07-562-0221. FIRE ALARM SYSTEM SHALL BE U.L. LISTED NFPA 72 APPROVED. 2. UPON ACTIVATION OF FIRE ALARM SYSTEM BY MANUAL STATION, THE FOLLOWING SHALL TAKE PLACE: A ENERGIZE ALARM SIGNALING DEVICES B SOUND AUDIBLE ALARMS AND FLASH VISUAL SIGNALS C ALERT LOCAL FIRE DEPARTMENT OR PROPRIETARY SYSTEM D CAUSE ZONE IN ALARM TO BE DISPLAY ON THE ANNUNCIATOR 3. ALL WIRING AND CONDUCT SIZE SHALL BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND REQUIREMENTS OF NEC, LOCAL CODES AN6 NFPA IN NO CASE. SHALL THE WIRING BE SMALLERTHAN • 16. 4. ALL CONDUCTORS SHALL BE COOPER AND SHALL BE SIZED FOR A MAXIMUN LOSS OF IdB. MINIMUM WIRE SIZE SHALL BE AS REQUIRED BY MANUFACTURER IN NO CASE. SHALL THE WIRING BE SMALLER THAN • 16 F.P.L. CU IN. 3/4 CONDIUT. 5. QUANTITY OF WIRES PER DEVICES SHALL BE AS REQUIRED BY MANUFACTURER. 6. RISER INTERCONNECTIONS ARE DIAGRAMMATIC ONLY. 7. SYSTEM TO BE POWER LIMITED. arm Plan- 2nd Level Existing Areas :)f this Project Scope 8. VISUAL ALARMS PER ANSI A 117.1,4.26, AND A.D.A. 9. ACTIVATION OF SMOKE DETECTOR IN ANY ELEVATOR LOBBY OR ASSOCIATED ELEVATOR MACHINE ROOM 0 tHER THAN AT THE DESIGNATED LEVEL, SHALL Fire Alarm S y m b o I Legend CAUSE ALL CARS THAT SERVE THAT LOBBY TO RETURN NON -STOP TO THE DESIGNATED LEVEL. THE OPERATION SHALL CONFORM TO THE REQUIREMENTS OF RULE 211.3a OF ASME /MISIA17.1 -1987 AS ADOPTED BY CHAPTER (E) INDICATES EXIST. TO REMOVE L ADA STROBE NOTIFIER • S 1224 SERIES 4A -47 OF THE DEPARTMENT OF INSURANCE, STATE FIRE MARSHALL. PHOTOELECTRIC SMOKE DETECTORS (SEE FLOOR PLANS FOR CANDELA REQUIREMENTS) NO DEVICE, OTHER THAN PHASE ISWITCH (RULE 221.3a) OR THE DETECTOR NOTIFIER • FSP - 851 IN THE LEVATOR LOBBY RO ASSOCIATED MACHINE ROOM SHALL INITIATE PULL STATION NOTIFIER • - - NBG 12 LX PHASE IOPERATION. �_. DUCT SMOKE DETECTOR NOTIFIER IF THE SMOKE DETECTOR AT THE THE DESIGNATED LEVEL IS ACTIVATED FSD -751P WITH SAMPLING TUBES ELEVATOR WARNING LIGHT "DO NOT USE" THE CARS SHALL RETURN TO AN ALTERNATE LEVEL APPROVED BY W O HEAT DETECTOR NOTIFIER • FST - 851 • SPACE AGE SSU-0062 ENFORCING AUTHORITY, UNLESS THE PAHSE ISWITCH (RULE 221.3a) IS IN THE ON POSITION. (13710 LP — BASE) H ADA HORN /STROBE NOTIFIER • P1224• FACP FIRE ALARM ADDRESSABLE PANEL SERIES (SEE FLOOR PLANS FOR 10. SMOKE DETECTORS TO BE MOUNTED 3FTMINIMUM FROM ANY A/C DIFUSSER. FACP • AFP -200 PROVIDED WITH (2) LINE DIALER, CANDELA REQUIREMENTS) POWER SUPPLIES BATTERIES, ETC., AS 11. CONTRACTOR DSSRALEDNSI A FLORIPROVIDINGER D ENGINE PERMIT DRAWINGS REQIRED. PROVIDE "LCD' REMOTE ANNUNCIATOR LCD 80". 4 Fzz1T- � - - , r ..y L :B i?l. BROCKHOUSE� BROCKHOUSE ASSOCIATES PA 1570 MADRUGA AVENUE PH 1 CORAL GABLES, FL. 33146 305 666 2333 ■ FAX 666 2332 AR 10682 AA 0002456 BRUCE BROCKHOUSE ARCHITECTURE ■ INTERIOR DESIGN PROJECT A Renovation For The: THE CENTER FOR ARTHRITIS AND RHEUMATIC DISEASES 6150 Sunset Drive South Miami, FI 33143 305 661 2299 SEAL v VV •� K, 4- T� FIRE ALARM PLAN 2ND LEVEL SHEET TITLE 03027- faldgn SHEET TITLE REFERENCE 9 5 L DESIGNS. D FOR USE ON, AND IN CONJUNCTION WITH, THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS. ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON. FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF: BROCKHOUSE ASSOCIATES, PA. REVISION DESIGNED BY B.A. DRAWN BY B.A. APPROVED BY M.W. DATE 5 -17 -05 SCALE 1/4"= 1 I -oil PROJECT N0. 03027 SHEET N0. FA.2