Loading...
12-86 70F7-232M J H G F E C B iA fl 1 2 FD /SD 4 I 5 SQ. "Cr MINI POWER ZONE "EPA" (MPZ5540F) FD /SD FD /SD G TO MAIN ELECTRICAL ROOM. / uu F/A PANEL "EA" SF -A6 EPA -1 EPA -4 F/A EPA -2 - - PANEL EA2" - - - - TDB4 SF -A5 M M LIGHTING TO MAIN ELECTRICAL ROON CONTACTORS A -143 PANEL "TD131" T CABINET S 0 EPA -5 - v PANEL "2 HA" T.T.B 2LA -14 T S 2LA -16 I PANEL TO MAIN ELECTRICAL ROOM _ "THA2" PANEL "EPA" PANEL " H HA" 11.1 BLDG. A ELEC. ROOM A -143 SCALE: 1/2 " =1' -0" IDA L ft— I w1AA&&1 P_ HSD "BMS' CONTROL ANEL O PD -6 PANEL. EDGE OF CONC. 7p814 HOUSE PAD PANEL "HLD" � � - - - -1 D -103 li � TRANSF. j H _y THE" i TD613 H I I � D L � TO F.P. & L. TRANSFORMER SUSPEND FROM VAULT, BLDG. "C' � L STRUCTURE ABOVE. rl D BOTTOM OF SUPPORTS AT APPROX. 9' -0" A.F.F. LIGHTING EPD -2 4 3 C. W HEAT CONTACTORS � CABINET DEFECTOR SIGNAL EPD -2 WIRING P F � ELEVATOR MAIN WITH SHUNT -TRIP DEVICE S.1 TOF.P. &L TRANSFORMER VAULT BLDG. C � GROUND BUS BAR SEE DETAIL, DWG. E6.01 (TYP.) PANEL "EDP" BLDG. D ELEC. ROOM - D -103 SCALE: 1 /2 " =P -O" 2 3 1 4 1 5 6 1 7 FD /SD F/A 8 I 9 I 10 1 114 CONDUIT THROUGH' WALL FOR METERING COORDINATE LOCATION & HEIGHT WITH F.P. & L. CO. 11 TO DISTRIBUTIO BOARD "HSD" . BLDG. "D" SEE ONE LINE DIAGRAM DWG. E7.02 F.P.L. N�' TRANSFORMER VAULT 4" HIGH CONCRETE PEDESTAL (TYP.) TO ELEV. MAIN, BLDG. "D" SEE ONE LINE DIAGRAM DWG. E7.02 TO TENANT MAIN NO.1 BLDG. "D" SEE ONE LINE DIAGRAM, DWG. E7.02 NOTES: 1- PROVIDE 30 ft. OF CABLE SLACK, INSIDE VAULT, FOR ALL SERVICE CONDUCTORS. 2. COORDINATE BUS STUBS PENETRATIONS WITH F.P. & L. CO. 3. REFER TO RISER DIABRAM FOR GROUND BUS BAR CONNECTIONS. 0 10 11 36" MIN. (TYP.) 12 1 13 1 14 15 16 17 V � EPC -2 10.2 � "BMS" � PANELOL FEEDER PULL SECTION BLDG. C MAIN ELEC. ROOM - C -104 SCALE: 1/2 " =1' -0" BD �� BLDG. C ELEC. ROOM - C -110 D SCALE: 1/2 " =1' -0" 12 1 13 14 15 FIRE ALARM PANEL PANEL "EC' "ATS" C PANEL "H LC" 2 SECTIONS COORDINATE LOCATION OF CONDUIT STUB -UPS WITH FINAL LAYOUT FOR NIKE ELECTRICAL ROOM TRANSF. "THC" —PANEL "HHC" MV NATIONAL CITY CENTER P.O. BOX 7033 INDIANAPOLIS, IN 46207 (317)6,%-1600 THE CCOMRAS COMPANY 1 111 Lincoln Road Mall Suite 510 Miami Beach, FL. 33139 (305) 532 -0433 . , . . . I 0 a w x E-+ H o rn G F I"..•\ I -s i I I \ 1 � M's ARCMnCnM - HNGMMMiG PLANNING - I T=0R DMGN 5960 S.W. 57TH AVE. MIAMI, FLORIDA 33143 (305) 666 -5474 E FAX (305) 666 -4994 A.A.C. 000404 ANGEL E. LORENZO, P.E. FL. ELECTRICAL ENGINEER REG. NO. 31137 ISSUE DATE °o c : o� REVISION DATE "M PRICING DOC. DDENDUM #1 -0 -z - U _ w .0 .a CADD FILE NAME E- 505 -RT DRAWING TITLE ELECTRICAL ROOMS SHEET NUMBER A E5.05 16 17 18 0�