07-562-004C
a
K
new addition 110-411 — existing building
47+_Au
verity Mn tNew
Window Schedule
❑
Size (WxH)
Description
FRAME
GLAZING
Remarks
Remarks
North
South
FINISH
FINISH
Finish
Height
300
FIXED TEMPERED IMPACT RESISTANT
CONC.
VINYL
PAINT /DRYWALL
A
5' -10" X 4' -0"
(CAT. II) GLASS PANEL STOREFRONT
E.S.P WHITE
BRONZE TINT
3 EQUAL PANELS TO ALIGN W/ EXIST
V.I.F.
SYSTEM.SUBMIT ENGINEERING
(MATCH EXIST.)
(MATCH EXIST.)
VERT. MULIONS BELOW
SHOP DRAWINGS
32' -3" X 4' -0"
FOR ARCHITECT'S /ENGINEER'S
E.S.P WHITE
BRONZE TINT
10 EQUAL PANELS TO ALIGN W/ EXIST
B
V.I.F.
APPROVAL (SEE PARTION DETAIL
(MATCH EXIST.)
(MATCH EXIST.)
VERT. MULIONS BELOW
SHEET A.7)
18' -0" X 4' -0"
FOR ARCHITECT'S /ENGINEER'S
E.S.P WHITE
BRONZE TINT
6 EQUAL PANELS TO ALIGN W/ EXIST
B
V.I.F.
APPROVAL (SEE PARTION DETAIL
(MATCH EXIST.)
(MATCH EXIST.)
VERT. MULIONS BELOW
SHEET A.7)
NOTES:
1. All Exterior Windows Shall Be Impact Resistant & Dade County Product Control Approved.
2. Contractor Shall Verify All Window Heights & Overall Sizes At Field Before Fabrication. Contractor Shall Notify Architect In Case of Discrepancies.
3. Contractor Shall Provide Listed Manufacturer Or Approved Equal Including All Relevant Product Control Approval Numbers And Shop
Drawings For Architect's Approval.
Finish Schedule - 3rd Level
Room
No.
Location
Floor
Base
Walls
Ceilings
Remarks
North
South
East
West
Finish
Height
300
OFFICE STORAGE
CONC.
VINYL
PAINT /DRYWALL
PAINT /DRYWALL
PAINT /DRYWALL
PAINT /DRYWALL
PT /DW
V.I.F.
NOTES:
1. Exact Room Finish Selections as per Owner Specifications
11
2 1y.,,.f, ;T r jLT-1r D
�s`ii� }.tfc••.i i /'�+ �((•�,��• �1 — r!• 1: 1. �..�. ++.. TJ.•!!i•I (J t1
l'DAD _ !''`��T'j , (T(.66�_�.:'t+ pp'}}..;1 .tsar.
SLD3 `�'V 'a. 1 V 1 1 a! j ",a„N;~, Dl-" - r'Tr I
Flr�z u. Pc`Rr.i T / l�- itfi�T?'
DATE
_ Construction Floor Plan - 3rd Level
1/4" = 1' -0"
Denotes Existing Areas Not Part of this Project Scope
Gross Area Calculation
Existing 3rd Level Area: P2427Sq. Proposed Area of New Addition: Total 3rd Level Area:
Wall Legend
(Refer to Sheet A.7 - for Interior Partition Detail)
Existing walls to remain (typical)
Drywall Partition with Sound Attentation
Dryvit Exterior Wall System
Tempered Glass Panel Storefront System
Steel Column with 2 hr. Fire Rated Drywall Cladding
El Refer to Window Schedule this sheet for specifications.
[A
BROCKHOUSE
BROCKHOUSE ASSOCIATES PA
1570 A4ADRUGA AVENUE PH 1
CORAL GABLES, FL. 33146
305 666 2333 ■ FAX 666 2332
ARCI-117ECTURE INURIOR 1
PROJECT
A Renovation
For The:
THE CENTER FOR
ARTHRITIS AND
RHEUMATIC DISEASES
6150 Sunset Drive
South Miami, FI 33143
305 661 2299
SEAL
SHEET TITLE
CONSTRUCTION
FLOOR PLAN
THIRD LEVEL
SHEET TITLE REFERENCE
03027- fir3.dgn
ALL CONCEPTS, DESIGNS, ARRANGEMENTS, DRAWINGS AND
SPECIFICATIONS ARE OWNED BY. AND ARE THE PROUTY OF
THIS OFFICE AND WERE CREATED. EVOLVED AND DEVELOPED
FOR USE ON. AND IN CONJUNCTION WITH. THE SPECIFIED
PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS
OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON,
FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER
WITHOUT THE WRITTEN PERMISSION OF:
BROCKHOUSE ASSOCIATES. PA.
REVISION
J& 3 -29 -05: FIRE DEPT. REV.
A5- 25-05: FIRE DEPT. REV.
DESIGNED BY
B.A.
DRAWN BY
B.A.
APPROVED BY
M.W.
DATE 5 -17 -05
SCALE 1/4 If= 1 ' -0"
PROJECT N0. 03027
SHEET N0.
A.4