Loading...
Res. No. 086-97-10057RESOLUTION NO.86-97-100 57 A RESOLUTION OF THE MAYOR AND CITY COMMISSION OF THE CITY OF SOUTH MIAMI,FLORIDA ,APPROVING THE PURCHASE AND INSTALLATION OF STORM SHUTTERS AT THE PUBLIC WORKS OFFICE BUILDING,AND AUTHORIZING THE CITY MANAGER TO DISBURSE THE SUM OF $1,910.00 FROM ACCOUNT NUMBER 1710-4670,"MAINTENANCE AND REPAIRS OF GROUNDS AND STRUCTURES." WHEREAS,theCity of South MiamiPublic Works Department operations complex consists of field and administrative facilities,and; WHEREAS,the Department's administrative offices house a substantial array of valuable equipment and documents,including personal computers,printers,two-way radio equipment,and important office records,and; WHEREAS,theofficewindowsarenot presently equipped with storm shutters,making theitems within the building vulnerable tothe winds and rain which usually accompany a storm or hurricane,and; WHEREAS,itisinthe City's bestinterestto protect itsassetsaswellasmaintainthe smoothand effective operation of thePublic Works Department. NOW THEREFORE,be it RESOLVED bythe MAYOR AND CITY COMMISSION of the CITY OF SOUTH MIAMI,FLORIDA: Section1.ThePublicWorks Department hasreceivedthefollowingthreebidsfrom qualified manufacturers of storm shutters: Storm Guard Shutter Systems,Inc.$1,910.00 Seaview Industries,Inc.1,950.00 The Jeff Robinson Shutter Company,Inc.3.380.42 Section2.TheCityManagerbe,andisherebyauthorizedtodisbursethesumof $1,910.00 toStormGuardShutterSystems,Inc.forthe purchase andinstallation of galvanizedsteelshuttersforallwindowsofthePublicWorksadministrativeoffices. Manufacturing specificationsandinstallationistoconformtoMetropolitanDade County's Building requirements. Section3.That thisresolutionshallbeeffectiveimmediatelyand after adoption hereof. PASSED AND ADOPTED this 20 th day of May 1997. CITY CLERK READ AND APPROVED AS TO FORM: CITY ATTORNEY COMMISSION VOTE:4-0 Mayor Price:Yea Vice Mayor Robaina:Yea Commissioner Bethel:Yea Commissioner Young:Yea t TO: FROM: CITY OF SOUTH MIAMI INTER-OFFICE MEMORANDUM Mayorand Commission DATE:May20,1997 L.Dennis Whitt City Manager RE:Agenda Item #1 Commission Meeting, May 20,1997 Approval of purchase and installation of hurricane shutters -Public Works office building Theattachedresolutionseeksapprovalfora $1,910.00 expensetopurchaseandinstall hurricaneshuttersinthePublicWorksyardadministrativeofficebuilding.Theshutters willhelp minimize oravertdamagetotheequipment,furnitureandrecordsinsidethe buildingintheevent of atropicalstormorhurricane. PublicWorks obtained three pricequotesforaluminum shutters fromlocalvendors.The quotationsrangedfrom $1,910.00 toapproximately$3,400.00.Theshuttersaretobe installedinaccordancewiththerecentlyrevisedMetropolitanDadeCountyBuildingand Zoning requirements. Acquiring hurricaneshuttersisaprudentmeasuregiventhevalue of theassetsinthe PublicWorksoffice building.Therefore,I recommend thatthepurchaseand installation expense of $1,750.00 beapproved. Attachments APR-29-97 9l:l9 PM ERNESTO LUEGE BP 83773S4 305 2T3 6123 SOLO TO ADDRESS CITY JOB ADDRFSS_ BUILDING /COMPLEX NAME. .con?w We propose to provide the follow THE JEFF ROBIXSOX SHUTTER COHPAHY.IHC. Tho First Name In Storm Protection 7592-94 NW 74th Avenue •Miami,Florida 33166 Phone:(305)884-7066Dade•(954)525-4980 Broward .SALES AGREEMENT Page 1 of _L ^Xiil>L.OF^iO^H--^^Ml date M--Tzyj-^ HlAHi STATE ftA ZIP ^3>Lqg;_APT.NO .OAH £MUNICIPALITY T3AD^C^O ESTIMATE VALIDFOR THIRTY (30)DAYS peRH IT5 A**5 •^^TA-LLrVnoO ^f *-*,"IVvVT IS m*J&s&>Auj**-|-Ooht P^crts H«Ae ""^PRINT NAMF -v Dale; O'dci Swtuttf to ir-o Approvalof Man*!*"*** RVlK^HASfM MAY WITHOLD RETAINAGE OF 10%OT TIC CONTRACT I'HICE UNTIL FINAL IN5PEC IIIOINl^^^.fj^lJP^^^w^^Stm1FAIllJRCSCA'JStO BY PUHUHAStH AS IO iHt-FINAI INSPFCTION On APTROVAL RETAINAfiC TOBEPAI0 »N TULL WITHIN 3 BUSINESS PAY*u*"*m. |INSPECTION A^PHOVAL.rWhite-Original File Copy;Yellow Customer Copy:Pink -Accounting;Goldcnrod -Sales Representative copy 1 APR-29-97 01:18 PM ERNEST©LUEGE BP 8377354 305 273 6123 P.,01 THE JEFF ROBINSON SHUTTER COMPANY 7592 N.W.74 Ave.Miami,FL 33166 Dade 305/884-7066 Broward305/525-4980 Nationwide 1-800-642-3057 Fax305/863-8983 DATE:-fUGS,.Ac'IPi-Vt TO:feOO^Qf&IA TTQttJUS COMPANY:O VIM Of SO-MlAh>H FAX*....JkilMJfl re:HORtMOMg etturmrys COM •A^.R.ct M.~HA.t4fc.c4eR, Placed By:C^-^y N°°f PaS«^Including Cover Sheet IF THERE IS ANY PROBLEM IN THIS TRANSMISSION,PLEASE CONTACT THE SENDER. IF YOU DO NOT CONTACT US WITHIN 15 MINUTES,WE WILL ASSUME THAT YOU HAVE RECEIVED THE PAGES SATISFACTORILY. COMMENTS:*+><>]'A£j**~cXJKL l^ef.WOr^C:..JM-kl&K&rioA Of- ^\^7TUK2-0frS X M-\eOClpSiQQ ..cDOK.?W^$^_te_JteQg$TeO, x Hard copywill follow.Q Hard copy willnot follow. layout*-Cpfic£ IMPORTANT MESSAGE Tills transmittal Is Intended ontv for the use of the Individual or entity to which It Is artdrmctL apd may conLaJn Information that Is privileged*confidential and exempt from dl?clo<»rp ijndT applicable law.If ihc reader or this* transmittal is not the intended recipient,you are hereby notified that any dissemination,distribution or copying of this communication is strictly prohibited.If you have received this communication in error,please notify us immcdiatly by telephone,and return ihc original iransmiual to us ai the address below >ia the United Slates Postal Sen ice.Thank You. 1 ,APR-29-97 01:20 PM ERNESTO LUEGE BP 8377354 305 2T3 6123 Eh N f^^ 1- 0,1 B* wEr*&> 9 5 c F* CO £ o -5 // P.03 *J (ft "Tit >- 7"- 7 APR-21-ST 10:48 AM OFFICE DEPOT 3880539 P.02 PROPERTY OWNER PURCHASER AGENT <»HOT property ownrn, JOB SITE ADDRESS MAILING ADDnFf,r, (irwrrtHtNTi SALES CONTRACT Miss N*UtTftltt.IMC COC 055121 3750N.W.46lhStreet,Miami.FL 33142 Dade Phone (305)633-9650 Wats1•800-2828606 Fax:(306)634-9060 CONTRACT NO OATt HEdDCNCf rMM>Ht)Ng BUSINESSTELEPHONE OTMPA fPl PP*«wr—lC£Tuu*icn cnrli nm ^r m/>b,»*a*-..OTMER TELEPHONE (ESTIMATED FROM DATE OP RECEIPT OP PERMIT) TTWs contract .*subject to covenants and conditions on the reverse Side hereof "Thi*contract Is the comoieto uareomont b^^TTuriw.*«^i ^,.™ggPJam,continaencle.,P.,ymonts.material,or wn*,h-h,..^,T p^e»c£tt eT^ss^ OMEMMC T *-''''"",mm ^——————OPfNMG NO.WIOTM paoaucT STWPf COLOA 1O0R NUMBER m"A6o?c/2o (2) J3> (5)c&>*:rty* COLOR *CoZ t^f DESCRIPTION •INSTRUCTIONS far'T*"4 StoO'TirXAJ'sri 1Q&,'3-L—y SfAJtCJ <6) (7) (8)*Ffi*^W (10) (11) (12) /*-*/yC^O^^^ULC 6LJ-f4<?ofiX*/<j +A\?+a.c*OtteR (13) (14) (15) 06) cno* (17) (18) (19) (20) (21) (22) (23) (24)^_ (SEE ADDITIONAL PAGC(S)OFTHIS CONTRACT TORSITEPLAN Settershall have fifteen (15)daysfromthedateofthiscontracttoreviewthetermsand cancel •«such reviewisnotacceptabletoits Englneerino Review Department.In the eventofcancellationby Setter anydeposit wiu berefunded. "BUYERS RIGHT TO CANCEL"This isa home solicitation sale,andifyoudo not want the 9000s or services,you may cancel this agreement by providing written noticetothesellerin person,bytelegram,orby mail.This noticemust indicate thatyoudonotwantthegoodsor services andmustbedelivered or postmarkedbeforemidnightofthethird business dayafteryou sign this agreement If youcancelthisagreement,thesellermaynotkeepallorany part ol any cash riownpayment. Executed in tour copies,one copy ol which was delivered to.and receipt is hereby acknowledged by buyer,this day of 19 7 ) Purchaser V s?(Seal) Purchaser /(Seal) WHITE&CANARY-OfficeCopies PINK -CustomerCopy ANDADDITIONALINFORMATION) SALES PRICE $>/f^ SALES TAX PERMIT PEE SURVEY FEE TOTAL CONTRACT LESS:DEPOSIT "BALANCE DUE J£OO s /9fO.OG /9fQ.2>*> •Unlessagreedelsewhere herein,upon compfation of instailattori.thePurchasershadpayto SeaView anamount equaltoninety(90%)percentofthetotalcontractprice minusany deposn previously paid.The remaining ten (10%) percent shall be ^w immediatelyuponreceipt of "Final 'from the appropriate municipality. Salesman -7/frto?AMjrrf 1 I (j)STDRM PANEL scale •r •r-tr VARIES*&C3'MAX (OrlUMAL LUCATIl*" !! J "5U. ©*h#HEADER scale .r-r-c zzsr , 1 «s«- RjOO* i' 'U'HEADER SCALE •V -!'-0* L-222J 0 OPTIONAL ANGLE SCALE •T •I'-8* mis shuttcr systemis designed in accordance withthe south FLORIDA BUILDING QBE.\TM OITIOM.AND 1994 WWW COUNTY QITION. ©ANGLE ©STUDDED ANGLE QVINGNUT ©16 GAGE STEEL TUBE 2.POSITIVE AND NEGATIVE DESIOt PRESSURE CALCULATIONS SMALLBE PERFORMEDINACCORDANCE VITH ASCE 7-«'MINIMUM DC ICMLOADS FDR BUILDINGS AMDOTHER STRUCTURES*. 3.STORMPANELSSMALLBE 3Q32-M3S ALUMINUM ALLOT..063'THICK,VITM A MIN.Fy (BEFOREROLLING)OF 24 KSl.ALUMINUM ECTRUSIOMS SMALL BE 6063-Tt,U.O.N. 4.PRODUCT MARKINGS SHALLBE VITHIN «•OFCMCENDOFTICPANELVITH A MIN.OFONENARKINGPER PANEL.ANDSHALL BE LABELEDAS FOLLOW, SEAVIEV INDUSTRIES,INC. MIAMI,R. DAK COUNTYPROD.APPRD. 5.ALLBOLTSAND VASMERS SHALLBE GALVANIZES OR STAINLESS STEEL VITH A MINIMUM Fy-33 KSI. 6.ALL PANELS SHALLBE FASTENED AT OVERLAPS ATNIDSPAN V/1/+-20 K 9-1/2' SIDEWALK BOLTS V/DIECASTALUMINUMVASHERED VINGMJTS OR JACKMUTSi UTILIZING A |*x I's It GA STEEL TUBE AT NIBSPAN.(SEETYPICALELEVATION).PORPANELS SPANS LESS THAN 33'OVERLAP FASTENERS ANDTUBEARENOT REQUIRED. 7.MATERIAL SPECIFICATIONS NOTEDHEREIN ARC THEMANUFACTURER'S REPRESENTATION OF MATERIALS TOBE USES INPRODUCT TESTING. 0.THE DETAILS AND SPECIFICATIONS SHOWNHEREINREPRESENTTHE PRODUCTSPROPOSEDFOR IMPACT,CYCLIC ANDUNIFORM STATIC AIR PRESSURE TESTING INCONFORMANCE VITM DADE COUNTYPROTOCOLS PA 201,202.AND 203 VITH DESIGN LOADSAS FOLLOWS' -POSITIVE DESIGN LOAD C8 PSF -NEGATIVE BESIGN LOAD 72 PSF DESIGN BASEDONCTC TEST REPORT No.95-006. 9.AWARNINGNOTESHALLBE PERMANATELr PLACEDONEITHERTHE SILL OTTHE SHUTTERSOR OH EACHPANEL ADVISING THE HOME OWNEROR TENNAMT OFTHE FOLLOWING. -A STEEL REINFORCINGBAR I BOLTS MUSTBE PLACE!ACROSSALL PANELS AT NIDSPAN AND ARC RESUIRO INORDERTOOFFERHURRICANE PROTECTION. 10.TOPLBOTTOM DETAILS SHOWNMAYBEINTERCHANGEDAS FIELD CONDITIONS DICTATE.PANELSMATBE MOUNTED HORIZONTALLY WHERE APPLICABLE. 11.AWARNINGNOTESMALLBEPERMANENTLYPLACESONEITHERTHE SILL OF THESHUTTERSORONEACH PaMEL ADVISING THE HOME OWNERORTENANT THATTHESTORMPANELS WILL NOTOFFERHURRICANE PROTECTION UNLESS ALL REINFORCING BOLTSAND STEEL TUBEAREPROPERLY INSTALLED. tCM£•r•!'-o-JCALE 1 V •r-o*SCALE •WW SIZESCALE i HALFSIZE WIDTH UNLIMITED !•x !'TUBEt rASTEMERS GET PLANVTEV1NOTE 6> TYPICAL ELEVATION •SHEAR FASTENER - -1 24*DC- y-^y OVERLAP FASTENERS TTP.(SEC NOTE•«> ANGLECLOSURE PIECE* I'i I'«.139'MIN.TO V u3*u .083'MAX. PLAN VIEV SCALE.1-1/2*•l'-C L V x T x16GASTEEL TUBE TTP. SEC NOTE6t TYPICAL ELEVATION. THROUGHBOTTOMTRACK I*nV m .123'NIN.TO 8'*S'«.125'MAX. SHEAR FASTENED 12-OC APPROVED AS COMPLYING WITH THE SOUTH FLORIDA BUILDING CODEDATE_3lilKg>3£ PRODUCT6 CONTROL DIVSUN O BUILDING CODEJJOMPUANC^OFFICE,. ACCEPTANCE I CODE COMPLIANCE OFFICE^. ltd *§u§? ft** Z §-36 U z C/) u 3 yon- »*?a sel;^nx <C UJ O VI s M •> O |m u4 1 ln 111 vjL»Qfiy» TRFUSSMAL/tNCP- k^rrw (&T 95-132 •*w»t I or 3 © EXISTINGSTRUCTURE !/««»RAWLCAUC-B4ANCHDR M'OtV/7/TDOOMONT MCOME,ORBLOCKV/!/£• &S.MAOMBCBOLTftVASMER DIRECTMOUNTDETAIL SCALEi3*-I*-C L CXISYTNCSTRUCTURE '|/4-fBNAOOC BOLT*WB4GMUT If'U J5 • 1 -a> i MIIE:THISDETAILMAYKUSED ATTOPORBOTTOMGFPANELS. VALLMDUNTDETAIL ® SCALE•3*-l'-C* ANCHDRSCHEDULE FASTENERSPACINGREQUIRED(INCHESD.C.) EXISTING STRUCTURECONCRETEHOLLOWBLOCKWOODFRAMING ANCHOR DESCRIPTION 1/4'PITVTAPCONANCHDR V/1-1/4'MIN.EMBEDMENT 1/4'PITVTAPCONANCHOR V/1-1/4'MIN.EMBEDMENT ONE1/4*0wTjQDLAGSCREW W/1-7/8'MIN.EMBEDMENT EDGE DISTANCE2'3'2*3* 3/4» (SEEANCHORNOTENo.2> FASTENER SPACING^^ir11'^^^y12*5'^^^y^6*6'^^J^^^ <* ANCHORNOTES' MINIMUMEMBEDMENTANDEDGEDISTANCEEXCLUDESWALL FINISHORSTUCCO. WHERELAGSCREWSFASTENTDNARROWFACEOFSTUD FRAMING,FASTENERSHALLBELOCATEDINCENTEROF WOODSTUD. ANCHORSSHALLBEINSTALLEDINACCORDANCEWITH MANUFACTURERSRECOMMENDATIONS. APPROVEDASCOMPLYINGWITHTHE SOUTHFLORIDABUILDINGCODE BYf4/tfM4tfAr-flPU<*- PRODUCrCONTROLDIVISIONQ BUILDINGCODEpWiPJ-lAjJCE^OFFICj. ACCEPTANCENO."*~ irriuc US # o z§ »> tn-6---~ia- h- < uS* Sss $^S-MMN « S>h.n > Ulptufn r*ag&- LJzx-W ZMS CO u IDon < u to iirpi VJBCEVttJ PfiOFESSUSMt^n PE0010933^. iQc 95-132 METROPOLITAN DADE COUNTY.FLORIDA METRO-DADE R.AGLER BOlLDING BUILDING COOE COMPLIANCE OFFICE SUITE 1603 METRO-OADE FLAGLER BUILDING MO WEST FLAGLER STREET MIAMI.FLORIDA 33130-1563 PRODUCT CONTROL NOTICE OF ACCEPTANCE taw 375.2901 _FAX (305)375-2908 Seaview Industries,Inc.DO„,,_^^^^~.~'PRODUCT CONTROL SECTION 3750 N.W.46 Street (305)375-2902 Vf •n M1 4-1 FAX (305)372«39MiamiFL33142 Your application forProductApprovalof: .063 "Aluminum Storm Panels under Chapter 8 of the Metropolitan DadeCountyCode governing theuse of AlternateMaterialsand Types of Construction,and completely described in the plans,specifications and calculations as submitted by: Applicant,alongwithDrawingNo.95-132,Sheets I thru3 of3.(Forlisting,seeSection8 ofthis Notice ofAcceptance) hasbeenrecommendedforacceptancebytheBuildingCodeComplianceofficetobeusedinDade County,Floridaunderthespecificconditionssetforthonpages2et.seq.andtheStandardConditions on page 3. This approval shall not be valid after the expiration date stated below.The Office of Code Compliance reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing.Ifthis product or material fails to perform inthe approved manner,theCode Compliance Office may revoke,modify,or suspend the use of such product or material immediately.The applicant shall re-evaluate this product or material should any ammendments to the South Florida Building Code be enacted affecting this product or material.The Building Code Compliance Office reserves the the right to revoke this approval,ifit is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code.The expense of suchtestingwillbeincurredbythemanufacturer. Acceptance No.:95-0406.05 (Revises No.:94-0928.05) Expires:02/16/98 ^Raui Rodhguez ProductControlSupervisor THIS IS THE COVERSHEET,SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application tor Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee tobe used in Dade County,Florida under the conditions set forth above. Director BuildingCodeComplianceDept Approved:06/15/95 -1-Metropolitan DadeCounty Seaview Industries.Inc.ACCEPTANCE NO.:3j-0*?-,»;>- APPROVED :JM 15 1995. EXPIRES :Feb.16.1998 NOTICE OF ACCFPTANCE:SPECIFIC CONDITIONS 4.1.2 Buildout Mount The panels are secured tothe "U"Header (Part 3)atthe head,fastened using l/4"-20 machine bolt &nut spaced @ 12"o.c,to a2 1/4"x5 1/4"x 1/8"aluminum Angle (Part 5)used to provide the buildout,and whichis anchored tothe wall.This condition is repeated atthesill except that a 2"x2"x 1/8"Studded Angle (Part6)isusedinlieu of the"h"header.The 21/4"x5 l/4M x 1/8" angles are then anchored tothewall using thetension anchors asshownonDwg.No.95-132, Sheet2 of 3,Sections D and G "Build-Out Mount",bearing the Dade County Product Control approval stamp. 4.1.3 Ceiling/Inside Mount The panels are securedinside atoptrack"U"Headeratthehead,which is anchored totheinside ofthe opening;and fastened atthe sill,tothe 2"x2"x 1/8"continuous aluminum Studded Angle (Part6),using l/4"-20 studswithwashered wingnut spacedat6"o.c,which isanchoredtoa concrete slab or bulkhead,as shown on Dwg.No.95-132,Sheet2 of 3,Section C "Ceiling/Inside Mount",bearingtheDadeCounty Product Controlapprovalstamp. 4.1.4 Any combination of the above, 4.2 Anchorage of the aluminum angles shall beto concrete,masonry and/or wood framing and shall consist of onlythe anchors,embedmentand spacing specifiedon Drawing No.95-132,Sheets I, 2 and 3 of 3.Substitution of anchor typeor indicated embedment is unacceptable and requires to be engineered separately.Fasteners musthavetheirownNotice of Acceptance. 4.3Permanentsetfastenercomponents,embeddedanchorbolts,threadedconesormetalshields,not inuse,mustbe protected against corrosion,contamination and damage at all time. 5.IDENTIFICATION 5.1 Each unit shall bear a permanent label withthe manufacturer's name or logo,city,state and following statement:"Dade County Product Control Approved". 5.2 Warning Note shall be permanently stamped in each panel advising thehome owner or tenant that storm panels longer than 33"willnotoffer hurricane protection unless a 1"x 1"x 16 ga.steel reinforcing bar and l/4"-20x3 1/2"sidewalk bolts and washered wingnuts spaced at 12"o.c.are properly installed at midspan,ontheexteriorandacrossthe whole width of theshutter. 6.USE 6.1 Application for building permit shall be accompanied bytwo copies of the following: 6.1.1ThisNotice of Acceptance. 6.1.2 Completely dimensioned drawing showing size and location,including height above grade,of openings to receive shutters;meanroof height,length and width of building. 6.1.3 Duplicate prints of approved drawings No.95-132,Sheets 1,2 and 3 of 3,bearing the approvalstamp,Notice of AcceptancenumberanddatebyDadeCounty Product Control Section,clearlymarkedtoshowthecomponentsselected for theproposed installation. 6.2 The Building Official shall ensure the adequacy of shutter tomeetthe pressure requirement of the opening in which itistobe installed. 6.3 This revision supersedes Notice of Acceptance No.94-0928.05 dated 02/16/95. Manuel Perez,P.E.(j Plans Examiner II Product Control Division j# -2a-I Seaview Industries.Inc.ACCEPTANCE NC.95-0-196.05 ' APPROVED :J0N 15 1995 EXPIRES :Feb.16.1998 NOTICE OF ACCEPTANCE;standard conditions 1.Extension of Acceptance maybe considered afteranew application has been filed and the supporting data,testreportnoolderthanten (10)years,havebeen re-evaluated. All reports of re-testing shall bear the seal,signature anddate of anengineer registered inthe State of Florida. 2.Any revision or change in the materials,use,or manufacture of the product or process shall automatically be cause for termination,unless prior approval is granted for revisions or change. 3.Any unsatisfactory performance of this product or process ora change in Code provisions shall be ground for re-evaluation. 4.This acceptance shall not be used as an endorsement of any product for sales or advertising purposes. 5.The Notice of Acceptance number preceded by the words Dade County,Florida,and followed by theexpirationdatemaybe displayed in advertising literature.Ifany portion of theNotice of Acceptance is displayed,thenitshallbedoneinits entirety. 6.A copy of this approval as well as approved drawings and other documents shall be provided to the permit applicant bythe manufacturer orhis distributors and shall be available for inspection at thejobsiteatalltime.The prints need notbe re-sealed bythe engineer. 7.Failure to comply with Standard Conditions shall be cause for termination of Approval. -j - ManuelPerez,P.E.(J Plans Examiner II Product ControlDivision *I 1660 West 33rd Place Hialeah,Florida 33012 PURCHASER- PROPOSAL /CONTRACT Manufactured by Florida Metal Industries,Inc. Dade (305)828-2282 Fax (305)828-2182 Toll Free 1-800-675-4886 PROPOSAL DATE:Hlidqg Job Address:HQir ^0 -rfouuu Folio #: S&(t^Mailing Address City:hAU Customer Phone Numbers: HOME:() Soi/jU (Tiierm WORK:( .^ST )C6J n^O FAX:( Zip: LIMITED WARRANTY SellerwarrantsKernssoldpursuanttothisContract againstdefectsinaluminummaterialforaperiodof ten (10)years from the order date.Steel material is warranted for one (1)year.Rustisnotincludedin thelimitedwarrantyforsteelmaterial.act 3W This contracfissubjecttoTo^ ___jemisJ^ondi^payments,materials or work shall be expected ofeither party except as expressly provitje'd for herein. """"*?<^*V<-^^0^^^^i.DESCRIPTION We are pleased toprovide the following work:.,:• TBlMrtwm fwKim 7-pnoJ % *Vltt>C tesvvrbu B\Ve3 1st FLOOR gj 2nd FLOOR • D Other _ Total Cash Price: Sales Tax Engineering. Permit Survey:_ Total Contract. Deposit Balance Due: m K-mc imA \W W W Noticeto Buyer 1.Donotsignthiscontract until you readitorifit containsanyblankspaces. 2.You are entitled toanexact copy ofthecon tractyousign. 3.Balance duemeansupon delivery ofmaterial. "T" i/ O) 0) T D c CO <D 5 r D r This Contract shall notbe binding until approved and countersigned byan officer ofthe Seller other than.the salesman. Approved and Countersigned: Florida Metal Industries,Inc (SELLER) Executed in three copies,one copy of which was delivered to,and receipt is hereby acknowledge by buyer,this. which shall be henceforth known as the Order Date. Youthebuyermaycancelthistransactionatanytime prior to midnight ofthethird business dayafter the dateofthis transaction.Purchaser Salesman Jfrdflfr Purchaser .day of.J9_ (Seal), (Seal) flPR-16-97 WED 10:20 FLfl METAL IND 05 82S 2182 FlomdA MetaI hdusTRiEs,Inc. 1660 W.33rd Place Hialeah,FL 33012 phone:(305)828-2282,fax:(305)828-2182 FAX COVER SHEET DATE:y-/&zH. <^S-e> ai,/-£7f/ // yfULoU^^ COMMENTS: Manufacturers of panel,accordion and roll-up storm shutter systems for commercial and residential applications featuring: 3tom XSniatii mm 111 p••ii•1111 ni 1 mm IF YOU HAVE RECEIVED THIS FAX IN ERROR,PLEASE NOTIFY THE SENDER AT THE PHONE NUMBER ABOVE.THANK YOU. P.01 7 APR-16-9T WED 10:21 FLA METAL IND 05 828 2182 P.©2 METRO-PADEM METROPOLITAN OAOE COUNTY,FLORIDA Wmm\\tm\mmm\\W METRO-DADE FLAGLER BUILDING•^^^^-f ^ BUILDING COOE COMPLIANCE OFFICE SUITE 1603 METRO OADE FLAGLER BUILDING 140 WEST FLAGLER STREET PRODUCT CONTROL NOTICE OF ACCEPTANCE miami.«-orida 33130.ish (305)375-2901 Florida Metal Industries,Inc.FA*P05>375-2908 4***«r -*-*«.INTERNET:mdccOl ©shadow.nei 1660 W,33 Place Hialeah FL 33012 product control section (305)375-2902 FAX (305)372-6339 Your application forProductApprovalof: "Storm Guard"Aluminum Storm Panels under Chapter 8 ofthe Metropolitan Dade County Code governing theuse ofAlternate Materials and Types ofConstruction,andcompletely described intheplans,specifications and calculations as submitted by: Applicant,along with Florida Metal Industries,Inc.Drawing No.96-67\sheets I fit rough 7of 7dated 09/16/96,signed byWalterA.TillitJr..P.E.(Forlisting,seeSection8 ofthis Notice ofAcceptance) has been recommended for acceptance by the Building Code Compliance officetobeusedin Dade County,Florida under thespecific conditions set forth on pages 2et.seq.and the Standard Conditions onpage3. This approval shall notbe valid after the expiration date stated below.The Office ofCode Compliance reserves the right tosecurethis product or material at anytime from a jobsite or manufacturer's plant for quality control testing.Ifthis product or material fails to perform in the approved manner,the Code Compliance Officemay revoke,modify,or suspend the use of such product or material immediately.The applicant shall re-evaluate this product or material should any ammendments totheSouth Florida Building Code be enacted affecting this product or material.The Building Code Compliance Office reserves the the right to revoke this approval,if itis determined bythe Building Code Compliance Office that this product or material fails tomeetthe requirements of the South Florida Building Code.The expense of such testing willbe incurred bythe manufacturer. Acceptance No.;96-0S13.02 (Revises No-:95-0821.07) Expircs:08/lS/97 •Product Control Supervisor THfS IS THE COVERSHEET,SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee tobe used in Dade County,Florida under the conditions setforthabove. Building Code Compliance Dcpt Approved:11/07/96 -1-MetropolitanDadeCounty ^APR-lfe-^T MED 10:22 FLA METAL IND 05 828 2182 P.03 .Florida Metal Industries ACCEPTANCE NO.:9(HV>n(P APPROVED :WW 0 7 '996 EXPIRES :August!S 1997 NOTICE OP ACCEPTANCE:SPECIFIC CONDITIONS 1.DESCRIPTION 1.1 This approves an aluminum storm panel designed to comply with the South Florida Building Code,1994 Edition for Dade County,for the locations where the pressure requirements as determined by ASCE 7-88 "Minimum Design Loads for Buildings andOther Structures",donot exceedthe Design Pressure Rating values inSection7 and within the limitations contained in Section 3. 2.MATERIAL CHARACTERISTICS 2.1.Thestormpanelsshallbe constructed as indicated onApproved Drawing No.96*67,Sheets1 through 7 of 7,using 0.063"thick aluminum,5052-H32 alloy.; 2.2 Panels arerolledformed,havea nominal width of 12.00"andatotalwidth of 15.50",forming 2" deepribs. 2.3 Aluminumcomponentsshallbe alloys 6063-T6 except"h"header,V header,2"x2"x 1/8" studdedanglesarealuminumalloy 6063-T5. 2.4 Tested specimen: Dimensions:40"wide x70"long overall 38 1/2"widex99"long overall 39"wide x 99"longoverall 40"widex 102"long overall 40"wide x 105"longoverall 38 1/2"widex 107 9/16"longoverall 381/2"widex 144 1/2"longoverall 393/8"wide x107 1/8"longoverall 3.LIMITATIONS ""** 3.1 The design will be dependent on the maximum panel span (height)of: 3.1.1 8'-IO 1/4"or 106.25"for wail mount,attachedtowall using an"h"header attop;a studdedangleandwingnutatbottom(seeSection1 of Drawing.No.96-67). 3.1.2 8'-9"or 105"forwallmount,attached towallwith studded angleandwingnuttop and bottom(seeSection2 of Drawing.No.96-67). 3.1.3 12'or 144"forwallmount,attached towallwith studded angleandwingnuttop and bottom,and a l"x 1"x 16 gauge steel lube reinforcement across the whole widthat midspan (sec Section 2A of Drawing.No.96-67). 3.1.4 8,-l0 1/8"orl06.19.S''for wall mount,attached to wall stud plate and wing nut top and bottom(see Section 3 of Drawing.No.96-67). 3.1.5 T-7mnnr 91 1/2"for inside mount,attached to wall using a "U"header at top;a studded angle and wingnutatbottom,and a 1/8"x1 1/2"alum,strap reinforcement across the whole widthspacedat24"o.c.(seeSection4 of Drawing.No.96-67). HetmyTl.Makar,P.E.,Plans Examiner Product Control Division -2- APR-16-9T MED 10:23 FLfl METAL IND Florida IVfrfaf Industries 05 828 2182 ACCEPTANCE NO. APPROVED EXPIRES P.04 —2kftiL3jj2_ NOV 07 199ff August IS.IQQ7 NOTICE OF ACCEPTANCE;SPECIFIC CONDITIONS 3.1.6 8'-6"or 102"for built-out mount,attached towallusinga"U"headerattop;astudded angleandwingnutatbottom;both attached toa2"x5"x 1/8"alum,angle,anda1"x 1"x16 gaugesteeltubereinforcementacrossthewholewidthat midspan(seeSection5 of Drawing.No. 96-67). 3.1.7 S,-10"or70"for wallmount (direct mount),attached towall direct attop and bottom(see Section6 of Drawing.No.96-67). 3-1.8 8'-3"or 99"forwall mount (directmount),attached towalldirectattopandbottom,and a 1"x 1"x16gaugesteeltubereinforcementacrossthewholewidthatmidspan(seeSection6A of Drawing.No.96-67). 3.2 Minimum separation to cristing f lass to protect shallbe: Reinforcement required Panel span up to: Min.Separation toglass Design Load Ref.Drawing Section Number 3.2.1 3.2.2 3.2.3 3.2.4 3.2.5 3.2.6 3.2.7 3.2.8 None 8'-10 1/4"2 11/16"+58.0,-76.0 psf 1 None 8'-9"2 1/2"+72.0.-72.0 psf 2 l"x INx 16 gauge Steel Tube @ panel midspan l2'-0"2 3/4"+57.2.-75.7 psf 2A None 8'-10 1/8"2 7/8"+52.0.-56.0 psf 3 Alum.Strap@ 24"o.c.7-7 1/2"2"+50.0.-72.0 psf 4 Px Px 16 gaugeSteel Tube @panelmidspan 8'-6"2 1/2"+72.0,-72.0 psf 5 None 5'-10"2 7/8"+58.0.-76.0 psf 6 Px l"x 16 gaugeSteel Tube @panel mid span|8'-3"2 1/2" - +72.0,-72.0 psf 6A 3.3 Maximum clearance between fop of panelandinsideofheadershall be 1/4". 3.4 Reinforcement: 3,4.1 Panels shall be reinforced as required either at midspan by aPx P x 16 gauge steel tube or @ 24M o.c.bya 1.50M x 1/8"aluminum strap depending on the separation from glass required and mounting conditions as shown on Section 3.2 and "Maximum Design Pressure Rating W (psf) and corresponding maximum span L (ft.)Schedule"shown on Sheet 7of7,Drawing.No.96-67. Helmy A.Makar,P.E.,PPlans Examiner Product Control Division 2a- APR-16-97 WED 18:24 FLA METAL IMP 05 828 2182 P.©5 mxM&Msi2UBd^ACCEPTANCE NO,96-05H 07 . APPROVED t :m 0 7 1996 EXPIRES :August IS.1997 NOTICE OF ACCPPTAMrF,SPFCIFIC CONDITIONS 4.INSTALLATION 4.1 Thft panels shall he installed only in thp followinp condition; 4.1.1 Wall Mount The panels are secured to an "h"header or angle or stud plate at the head and to a 2"x 2"x 1/8" alum,studded angle or stud plate,using l/4"0-2O x 3/4"studs w/wing nut and washer spaced at 12"o.c.at the sill,which are anchored to the wall,using the tension anchors as shown on Sections 1,2,2A and 3,"Wall Mounts"Sheet 1 of7,of Drawing.No.96-67.bearing the Dade County Product Control approvalstamp. i 4.1.2 Inside Mount The panels are secured inside a top track "U"Ceiling Mount Header at the head,which is anchored tothe inside ofthe concrete lintel opening;and fastened tothe2"x2"x 1/8"continuous studded aluminum Base Angleatthe sill,using l/4"0-2O machine bolt,wingnut and washer at 12"o.c. which isanchoredtoaconcreteslaborbulkheadas shown on Section 4,"Ceiling &Floor Mount"Sheet2 of 7,of Drawing.No.96-67.bearing the Dade County Product Control approval stamp. 4.1.3 Buildout Mount The panels are secured toa "U"header atthe head,which is anchored usingl/4"0-2Ox 1/2" machine bolt &nut @ 6"o.c.to the long leg ofa 2"x 3".4"or 5"x 1/8"aluminum angle used (o provide the buildout,which is anchored to the wall;and at the sill toa 2"x 2"x 1/8"alum,studded angle,using l/4"0-2O x 3/4"studs w/wing nut and washer spaced at 12"o.c,which is also anchored using l/4"0-2O x 1/2"machine bolt &nut@ 6"o.c.tothe long leg ofa 2"x 3".4"or 5" x 1/8"aluminum angle.The build-out angles are anchored tothe wall as shown on Section 5. Sheet3 of 7,of Drawing.No.96-67,bearing the Dade County Product Control approval stamp. 4.1.4 Direct Mount The panels are secured directly to the wall at head and sill using 1/4"x 7/8"Rawl Calk-in or Star Tampin embedded into concrete or masonry,spaced at 12"o.c,as shown on Sections 6 and 6A "Direct Mounts",Sheet 3of 7,of Drawing.No.96-67,bearing the Dade County Product Control approval stamp. 4.1.5 Wall Mount on Wood Framing This installation is similar to the build-out,wall mount &inside mount conditions but anchored to a wooden substrate using the tension wood anchors as shown on Sections A,B,C,D &E "Installation Detail",Sheets S &6of 7,of Drawing.No.96-67,bearing the Dade County Product Controlapprovalstamp. Helmy A.Makar.P.E..Plans Examiner Product Control Division -2b- 1 APR-16-97 NED 18:26 FLA METAL IMP 05 828 2182 P.©6 j^^^ACCEPTANCE NO.:96-03 H.TO - APPROVED ,:lffl 0 7 1996 EXPIRES :August 15,1997 NOTICE OF ACCEPTA"™^SPE^mC CONDITIONS 4.2 Anchorage ofthe aluminum angles shall be to concrete,masonry and/or wood framing and shall consist ofonly the anchors,embedment and spacing specified on Drawing No.96-67,Sheets 1 through 7of 7.Substitution ofanchor type or indicated embedment is unacceptable and requires tobe engineered separately.Fasteners must have their own Notice of Acceptance. 4.3 Permanent set fastener components,embedded anchor bolts,threaded cones or metal shields,not in use,must be protected against corrosion,contamination and damage atalt time. 5.IDENTIFICATION 5.1 Each panel shall bear a permanent label with the manufacturer's name or,logo,city,state and following statement:"Dade County Product Control Approved". 5.2 Each opening or,inthecaseof direct mounted panels with no header and sill,each panel shall have alegible permanent marking instructing owneror tenant tosecure panels atlapjoints with applicable reinforcing:1/8"x1 1/2"aluminum straps OR 1"x I"x 16 gauge steel tube,across the wholewidth of theopeningduring periods of Hurricane warning. 6.USE 6.1 Application for building permit shall be accompanied by two copies ofthe following: 6.1.1 This Notice of Acceptance. 6.1.2 Completely dimensioned drawing showing size and location,including height above grade, ofopeningsto receive shutters;mean roof height,length andwidthof building. 6.1.3 Duplicate prints of approved drawings No.96-67,Sheets 1 through 7 of 7,bearing the approval stamp.Notice of Acceptance number and date by Dade County Product Control Section,clearly marked to show the components selected forthe proposed installation. 6.2 The Building Oflficiahshall ensure the adequacy of shutter to meet the pressure requirement of the openingin which itistobeinstalled. 6.3 This revision supersedes Notice of Acceptance No.95-0821.07 and Expires 8/15/97. jJLyltiJ*^ Helmy A.Makar.P.E.,Plans Examiner Product Control Division -2c- 7 APR-16-9T MED 10:27 FLfl METftL IND Ffrrfria Metal Industries 05 828 2182 P.07 ACCEPTANCE NO.:96-051V07 APPROVED ,:WW Q7 1996 EXPIRES :August IS.1997 NOTICE OP ACCEPTANCE:SPECIFIC CONDITIONS 7.TESTS PERFORMED TEST TEST LOAD DESIGN LOAD Deflection LARGE MISSILE IMPACT TEST SFOC PA 201-94 (70*SPAN)NOREINFORCING. SATISFACTORY HETI95-439 Max. 2.88" CYCLIC WIND PRESSURE TEST SFBC PA203-94(70*SPAN)POSITIVE +75.0 PSF HETI 95-439 +57.7 PSF HETI 95-439 CYCLIC WIND PRESSURE TEST SFOCPA 203-94 (70*SPAN)NEGATIVE -99.0 PSF HETI 95-439 -76.2 PSF HETI 95-439 UNIFORM STATIC AIR PRESSURE TEST SFBCPA202-94POS.(70"SPAN)NO REINFORCING, ♦87.0 PSF HETI 95-442 +58.0 PSF HETtr95-442 UNIFORM STATIC AIR PRESSURE TEST SFBCPA 202-94 NEG.(70"SPAN)NO REINFORCING. -114.0 PSF HETI 95-442 -76.0 PSF HETI 95-442 LARGE MISSILE IMPACT TEST SFBCPA 201-94 w/rdnforcing bars&bolts SATISFACTORY HETI 94-417 Max. 2.50" CYCLIC WINO PRESSURE TEST SFBC PA 203-94 POSITIVE +94.0 PSF HETI 95-417 +72.3 PSF HETI 95-417 CYCLIC WIND PRESSURE TEST SFBC PA 203-94 NEGATIVE -94.0 PSF HETI 95-417 -72.3 PSF HETI 95-292b UNIFORM STATIC AIR PRESSURE TEST SFBCPA202-94POS.(99"SPAN)W/REINFORCING. +108.00 PSF HETI 95-422 +72.0 PSF HETI 95-422 @ Design 0.847" UNIFORM STATIC AIR PRESSURE TEST SFBCPA 202-94 NEG.(99"SPAN)W/REINFORCING. -108.00 PSF HETI 95-422 -72.0 PSF HETI 95-422 Additional test reports for 96-0513.02 revision LARGE MISSILE IMPACT TEST (Unit A-1) SFBCPA 201-94 (106.5"SPAN)noreinforcing. SATISFACTORY MTL-16699 Max. 2.69" CYCLIC WIND PRESSURE TEST (Unit A-l) SFBC PA 203-94 POSITIVE +75.4 PSF MTL-16699 +58.0 PSF MTL-16699 CYCLIC WIND PRESSURE TEST (Unit A-l) SFBC PA 203-94 NEGATIVE -98.8 PSF MTL-16699 -76.0 PSF MTL-16699 LARGE MISSILE IMPACT TEST (UnitB-3) SFBCPA 201-94 (144.5"SPAN)with reinforcing. SATISFACTORY MTL-16699 Max. 2.75" CYCLIC WIND PRESSURE TEST (UnitB-3) SFBC PA 203-94 POSITIVE +74.4 PSF MTL-16699 ♦57.2 PSF MTL-16699 CYCLIC WIND PRESSURE TEST (UnitB-3) SFBC PA 203-94 NEGATIVE •98.4 PSF MTL-16699 -75.7 PSF MTL-16699 LARGE MISSILE IMPACT TEST (Unit C-4) SFBCPA 201-94 (106.125*SPAN)no reinforcing. SATISFACTORY MTL-16699 Max. 2.88* CYCLICWINDPRESSURE TEST (UnitC-4) SFBC PA 203-94 POSITIVE ♦67.6 PSF MTL-16699 ♦52.0 PSF MTL-16699 CYCLIC WIND PRESSURE TEST (UnitC-4) SFBC PA 203-94 NEGATIVE -72.8 PSF MTL-16699 -56.0 PSF MTL-16699 - -2d- r i a^i/-l..o c r>lA»%c FyHclmyAfMakar.P.E..Plans Examiner Product Control Division ftPR-16-97 MED 18:28 FLA METAL IND 05 828 2182 P-OS ^' ^.^l^ACCEPTANCE NO,WHUJB • APPROVED .:W 0 1 >89fr EXPIRES :August IS.1997 notice of acceptance-,specific CONDITIONS 8.EVIDENCE SUBMITTED 81 Tests** 8.1.1 Test report on Uniform Static Air Pressure Test of "Aluminum"storm panels,prepared by Hurricane Engineering &Testing.Inc..Report No.HETI-95-442.dated April 19.1995.signed and sealed by Hector M.Medina.P.E. 8.1.2 Test report on Uniform Static Air Pressure Test of "Aluminum"storm panels,prepared by Hurricane Engineering and Testing,Inc..Report No.HETI-95-422,dated February 17,1995. signedandsealedbyHectorM.Medina,P.E. 8.1.3 Test report on Large Missile Impact Test and Cyclic Wind Pressure Test of aluminum storm panels,prepared by Hurricane Engineering &Testing,Inc.,Report No.HETI-95-417,dated February 13,1995.signed and sealed by Hector M.Medina,P.E. 8.1.4 Test report on Large Missile Impact and Cyclic Wind Pressure Test of aluminum storm panels,prepared by Hurricane Engineering and Testing,Inc.,Test Report No.HETI 95-439 dated 06709/95,signedandsealedby Hector M.Medina,P.E. 8.1.5 Test report on Large Missile Impact and Cyclic Wind Pressure Testofaluminum storm panels,prepared by Miami Testing Laboratory,Test Report No.MTL-16699 dated 04/18/96, reissued 09/18/96 signedandseatedbyDavidG.Ober,P.E. 8.2 Drawing: 8.2.1 Drawing No.96-67,Florida Metal Industries,Inc.,"Storm Guard"Storm Panel,Sheets 1 through 7of7,prepared by Titteco Inc.,dated 03/13/96.with complete revision dated 09/16/96, signed and sealed by Walter A.TillitJr.,P.E. 8.3 Material certification: 8.3.1 Mill Certified Inspection Report,dated 11/15/94.for Aluminum Alloy 5052-H32 by Inespal Laminacionerwith chemical composition and physical properties. 8.3.2 Tensile Test Reports from HETI,Project if HETI 94-T68a and 94-T68b dated 04/11/95 for Aluminum sample,tested per ASTM E8-93,signed and sealed by Hector M.Medina,P.E. 8.4 Calculation: 8.4.1 Storm panel calculations prepared by Tilteco Inc.,signed and sealed by Walter A.Tillit Jr., P.E.,April 03,1996. isU^/X^"" Helmy A.Makar,P.E.,Plans Examiner Product Control Division 2e- 1 _AIPR~jL6-9T MED 10:29 FLA METAL IND 85 828 2182 P.89 •F,arfH,M^l Industries ACCEPTANCE NO.:_^^LLLQi^ APPROVED :KQV ft 7 Iflftfi EXPIRES :.August H IQQ? NOTICE OF ACCEPTANCE:.STANDARD CONDITIONS 1.Renewal ofthis Accqptance (approval)shall be considered aftera renewal application has been filed and the original submitted documents^including test supporting data,engineering documents,are noolderthaneight(8)years. 2.Anyand all approved products shallbe permanently labeled withthe manufacturer's name,city,state,and the following statement:"DadeCounty Product Control Approval",oras specifically stated inthespecific conditions of this Acceptance. 3.Renewals of Acceptance will notbe considered if: a)TherehasbeenachangeintheSouth Florida BuildingCodeaffectingtheevaluation ofthisproductandthe product isnotin compliance withthecode changes; b)Theproductisnolonger Che same product (identical)astheone originally approved; c)Ifthe Acceptance holderhasnot complied with alt the requirements ofthis acceptance,including the correct installation oftheproduct; d)The engineer who originally prepared,signed and sealed the required documentation initially submitted,isno longer practicing theengineering profession. 4.Any revision or change inthe materials,use,and/or manufacture of the product or process shall automatically be cause for termination ofthis Acceptance,unless prior written approval has been requested (through the filing ofa revision application with appropriate fee)and granted bythisoffice. 5.Any ofthefollowingshallalsobe grounds for removal ofthis Acceptance: a)Unsatisfactory performanceofthis product or process; b)Misuse ofthisAcceptanceasanendorsementof anyproduct,for sates,advertisingoranyother purposes. 6.The Notice of Acceptance number preceded bythe words Dade County.Florida,and followed bythe expiration date maybe displayed inadvertising literature.If any portion ofthe Notice of Acceptanceisdisplayed,thenit shall be donein its entirety. 7.Acopy ofthis Acceptance as well as approved drawings andotherdocuments,whereit applies,shallbe provided to theuserbythe manufacturer orits distributors and shall be available for inspection atthejobsiteatalltime.The copiesneednotbe reseated bythe engineer. 8.Failure tocomplywithanysection ofthis Acceptance shall be cause for termination andremoval of Acceptance. 9.This Acceptance contains pages 1,2,2(a)through 2(e)and this last page 3. Items 10.11 A 12 listedbelowonlyapply to plated nrodueft *nrf door? 10.Unless specifically indicated inthe Acceptance (approval),this unit h approved asa single unit installation.For multiple installation ofthis unit,a separate Acceptance for mullions is required from the Product Control Section. 11.The spacing of fasteners atwindowsills shall beas tested.The spacing of fasteners inallother parts ofthe frame, shallbeas tested,but innocaseshall exceed 24"oncenter.Thefirst fastener shallbelocatedata maximum of6" from each corner and mullion or stile.Fastener shall fully penetrate the buck,which shall bethesamesizeastheone tested withtheunit.Nowoodor plastic shields or pins shall be used for anchoring.Sec section four (4)ofthis approval forsizes of fasteners usedin testing. 12.Hardware for all windows and doors shall conform to Security and Forced Entry Prevention,Chapter 36 of Ihc South Florida Building Code. END OF THIS ACCEPTANCE -3- jle/*&/f./(~4: Helmy /K Makar,P.E..PlataHelmyXTMakar,P.E..Plans Examiner Product Control Division -7 APR-16-97 WED 18:38 FLA METAL IND FloRidA MetaI hdusTRiEs,Inc. HEADER DETAIL SHI- OETAIlN -4^ MASONRY OPENING HEIGHT 85 828 2182 P.18 TOPOFPANEL- 1 1 3/i er T 4 ti/ier PANEL -/• Direct Mount Installation ANCHORTO MAIN STRUCTURE MASONRY OPENING HEIGHT HEADER DETAIL •s- MASONRY OPENING HDGHT 411/16" PANEL 1 3/16T BOTTOMOFPANEL - TYPICAL SECTION SILL DETAIL APR-16-9T WED 18:31 FLA METAL IND FIoricIa MetaI hdusTRiES,Inc, The Direct Mount installation isthesimplest andmosteconomicalavailable.The panels mountdirectlytothe walL When the mounting screwsarepaintedtomatchthecolor of the surface,the hardware becomespracticallyinvisible to observers. 85 828 2182 P.1 1 Direct Mount Installation OVERLAP ADDITIONAL PANELS AS NEEDED MAXIMUM DESIGN LOAD (p.s.f.l MAXIMUM PANEL SPAN MIN SEPARATION TO GLASS STANDARDINSTALLATION +58.0,-76.0 5*-10" (70")27/8" WITH 1M*HORIZONTAL RQNFORCEMENT TUBE +72.0-72.0 8*-3" (99") 21/2"