5827 SW 77 TERR_EB-10-050-011 Revisions GENERAL ® . NOTES 1, The contractor shall furnish all labor, material and equipment for a complete H.V.A.C, system in accordance with these drawings. The Florida Building Code 2001 and the latest edition of the CL folio win g ublications: MANS B 1 Mechanical Refrigeration (b) NFPA Pamphlets 90A & 91 LEGEND SMACNA (d) ASHRAE. 2. All air conditioning ductwork shall be 1-1 12 " standard duty 24X24 CD-(SEE SCHEDULE) foil reinforced fiberglass (R-q) manufactured logo rinted on the DUCT TO MATCH NECK SIZE TYP. vapor barrier when in unconditioned s ace, and ,3 standard duty �y CEILING GRILLE SEE SIZE SCHEDULE foil reinforced fiberglass (R-4) manufactured logo printed on the DUCT TO MATCH NECK SIZE TYP. vapor barrier in conditioned space or return plenum space. d RAG-( RETURN AIR GRILL)) 3. All exhaust ductwork shat! be Dade gage galvanized sheet metal. VOLUME DAMPER CU#1 CU#2 4. Duct size shown are net free area inside. (D THERMOSTAT REFF, LINES 5. All air devices (diffusers, registers and grilles) shall be al! (UNDER GROUND) 0 alumina construction, with exposed surface chemically treated to pp DUCT MOUNTED SMOKE DETECTOR (SEE DETAIL) receive point to match color or AiR GUIDE or approved equal. SEE F.A. RISER FOR SPECS. 0 6. Provide opposed blade dampers at all diffusers and registers. AiR FLOW DIRECTION ( ARROWS DENOTE — _ — REF. LINES --- -— -- �. (UNDER GROUND) 7. Thermostats shall be combination cooling heating with system 1 WAY, 2 WAY, ETC., SEE PLANS _ EF-1 (SEE DETAIL) Cool / Auto / Heat ,6' Off and Fan On /Auto selector switches. " ° ° ca RETURN OR EXHAUST, SEE PLANS. RED LINES 4-0 GMD(26GA) UP _ 8. Refrigerant pipin shall be copper type '2" with 112" ormaf/ex. t D O insulation shall e provided for suction lines. (OH) �� _ 150 CFM --_ -ROOF CAP, 0 ca WALL MOUNTED SiDE REGISTER, SCREEN 8a B.D.D. — 9. Provide new filters for fan coil before starting. These t 1502.2 i �. filters must also be replaced prior to final acceptance by owner. TERRACE I CT 10. General contractor is to hire an independent Test and Balance F-. { �� s s REF ES 2 company which shall provide ,3 set of the report sign and sealed EXHAUST FAN (OH) by the Professional Engineer from the company prior of acceptance { i MASTER i MASTER of work if required, Q.A.I. OUTSIDE A/R INTAKE { i BEDROOM i I I BATH 10. Mechanical contractor its to provide turning vent at all change of directions ' i or to provide turning radio, all outlets shall have extractors or scuppers. S.R. SiDE REGISTER I � ' � I and shall be installed in accordance with the applicable regulations, I i 7" I / CD CEILING DIFFUSER CG 6X4 i 1 75 CFM CG CEILING GRILLE — — — H.P. HEAT PUMP UNIT (�f PANTRY — — — — — — — — RA -- 150 CFM_____ EF-2 0 F;L,D FULL LOUVERED DOOR ICRQ 17 1 FM DINING / LIVING N CU CONDENSING UNiT I I ROOM x = z M 08 AHU AiR HANDLER UNiT KITCHEN I { Z Z I CG 6X4 7JP Ww W UC UNDERCUT DOOR FOR AiR RETURN I 0 75 CFM Z RTU ROOF TOP UNIT { M I Ii VD MANUAL VOLUME DAMPER I GMD (22G FOR I I ' WIC OOFE /A P THRU { i FULL LOUVER i { I WOOD DOOR AHU#2 I I WI I iNTUMESCEEN i i { { 7, I SR 10X6 PAINTED. 175 CFM Q CG 6X4 �°- 270 CD LiNE (OH) 00 0 75 CFM 8� 1 4 0 GMD 26GA THRU WALL 0 D.W. A RAG DQO ti W/WP CAP, & B.D.D. Wf ca BACK DRAFT DAMPER AS 2"0 CD LINE TO I I I �^°(' "0 PER FBC 504.4 DISCHARGE 6" .., I DIs.7 P n BOX. , +g^® dt HP AFG & 12"AWAY 00 ca SCOPE OF 6"X4" LOUVER ON WALL & FROM FOOTING s WORK: 0�1 9"o 6'0 GMD (22GA) THRU ca { I %- WiC ROOF FOR GAS DRYER THiS MECHANICAL DESIGN CONSIST OF TWO NEW SPLIT SYSTEM INSTALLATION FOR THE I I I I < VENTILATION. ENTIRE HOUSE (2.5 TON & 3.0 TON RESPECTLY) AS SHOWN ON PLAN. -- / SR 10X6 FULL LOUVER ' � � 470 GMD(26GA) P TI�R ENERGY AND HEAT LOAD CALCULATION HAVE BEEN PERFORMED TO DEMOST TE THE 175 CFM WOOD DOOR --� ROOF W/WP AP, BEDROOM � ADEQUACY OF THE SYSTEM PROPOSED, a= 7' PAINTED. < SCREEN & B.Q.D. AS R CG 8X8 7 REF, ED, , 1502.2 150 CFM C) ca � — - - 6" 140 C cc c — _ H AHU#1 SR 6x6 cm 1 100 CFM 1 1 _ LPN { { � ca ca OFFICE [ I „ -1 50 CF4 10 10 NOTE I X < FOYER _ �= „ EF-1 v „ a ° a a 51 ALL MATERIAL USE INTO THE AIR � I I CG 4 — — ® — ® ° o C PLENUM RETURN CLOSET SHALL BE CG 8X6 < CFM AT NONCOMBUSTIBLE MATERIAL. 2" CD LINE TO 125 CFM ,a CG 6X4 10/"o CG 6X4 ® A� 2"AWAY O EKED 75 CFM HALLWAY 2 0 116 1 I GFM EF 1 #J� IL — FRQ�w QTIN E Y I N co — DIST. BOX. 10X10 GAS IW - - -- -�- - - - ---` —� -fn2 N IV M 4880 GMD(26GA) UP THRU 8"X6" LOUVER ON WALL RAG ROOF We°WP CAP, B/RD LOCATED AT 12" BELOW SCREEN & B.D.D. AS PER ROOF OVERHANG SOFFIT 15 _ 02,2 G CL AND ANOTHER 6" ABOVE — — — 12X10 V — — — UL F go C� LOOR FOR VENTILATION. — — 4"0 GMU(24GA) DOUBLE 4"0 GMD(26GA) UP THRU WALL ROOF FOR EXHAUST FLUE PIPE GASSES� p, ROOF W/WP AP, 81RD qo 7 7 SCREEN & B.D.D. AS PER 1502.2 BEDROOM 4 BEDROOM GARAGE { 1 .SITE INVESTIGATION NOTE. 0 001 CG 10X8 I 200 CFM I EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK. THE BIDDER IS REQUIRED, { BEFORE SUBMITTING HiS PROPOSAL, TO ViSiT THE SiTE OF THE PROPOSED WORK AND FAMILIARIZE HiM OR HERSELF WITH THE NATURE AND EXTENT OF THE WORK AND Z ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES La NEW AND/OR EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL CONSIDERATION SHALL e BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, NEW FACILITIES AND ALL BUILDING STRUCTURES FAMILIARIZE TO HiMSELF WITH ALL EXISTING CONDITIONS. SLIGHT V ARIATION — — - — — — — — OF ROUTING AND OR CONSTRUCTIONS SHOULD BE ANTICIPATED BY THIS CONTRACTOR TO AVOID CONFLICTS WiTH OTHER TRADES. THESE VARIATIONS ARE EXPRESSLY INCLUDED AS PART OF THE W 0 co ORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART >. . ; OF THE CONTRACTOR WILL IN NO WAY RELIEVE HiM OF THE OBLIGATIONS AND RESPONSIBILITY ASSUMED UNDER THiS CONTRACT. Job . 10-003 2 - - _ _ ® _ — _ ® _ - - - - - _ — _ - - Date 11 15 10 - - - - _.. - - - --._.. __.. - - _.__- - - - - SHOWN A 2 CD MECHANICAL PLAN Seal 85 heet No. 100%CONSTRU011ON DOCUMENTS as