Loading...
05-658-0245/8' 'COX' PLYWOOD SHEATHING 1x4 P.T. SEPARATOR �W/ 4 P.T. SEPARATOR CONNECT TO CONIC. CAP. ONNECT TO CONC. CAP. W/ 1/4'0 TAP CON x 31/2'0 16' C/C 1/4'0 TAP CON x 3'i2' • 16' METAL DRIP - 1x2 P.T. NAILER 8X8 SLOPPED CONC. CAP W/ 2 S CONT. W. al�1mFAI ►:1 z31 RT15-1 RTB -I 1% • 32' C /C� (TYPICAL) s • 8 X 8 CONC. LINTEL W/ 2 *5 CONT. 1M'o VER TICAL • 32' C/C 9 GA HORIZONTAL ` BLOCK RE INF. 8 X 8 CONC. SILL W/ 2 S CONT. C 1% 0 32' C/C (TYPICAL) 1% 0 32' C/C (TYPICAL) PREFABRICATED WOOD TRUSSES 0 24'C /C 04012'Tx3' -0' $ T7 NEW 4' CONC. SLAB SEE PLAN FOR REINF. GRADE -Jp x x _ x — x x x x x x x x- > / N-� x �/ //� x = I x ///o, 177 x x ----I I F- -VAPOR BARRIER MONOLITHIC —� — �_ -16- ONOLITHIC SECTION � SCALE: 3/4' = 1' -0' n� SXB ----/ SLOPPED CONC. CAP W/ 2S CONT. 1% VERTICAL 0 32' C/C RB -4 —� I I I I FOR 04012' Tx3';•0' I TYP. NEW 4' CON S AB I I SEE PLAN FOR INF. I I I I x x x x x x 7, UP -30 MONOLITHIC — - LISP 'TAPL -16' W/ 4 -10d TO SEAT PL AND 3-10d THRU STRAP 2' -0' 3 PMI'o DOWEL 0 32' DRILLED 4 EPDXIED 5' INTO EXISTING BEAM 1'x6' T 4G 41 5/8' PWD' CDX" SHEATHING 3'x6' WOOD (BEAM LAG / BOLTED • LAG EA END W/ 2 -5/6'x 1' LONG SANDWICIH WOOD BRACKET 3 /4'�EPDXIEiJ THRU BOLT EL. -i' -9' TOP OF FF!. • I• 8 X 8 CONC. CAP W/ 2 +'S CONT. 1+'6 DOWEL EXISTING CONC. SLAB TO RECEIVE CONC. SEALER WATERPROOFING --7 • b� 0408' HOCKED BARS 0 8 X 6 CONC. LINTEL W/ 2 S CONT. as 19 X UJ EXISTING CONC. SLAB USP HOPT2 W /6 -10d NAILS 5/8' 'CDX' PLYWOOD SHEATHING 12 w U W W H E- 0 z 6 z wA 00 �z 0 • • PREFABRICATED 20 WOOD TRUSSES o w 0 24'C /C O wm SEE ROOF FTRAMING PLAN w RTB -1 ---, 2'x6' P.T. CONT W/ 5/8' OxWeV EXP. BOLTS 024' IN SOLID CONCRETE TOP 4 BOTT •4.12'x3' -5' DRILLED 4 EPDXIED 5' INTO EXISTING SLAB 1t,2' CLEAR NEW 4' CONC. SLAB n /--- 114012'TOP i'i• " "ii• "•iii• "�♦!i!i!iiiii••" • " ' 1ir IF ♦ ♦♦i♦ ♦ •♦♦♦i�i►�♦ Li EXISTM MONOLITHIC VAPOR BARRIER FOOTING BOTTOM SECTION 2 SCALE: 3/4' z I' -0' �J -(o i 21-01 OVERHANG 9 GA 14ORIZONTA BLOCK RE INF. 0 16' C/C IS 0 32' C/C (TYPICAL) 8' CONC. BLOCK 1"5 CONT. LtF -16 MONOLITHIC L Na �E z a as .w d P7 o� w xw �o o >E Ey W p'y 0 04 y1 a� Az UA �a a� V>. E H a a �U Q� a� A� d� Ao �W U EE- ARVELO AND ASSOCIATES, INC STR' . R 56 STRUCTURAL ENGINEERS 4848 SW 74th CT., MIAMI FL. (305) 667 -7628 CERTIFICATE# EB- 0007321 SAL` DATE: 02/02/05 DRAWN: T.M. E KED: A. A. R. tiJ e U� U EL +8' -5' TOP OF T.B. x x �' ` -METAL DRIP �- ix2 P.T. ° U NAILER W W w Uo AA 0 a� w� E+ n E+ 0 ARVELO AND ASSOCIATES, INC STR' . R 56 STRUCTURAL ENGINEERS 4848 SW 74th CT., MIAMI FL. (305) 667 -7628 CERTIFICATE# EB- 0007321 SAL` DATE: 02/02/05 DRAWN: T.M. E KED: A. A. R. tiJ e