SHALL BE TYPE "L" COPPER,
� " T M a
. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, MIN 304" DIA. — --- -- —— — — — — — — — — — — — — — _ — _ _ — — — _ — — — _ i � " 2 �(iFU � 2"�V CL
FEES, PERMITS , ASSOCIATION DUES, ROYALTIES AND TAXES OF L------------------ ---- --12 0(3FU)
WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL ALSO FIRE RATED PENETARATION NOTE VEN/ PANTRY
PAID ALL THE INSPECTION FEES AS MAY REQUIRED BY LAW OR AICRO
ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY WHEN FIRE PENETRATION OF PIPING OCCUR, SHALL BE PROTECTED 3"0(12FU
DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF LAWS, BY ASSEMBLY No. W—L-2088, UL APPRIVED 2" (2 )
RULES OR ORDINANCES. I I I _ _
C KITCHEN I 1 sH 0 CL
0 U) u—
C I I
C I WIC I I
" cr-
A.V,V 11 I I
MAXIMUM FLOW RATE AND CONSUMPTION 0 0 I I DINING / LIVING � ! � C I WIC
co Lo
FIXTURE COMMON SCHEDULE FOR PLUMBING FIXTURES AND FIXTURE FITTINGS I I RAM M LAUNDRY --- 2"0 CD LINE (OH)
Q IC
WATER ----
p I I I I ROOM --- ---
ITEM WASTE I I 2"0 CD LINE TO C-
D.W. 20' V D DISCHARGE 6'° 6
SOIL CaLD HOT I AFG G AWAY
I
LAVATaTY, PRIVATE 1.� GPM � 60 PSI WATER GLas 3" 10'2� _ I I ! 2°'�(2FU) BEDROOM FROM FOOTING
TUB 2„ 1,02 1,02 Ps ! ! 2 2 0
LAVATORY, PUBLIC 0.5 GPM @ 60 PSI
WHIRLPOOL 2" V T.R 2 102' 102 21
LAVATORY; PUBLIC, METERING BIDET == 1 2" " I I 3"0(9FU) C I ( ) Wl i E �
D.25 GALLONS PER METERING CYCLE 1-1/4 0 1,✓2 3 (2FU) _
OR SELF---CLOSING _
LAVATORY 1-1/4' 112" 1,02' 3" (7FU) 51
SHOWER HEAD 1.5 GPM 0 80 PSI KITCHEN SINK 1-102" 1,02°' 1,/2" _ _ _ — —
=L— "0 15FU) 30
SINK FAUCET 1.5 GPM 60 PSI DISHWASHER 1" hose _ — 102» ® _ — _ A C ® _ — — _ _ ❑ a
URINAL WATER LESS OR " I I TUB ° FOYER TDB BAT I ,A ® G
0.5 GALLON PER FLUSHING CYCLE 2" 1/`2 102 1 1 �`} BN T 2 OV.T.R
WATER CLOSET HOSE BIBB _ 1 =� _ _ I I 2°0 CD LINE TO " (24FU 7FU 3" (4FU I I 2° 1FU a,
1.28 GALLON PER FLUSHING CYCLE 02 I �— DISCHARGE 6 ) G. ( ) 2 0 2FU)
6.5 GALLONS PER CYCLE OR LESS (ENERGY FLOOR DRAINS 2" MIN. 102" ® - I OFFICE I�I 20' (2FU AFG 12"AWAY L. _
B All 1 IH FROM FOOTING
DISWASHER (RESIDENTIAL STARIWATER SENSE CERTIFIED) (C) °-'
DISWASHER (COMMERCIAL) LESS THAN 1.2 GALLONS PER RACK FOR FILL & SHOWER 2" 102" 102" I _ # W.C. — _ _ __ — _ L' -
DUMP MACHINES & LESS THAN 0.9 GALLONS 1 FU) "
PER RACK FOR ALL OTHER TYPES OF MACHINES REFRIGERATOR _ _ 1/2" — _ 3'¢�(4FU)! G ED I 2 �(2FU) 3" V.T:R H W.
17#3 DISWASHER (UNDER THE COUNTER 1.0 GALLON OR LESS PER RACK FOR HIGH—TEMP, NOTE: PROVIDE ANTI SCALD VALVE EACH T 3"0 FU) TUB }
MACHINES) MACHINES & 1.7 GALLONS PER RACK FOR LOW® _ _ I I
TEMPERATURE MACHINES SHOWER AND TUB "
NOTE: ALL TRAPS SHALL BE CONSISTENT WOFt URE OUTLET SIZE, IWH 1. - _ _ — W
WASHING MACHINE WATER FACTOR OF 8 OR LOWER (ENERGY STAR,/
WATER SENSE CERTIFIED) (G) 000'
0 -) w :2
_ _ -
2
4"0(38FU)
-HAMMER
— AMT T EDRQaM EDRf G� -��� z .B
ALL SANITARY PIPE 2 102 ROL MODEL 500
INSTALL IN ACC. LOCATION. PROVIDE OPEN FULL VALVE BY THE " (0 OR SMALLER o
— CONNECTION SIZE: 1,02 NPT WATER METER IN CONCRET BOX (EXACT 4®102" LOCATION
— HEIGHT: 4
SHALL RUN @ 104" SLOPE PER L.FT GARAGE I 1
FIELD.) 3" AND LARGER Cap 7 8" SLOPE PER L. I M -
- DIAMETER: 3-318 0
MAX. PRESSURE: 150 PSI
MAX. TEMP: 200' F I I
MAX, SHOCK PRESSURE: 200 PSI
TO BE INSTALLED IN CWS AND HWS —
HIGH POINT FOR EACH GROUP OF Job No. 10-003
FIXTURE SERVICING. NOTE: t
ALL PLUMBING WATER DEVICE
PROVIDE SHUT—OFF VALVE. ALL TUB AND SHOWER SHALL BE 11 1 5Z1 0
ANTISCALDING VALVE 9 110', (TYPICAL) _ ® _ _
Scale SHOWN
ca
FCa
(2W) NEW 470 SL(U.G) (34FU)TO
m BE CONECTED TO EXISTING
cr
NOTE SL LINE IN FRONT OF 2
ca
gi : PROPERTY. (VERIFY EXACT ALL PIPES TO DISCHARGE
MIN, 12" FROM STRUCTURE ALL VTR SHALL BE OFF S LOCATION A FIELD)
A MIN. OF 4'-0" FROM FIRE
PROVIDE WATER HAMMER ARRESTOR AT 0
SEPARATION WALL. WASHER MACHINES IN ACCESS LOCATION. — _ ® _ _ _ — ® __ — _ _ _ _
SEWER PLAN Seal
SCALE: IMF= 11-W AA-26001560
Sheet No.
100%CONSTRUCTION
ca
DOOUMENTS ca