12-86 70F7-115In
If7
la
IW
11451
G
F
I E
ion
1 1 2
PDI -C
4" GAS LINE ABOVE
COL. CAPPED FOR
FUTURE USE (TYPICAL)
4"
C '
I�
• 3/4'
I r CW OUTLET VALVED /
I
AND CAPPED FOR
IFUTURE USE /
4" GAS LINE ABOVE '
COL. CAPPED FOR I / ' 3/4 "�
FUTURE USE (TYPICAL)
AIR CHAMBER I
(TYPICAL)
LOCKABLE VALVE i� 3/4" WH
(TYPICAL BY TENANT.) ' / ' / I
SOLENOID VALVE WITH FROM BLDG. "C" / / 2 -1 1r
(TYPICAL RESET
CAL BY TENANT.) ' / ' / I
`� r CW OUTLET VALVED
AND PROVIDE TEMPORARY CAP I FUTUREPUSE FOR
FOR METER AND REGULATOR _ ,
BY GAS COMPANY (TYPICAL) WH
3/4" 3/4"
GAS PIPING DIAGRAM ,� `� /
10 1 11
N.T.S.
\ ELECT. GROUND
/ Cr A.F.F.
` / I
i 314" 314 �
I i
I
3/4" / m
e
II 4" V.T.R. _J i L
I I L WH
AIR CHAMBER I 3 4" ' � - -3
I I
� I
AIR CHAMBER I
I (TYPICAL) I
Y THIRD FL
Il 45 DN WRAP AROUND COLUMN
I SEE STRUCTURAL (TYPICAL) y
r
WH 3" VENT LINE
i CAPPED FOR FUTURE
I USE (TYPICAL)
I
4" 1
I �
I
COLD WATER ISOMETRIC �" 4" SANITARY LINE SECOND FL. 6"
CO
N.T.S. CAPPED FOR FUTURE
USE (TYPICAL) W /
I
4• I
WOO
4"
III. i
6" WCO
4" SANITARY LINE 4•
CAPPED FOR FUTURE
USE (TYPICAL) Sp1,1/ GROUND FL.
TWO WAY CLEAN
OUT TO GRADE-
6r SANITARY LINE
0 1 /8" /FT
SEE CIVIL DWGS.
FOR CONTINUATION
(f 600 FU)
6' GREASE WASTE LINE
0 1 /13" /FT
SEE C -P3.00 FOR
CONTINUATION
12
13
14
15
16
O1
4" V.T.R. J I L
� I
a
,I
I
3" VENT LINE
CAPPED FOR FUTURE I
USE (TYPICAL) , I THIRD FL.
I
4" SANITARY LINE �` I
CAPPED FOR FUTURE I
USE (TYPICAL) I
S I
I 4
4' V.T.R. -J 'L I
3" VENT LINE
I I
I CAPPED FOR FUTURE I
1 USE (TYPICAL) I
1 SECOND FL.
I 1
17 1 18
M I%Ahk� 11\1J/ �V- �L
NATIONAL CITY CENTER
P.O. BOX 7033
INDIANAPOLIS, IN 46207
(317) 636 -1600
L
THE
CCOMRAS
COMPANY
1111 Lincoln Road Mall
Suite 510
Miami Beach, FL. 33139
(305) 532-0433
3" VENT LINE I \
CAPPED FOR FUTURE >
USE (TYPICAL) 1 SEE DN WRAP URAR (TYPICAL) COLUMN 3" --j 4" SANITARY LINE
I CAPPED FOR FUTURE r
4" SANITARY LINE ��' THIRD F1. GW
CAPPED FOR FUTURE O
USE (TYPICAL) I 1
I
1 I; V.T.R. J I L
4" I
I _
SECOND FL i
I
3" VENT LINE J 6'
CAPPED FOR FUTURE THIRD R-
USE (TYPICAL) `� \ `I'
/ 3" VENT LINE 46 DN WRAP AROUND COLUMN
4" SANITARY LINE CAPPED FOR FUTURE
CAPPED FOR AL�RE USE (TYPICAL) SEE STRUCTURAL (TYPICAL)
USE �1 \
6" GREASE WASTE LINE 1
I CAPPED FOR FUTURE I
I USE (TYPICAL) I
I 4" 1
I 3" VENT LINE I
CAPPED FOR FUTURE
WCO USE (TYPICAL) I 4"
I 714C WCO 6" GREASE WASTE LINE CAPPED FOR FUTURE
USE (TYPICAL) � � GROUND FL If 14 woo 4"
6"
7
_ 6• �� 6" GREASE WASTE LINE
CAPPED FOR FUTURE
USE (TYPICAL)
4"
B
SANITARY &GREASE WASTE ISOMETR]C
A
1 2 3 4 5 6 7 8 9 10 11 12 13
MI
3 e
• 1 L 4" V.T.R.
I
4 I
�I
I THIRD FL
3" VENT LINE
CAPPED FOR FUTURE / 4"
USE (TYPICAL.) / WRAP AROUND COLUMN
L
/ SEE STRUCTURAL (TYP.)
4-
I
4" SANITARY LINE I
CAPPED FOR FUTURE I
USE (TYPICAL) I
I
3" VENT LINE I
CAPPED FOR FUTURE I
USE (TYPICAL) Y SECOND FL
4" SANITARY LINE I
CAPPED FOR FUTURE 4• WCO
USE (TYPICAL)
WCO ,
GROUND FL
SAN
4"
USE (TYPICAL) T > 7 )
WCO
J
i WOO
,
GROUND FL
e
4" I � O
J L � V.T.R. I 0-4
I
I I l-+
�
, - I THIRD FL
4" x'
c� \ d-) u E-1
4" 1 1 0
/ 45' DN. WRAP AROUND
3" VENT LINE f COLUMN SEE STRUCT.
CAPP(Ij TORE \ 1 (TYPICAL)
I
4" SANITARY LINE I
CAPPED FOR FUTURE 1
USE (TYPICAL) I
I
3" VENT LINE I
CAPPED FOR FUTURE
USE (TYPICAL) Y SECOND FL G
4" SANITARY LINE
CAPPED FOR FUTURE �--3"
USE (TYPICAL)
WCO
WCO
4"
,, GROUND FL
14 1 15 1 16 1 17 1 18
ra
=)I I I:W
"aMC 11U • HNGIIdHHMG
PLANNING • INIBRIOR DL%GN
5960 S.W. 57TH AVE.
MIAMI, FLORIDA
33143
(305) 666 -5474
E
FAX (305) 666 -4994
A.A.C. 000404
MARIO H. GUTIERREZ, P.E.
FL. MECHANICAL ENGINEER
REG. NO. 0019687
�t
Nelll•
t
ISSUE DATE]
-O
REVISION DATE
C
-a�
08-07-96
PRICING DOC.
- O
- Z
- 1-
- U
_ L,J
_ O
B
_CL
_ Q
CADD FILE NAME
DP500 -RT
DRAWING TITLE
BLDG D PLUMBING
SHEET NUMBER
A
D-P5,00
OF