07-562-019General EIEDctrical Notes 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL 13. ALL CONDUCTORS SHALL BE COPPER. CON DUIT ELECTRICAL CODE, FLORIDA BUILDING CODE AND OTHER REMARKS CKT. NO. CKT. NO. APPLICABLE CODES AND STANDARDS. 14. ALL MATERIALS SHALL BE U.L. APPROVED. 2. THE CONTRACTOR IS RESPONSIBLE FOR EVALUATING FIELD 15. NEW TYPEWRITTEN PANEL TALLY SHALL BE FURNISHED AFTER JOB IS COMPLETED REFLECTING ALL CHANGES AND ADDITIONS. 2 CONDITIONS BY VISITING THE SITE PRIOR TO COMMENCING/ Ya" 8 EXISTING AHU (_) BIDDING WORK. 16. ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED. 3. THE CONTRACTOR SHALL SATISFACTORLY REPAIR/ REPLACE 17. CONTRACTOR SHALL SEAL FLOOR CPENINGS WITH A FIRE SEAL SIMILAR 31120 EQUIPMENT OR PART OF STRUCTURE DAMAGED AS A RESULT OF HIS 2 TO 'OZ' FLAMESEAL. 1 WORK. SURFACES AND FINISHED AREAS SHALL BE RESTORED TO 12 EXISTING CKT MATCH ADJACENT AREAS. 18. ALL NON- POWER RELATED WIRING IN CEILING AIR CONDITIONING 12 1/2" 20 PLENUM RUNNING WITHOUT CONDUIT SHALL BE TEFLON COATED 4. APPROVAL SHALL BE OBTAINED FROM THE ENGINEER PRIOR TO CLASSIFIED FOR USE IN PLENUMS. CUTTING OR DRILLING ANY STRUCTURAL SUPPORT MEMBER. 19. ALL EMPTY CONDUIT TO BE PROVIDED WITH NYLON PULL STRINGS. 5. ALL DEVICE BOXES SHALL BE INSTALLED FLUSH AND CONDUITS EXISTING CKT 12 1/2" RUN CONCEALED IN FINISHED AREAS EXCEPT AS SPECIFICALLY 20. FUSES SHALL BE DUAL ELEMENT, TIME DELAY UNLESS OTHERWISE NOTED. SHOWN /NOTED OTHERWISE. 6. ALL ELECTRICAL EQUIPMENT SHALL BE REMOVED FROM STRUCTURE 21. CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER TRADES IN TO BE REMOVED. ACCESSIBLE RACEWAYS, WIRES, BOXES, ORDER TO FURNISH AND INSTALL ALL CONTROL WIRING AND RACEWAYS, ALL POWER CONTROL CIRCUITS WIRING AND RACEWAYS AS SHOWN ON THE 10 SWITCHES AND OTHER ELECTRICAL ITEMS ASSOCIATED WITH THIS AIR CONDITIONING DRAWINGS OR SPECIFICATIONS. IF AIR CONDITIONING WORK SHALL BE REMOVED IF NOT REQUIRED FOR NEW EQUIPMENT TO CONTINUE IN SERVICE. DRAWINGS REFER TO MANUFACTURER'S WIRING DIAGRAMS, THE CONTRACTOR SHALL VERIFY WITH SAID MANUFACTURER ALL REQUIREMENTS AND INCLUDE ALL 7. WIRE SHALL BE REMOVED BACK TO SOURCE FROM INACCESSIBLE EXISTING CKT RELATED WORK IN HIS CONTRACT. 1/2" RACEWAYS NOT REUSED. INSTALL BLANK PLATES IN FLUSH 1 1,000 1,000 OUTLETS NOT REUSED. PLATE COLOR SHALL MATCH ADJACENT SURFACE AS NEAR AS POSSIBLE IN FINISHED AREAS. 22. ALL LUMINARIES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE CEILING SYSTEM MANUFACTURER RE COME NDATIONS AND LOCAL CODE REQUIREMENTS. 8. MODIFY AND REROUTE EXISTING WIRING AS REQUIRED TO ACCOMPLISH INDICATED WORK AND CONTINUE SERVICE TO LOADS 23. RISEN ARE DIAGRAMATIC ONLY. THEY DO NOT SHOW EVERY BEND REQUIRED BEYOND AREA IN WHICH WORK IS DONE. FOR THE INSTALLATION. 9. INSTALL POWER AND CONTROL WIRING AND REQUIRED CONTROL COMPONENTS FOR AIR CONDITIONING SYSTEMS AS SHOWN /NOTED 24. THIS DRAWING IS A GUIDE FOR THE INSTALLATION OF ELECTRICAL SERVICE. ON THESE DRAWINGS AND PER OTHER APPLICABLE DRAWINGS/ THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING 16 INSTRUCTIONS. SEE AIR CONDITIONING DRAWINGS. SYSTEM. 10. ALL MATERIAL REMOVED SHALL BE DISPOSED OF AS DIRECTED 25. ALL CABLES SHALL BE RUN WITHOUT SPLICES EXCEPT OTHERWISE INDICATED_ BY OWNER. 700 500 26. ALL PULL AND JUNCTION BOXES SHALL BE ACCESSIBLE AT ALL TIMES. 11. ALL WIRING INDICATED AS EXISTING IS BASED ON ORIGINAL CONTRACT DRAWINGS AND IS TO BE VERIFIED BY CONTRACTOR AT 27. EXACT POINT AND METHODS OF CONNECTION SHALL BE DETERMINED IN FIELD. 18 JOB SITE. 28. ALL WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. 12. WIRE SIZE SHALL BE # 12 THHN /THWN UNLES OTHERWISE NOTED IN PLANS. 1,200 500 CONDUCTOR 6 AND LARGER SHALL BE THW. \ \1 F.1 �'r; ELECTRIC CHECK NA111 OT WATER I i',': \'i FR EQIPMENT, U U1I'yIENT TO Oii`I "; \Ir! AND OTHER E Q CORRECT IRE SI ZES P,N1? PROTECTION. 20 OVERCURRENT .AD UA F VCAIIIAC- l'i' "SUBJECT TO BE PROVIDET) SUT3.IECTT0 EI.ECFRICA1 FIELD INSPECTION" INSPECI'Inr! EXIST PNL „c,► 3rd Floor existing 4 *1/0 - 2" C to a 3P - 150A BKR Partial Electrical Riser Diagram N.T.S. a VOLTAGE 120/208V, 30, 4W TYPE _ EXISTING PANEL "C" BUS 150A MAIN M.L.O. LOAD 33.8 KVA / 360V = 93.9 A LOAD POLE TRIP CON DUIT IRE REMARKS CKT. NO. CKT. NO. REMARKS WIRE CON DUIT ' TRIP POLE LOAD 4,160 2 40 Ya" 8 EXISTING AHU (_) EXISTING CU (_) 10 Ya" 30 2 31120 3 2 1,000 1 20 1/2" 12 EXISTING CKT 5 6 EXISTING CKT 12 1/2" 20 1 720 1,0 00 ,00 7 8 EXISTING CKT 12 1/2" 20 2 2,000 9 10 700 11 12 EXISTING CKT 12 1/2" 20 1 1,000 1,000 13 14 700 1,200 15 16 700 500 17 18 1,200 500 19 20 1,200 2,000 2 20 %2" 12 EXISTING CKT 21 22 1,000 23 24 700 800 1 20 %2" 12 NEW LIGHTS 25 26 NEW ROOF REC 12 1/2" 20 1 200 10,707 2 70 11 /4" 4 NEW AHU {_) 27 28 NEW CU {_) 6 1" 45 2 4,430 29 30 NOTES: (_) NON. CONCURRENT LOADS. FB7ROCKHOUSE BROCKT-IOUSE ASSOCIATES PA 1570 MAI7RUCJA AVF_NIJE PI-11 i CORAL CiA13Lh'S, 1,'L. 33146 305 666 2333 ■ FAX 666 2332 J 1! �1 ARGHTECTURE PROJECT A Renovation For-The: THE CENTER FOR ARTHRITIS AND RHEUMATIC DISEASES 6150 Sunset Drive South Miami, FI 33143 305 661 2299 SEAL • �. r �kA.liv Q : ua Q ,r • .``�1' -•IAN• .• � r'i 1 I INNOVATIVE E ENGINEERING GROUP, INC. SUDHIR K. GUPTHA P-E. # 29189 5532 N.W. 72 AVE. MIAMI, FLORIDA 33166 305- 888 -9626 SHEET TITLE ELECTRICAL SCHEDULES, NOTES, & DETAILS SHEET TITLE REFERENCE 03027- elecdet.dgn ALL CONCEPTS. DESIGNS. ARRANGEMENTS. DRAWINGS AND SPECIFICATIONS ARE OWNED BY, AND ARE THE PROPERTY OF THIS OFFICE AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON, AND IN CONJUNCTION WITH. THE SPECIFIED PROJECT. NONE OF SUCH IDEAS. DESIGNS. ARRANSE:ENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON. FIRW OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERIIISSIM OF: BROCKHOUSE ASSOCIATES, PA. REVISION DESIGNED BY S.A. DRAWN BY B.A. APPROVED BY L. C. DATE -x._05 SCALE AS NOTED PROJECT NO. 03027 SIIFET NO. r- Fs2