07-562-012GENERAL STRUCTURAL NOTES THESE DRAWINGS ARE INTENDED TO SHOW THE GENERAL ARRANGEMENT, DESIGN AND EXTENT OF THE WORK AND ARE PARTIALLY DIAGRAMMATIC. THEY ARE NOT INTENDED TO BE SCALED FOR ROUGH -IN MEASUREMENTS, OR TO SERVE AS SHOP DRAWINGS. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (HIGH VELOCITY HURRICANE ZONES), 2001 EDITION. WIND PRESSURES HAVE BEEN DETERMINED IN ACCORDANCE WITH ASCE 7 -98. V -146 MPH (DADE COUNTY), 1 -1.0. EXPOSURE C. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO STARTING ANY WORK AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BETWEEN THESE PLANS AND THE EXISTING CONDITIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF EXISTING STRUCTURE DURING CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION MEANS AND METHODS AND JOB SITE SAFETY. CONTRACTOR SHALL EXERCISE ALL DUE CARE DURING DEMOLITION. EXCAVATION AND CONSTRUCTION TO PROTECT WORKERS AND EXISTING CONSTRUCTION. CONTRACTOR SHALL NOT LOAD NEW OR EXISTING STRUCTURES BEYOND THEIR DESIGNED CAPACITY. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SHORING AND BRACING REQUIRED DURING CONSTRUCTION. CONTRACTOR SHALL ATTEMPT TO LOCATE CONCEALED AND UNDERGROUND PIPES, CONDUITS ETC. PRIOR TO COMMENCEMENT OF WORK. THE CONTRACTOR IS RESPONSIBLE AND SHALL COMPLY WITH THE SAFETY REQUIREMENTS OF CHAPTER 33 OF THE FLORIDA BUILDING CODE AND ALL LOCAL,STATE AND FEDERAL LAWS. COMPRESSIVE STRENGTH OF CONCRETE AT 28 DAYS SHALL BE 3000 PSI. ALL CONCRETE WORK SHALL CONFORM TO AC1301 SPECIFICATIONS U.O.N. CONCRETE SLUMP SHALL BE 3" PLUS OR MINUS 1" FOR FOOTINGS AND SLABS ON GRADE: 4" PLUS OR MINUS 1" FOR OTHER CONCRETE. USE LIGHTWEIGHT CONCRETE FOR TOPPING OVER EXISTING SLAB. MAX CONCRETE DENSITY 110 PCF. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A -615 GRADE 60 AND SHALL BE NEW, FABRICATED AND DETAILED IN ACCORDANCE WITH ACI315. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A -185 AND SHALL BE SUPPORTED ON PIECES OF BRICK AT A MAXIMUM SPACING OF 36 INCHES C/C EACH WAY. LAP FABRIC A MINIMUM OF 6 INCHES AT THE SIDES. SPLICES IN REBARS SHALL BE A MINIMUM OF 36 BAR DIAMETERS U.O.N. ALL HOOKS IN REBARS SHALL BE STANDARD ACI318 HOOKS. CONCRETE COVER OVER REINFORCEMENT SHALL BE AS FOLLOWS= BOTTOM AND SIDES OF GRADE BEAMS/ FOOTINGS ............................3" TIES IN COLUMNS AND STIRRUPS IN BEAMS ............ .........................1 -1/2" BOTTOM REINFORCEMENT FOR GROUND FLOOR SLAB .........................211 OTHER SLAB REINFORCEMENT ................................. .........................1 -1/2" WET (NOT FLOOD) THE FORMS, REBARS AND BOTTOM OF ALL FOOTING EXCAVATIONS IMMEDIATELY BEFORE PLACING FOOTING CONCRETE. PUDDLES OF WATER ARE NOT ACCEPTABLE. FOOTING SIDES MUST BE FORMED IF EXCAVATION IS NOT STABLE. CONTRACTOR IS RESPONSIBLE FOR STABILITY OF EXCAVATION. DESIGN LOADS SHALL BE AS FOLLOWS: ROOF DEAD LOAD .......... .............................25 PSF ROOF LIVE LOAD ......... .............................30 PSF SECOND FLOOR DEAD LOAD ......................30 PSF SECOND FLOOR LIVE LOAD ....................50 PSF STRUCTURAL STEEL SHALL CONFORM WITH ASTM A -36 FOR PLATES AND SHAPES AND TO ASTM A -500 FOR RECTANGULAR TUBING. ROUND PIPES SHALL CONFORM WITH ASTM A -53. ANCHOR BOLTS SHALL CONFORM TO ASTM A -307. STRUCTURAL BOLTS SHALL CONFORM TO ASTM A -325 AND SHALL BE BEARING BOLTS UNLESS OTHERWISE NOTED. ALL WELDING SHALL BE IN ACCORDANCE WITH AWS STANDARDS AND SHALL BE PERFORMED BY CERTIFIED WELDERS. STRUCTURAL STEEL SHALL BE SHOP PRIMED WITH A CORROSION INHIBITING PRIMER AND PAINTED WITH A COMPATIBLE PAINT AS REQUIRED BY THE ARCHITECT AND /OR OWNER. SURFACE PREPARATION, PRIMING AND PAINTING SHALL CONFORM TO THE REQUIREMENTS OF THE SSPC. STRUCTURAL STEEL TUBULAR COLUMNS SHALL BE CONCRETE FILLED. STRUCTURAL STEEL ITEMS EXPOSED TO WEATHER SHALL BE HOT DIPPED GALVANIZED AND PAINTED WITH A COMPATIBLE PAINT AS REQUIRED BY THE ARCHITECT AND /OR OWNER. EXPANSION BOLTS INDICATED IN THESE DRAWINGS SHALL BE HILTI KWIK BOLT II SYSTEM OR EQUAL CONFORMING TO MATERIAL SPECIFICATIONS FOR STUD, WEDGE. NUT AND WASHER INDICATED BY HILTI SYSTEM. BOLTS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER SPECIFICATION TO OBTAIN ALLOWABLE SHEAR AND TENSION CAPACITY INDICATED IN HILTI CATALOG. WHERE STEEL REINFORCING BARS ARE INDICATED TO BE SET IN EPDXY, SYSTEM SHALL BE HILTI HSE 2411 EPDXY SYSTEM CONFORMING TO ASTM C 881 OR EQUAL INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. STEEL JOISTS SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE STEEL JOIST INSTITUTE REQUIREMENTS FOR K SERIES JOIST. STEEL JOISTS SHALL BE DESIGNED TO SUPPORT THE SUPERIMPOSED LOADS INDICATED IN THE FRAMING PLANS. STEEL JOIST DESIGNER SHALL DESIGN BRIDGING FOR THE NEXT UPLIFT PRESSURE INDICATED IN THE ROOF FRAMING PLAN IN ACCORDANCE WITH SA REQUIREMENTS. STEEL ROOF DECK SHALL BE MANUFACTURED FROM STEEL CONFORMING TO ASTM DESIGNATION A611, GRADES C,D, OR E OR FROM A446 GRADES A.B,C.D,E. OF F. THE STEEL USED SHALL HAVE A MINIMUM YIELD STRENGTH OF 33 KSI. THE DELIVERED THICKNESS SHALL NOT BE LESS THAN 957 OF THE DESIGN THICKNESS. SUBMIT SHOP DRAWINGS FOR THE FOLLOWING ITEMS: (MINIMUM 3 READABLE SETS OF PRINTS) STEEL JOISTS INCLUDING CALCULATIONS SIGNED & SEALED BY A FLORIDA REGISTERED ENGINEER. Y4 CDX plywood (see plan) HSS6X2X0.25 (see plan weld tube to cont. angle) L 6 X 4 X 5fi6 rtop chord joist extension cont. welded 0 ea. jst. / W 14 X 43 steel joist (see plan) L 2 %2X 2%2X1/40 ea vert. tube welded to tube and W 14 X 43 L 2 %2X 2%2X1/40 ea vert. tube welded to horiz. angle and to W 14 X 43 Section F 3/4" = 1'- 0" - - -- J_ 11 II 11 J!— V R11 I— Section A - Concrete Floor Slab n.t.s. Y4" dia bolt in slotted hole 0 48" c/c insulating conc. topping 411.2-8.1 metal deck L 4 X 3 XI /4cont. w/ vertical slotted hole (cut vertical leg 0 steel beams Detail B 1 1/2"= 1' -0" steeldeck (see roof framing plan) /�— steel joist / (see roof framing plan) extend bottom chord of joist & weld to angle after all roof dead loads are applied Section D 3/4" = 1'- 0" exist. conc. slob— (2)Y2" dia. X 31/2" long expanstion bolts spaced 0 3" c. /c. exist. conc. slab exist. conc. beam beyond— R_%" x 611 x 611 Q 4' -0" c. /c. 3—/ h horiz. to vert. plates 716 -%X 6 X 6" welded to horiz. plate 0 4' -0" c/c X v E V14 x 43 W. 1/2" x 4 x 8 w/ (2 *4" dia. ASTM A325 thru bolts to bottom flange of beam 3 x 2' -0" back plate 3 %2x 1'- 11%2" side plates .,,,,, ...... x 10" in embedment HILTI HAS bolts Section C - Steel Beam Connection 1 1/2"= 1' -0" )f4" CDX plywood sheathing welded a ea. joist .. bracing 42 ea. bridging cont. 2Y2topping ►. v. v. vv... vv.. v... vv.... vv. Y4" CDX plywood sheathing see plan 1%2" metal deck. 91 Section E - Steel Bridging End Condition 3/4" = 1'- 0" FBROCKH07US7E7] BROCKHOUSE ASSOCIATES PA 1570 MADRUGA AVENUE PH 1 CORAL GABLES, FL. 33146 AR 10682 AA 0002456 BRUCE BROCKHOUSE ARCHITECTURE ■ INTERIOR DESIGN PROJECT A Renovation For The: THE CENTER FOR ARTHRITIS AND RHEUMATIC DISEASES 6150 Sunset Drive South Miami, FI 33143 305 661 2299 SEAL ,c: SHEET TITLE STRUCTURAL NOTES & DETAILS SHEET TITLE REFERENCE 03027- struddet1.dgn ALL CONCEPTS. DESIGNS. ARRANGEMENTS. DRAWINGS AND SPECIFICATIONS ARE OWNED BY. AND ARE THE PROPERTY OF THIS OFFICE AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON, AND IN CONJUNCTION WITH, PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS' OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON. FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF: BROCKHOUSE ASSOCIATES. PA. REVISION DESIGNED BY B.A. DRAWN BY B.A. APPROVED BY M.W. DATE 5 -17 -05 SCALE 1/4"= 1 ' -0" PROTECTNO. 03027 SHEET N0. S.5 t ' O 5-l- . f , 't�ar`i1A, ' .. � bra • .. "t�� S N. OSCAR GONZALEZ, P.E. CONSULTING STRUCTURAL ENGINEER P.E. # 31964 STRUCTURAL 11462 S.W. 75 TERR. MIAMI, FLORIDA 33173 305-696 -4874 SHEET TITLE STRUCTURAL NOTES & DETAILS SHEET TITLE REFERENCE 03027- struddet1.dgn ALL CONCEPTS. DESIGNS. ARRANGEMENTS. DRAWINGS AND SPECIFICATIONS ARE OWNED BY. AND ARE THE PROPERTY OF THIS OFFICE AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON, AND IN CONJUNCTION WITH, PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS' OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON. FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF: BROCKHOUSE ASSOCIATES. PA. REVISION DESIGNED BY B.A. DRAWN BY B.A. APPROVED BY M.W. DATE 5 -17 -05 SCALE 1/4"= 1 ' -0" PROTECTNO. 03027 SHEET N0. S.5