Loading...
06-1422-002crr i iorr) WITH MIN. OF SHEETMETAL SCREWS EE SIDES 1/4"x6" SELF TAPPING SCREW, TOGGLE BOLT OR THD. ROD ® CORNERS & 12" O.C. MAXIMUM FOR ALL FAN CURBS AND PLATFORMS, ABOVE WILL PROVIDE A CONNECTION OF FAN CURB TO ROOF THAT WILL WITHSTAND WIND LOADS OF 120 MPH WITH A SAFETY FACTOR OF AT LEAST FOUR. 37.75' 11-11\ 32.5'SQ 03/8' BOLTS W/ NUTS AND WASHERS SUPPLY FAN OR 3/8' LAG BOLTS 28' 37.25' 31.5 KSF -15 MIN 2' LONG. " TXB -18 y EXHAUST FAN 2.7 31.5` 28,75' 29 5' 18' 3/8' NUT AND WASHER I 28 5' SQ ON TOP AND BOTTOM f 1 16' OF L BRACKET so _J 3 2 1/4' x 1 3/4 x1/4' 1 'SQ 36.5' 39,SQ 'L' BRACKET I EXHAUST CURB & FAN DETAIL SEE NOTE 2 EF -1 (SEE SCHEDULE) 36' 6 BURNER /24' GRIDDLE WITH CHEESE MELTER 60'X28' FLAT TOP GRIDDLE 48'X28' 0, MI SF— (SEE BUILDING SECTION -- V 1,2" l' -0" _ 2 SUPPLY CURB & FAN DETAIL SEE NOTE 3 EXISTING WOOD EXISTING WOOD TRUSSES, I ALLTHREAD ROD ANCHORED TO HOOD & L BRACKET WITH 03/8' NUTS & WASHERS. 1 1010 TRUSSES. 03/8' BOLTS W/ NUTS AND WASHERS OR 3/8' LAG BOLTS MIN 2' LONG. 2 x 2 x 1/4' ANGLE IRON OR 126A 1 5/8' UNISTRUT I 2 1/4' x 1 3/4 x 1/4' 'L' BRACKET ALLTHREAD ROD ANCHORED TO HOOD I & IRON ANGLE WITH 03/8' NUTS & WASHERS. 1 HOOD ANCHORING DETAIL (N.T.S) FIELD SET SY13 T O'll TO EE STALLED IN AC ANCE 15IiTH la.F.P.A. APpRO�D FOR �I'pING PEr'ATTTTlWG PU (USES SY -DAOE COUNTY FIRE AR-1 T<I�NT EC ?IO ANplOR FIRE ALARM S S�aLL ESC SUBMITTED i O R !�yOaaFZ�l7Cy{1y t�P yy« FT4iE DEPARTMENT 3EFORE -At3Y FtF�E P.SOOREK, NIF L D. ,b. CONTROL OPTIONS WIRED FOR 18'^ X 18' X 6' TYPE 1 _ [HINGED � ELECTRICAL ENCLOSURE � H ❑OD SWITCH LIGHT SWITCH IF PANEL IS REMOTE MOUNTED, DR FIRE MOUNTED AND MOUNTED AND SYSTEM IS FIELD MOUNTED THEN MICRO SWITCH WIRES MUST BE FIELD WIRED. WIRED IN PANEL WIRED IN PANEL NOTE 2, Y OR N = YES Y OR N = YES EXHAUST FAN CONTINUES TO RUN UNDER FIRE CONDITION EVEN WITH ® U GROUND BAR HOOD SWITCH OFF FIELD WIRING m FACTORY WIRING m R1 EF1 SF1 mm m I ® HORN STROBE HS 'PROVIDED AND FIELD 1 1B (1) INSTALLED BY OTHERS m ©m cam J Ct71 FIRE SYTEM BLUE T0(D NC NC MICRO SWITCH FIRE SYSTEM CONTACTS WHEN MICRO SWITCH NO NO SYSTEM IS SET RED m p+ m r0 HOOD svlrcH BRN -FROM HOOD SNITCH 0 ®� PILOT GRDUND HOOD SNITCH V/ PILOT HOT 1200VIPH SEAT INPUT POWER 1 man NEUTRAL 15 AHP BREAKER J ® q) COM SPARE DRY CONTACTS ARE ACTIVATED BY FIRE ❑ SYSTEM MICRO SWITCH t NC AND ARE TO BE USED FOR SHUNT TRIP IQq) NO DEVICE CONTROL OR BUILDING FIRE ALARM WNT 12 -NEUTRAL LIGHT CIRCUIT BLK POWER . 120V IPHASE INPUT P HOT 15 AMP BREAKER VHT (j)s(jD HOOD LIGHTS L L L 100W i0ow V BLK (3) ©� a LIGHT SWITCH VHT ®� SUPPLY CIRCUIT 111 BLK 115V 1 PHASE 30 AMP BREAKER WHT ®� EXHAUST CIRCUIT 111 FAN INPUT HLK 115V 1 PHASE O1D -� 20 AMP BREAKER VHT SUPPLY FAN /1 BLK 115V 1 PHASE ® ( - 1.5 HP 20 AMPS FAN OUTPUT VHT (D®( _ EXHAUST FAN #1 BLK ®� 1 1 BHP 166 AMPS HOOD AND FANS OPERATIONS NOTES 1. SUPPLY AND EXHAUST FANS ARE INTERLOCKED WITH PILOT LIGHT IN KITCHEN AREA. 2. FIRE MODE REQUIRES EXHAUST FAN CONTINUES TO OPERATE AND SUPPLY FAN STOPS. 3. HOOD EXHAUST FANS SHALL OPERATE WHENEVER THE FIRE EXTINGUISHING SYSTEM IS ACTIVATED (EVEN WHEN HOOD SWITCH IS IN OFF POSITION). 4. FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANY ONE OF THE SYSTEM COMMON EXHAUST DUCT FOR MORE THAN ONE HOOD WOULD DEFINE A SINGLE HAZARD AREA EXCEPTION WOULD BE A SECONDARY FIRE SUPPRESSION SYSTEM CONTAINED IN THE COMMON EXHAUST. 5. ALARM OR INDICATOR INTERCONNECTS WITH FIRE SYSTEM MICROSWITH TO SOUND UPON ACTUATION OF FIRE SYSTEM TO BE PROVIDED AND INSTALLED BY OTHERS. (IF REQUIRED),.,,,,,,, 6. PENETRATIONS FOR PIPING AND CONDUITS TOHOOD WILL BE ACCOMPLISHED BY APPR.QvtD,'- UL. DEVICES OR WELDED.' C/� O O 710 S. POWERLINE RD. CHIEF ENGINEER DEERFIELD BEACH, FL. 33442 JOSEPH POTTS, P.E. E —MAIL: HOODDEPOT @AOL. COM PH# 800 - 322 -8730 REVISIONS NUMBER DESCRIPTION DATE J SERVICES 710 S. POWERLINE RD. DEERFIELD BEACH, FL 33442 Macabi Cigars of South Miami IN -1762 5861 Sunset Dr. South Miami, FL 33143 SCALE. • DRAWN BY. CHECK BY. • DATE.• NOTED J.L. 3/10/06 TITLE.• MECHANICAL HOOD SYSTEM 2 OF 3 1, �