Loading...
06-1422-0043 PP WIN 053/ 6" MIN 48X18 FIRE SYSTEM PARTIAL FLOOR PLAN 1/16" S/S CABLE IN 1/2" EMT TO FUSIBLE LINKS USE CORNER PULLEYS AT ALL CHANGE OF DIRECTIONS 17/17 2 ADP NOZZLE R V R ADP 36' 6 BURNER /24' .GRIDDLE WITH CHEESE MELTER 60'X28' XV CONTROL BOX ADP ADP HOOD #1 ADP AIMING POINT {--6" MI I00• O• 00• O'=■ FLAT TOP GRIDDLE 48'X28' BUILDING SECTION 1/2" = 1' -0" KIDDE WHDR -400 FIRE SYSTEM HOOD SIZE: 12 1/16" S/S CABLE IN 1/2" EMT TO REMOTE PULL, USE CORNER PULLEYS AT ALL CHANGE OF DIRECTIONS r------------------------- - - - - -� I 1 I I 1/16" S/S CABLE IN 1/2" EMT TO MECHANICAL GAS VALVE I I USE CORNER PULLEYS AT ALL I I CHANGE OF DIRECTIONS I I KIDDE I I WHM I 400 WHDR -400 CYLINDER I ee j NOTE:REMOTE PULL SHOWN ROTATED I FOR CLARITY, SEE PLAN VIEW FOR --15" SWITCH PANEL I I ACTUAL LOCATION 1 LIGHT, 1 FAN I I I I I I I I I I I REMOTE PULL STATION INSTALLED @ 48' A.F.F. ALONG PATH OF EGRESS PART# 875572 t I 1/2" = 1' -0" jGAS VALVE FIELD LOCATE AND CONNECT , FIRE SYSTEM NOTES 1. NO GALVANIZED PIPE TO BE USED ONLY USE SCHEDULE 40 BLACK IRON STEEL PER NFPA # 17A 2. SYSTEM TO HAVE REMOTE PULL STAION FOR MANUAL MEANS OF ACTUATION AND FUSIBLE LINKS FOR AUTOMATIC MEANS OF ACTUATION PER NFPA 17A 3. SYSTEM TO HAVE HORN /STROBE TO SOUND UPON ACTUATION OF FIRE SUPPRESSION SYSTEM. (INSTALLED AND PROVIDED BY ELECTRICIAN) 4. ALL HOOD PENETRATIONS TO BE WELDED LIQUID TIGHT OR SHALL USE A UL LISTED SEAL PER NFPA #1 7A t:1;1 D KIDDE PARTS LE END SYMBOL DESCRIPTION KIDDE P/N SPECIAL NOTES FOR COVERAGE APPLIANCE NOZZLE GRW, R, F, ADP, (2) ADP Duct DM, LPF, LPR L PLENUM NOZZLE ADP 2 50IN PERIMETER ADP 28" x 28" DUCT NOZZLE 9" radius from midpoint 1 100IN PERIMETER (2) ADP ADP DUCT NOZZLE 42" x 30" 13" min /48" max REMOTE PULL STATION 87- 120050 =001 3 MECHANICAL GAS VALVE '75', 11, 1.25', 1.5', Upright Broiler/ 30.25" X 34" 2', 2.5', 3'. within top 4" of FUSIBLE LINK KIT 87- 120050 -001 IN1111140 ■ 1'. s C ri E D U LE -- NOZZLE APPLICATION COVERAGE LENGTH OF DUCT PER NOZZLE SPECIAL NOTES FOR COVERAGE PQ ' f,p, 1 No. F.P. (2) ADP Duct 100" PERIMETER UNLIMITED 1 (2) ADP nozzles req.d 1 2 1 2 NOZZLE APPLICATION COVERAGE NOZZLE HEIGHT (In inches) SPECIAL NOTES FOR COVERAGE PQ N�s (t No. 1 F.P. ADP Plenum 10' x 4' N/A "V" Bank or Single 1 2 2 NOZZLE APPLICATION COVERAGE UMTA110H FROM SPECIAL NOTES FOR COVERAGE PQINS 1 I 2759 COOKING SURFACE STREET (f,p, No. F.P. R Four Burner Range 28" x 28" 20" min /42" max 9" radius from midpoint 1 2 2 ADP Griddle —Flat Surface 42" x 30" 13" min /48" max on perimeter 1 3 3 ADP Upright Broiler/ 30.25" X 34" n/a within top 4" of 1 1 1 Salamanders broiler compartment TOTAL FLOW POINTS 10 MFG: KIDDE — FENWALL GENERAL NOTES MAXIMUM FLOW POINTS: For piping allowances and balances WHDR125: 4 Flow Points refer to KIDDE — FENWALL Technical WHDR260: 8 Flow Points U L3 0 0 Manual —U.L. File EX3559. WHDR400: 12 Flow Points The System installation shall conform WHDR600: 18 Flow Points to the requirements of NFPA #17A & 96 DUAL WHDR400: 24 Flow Points (manifolded) and all applicable State and Local Codes. 3/8 "0 SCHD. 40 BLACK TO FUSIBLE LINKS AND REMOTE PULL STATION IRON SUPPLY LINE / TO GAS VALVE VENT PLUG f 1/4' ❑D COPPER TUBE eIXV CONTROL WHDR -400 CYLINDER BOX CONTROL PANEL FIRE CABINET HOOD & LIGHT SWITCH FIRE CABINET /FIRE CONTROL PANEL & DOUBLE MICROSWITCH PROVIDED BY HOOD DEPOT. CONTROL PANEL PRE —WIRED TO LIGHT SWITCH, HOOD SWITCH, AND 1 POLE OF FIRE SYSTEM MICROSWITCH. THE CONTROL PANEL IS PRE —WIRED TO SHUTDOWN MUA AND TURN ON EXHAUST IN CASE OF FIRE. ALL OTHER CONNECTIONS ARE TO BE MADE BY OTHERS. THERE IS (1) NO /NC MICROSWITCH AVAILABLE IN THE J —BOX AND (1) SET OF NO /NC SPARE DRY CONTACTS IN CONTROL PANEL (TERM #'9, 10, & 11) FOR OTHER REQUIREMENTS SUCH AS THE SHUTDOWN OF ELECTRIC APPLIANCES AND RECEPTACLES UNDER HOOD, GAS SOLENOID ACTIVATION, FIRE ALARM ACTIVATION, AND ANY OTHER REQUIREMENTS BY NATIONAL, STATE, OR LOCAL AUTHORITIES HAVING JURISICTION. NOTE: IF THERE IS NO BUILDING ALARM IT MAY BE REQUIRED TO PROVIDE A HORN /STROBE TO BE SOUNDED UPON FIRE SYSTEM ACTUATION. � - CONTACT YOUR MUNICIPALITY FOR THERE REQ- UIREMENTS. SYSTEM DETAILS �79_0 iV, ; tl\ ey� •w . • HOOD AND FANS OPERATIONS NOTES 1. SUPPLY AND EXHAUST FANS ARE INTERLOCKED WITH PILOT LIGHT IN KITCHEN AREA. 2. FIRE MODE REQUIRES EXHAUST FAN CONTINUES TO OPERATE AND SUPPLY FAN STOPS. 3. HOOD EXHAUST FANS SHALL OPERATE WHENEVER THE FIRE EXTINGUISHING SYSTEM IS ACTIVATED (EVEN WHEN HOOD SWITCH IS IN OFF POSITION). 4. FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANY ONE OF THE SYSTEM COMMON EXHAUST DUCT FOR MORE THAN ONE HOOD WOULD DEFINE A SINGLE HAZARD AREA EXCEPTION WOULD BE A SECONDARY FIRE SUPPRESSION SYSTEM CONTAINED It IN THE COMMON EXHAUST. 5. ALARM OR INDICATOR INTERCONNECTS WITH FIRE SYSTEM MICROSWITH TO SOUND UPON:. ACTUATION OF FIRE SYSTEM TO BE PROVIDED AND INSTALLED BY OTHERS. (IF REQUIRED); -,,;" 6. PENETRATIONS FOR PIPING AND CONDUITS TOHOOD WILL BE ACCOMPLISHED BY APPRO p UL. DEVICES OR WELDED. .. �` jii:• `t�: {TE'tLPE.EO lI�•, C 0 �` 81 tj v t % r7 - - - - ` � = Ait � ►i�s� �J1}I) � S:S 1st ;gIYI'TTT"I N G PU R .i 'r FIRE - - - - IVLII�IVQ -�jADE TMENT -FI PFO�ECtO ,HA LDBE SUBMIT' FOR = = = W MENT i1EFORE. � FIRE PRO ECTIRQNIF RE ALARM IA I-DADE $ttFOFt RE ELED- DATEINSTALLED OR RE DATE;i r �t�D� O O REVISIONS NUMBER DESCRIPTION 710 S. POWERLINE RD. CHIEF ENGINEER DEERFIELD BEACH, FL. 33442 JOSEPH POTTS, P.E. E —MAIL: HOODDEPOT ©AOL. COM PH,I 800 - 322 -8730 !. Macabi Cigars of South Miami t 5861 Sunset Dr. South Miami, FL 33143 IN —1 764 •0•01ift �•A i SCALE. DRAWN BY. CHECK BY.- DATE.• NOTED JL 3/10/ TITLE.• FIRE SUPPRESSION SYSTEM 1 1 OF �"_ *ei.r xRe+f INK AB EIRE EQUIPMENT . I 2759 19TH STREET POMPANO BEACH, FL IV I Macabi Cigars of South Miami t 5861 Sunset Dr. South Miami, FL 33143 IN —1 764 •0•01ift �•A i SCALE. DRAWN BY. CHECK BY.- DATE.• NOTED JL 3/10/ TITLE.• FIRE SUPPRESSION SYSTEM 1 1 OF �"_ *ei.r xRe+f INK