Loading...
12-86 70F7-236VAN Ins H /, p /. p !. A 000 A. BUS DUCT F.P.& L. TRANSFORMER N VAULT SS BLDG. A 2000 1 2 3 4 5 6 7 8 9 1 10 1 11 12 13 1 14 15 16 17 18 DUCT � r NOTES: O BOND GROUND BUS TO REINFORCING STEEL IN BUILDING FOUNDATION AND TO THE COLD WATER PIPE. USE 1 -3/0 AWG. 13 4" HIGH, CONCRETE, HOUSE PAD. M O REFER TO BLDG. A ONE -LINE DIAGRAM, SHEET FOR RATING AND SIZES OF EQUIPMENT, BUSWAYS, CONDUCTORS, CONDUITS AND OTHER ADDITIONAL INFORMATION NOT SHOWN ON THIS DRAWING. IN 3/4 "C., EXOTHERMICALLY WELDED. O8 3/4 "X 10', COPPER -CLAD GROUND ROD, CONNECT TO GROUND 14 PROVIDE SUFFICIENT SLACK CONDUCTOR LENGTH OR CONNECTIONS TO F.P. & L. CO. TERMINALS. REFER TO NOTE 2 PANEL PANEL O BUS STUBS INTO F.P. & L. VAULT ARE SHOWN VERTICALLY DISPLACED FOR THE PURPOSE OF CLARITY. REFER TO SHEET , ENLARGED ELECTRICAL ROOM PLANS FOR INTENDED LOCATION OF BUS STUBS AND ORIENTATION OF SWITCHGEAR. CONTRACTOR SHALL COORDINATE BUS WITH 1-3/0 AWG, EXOTHERMICALLY WELDED TO GROUND ROD AND BOLTED TO THE GROUND BUS. Og 3/47X 109, COPPER -CLAD GROUND ROD. CONNECT TO TRANSFORMER 15 CONNECT GENERATOR NEUTRAL TO GROUND ROD AND GROUND BUS BAR. BOND TO GENERATOR FRAME. GENERATOR IS AS SEPARATELY DERIVED SYSTEM. -o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ns H /, p /. p !. A 000 A. BUS DUCT F.P.& L. TRANSFORMER N VAULT SS BLDG. A 2000 A. BUS DUCT MAIN N0. 3 (305) 666 -5474 1200 A. BUS DUCT HSA iss MAIN N0. 1 2500 A. BUS DUCT FEEDER PULL SECTION f FEEDER PULL SECTION TD81 TD62 � � TD83 (FUTURE) ,n -� i j - -1 - -- � II I MAIN N0. 3 (305) 666 -5474 N SS SS FAX (305) 666 -4994 TD85 TDB3 FUTURE�,n -� i � - -1 - -- I II I �� HSA iss MAIN N0. 1 REG. NO. 31137 MAIN N0. 2 MAIN N0. 4 � r MAIN N0. 5 PASS PANEL PANEL LIGHTING PANEL "LA" -o PANEL "HHA" TV1 BUILDING "A" MAIN ELECTRICAL ROOM BUILDING "A" GENERATOR ROOM 6 I v I -- GND >> GND ND _ _ _ — 11 _ @ I E I I - � BUILDING "A" ELECTRICAL ROOM A -143 D c � XFMR. "THA" 4 2 SECT ONS I I P� L I (A� „A I I PANE PAL I I ATS "E1 "I I GDP HLA' i A BUILDING "A" ELECTRICAL RISER DIAGRAM 1 2 3 4 5 6 N.T.S. 7 8 XFMR. n ET PANEL EG' EGL I I I PANEL C.B. NO.2 EMERG. NERATOR C.B. l N0.1 15 I I 6'-0" (MIN.) I FIRE SPRINKLER PUMP CONTROLLER AND I AUTOMATIC TRANSFER FIRE SWITCH PUMP 75 H.P. c I 6,_On O 9 10 11 12 13 14 15 16 17 18 I M I \�tA iL k� �V_ !L-J NATIONAL CITY CENTER P.O. BOX 7033 INDIANAPOL[5, IN 96207 (317)636 -1600 I HE COMRAS COMPANY 1111 Lincoln Road Mall Suite 510 Miami Beach, FL. 33139 (305) 532-0433 r r> > I o w x H o G F 1\0)111M; I I an I -'al I v, RIM) ARC=C1 M - 24GII EMMG PLANNING -IIV WOR DRSIGN 5960 S.W. 57TH AVE. MIAMI, FLORIDA 33143 (305) 666 -5474 E FAX (305) 666 -4994 TV ANGEL E. LORENZO, P.E. iss FL. ELECTRICAL ENGINEER REG. NO. 31137 t •- SS r PASS PANEL PANEL LIGHTING PANEL "LA" -o PANEL "HHA" TV1 ELEV. "FEA" "HHA2" CONTACTOR REVISION DATE c SSI MAIN PRICING DOC. CABINET -o -z G - I- G - U _ W 11 16 _ O _ Q WIREWAY CADD FILE NAME 11 E- 801 -RT DRAWING TITLE ELECTRICAL RISER DIAGRAM 6 I v I -- GND >> GND ND _ _ _ — 11 _ @ I E I I - � BUILDING "A" ELECTRICAL ROOM A -143 D c � XFMR. "THA" 4 2 SECT ONS I I P� L I (A� „A I I PANE PAL I I ATS "E1 "I I GDP HLA' i A BUILDING "A" ELECTRICAL RISER DIAGRAM 1 2 3 4 5 6 N.T.S. 7 8 XFMR. n ET PANEL EG' EGL I I I PANEL C.B. NO.2 EMERG. NERATOR C.B. l N0.1 15 I I 6'-0" (MIN.) I FIRE SPRINKLER PUMP CONTROLLER AND I AUTOMATIC TRANSFER FIRE SWITCH PUMP 75 H.P. c I 6,_On O 9 10 11 12 13 14 15 16 17 18 I M I \�tA iL k� �V_ !L-J NATIONAL CITY CENTER P.O. BOX 7033 INDIANAPOL[5, IN 96207 (317)636 -1600 I HE COMRAS COMPANY 1111 Lincoln Road Mall Suite 510 Miami Beach, FL. 33139 (305) 532-0433 r r> > I o w x H o G F 1\0)111M; I I an I -'al I v, RIM) ARC=C1 M - 24GII EMMG PLANNING -IIV WOR DRSIGN 5960 S.W. 57TH AVE. MIAMI, FLORIDA 33143 (305) 666 -5474 E FAX (305) 666 -4994 A.A.C. 000404 ANGEL E. LORENZO, P.E. FL. ELECTRICAL ENGINEER REG. NO. 31137 t •- J r ISSUE DATE -o -o REVISION DATE c 08-07 — -� PRICING DOC. -o -z - I- - U _ W _ O _ Q CADD FILE NAME E- 801 -RT DRAWING TITLE ELECTRICAL RISER DIAGRAM SHEET NUMBER A E8.01 OF