5827 SW 77 TERR_EB-10-050-012 Revisions 0 ca DESIGN 0. HVAC [ DUCT SMOKE DETECTOR X TOTAL SENSME V43 FIRE DAMPER(S) X AHU-1 1000 ,31.0 23.2 67 BQ 2,30 1 5 6 35 RHEEM OR EQ. RHLAHM3017JA 114 314 1 SMOKE DAMPERS X FIRE RATE ENCLOSURE X NOTE AHU-2 1200 35.2 =24.9 67 BO 2,30 1 7 30 45 RHEEM OR EQ. RHLAHM3617JA 5116 7f8 1 FIRE RATED ROOF/FLOOR CEILING ASSEMBLY X � ALL WINDOWS AND DOORS GLASS FIRE STOPPING X SPECS. MUST BE AS FOLLOW. SMOKE CONTROL X U—FACTOR. 1.080 SHGC: 0.75 CONDENSING MAP. TA CD L r7 " M F . �! a LL E MODEL LS-50 50 CFM ca GU-1 31.0 90 230 1 20 25 RHEEM OR EQ. RAPGO30J EF-2 SHALL BE NUTONE"°15.0 SHOWN 0114" W.C, 115 VOLTS, 80 WATTS CEILING MOUNTED WfB,D.D. BUILT—IN. W ca CU-2 35.2 90 230 1 25 30 RHEEM OR EQ. RAPCO36J 74.5 SHOWN ROOF STRUCTURE SEE PROVIDE WfP, CAP LOW AE� PROFILE B.D.D. AT TOP FOR EF-2 SHALL BE "NUTONE" MODEL LS-75 75 CFM DRYER. NO SCREEN FOR @114" W.C, 115 VOLTS, 80 WATTS CEILING MOUNTED BATHROOM PROVIDE INSECT co W1B.D.D. BUILT—IN. SCREEN CM 4-16d NAILS ca THRU PLYWOOD Cc 115 DUCT FROM UNIT (SEE PLAN FOR SIZE & TYPE) 0 TYPICAL ROOF CAP DETAIL GFM CD @ DRYER ANDIZOR TOILET EXH. < 314°' DEEP x 118" CLOSURE. POWERED ACTUATED, N.T.S. PINS. FLANGE. Z CL 2--112" SQUARE WASHERS 12" MAX`. O.C., MIN. 2 PER SIDE. PACK VOID SWf ARMAFLEX THEN RUN REF. PIPING & COAT Wf SILICONE IN WALL SPACE FLEXIBLE DUCT SHALL BE X10 X 1-114- SHEET SEALANT FOR TIGH CD Cc SUPPORTED AT INTERVALS METAL SCR S. HARD TUBING NO GREATER THAN 5 FEET. SOFT TUBING 0 U) LL FIBROUS GLASS t"UIN FASTENED INSIDE C.U. TO SLAB Wf 4-11470 x 1-112" DUCT. �' �� ��,P POWDERED ACTUATED PINS AS PER MANUFACTURER t ���q' SPECS 0 SCREW. POP RIVET �0�` FLEX . DUCT OR SPOT WELD TO F Co UP TO 29 '" p EQUIPMENT FLANGE. CONCRETE SLAB 1-112 WIDE x 26 GA G.M. STRIP AT REFRIGERANT LINES UP CONDENSING SUPPORT. THRU CONCRETE SLAB. UNIT POWER &c CONTROL LOCATION DUCT HANG DETAIL A.H.0 PVC PIPE—RUN UNDER SLAB SEE FLOOR PLAN FOR LOCATION (SCH. 40 W1 SOLVENT WELD JOINTS) USE '`0" 6 AG ca ® A 4"` OR 5" PIPE As REQUIRED MIN. LIQUID LINE W1 0 NOTES: 4" THIKNESS INSULATION Ca 1. CONCEALED OR NOW REMOVABLE JOINTS SHALL NOT BE INSTALLED CONCRETE BASE e BELOW SLAB 2. PVC. SCH. 40 SLEEVE SHALL BE 2" LARGER THAT THE PIPE INSULATION ENCASED, HAVING AN ANGLE NO GREATER THAN 45 DEGREES WITH THE ENCASED REFRIGERANT PIPING REMOVABLE FOR REPLACEMENT SUCTION LINE Wf W E 112 ARMAFLEX REFRIGERANT LINE PIPING DETAIL UNIT MUST BE INSTALLED TO INSULATION & VAPOR WITHSTAND 150 MPH BARRIER HURRICANE FORCE WINDS & ® � = OA NOTE., UNITS SHALL BE CLEAR a) N.T.S. PROVIDE 1"X118" STRAP BY 3" MIN. FROM DRIP LINE. TIE—DOWN TO UNIT E) 13 tm CU MOUNTING DETAIL Z UJ 0 STANDARD 3" WIDE HANGERS Hanget extension to be the sum of the distances between th hangin wires and the duct size, ID Smacna Duct size, Inches aximum anger 4"" EXHAUST DUCT AHU SHALL BE MECHANICALLY Spacing PROVIDE A MIN. OF 4" ATTACHED TO THE SUPPLY AIR 0 48: Wide or grater 4• ft � PLENUM DUCT SPACE WHERE MECHANICAL ATTIC a ess a wi e ON PP and Less than 4.8"" COMPONENTS TO ASSURE SPACE. °' G S deep CONSTRUCTION & GLEANING, CEILING Width between 28 Eft 5GL a�G �P° c 48" and greater ° f than 18" deep R I�j�a� I�G�R ( IN-1 WALLS Less thlan 29" wide 8ft �r; G ( �P� �� 0 -) W and 16 depth or less HA 1 ,�` STEEL HANGER WIRE C01L1HFAT SECTION REP LINES CHANNEL SECTION 1 RR RQ 22 s PROVIDE CAP OFF If Total Minimum Minimum �� � AA Extension is Channel Channel WITH 114 PERFORATED not greater tanauge Profile FAN SECTION FOR VENT to " 18" 22 3"" X 2'° TYPICAL CEILING CABIN EXHAUST FAN 30" 18 3" X 2" / ,dam,,- WITH BACKDRAFT DAMPER, LOW NOISE 12"' MIN. Z USE OF 2" WIDE ,%'` LEVEL AND NO VIBRATION. ,r 22 gauge 2"x 1.5" hangers may be subst'styted 2880 COND. LINE CL for 3 hangers for ducts with widths not over 48 FILTER ACCESS and depths not over 24 provided that not more S $ SEE PLUMBING DWG. than one oint occurs between hangers and the Jf maximum anger s_p acing 4�ft. Exception: When FRONT FACE GRILLE WITH T ' O duct perimeter is 80" or less and does not Q MECHANICAL CONTRACTOR SHALL re uire reinforcement two joints are permitted FASTENING SCREENS PREFAB MTL. p �`�^„ ^~ ® �Hd UETO A WET SHUTDOWN EQUIPMENT G between hangers FRAME IN EVENT OF OVERFLOW. . 10-003 N.T.S. OVERFLOW PROTECTION DEVICE IS EXHAUST FAN HANGING TO BE INSTALLED IN THE BRACKET (ADJUSTABLE) SECONDARY DRAIN CONNECTION, 11 1 5Z1 C) Scale CEILING MOUNTED CABINET SHOWN AZC CLOSET INSTALLATION EXHAUST FAN DETAIL N.T.S.e Cr ca 4 MECHAMCAL DETAILS, SCHEDULES AND NOTES I HE AA-26001560 I Sheet No. 100%CONSTRUCTION DOCUMENTS