Loading...
05-438-001POOL GENERAL NOTES —All Reinf. Steel To Conform To A.s.t.m. A615 Grade 60. All Floor & Walls Of Pool To Be g Pneumatically Applied Conc. With A Min. 28 Day Compressive Strength Of 3000 P.s.i. All Pool T8 Piping To Be Schedule 40 Pvc Non Threaded Nsf Pipe With Solvent Weld Joints. EXIST. 4' —The Design Engineer Accepts No Responsibility For The Safety Of Existing Structures. In All C.LFENCE Cases, The Pool Contractor Shall Take All Precautions To Protect Existing Structures From c7 Failure By Sheathing And /or Shoring Or Other Methods As Required. ,j 10 —0 —The Design Engineer Assumes No Responsibility For Pool Construction In Easement Or Required Setback Areas. Plot Plans Not Prepared From Legal Surveys Of The Existing Lot And 6' -0" Residence Are So Indicated. Pool Contractor Shall Verify All Dimensions In The Field And g :F ., Establish Lot Lines. If Necessary, Pool Contractor And /or Owner Shall Verify Shown And All x a Dimensions Prior To Construction. — Contractor Shall Establish Locations Of Utilities At The Site Minimum Clearance Dimensions Shall Be Held And Shall Be As Required By The Local Regulatory Agency. In General, Hold A Distance Of 10 Feet From Overhead Electric Lines To Pool's Water Edge. —All Pool Enclosures Shall Conform Florida Statutes 515.27 And 515.29 ., And F.b.c. Chapt 424.2.17.1 — 10 �o —Where Pools Abut Or Are Placed Nearby Sea Wall Or Bulkheads, Special Care Shall Be Employed. The Walls Shall Be In Good Condition, Not Permitting Any Shifting Or Removal, Or x Loosening Of The Supporting Soil Away From The Pool. If The Walls Do Not Fully Contain The Soils Behind Them, They Shall Be Replaced Or Repaired. Continual Maintenance Of The Walls Is Required By The Property Owner. When Excavating For The Pool, The Sea —wall Tiebacks Shall Not Be Cut . '- -The Contractor Shall Backfill Pool Shell With Caution. The Plumbing Shall Not Be Disturbed. Backfill Shall Be Performed With Clean Sand, Free Of Organic Materials And Shall Be Placed In 12 Inch Thick Layers. Each Layer Shall Be Compacted To 90% Of The Soils Maximum Density POOL EQUIP. PAD By Tampering Solidly. Soils Below The Deck Shall Be Placed In Similar Manner. Where Decks Are Indicated By Others, The Deck Design Notes Shown On The Typical Section Do Not Apply. Deck Design Shall Be By Others. Do Not Drain Pool Under High Ground Water Or Storm Conditions. —Do Not Empty Pool After Construction For Repairs Or Any Other Reason Before Consulting With A Pool Or Pool Repair Contractor. Hydrostatic Uplift Pressures Must Be Eliminated To EXIST. 4' Prevent Pool From Floating Above Ground, And Causing Damage To The Structural Integrity Of C.LFENCE The Pool. —This Plan Remains The Property Of The Design Engineers. It Is Not Transferable From One Contractor To Another Without The Written Permission Of The Design Engineers. — Install Wiring And Devices As Indicated In Pool Data Shall Furnished Electrical Service At Existing Entry. Install Disconnect Switch At Motor If Not Within 50' Of Fused Switch At Service Point. Electrical Light Connection To Comply With Nec 660 -1575 Art. 680., 2002 Edition. All Metallic Conduits, Piping System, Reinforcing Steel, Lighting Fixtures And Fixture Housing, Metal Parts Of Ladders, And Their Supports, Shall Be Bounded Together And Grounded To A Common Ground. Bounding Conductors Shall Not Be Smaller Than #8 Copper. No Overhead Open Wire Over Pool Water. Receptacles With 10' Of Water. —Pool Light To Be Grounded To Common Bonding Grid Consisting Of (1) #8 Continuous Copper Wire Looped Around Pool Perimeter. Loop Shall Be Grounded To Panel Via Pool Wall Steel, Deck I Reinforcing, And Pump Motor Casing. — Filter Backwash Shall Comply With The Florida Building Code, 2001 Edition. —Pool Water Disposal To Be In Accordance With Florida Building Code, 2001 Edition. — Temperature Of Spa Water Shall Be Set So That Maximum Water Temperature Does Not EXIST. WATER Exceed 102 Degrees Fahrenheit. LINE —Upon Visual Inspection Site Soil Reveals A Combination Of Undisturbed Sand And Limerock. A Bearing Value Of 2000 Psf Has 'Been Utilized For Design Purposes. —Soil Statement: Engineer Of Record Will Perform A Visual Inspection After Excavation Is Done. EXIST. WATER Prepare A Letter Stating The Conditions Found. METER — Access Gate Requirements Per F.B.C. 424.2.17.1.8. amended july /30, 2003: All doors and windows with direct access to the pool through that wall shall be equipped with an alarm which produces an audible warning when the door and its screen are opened. The alarm shall sound continuously for a minimum of 30 seconds immediately after the door is opened and — be capable of being heard throughout the house during normal household activities. the alarm shall automatically reset under all conditions. The alarm shall be equipped with a manual means to temporality deactivate the alarm for a single opening. Such deactivation shall last no more _ the 15 seconds. The deactivation switch shall be located at least 54 inches above the threshold of the door. —All Treads Shall Have Slip— Resistilg Surfaces Per ANSI. 6.1.5 —This Pool Has Been Designed To Al I Applicable Requirements Of The Florida Building Code, Section 424. LEGAL DESCRIPTION LOT 10 & 11, BLOCK 7," SEA VIEW PARK AMENDED ", PB -17, PG -80, SUBDIVISION AMENDED PLAT OF SEA VIEW PARK ONE PLAT BOOK 17, PAGE 80, OF THE PUBLIC RECORDS OF MIAMI DADE COUNTY, FLORIDA POOL & SPA DATA POOL SPECIFICATIONS: SPA SPECIFICATIONS: Pool Shape: AS SHOWN Spa Shape: AS SHOWN Pool Size (FT): 17'x32' Spa Size (FT): 6'x8' Deep End (FT): 6' Spa Area(SF): 37 Shallow End (FT): 4' Spa Perimeter(LF): 22 SF Pool Area(SF). 367 Spa Volume (GAL). 555 Pool Perimeter(LF): 96 Turnover Rate(HR): 0.08 HR Pool Volume (GAL): 13,762 Spa Pump Size (HP): NONE Turnover Rate(HR): 2.18 HR Filter System & Size:NONE Interior Finish: DIAMOND BRITE Spa Raised: 12" Waterline Tile: 6" Jets:4 Coping: B/N BRICK Overflow:2 Pump Size (HP): 3 HP HAYWARD Maindrains: 2 Filter System & Size: 300 SF CARTRIDGE Automatic Surface Skimmer: NONE Inlets: 4 Underwater Safety Light: 100 WATT, 12 VOLT Maindrains: 2 Spa Miscellaneous Items: 2" Vacuum Line w/ Safety Lock: ONE 1 Automatic Surface Skimmer: ONE Underwater Safety Light: (2) 300 W,12 V 2' Patio Finish & Size: 589 SF PAVERS BY OTHERS Deck Drains (LF): NONE Pool Miscellaneous Items: 1. AOUACALL TROPICAL 94,000 BTU HEAT PUMP 2. AUTOPILOT ST -36 PRE -CAST CONC. COPING OR ALTERNATE COPING _ - -- water line` 8 INTERLOCKING PAVERS y ON COMPACTED SAND 11 091 1 @ -Olt 10-6" 6" INSTALLED 12" 24" BELOW WATER " _ water line LEVEL -- -o - - - - - - - - --- - - - -- (RETURN FITTINGS) _ WELL COMPATED L to SHALL BE 6" FILL � o Lo MIN. SHOTCRETE i i o COLOR WALL = CONTRAST �► o TILE 3 ®8 EA. WAY SIDE & _ BOTT. TYPICAL. #3 ® 8 "O /C TYPICAL TYPICAL WALL SECTION TYPICAL STEPS DETAIL SCALE: 1/2"=V-0" SCALE: 1/2"=l'—O" _ I irn O x— I I e If's 1 ' 53 -10" C.B.S. SHED C.B.S. WALL 62' -9" I— —1 EXIST. SANITARY/ LINE FL. J = TO EXIST.SEPiiC TANK I W AND EXIST. DRAINFIELD PORCH EXIST. OVERHEAD POWER SERVICE W EXIST ELECTRIC EXIST. CONC. SLAB TO ' BE REMOVED EXIST. 200 A HOUSE PANEL EXISTING ONE STY CBS RESIDENCE F.F.ELV. 10.0' 100.0' 15' PARKWAY ASPHALT DRIVEWAY SW 48th STREET (y SITE PLAN 1 " = 20' -0" 100% LOT COVERAGE = 14,359 S.F ACTUAL LANDSCAPE COVERAGE = 7,368 S.F = 51 % BUILDING AND POOL COVERAGE = 4,260 S.F = 30 % 1 " to 24 10M X COPING water line _ . t r- COLOR CONTRAST TILE #3 0 8 "0 /C TYPICAL SWIMOUT DETAIL SCALE: 1/2"=V-0" LO EXIST. 5' WOOD FENCE DROP W 6" FOR OVERFLOW SPILL WAY 10" 10" 1' -0" 6" 6" _ O - - - - - -- water Tine — c0 — - -- -- -- - - - - -- I _ _ � O POOL '- MAIN DRAT _ s r 1 1/2" DRAI =N TO PUMP VENT. #3 ® 10" N VARIABLE LENGHT EACH WAY 55 FT MAX EACH FACE TO PUMP SPA SECTION SCALE: 1/2"=1'—O" _ O I Un N o� I 4' -0" 1 1/2" DRAIN VENT. F— C9 Z W J w J m a 2 1/2" PIPE SUCTION LINE 7' -5,r J kill n I 27' -3" 24" SPILLWAY HANDHOLDS = 48" C/C 0 I LO SWIMMING POOL — SWIMOUT _ U I 19' -10" MOUT 3' -0" 6'— 0" o DEEP _ 0 I 0 = 5' -6" co Ig O I DEEP SWIMOUT 4' -0" 9' -9" 22' -1" ns�■ 3' -0" DEEP 10' -6" POOL DEC,-\,.K + 8.00' (PAVERS DECK) (BY OTHERS) ?S. `7 e EXISTING RESIDENCE 8' -10" I CHILD SAFETY FENCE (BY o OTHERS) N PERMANENT ANCHORED POST AS PER SECTION 424.2.17.1.2 00 FBC GFCI RECEPTACLE SHALL BE LOCATED NOT CLOSER THAN 10 FEET NOR MORE THAN 20 FEET FROM WATER'S EDGE. (t POOL LAYOUT & AREA PLAN 1/4" =1' -0" (4) 1/2" HILTi KWIK BOLTS GENERAL NOTES: 1. POOL MECHANICAL EQUIPMENT ANCHORAGE HAS BEEN DESIGNED TO COMPLY WITH F.B.C. SECT. 301.13 2. ALL EQUIPMENT SHALL BE PLACED ON A SINGLE EQUIPMENT SLAB. SEPARATE SLABS ARE NOT PERMITTED. FILTER/ PUMP/ HEATER ANCHORAGE DETAIL PUMP 6" THICK CONCRETE EQUIPMENT PAD FIRST PAGE 6" x 6" CERAMIC HAND HOLD ON MAX. 4' -0" CENTER. POOL WALL POOL CERAMIC HAND HOLD DETAIL t.. i, C2 N LJ L0 S M Q M W N r- C) `r J (0OD Q Z 3 v J z Fes— o Q n Z 4 m o a LL. 0-^ Q- _ Q w w w N Uj N l _ c1 v v w 3 ru 3 N N 0 °-°n Cc Cc'0 S W 0 1 of 2 PROJECT a A i g T8 `d U 0. > a 78 w �$ a o U c7 Z J g :F ., x a 6" x 6" CERAMIC HAND HOLD ON MAX. 4' -0" CENTER. POOL WALL POOL CERAMIC HAND HOLD DETAIL t.. i, C2 N LJ L0 S M Q M W N r- C) `r J (0OD Q Z 3 v J z Fes— o Q n Z 4 m o a LL. 0-^ Q- _ Q w w w N Uj N l _ c1 v v w 3 ru 3 N N 0 °-°n Cc Cc'0 S W 0 1 of 2 PROJECT a A i