12-86 70F7-241I NO IN On IF IV 11w 11M IN Igo 11f is B IV 1 2 3 4 5 6 FI 7 8 9 10 11 RE ALARM SYSTEM NOTES 1- THE ELECTRICAL CONTRACTOR TO MAKE PROVISIONS FOR CONNECTION TO A 24 HOUR SUPERVISORY CENTRAL STATION, U.L. APPROVED, IF OWNER CHOOSES TO INSTALL. 2- ACTUAL FIELD WIRING REQUIREMENTS SHALL BE AS INDICATED BY EQUIPMENT SUPPLIER ON APPROVED SHOP DRAWINGS. 3- ALL A.H.U.S. IN EACH BUILDING MUST SHUT DOWN WITH ANY ALARM INITIATED WITHIN THE PARTICULAR BUILDING 4- SYSTEM SHALL HAVE BUILT -IN BATTERY BACK -UP FOR 4 HOURS STAND -BY AND 5 MINUTES ALARM 5- ALL WIRING SHALL BE IN CONDUIT, 3/4" DIAMETER MINIMUM, MAXIMUM CONDUIT FILL - 40% OF CONDUIT AREA 6- FIRE ALARM MAIN CONTROL PANEL SHALL BE A 24V., POWER LIMITED SYSTEM, ADDRESSABLE SYSTEM WITH FIRE DEPARTMENT COMMAND CENTER REFER TO PROJECT SPECIFICATIONS. 7- ALL EQUIPMENT SHALL BE U.L. LISTED BY UNDERWRITER'S LABORATORIES FOR THE INTENDED USE AND SHALL MEET WITH THE APPROVAL OF THE LOCAL FIRE AUTHORITIES. THE COMPLETE INSTALLATION SHALL BE MADE IN ACCORDANCE WITH N.F.P.A. #72 SERIES, ALL LOCAL CODES AND REQUIREMENTS N.F.P.A. #101 AND N.E.C. ARTICLE 760. ANSI A117.1,4.26 AND SOUTH FLORIDA BLDG. CODE CHAPTER 515.3 8- FIRE DEPARTMENT COORDINATION AND COOPERATION: A. THE ELECTRICAL CONTRACTOR SHALL COORDINATE AND COOPERATE FULLY WITH THE FIRE DEPARTMENT AND GIVE AT LEAST TWENTY FOUR (24) HOURS NOTICE OF ALL WORK REQUIRING FIRE DEPARTMENT NOTIFICATION AND ASSISTANCE. B. SUBMIT COMPLETE WIRING DIAGRAM SHOP DRAWINGS INCLUDING BATTERY AMPERE -HOUR CALCULATIONS FOR APPROVAL BY FIRE MARSHALL PRIOR TO ANY WORK BEING PERFORMED. BATTERY CAPACITY SHALL EXCEED TOTAL SYSTEM LOADING. 9- SMOKE DETECTORS SHALL NOT BE LOCATED CLOSER THAN 4 FEET FROM ANY AIR SUPPLY DIFFUSER OR WHERE BLOCKED BY CEILING PROTRUSION. 10- ACTIVATION OF ANY INITIATING DEVICE WITHIN A BUILDING (MANUAL STATIONS IN ALARM OR SMOKE DETECTOR) SHALL SOUND THE HORNS AND STROBE LIGHTS SHALL BE ACTIVATED TROUGHOUT THE BUILDING. THE MAIN FIRE ALARM CONTROL PANEL AND BOTH REMOTE ANNUNCIATORS SHALL INDICATE THE DEVICE IN ALARM. 11- ALL INITIATING DEVICES SHALL BE SUPERVISED AND ANY TROUBLE CONDITION SHALL SOUND AN ALARM AT MAIN FIRE ALARM PANEL AND AT BOTH ANNUNCIATORS. 12- THE HORNS AND STROBE LIGHTS CIRCUIT SHALL BE ELECTRICALLY SUPERVISED AND ANY TROUBLE CONDITION SHALL SOUND A BUZZER AT THE MAIN FIRE ALARM CONTROL PANEL AND BOTH ANNUNCIATORS. 13- SMOKE DETECTORS BY EACH ELEVATOR SHALL RECALL ELEVATOR ACCORDING TO LOCAL AUTHORITIES. 14- AIR HANDLER SHUT DOWN RELAYS SHALL BE CONNECTED IN A FAILED SAFE MODE. 15- SMOKE DETECTORS IN FRONT OF THE ELEVATOR DOORS AND A/C DUCT SMOKE DETECTORS SHALL BE OF THE PHOTOELECTRIC TYPE. OTHER SMOKE DETECTORS ARE OF THE IONIZATION TYPE. 16- PROVIDE WIRING, CONDUIT OUTLET BOXES AND JUNCTION BOXES REQUIRED FOR THE INSTALLATION OF THE NEW SYSTEM. FIRE ALARM COMMUNICATIONS WIRING SHALL BE TWISTED AND SHIELDED CABLE AND AS INDICATED BELOW. ALL WIRING SHALL BE IN COMPLETELY SEPARATE CONDUITS, FROM ANY OTHER SYSTEM. ROUTE AS PER MANUFACTURER'S INSTRUCTIONS. 17- COLOR: THE FOLLOWING TYPES OF WIRING WITH THE DESIGNATED COLOR CODE SHALL BE USED FOR ALL CONDUCTORS: SIGNALING LINE CIRCUIT - TWISTED SHIELDED PAIR - #18 AWG. WEST PENN - 1975 (UL LISTED NEC TYPE NPLF) ANNUNCIATOR SERIAL COMMUNICATION - TWISTED SHIELDED PAIR - #18 AWG. WEST PENN - 1975. INDICATING APPLIANCE CIRCUIT - #12 AWG. THHN. COLOR - ORANGE ( +) AND BLANK ( -). AUXILIARY POWER CIRCUIT - #12 AWG THHN. COLOR - BROWN ( +) AND YELLOW ( -). AIR HANDLING CONTROL - #14 AWG THHN. COLOR - PURPLE AND PINK DOOR HOLDER /RELEASE CONTROL - #12 AWG. THHN. COLOR - RED AND WHITE. POWER SUPERVISORY CIRCUIT -1 #14 THHN. COLOR BROWN ( +) AND YELLOW ( -) SPARE 2 - #12 AWG. THHN. COLOR - WHITE GROUND -1 - #12 AWG. THHN. COLOR - GREEN (AT LEAST ONE GROUND WIRE IN EVERY NEW CONDUIT) 18 -THERE SHALL BE NO CUTS OR SPLICES IN THE WIRING BETWEEN TERMINAL BOXES. 12 1 13 14 15 16 17 SCHEDULE O ADDRESSABLE LOOP WIRING, FOR INITIATING DEVICES, FOR THE DESIGNATED FLOOR, 1 "C. OB 24V. INDICATING LOOP WIRING (HORNS AND STROBES) IN 3/4 7C. © FIREMAN'S PHONE JACK COMM. WIRING IN 314C. O REMOTE ANNUNCIATOR COMM. WIRING IN 314C. O DATA LOOP- COMMON AREAS OF NETWORK COMM. WIRING IN 1 "C. NOTES: 1-REFER TO SHEETS E -8.07, 8.08, 8.09, 8.10 FOR FIRE ALARM RISER DIAGRAMS FOR EACH INDIVIDUAL BUILDING. THESE INDIVIDUAL BLDG. RISER DIAGRAMS DEPICT THE CONTINUATION OF THE FIRE ALARM SYSTEM TO INITIATING AND ANNUNCIATION DEVICES, 106 i I I L - - - - - - - — — — — — — — — — — — — — — — — _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _mil —� �-- F F FIRE ALARM SYSTEM - NETWORK RISER DIAGRAM N.T.S. 1 1 2 � 3 4 � 5 6 � 7 � 8 � 9 � 10 1 11 1 12 13 14 1 15 1 16 1 17 1 18 IMtn) IU) I m Ipla11 a I M I \U iL U L] NATIONAL CITY CENTER P.O. BOX 7033 INDIANAPOLIS, IN 96207 (317) 636-16W L KI (a TIME _] CCOMRAS COMPANY 1111 Lincoln Road Mall Suite 510 Miami Beack FL. 33139 (305) 532-0433 �I • ARamcIVRR- HNGINBmm PLANNING -ufmam D=GN 5960 S.W. 57TH AVE. MIAMI, FLORIDA 33143 E v 0 E FAX (305) 666 -4994 B ANGEL E. LORENZO, P.E. A • REG. NO. 31137 E ISSUE DATE 0 A =o B c : ° REVISION DATE 08-07-96 C C PRICING DOC. 9 -12 -96 =o =z B B : W O B E :Q A CADD FILE NAME E- 806 —RT A DRAWING TITLE F.A. RISER DIAGRAM SHEET NUMBER A E8.06 REMOTE REMOTE CONTROL CONTROL PANEL PANEL BLDG. "B" RESIDENTIAL BLDG. "B" ELECT. ROOM ELECT ROM L----------- I il 16- PROVIDE WIRING, CONDUIT OUTLET BOXES AND JUNCTION BOXES REQUIRED FOR THE INSTALLATION OF THE NEW SYSTEM. FIRE ALARM COMMUNICATIONS WIRING SHALL BE TWISTED AND SHIELDED CABLE AND AS INDICATED BELOW. ALL WIRING SHALL BE IN COMPLETELY SEPARATE CONDUITS, FROM ANY OTHER SYSTEM. ROUTE AS PER MANUFACTURER'S INSTRUCTIONS. 17- COLOR: THE FOLLOWING TYPES OF WIRING WITH THE DESIGNATED COLOR CODE SHALL BE USED FOR ALL CONDUCTORS: SIGNALING LINE CIRCUIT - TWISTED SHIELDED PAIR - #18 AWG. WEST PENN - 1975 (UL LISTED NEC TYPE NPLF) ANNUNCIATOR SERIAL COMMUNICATION - TWISTED SHIELDED PAIR - #18 AWG. WEST PENN - 1975. INDICATING APPLIANCE CIRCUIT - #12 AWG. THHN. COLOR - ORANGE ( +) AND BLANK ( -). AUXILIARY POWER CIRCUIT - #12 AWG THHN. COLOR - BROWN ( +) AND YELLOW ( -). AIR HANDLING CONTROL - #14 AWG THHN. COLOR - PURPLE AND PINK DOOR HOLDER /RELEASE CONTROL - #12 AWG. THHN. COLOR - RED AND WHITE. POWER SUPERVISORY CIRCUIT -1 #14 THHN. COLOR BROWN ( +) AND YELLOW ( -) SPARE 2 - #12 AWG. THHN. COLOR - WHITE GROUND -1 - #12 AWG. THHN. COLOR - GREEN (AT LEAST ONE GROUND WIRE IN EVERY NEW CONDUIT) 18 -THERE SHALL BE NO CUTS OR SPLICES IN THE WIRING BETWEEN TERMINAL BOXES. 12 1 13 14 15 16 17 SCHEDULE O ADDRESSABLE LOOP WIRING, FOR INITIATING DEVICES, FOR THE DESIGNATED FLOOR, 1 "C. OB 24V. INDICATING LOOP WIRING (HORNS AND STROBES) IN 3/4 7C. © FIREMAN'S PHONE JACK COMM. WIRING IN 314C. O REMOTE ANNUNCIATOR COMM. WIRING IN 314C. O DATA LOOP- COMMON AREAS OF NETWORK COMM. WIRING IN 1 "C. NOTES: 1-REFER TO SHEETS E -8.07, 8.08, 8.09, 8.10 FOR FIRE ALARM RISER DIAGRAMS FOR EACH INDIVIDUAL BUILDING. THESE INDIVIDUAL BLDG. RISER DIAGRAMS DEPICT THE CONTINUATION OF THE FIRE ALARM SYSTEM TO INITIATING AND ANNUNCIATION DEVICES, 106 i I I L - - - - - - - — — — — — — — — — — — — — — — — _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _mil —� �-- F F FIRE ALARM SYSTEM - NETWORK RISER DIAGRAM N.T.S. 1 1 2 � 3 4 � 5 6 � 7 � 8 � 9 � 10 1 11 1 12 13 14 1 15 1 16 1 17 1 18 IMtn) IU) I m Ipla11 a I M I \U iL U L] NATIONAL CITY CENTER P.O. BOX 7033 INDIANAPOLIS, IN 96207 (317) 636-16W L KI (a TIME _] CCOMRAS COMPANY 1111 Lincoln Road Mall Suite 510 Miami Beack FL. 33139 (305) 532-0433 �I • ARamcIVRR- HNGINBmm PLANNING -ufmam D=GN OF 5960 S.W. 57TH AVE. MIAMI, FLORIDA 33143 (305) 666 -5474 E FAX (305) 666 -4994 A.A.C. 000404 ANGEL E. LORENZO, P.E. FL. ELECTRICAL ENGINEER REG. NO. 31137 ISSUE DATE 0 =o c : ° REVISION DATE 08-07-96 PRICING DOC. 9 -12 -96 =o =z = U : W O B :Q CADD FILE NAME E- 806 —RT DRAWING TITLE F.A. RISER DIAGRAM SHEET NUMBER A E8.06 OF