12-86 70F7-187A. 1 I 2 I 3 I 4 L a� ar 9 i a J rp I IE D C i a a a 1 3" MIN. 6" MAX. ROOF MTD. AND/OR ROOF PENETRATING EQUIPMENT- 5 � DOUBLE NUTS WRENCH TIGHT WASHER 1- 1/7'O.D.X10G. 5/8" EYE BOLT DOUBLE CABLE CLAMPS TYP. AT ALL POINTS 22.50 MIN. ANGLE TURNBUCKLE 5/16" 6X7 GALV, WIRE ROPE GUYS 0 518" EYE BOLT. IF FASTENED TO STEEL TO BE DONE SAME AS TOP EYE BOLT. IF INSERTED IN CONC. USE "RED HEAD" R -58 SELF DRILLING CONC. ANCHOR & EYE BOLT W11 -112" MIN. NOTE: THREAD DEPTH EACH OF 4 CORNERS OF ROOF MTD. EQUIP. TO BE GUYED IN THIS FASION. ALL HARDWARE TO BE GALV. OR CADMIUM PLATED FORGED STEEL ASTM —A -325. HURRICANE SUPPORT DETAILS N.T.S. SOLENOID VALVA VALVE W/ EXTERNAL EQUALIZER-7 DRIER DX CLOSE COIL VALVE SUCTION LINE AIR HANDLING UNIT ANGLE PITCH ui VALVE 4 FLEXIBLE CONNECTION AIR COOLED COND. UNIT SUCTION LINE PITCH G ON DOUBLE PORT CHARGING SIGHT GLASS VALVE REFRIGERANT PIPING DIAGRAM N.T.S. 8 I 9 I 10 I 11 I 12 HANGER RODS SECURED TO STRUCTURE (TYPICAL AT EACH MOUNTING POINT OF AIR HANDLING UNIT) CHS PLENUM SUPPORT SPRING (TYPICAL) ISOLATORS CHR RETURN AIR FLEXIBLE PLENUM CONNECTION (SOUND LINED) (TYPICAL) •—\ 1001 —( FAN COIL I I I "ND F COIL SUPPLY AIR DUCT Lo _j SECTION SECTION jL11111111— --] ZOUTSIDE AIR DUCT AUX. DRAIN PAN SECURE TO AHU. (SEE PLBG. DWGS. 1" THICK FILTER RETURN AIR FOR DRAIN CONNECTION) DUCT CEILING) TYPICAL FAN COIL UNIT MOUNTING DETAIL N.T.S. SPRING ISOLATOR CURB MTD. SPRING BASE —� FLEX.NEOPRENE WEATHER SEAL EYEBOLT 3/8' DIA. X 3" LENGTH W/2 WASHERS & 1 FULL NUT Ago =--aw .. � EQUIP.UFf1NG LUGS 114 DIAMETER X 36" LENGTH LOOP CABLE THRU EYEBOLT & LIFTING LUG. ADJUST CABLE FOR APPROX.1/8" STACK W/ CABLE CLAMP AS SHOWN HOLDING 2 END LENGTH) AFTER UNIT IS OPERATING, CHECK SLACK AND READJUST IF REQUIRED CABLE CLAMP / -4X4 CANT STRIP .��FOR ROOF FLASHING DETAIL SEE ARCHITECTURAL DWG S., Y vNF OUTDOOR AIR HANDLING UNIT MOUNTING DETAIL N.T.S. GALV. ANGLE SUPPORT s CONNECT ANGLES WITH AIR DUCT W EXTERNAL 1 /4 0 BOLT (GALV.) iYP P . — — — — — — — — — /— wr�ruro nnc oinin 2 PLACE II TYPICAL II 2-PLACES 3�1 ml WEATHER INSULATION WELD PIPE TO CHANNEL 12" x 12" x 31S" BASE PLATE W4-3/9"x' HILTI KWIK -BOLTS 2BEDMENT R EQUAL), PROVIDE 1 5/8" 3 " O STANDARD PIPE C4 " DTL. CHANNEL (TYPICAL) z WEIGHT COLUMN (TYP,) WELDED PIPE SUPPORT OF COLUMN & PLATE REFER TO ARCHITECTURAL to (nP•) 214 DRAWINGS FOR FLASHING ,- DETAILS (TYPICAL) 4. O r} • it •i... IA STRUCTURAL SLAB � e * - SEE FLOOR PLAN FOR DIMENSIONS f T 1 11 s 1 1/2" BASE PLATE DUCT ON ROOF SUPPORT DETAIL N.T.S. 10 12 13 IV IN m lu HANGER RODS SECURED TO STRUCTURE I�� I �(IYPICAL AT EACH MOUNTING POINT OF PIPES) NATIONAL CITY CENTER ` P.O. BOX 7033 1/4!' THICK INDIANAPOLIS, IN 46207 NEOPRENE (317) 636 -1600 SLEEVE I'f, SHEET METAL SADDLE % L HANGER RODS STRAPS LIQUID SUCTION CHANNEL IIVJVLJ11 lull — 11 REFRIGERANT PIPE HANGER DET�A4L N.T.S. T T 1 �CHWR CIRCUIT SETTER BALANCING VALVE (NP.) THREE -WAY CONTROL VALVE CHWS � I PRESS. GAUGE GAUGE COCK SHUT -OFF VALVE � � (NP.) (BUTTERFLY TYPE) / (NP.) STRAINER W/ �AIR F BTM � OWN VA. ( AUTOMATIC � / AIR VENT. (NP.) r / '+ �AlR FLOW THERMOMETER COIL PULL � SPACE THERMOMETER WELL FULL SIZE / W /CAP HEADERS NOTE: PIPE COIL FOR DRAIN W /HOSE COUNTERFIOW ARRANGEMENT COUPLING (NR MULTIPLE CHILLED WATER COIL PIPING DETAIL N.T.S. • � CHWR CIRCUIT SETTER BALANCING THREE -WAY CONTROL VALVE (NP.) VALVE CHWS I i'�TMP�• GAUGE GAUGE COCK SHUT -OFF VALVE � (NP.) (BUTTERFLY TYPE) (NP.) STRAINER W/ I � '+ 4%�IR FLOW SLOWDOWN VA. AUTOMATIC / / AIR VENT. (NP.) I / J \\\-THERMOMETER / /� `THERMOMETER WELL �np) / W /CAP DRAIN W /HOSE COIL PULL COUPLING (NP.) SPACE NOTE: PIPE COIL FOR COUNTERFLOW ARRANGEMENT CHILLED WATER COIL PIPING DETAIL N.T.S. 14 i • • ARC uncrORB • RNGINRBRING PLANNING • IIQ WOR DBEGN 5960 S.W. 57TH AVE. MIAMI, FLORIDA 33143 (305) 666 -5474 E FAX (305) 666 -4994 A.A.C. 000404 MARIO H. GUTIERREZ, P.E FL. MECHANICAL ENGINEER REG. NO. 0019687 ISSUE [SATE >�ca .cq :C� REVISION DATE P ICI G DOC. :z 0 .a CADD FILE NAME M702 -RT DRAWING TITLE HVAC- DETAILS A SHEET NUMBER K M7.02 14 15 16 17 18 OF