12-86 70F7-0620 ID■ 0 �om ins ONE imm ME u�■ 0E ME 0 1 2 3 4 5 6 7 8 9 10 11 1 12 13 14 1 15 16 1 17 18 FOOTING SCHEDULE MARK d #9 BOT SIZE x w x THICKNESS REINFORCEMENT REMARKS BOTTOM TOP SHORT BAR LONG BAR SHORT BAR LONG BAR F4.0 E 4'- 0"x4' -0" x 1' -0" 5 #5 5 #5 - - F4.5 4'- 6 "x4'- 6 "x1' -0" 5 #5 5 #5 - - F5.0 5'- 0"x5'- 0 "x1' -0" 6 #5 6 #5 - - F5.5 5'- 6 "x5'- 6"x1' -0" 6 #5 6 #5 - - F6.0 6' -0" x6' -0" x 1' -6" 6 #5 6 #5 - - F6.5 6'- 6"x6' - 6"x1' -6" 6 #5 6 #5 - - F7.0 7'- 0 "x7'- 0 "x2' -0" 8 #6 8 #6 - - c F7.A REVISION DATE 7'- 0"x7'- 0 "x1' -6" 7 #5 7 #5 F7.5 PRICING DOC. 7'- 6"x7'- 6 "x2' -0" 8 #6 8 #6 - - F8.0 8'- 0 "x8'- 0 "x2' -0" #6010" #6010" - - F8.5 8'- 6"x8' - 6"x2' -2" #609" #609" - - .o F8060 B 8'-0"x6'-0"x1'-6" #609" #609" - - _Q F9.0 9' -0" x9' -0" x2' -4" #608" #608" - - F9.5 9'- 6"x9'- 6 "x2' -5" #608" #608" DRAWING TITLE F9040 FOOTING SCHED. & DTLS. 9'- 0"x4'- 0 "x1' -0" #608" #608" - - 58.01 OF F10.0 0' -0 "x10'- 0 "x2' -6" #608" #608" - - F10.5 0' -6" x10' - 6"x2' -10" #607" #607" - - F10070 10'- 0 "x7'- 0 "x2' -0" #6010" #6010" - - F11.0 1 1' -0 "x11'- 0 "x2' -9" 607" 6 ®7" - - F11.5 1' -6 "x11'- 6 "x3' -0" #709" #709" - - F11060 11'-0"x6'-0"x2'-0" #6010" #6010" - - F12.0 2' -0 "x12'- 0 "x3' -0" #709" #709" - - F12.5 2' -0 "x12'- 0 "x3' -1" #8011" #8011" F12050 12'- O "x5'- 0"x1' -6" 12 #5 5 #5 F13.0 3' -0 "x13'- 0 "x3' -2" #8011" #8011" F9060 9' -0" x6' -0" x2' -7" 7 #8 6 #8 F12080 12'- 0 "x8'- 0 "x3' -0" 10 #9 6 #9 10 #9 6 #9 F13070 13'- 0 "x7'- 0"x2' -0" #6010" #6010" F13080 13'- 0 "x8'- (1'x2' -0" #6010" #6010" F14120 4' -0" x 12' -0" x3' -0" #709" #709" F16060 16'- 0 "x6'- 0 "x3' -8" 14 #10 6 #10 - - F16080 16'- 0 "x8'- 0 "x3' -8" 14 #10 6 #10 14 #10 F23016 3' -0" x 16' -0" x4' -0" 14#10 #4010" 10 #8 F1 831 OE 18'-3"xl 0'- 6 "x2' -6" 18 #8 10 #8 10 #8 F90172 17'- 2"x9' -0" x2' -4" 17 #8 7 #8 17#8 7 #8 WF -16 CONT. 16"x12" - 2 #5 - WF-24SF CONT. 24x2' -7" - 3#8 3#8 STB -1* CONT.x3'- 0 "x3' -0" ** 6 #9 ** 6 #9 STRAP FOOTING * ADD 2 #5 INTERMEDIATE BARS EA. FACE ** PROVIDE #3 TIES 0 12" O.C. 0 U U Z 0 U L 18' -0" 1' -g' L 7' -4" L 2' -8" L 6' -4" COMBINED FOOTING A GRID LINES U & 17.3 T BLDG. "C" 4 5 #9 BOT ° d d d a ° d #9 BOT 4 d ° d #9 X12 T.& B. < If L. 16X16 E COL. 16X16 (305) 666 -5474 E FAX (305) 666 -4994 COMBINED FOOTING A GRID LINES U & 17.3 T BLDG. "C" 4 5 #9 BOT ° d d d a ° d #9 BOT 4 d ° d d d ° ° (305) 666 -5474 K**__2 SECTION S8.01 SCALE:3 /8 " =1' -0" J GRADE EL. 4#5 80T b N 4' -0" K**_3 SECTION S&01 SCALM /4 "=1' -0" GENERAL STRUCTURAL 1. GENERAL NOTES A. UNLESS SHOWN OR NOTED OTHERWISE ON THE DRAWINGS OR IN THE SPECIFICATIONS. THE FOLLOWING NOTES SHALL APPLY TO MATERIALS LISTED HERINAFTER FOR USE IN THIS PROJECT. B. ALL ELEVATIONS ARE REFERENCED TO 0' -0" =11.35 N.G.V.D. 2. DESIGN CRITERIA A. GENERAL DESIGN LIVE LOAD ROOF --------------------------- - - - - -- 30 PSF OVERALL FLOOR LOAD ------------- - - - - -- 80 PSF LOBBIES ------------------------ - - - - -- 100 PSF CORRIDORS ---------------------- - - - - -- 100 PSF MECHANICAL AND KITCHEN AREAS --- - - - - -- 150 PSF STORAGE ------------------------ - - - - -- 125 PSF B. SUPERIMPOSED DEAD LOAD PARTITIONS --------------------- - - - - -- 20 PSF MISC --------------------------- - - - - -- 10 PSF REFER TO STRUCTURAL PLANS FOR ADDITIONAL CONCENTRATED DEAD LOADS. C. WIND LOAD IN ACCORDANCE WITH THE 1994 SOUTH FLORIDA BUILDING CODE AND ANSI /ASCE 7 -93 STANDARD " MINIMUN DESIGN LOADS FOR BUILDINGS AND STRUCTURES. BASIC WIND SPEED V = 110 MPH BUILDING LOCATION - -- HURRICANE OCEAN LINE BUILDING CLASSIFICATION - - -- I IMPORTANCE FACTOR I = 1.05 EXPOSURE CATEGORY - - - - - -- C 3. SOIL STATEMENT: FOUNDATION INVESTIGATION AND RECOMMENDATIONS BY PSI INC. (PROJECT NO. 397 - 55076 -02, DATED 11/14/95, INDICATE SANDY LIMESTONE WITH A SAFE BEARING RESISTANCE OF 5 K.S.F. BOTTOM OF ALL FOOTINGS MUST BEAR ON EXISTING LIMESTONE. CONTRACTOR MUST FAMILIARIZE HIMSELF WITH THE REFERENCED GEOTECHNICAL REPORT. FOOTINGS FOR THIS PROJECT HAVE BEEN DESIGNED TO COMPLY WITH SAID REPORT. 4. CONCRETE: A. COMPRESSIVE STRENGTH OF CONCRETE AT 28 DAYS: COLUMN (UNLESS NOTHERWISE ON SCHEDULE)- 5,000 P.S.I. BEAMS (U.N.0) -------------------- - - - - -- 5,000 P.S.I. ELEVATED SLABS ------------------- - - - - -- 4,000 P.S.I. SLABS ON GRADE ------------------- - - - - -- 3,000 P.S.I. FOOTINGS ------------------------- - - - - -- 3,000 P.S.I CONCRETE WALLS ------------------- - - - - -- 4,000 P.S.I. SHEAR WALLS ---------------------- - - - - -- 5,000 P.S.I. ALL OTHER CONCRETE --------------- - - - - -- 3,000 P.S.I. B MAXIMUM SLUMP (U.O.N.): 4 7+ 1" C TESTS: A MINIMUM OF FIVE CONCRETE SPECIMENS SHALL BE TAKEN FROM EACH 50 CU. YDS. OR PORTION THEREOF. SPECIMENS SHALL BE TESTED ACCORDING TO ASTMC -39, ONE AT THREE DAYS, ONE AT 7 DAYS AND THREE AT 28 DAYS. NOTE: IF ONE OR MORE OF THE FIRST TWO CYLINDERS BROKEN AT 28 DAYS FAILS TO MEET SPECIFIED STRENGTH, HOLD THE THIRD ONE AND NOTIFY OUR OFFICE. D) COVER: CONCRETE DEPOSITED AGAINST THE GROUND ---- - - - - -- 3" FORMED CONCRETE IN CONTACT WITH THE GROUND - -- 2" BEAMS AND COLUMNS------------------------- - - - - -- 1-1/2" SLABS AND WALLS----------------------------- - -3/4" ALL CONCRETE SLABS EXPOSED TO THE ELEMENTS MUST EITHER BE SEALED AFTER POURING OR INTEGRALLY WATERPROOFED IN THE MIX IN ORDER TO PREVENT WATER OR MOISTURE INTRUSION. COLUMNS AND WALL BELOW GRADE MUST BE PROTECTED CONTINUOUSLY WITH A WATERPROOFING MEMBRANE. CRACKS IN CONCRETE ARE TO BE ANTICIPATED. G.C. SHALL BE RESPONSIBLE FOR SEALING AND FILLING ALL CRACKS. G.C. SHALL SUBMIT TO ENGINEER, IN WRITING, LOCATION AND DESCRIPTION OF ALL CRACKS AND PROPOSED METHOD FOR REPAIRS OF SAID CRACKS PRIOR TO REPAIRS. 5. REINFORCING STEEL: A REINFORCING BARS MUST CONFORM WITH ASTM A -615, GRADE 60. B WELDED WIRE FABRIC MUST CONFORM WITH ASTM A -185 AND SUPPORTED ON SLAB BOLSTERS SPACED AT 3' -O" MAXIMUM ON CENTER. C) FABRICATION AND DETAILING ACCORDING TO ACI -315. D) ALL ACCESSORIES TO HAVE UPTURNED LEGS AND BE PLASTIC- DIPPED AFTER FABRICATION. 6. PRECAST PRESTRESSED CONCRETE: A) ALL PRESTRESSED CONCRETE MEMBERS SHALL BE DESIGNED, FABRICATED AND ERECTED AS PER THE SOUTH FLORIDA BUILDING CODE AND ACI -318. SUBMIT STRUCTURAL SUBMISSIONS FOR OUR REVIEW AS AN INDICATION THAT OUR INTENT HAS BEEN UNDERSTOOD AND THAT THE SPECIFIED CRITERIA HAS BEEN USED. STRUCTURAL SUBMITTALS SHALL INCLUDE COMPONENT DETAILS, CALCULATIONS, AND FABRICATION AND ERECTION DRAWINGS. ALL SUBMITTALS SHALL IMPRESSED SEAL AND SIGNATURE OF THE SPECIALTY ENGINEER WITH FLORIDA REGISTRATION. PRESTRESSED CONCRETE SUPPLIER MUST BE RESPONSIBLE FOR THE INSTALLATION OF THE PRESTRESSED CONCRETE MEMBERS AND MUST ALSO HAVE MINIMUM OF FIVE YEARS OF LOCAL EXPERIENCE IN 'THE FABRICATION AND INSTALLATION OF SAID MEMBERS. B) PRESTRESSED JOISTS WITH COMPOSITE TOPPING SHALL BE DESIGNED FOR A SUPERIMPOSED LOAD AS SHOWN IN PLANS. SPACE JOISTS TO CLEAR ALL ITEMS SHOWN IN ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS AND THOSE SUPPLIED BY OTHER SUBCONTRACTORS. C) SOFFIT BEAM CALCULATIONS MUST BE SUBMITTED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER FOR REVIEW FOR COMPLIANCE WITH DESIGN LOADINGS. D) THE SPECIALTY ENGINEER RESPONSIBLE FOR THE STRUCTURAL DESIGN OF THE PRECAST PRESTRESSED CONCRETE JOISTS AND SOFFIT BEAMS ALSO BE RESPONSIBLE FOR THE FABLICATION OF THESE STRUCTURAL ELEMENTS AND THE PREPARATION OF THE SHOP DRAWING,SHORING AND ERECTION DRAWING. THE SAME SPECIALTY ENGINEER SHALL SEE THAT THE ERECTION OF THE JOISTS, THE SOFFIT BEAMS, THE DECKING AND FORMWORK IS INSTALLED AND ERECTED AS REQUIRED TO MAKE THE SYSTEM WORK IN ACCORDANCE WITH HIS DESIGN. PRIOR TO THE CONCRETE BEING POURED ON THE SITE THE SPECIALTY ENGINEER SHALL FURNISH THE GENERAL CONTRACTOR AND THE ENGINEER OF RECORD WITH A SEALED LETTER ATTESTING TO THE FACT THAT HE HAS INSPECTED THE SHORING AND FOUND IT TO MEET HIS REQUIREMENTS AS SHOWN IN THE SHORING DRAWING. NOTES E) SOFFIT BEAMS: CONTACT AREAS BETWEEN PRESTRESSE AND POURED IN PLACE CONCRETE SHALL BE CLEAN, FREE OF LAITANCE AND INTENTIONALLY ROUGHENED TO A FULL AMPLITUDE OF APPROXIMATELY 114. 7. STRUCTURAL STEEL: A) CONFORMING TO ASTM A -36. STEEL TUBE COLUMNS CONFORMING TO ASTM A -500, GRADE B. B) BOLTS CONFORMING TO "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A -325 AND ASTM A -490 BOLTS ". C) ALL EXPOSED STEEL MEMBERS (INCLUDING INSERTS AND CONNECTORS) TO BE HOT- DIPPED GALVANIZED. ALL OTHERS TO HAVE A MINIMUM 1.5 MIL OF RUST - INHIBITING PAINT. TOUCH -UP AS REQUIRED AFTER ERECTION. D) FABRICATION AND ERECTION ACCORDING TO THE LATEST AISC SPECIFICATIONS. E) ALL WELDING TO BE PERFORMED BY CERTIFIED WELDERS IN COMPLIANCE WITH AWS D- 1.1 -77. ELECTRODES TO COMPLY WITH ASTM A -233 OR A -316 STORED AS PER AWS REQUIREMENTS. STORED AS PER AWS REQUIREMENTS. 8. MASONRY WALLS: A) MASONRY SHOWN IS NON- BEARING AND MUST BE ERECTED AFTER THE STRUCTURE ABOVE BEEN ERECTED AND ANTICIPATED DEFLECTION HAS OCCURRED. B) MORTAR MUST CONFORM WITH ASTM C -270, TYPE M (2,500 P.S.I.). F'M OF BLOCK UNITS = 2,500 P.S.I. C) PROVIDE STANDARD DUROWALL REINFORCING EVERY OTHER COURSE AND LAP AROUND CORNERS AND WALL INTERSECTIONS WITH PREFABRICATED "L" AND "T" CORNER SECTIONS. D) LAP ALL VERTICAL BARS 48 BAR DIAMETERS. FILL SPECIFIED CELLS WITH 3,000 P.S.I. CONCRETE PUMP MIX CONSOLIDATED IN MAXIMUM HEIGHTS OF FOUR FEET (ALTHOUGH WALL MAY BE ERECTED HIGHER AT THAT POINT). PROVIDE CLEAN -OUT HOLES AT BOTTOM OF EACH REINFORCED CELLNTS AS REQUIRED. ALL SHOP DRAWINGS, PRIOR TO BEING SUBMITTED TO OUR OFFICE, MUST BE STAMPED BY BOTH THE ARCHITECT AND THE G.C. AS EVIDENCE OF THEIR PREVIOUS REVIEW. UNAUTHORIZED DUPLICATION OF OUR PLANS TO BE . PRESENTED AS PART OF THE SUBMITTAL, IS STRICTLY FORBIDDEN. B) SUBMIT LABORATORY REPORTS FOR ITEMS 2 AND 5. 9. SOIL COMPACTION: FILL AND BACKFILL UNDER CONCRETE SLABS ON GRADE MUST BE COMPACTED TO A MINIMUM OF 95% OF THE MAXIMUM DENSITY AT OPTIMUM MOISTURE AS DETERMINED BY THE MODIFIED PROCTOR TEST (ASTM D -1557, METHOD D) 10. SLABS ON GRADE: TO BE PLACED ON CLEAN, NON- ORGANIC GRANULAR FILL ON 8 -MIL VISQUEEN VAPOR BARRIER AND IN A "CHECKERBOARD" SEQUENCE, EACH SEGMENT OF WHICH IS NOT TO EXCEED A MAXIMUM AREA OF 625 SQ. FT., OR 30 LINEAR FEET IN ANY DIRECTION AND AT ALL COLUMN LINES. PREMOLDED METAL KEYED JOINTS (FULL SLAB THICKNESS) MAY ALSO BE USED. CUT WIRE FABRIC AT ALL JOINTS. 11. APPROVALS: A) SUBMIT SHOP DRAWINGS FOR ITEMS 3 AND 4 ABOVE. SUBMIT ONE PRINT AND ONE SEPIA OF EACH. CONTRACTOR WILL ISSUE PRINTS AS REQUIRED. ALL SHOP DRAWINGS, PRIOR TO BEING SUBMITTED TO OUR OFFICE, MUST BE STAMPED BY BOTH THE ARCHITECT AND THE G.C. AS EVIDENCE OF THEIR PREVIOUS REVIEW. UNAUTHORIZED DUPLICATION OF OUR PLANS TO BE PRESENTED AS PART OF THE SUBMITTAL, IS STRICTLY FORBIDDEN. B) SUBMIT LABORATORY REPORTS FOR ITEMS 2 AND 5. 12. COORDINATION: COORDINATE ALL DIMENSIONS, ELEVATIONS, OPENINGS AND DETAILS WITH ARCHITECTURAL, ELECTRICAL AND MECHANICAL DRAWINGS. REPORT ANY CONFLICTS OR DISCREPANCIES TO OUR OFFICE. IN CASE OF CONFLICTS OR DISCREPANCIES, CONTRACTOR MUST ASSUME COSTLIER SOLUTION DURING BIDDING UNLESS CLARIFICATION IS OBTAINED IN WRITING FROM THE ARCHITECT. 13. SHORING, RE- SHORING AND SAFETY PRACTICES: ALL SHORING AND RE- SHORING IS TO BE DESIGNED AND SPECIFIED BY A FLORIDA REGISTERED ENGINEER WHO SPECIALIZES IN FORMWORK DESIGN AND WHO HAS BEEN HIRED BY THE GENERAL CONTRACTOR. SHORING ENGINEER SHALL SUPERVISE ALL SHORING AND RE- SHORING INSTALLATIONS AND SHALL CERTIFY TO OUR OFFICE THEIR ADEQUACY PRIOR TO ANY POUR. OUR OFFICE DOES NOT POSSES, NOR PRESUMES TO POSSES, ANY KNOWLEDGE OR EXPERTISE IN MATTERS RELATING TO JOB SAFETY, OSHA OR LABOR LAW REQUIREMENTS FOR A CONSTRUCTION PROJECT. SAFETY AND COMPLIANCE WITH OSHA AND LABOR LAWS IS THE ABSOLUTE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THOSE CONSULTANTS HE HIRES TO ADDRESS THEM. 14. TIE COLUMNS: PROVIDE 8"X12" (MIN.) TIE COLUMNS REINF. W/ 4 #5 VERTICAL AND #3 TIES 0 8" O.C. SPACE 0 15' O.C. OR LESS FOR ALL NON BEARING CONCRETE BLOCK WALLS IN ORDER NOT TO EXCEED UMBRACED AREAS OF MAX. 240 SQ. FT. EXIST. TIE COLUMNS SHALL BE ATTACHED TO SOFFIT BEAMS ABOVE WITH L4 7X4 7X3 /8 "X10" WITH 2- 1/2" DIA. WELDED ANCHORS EMBEDED IN SOFFIT BEAM. PROVIDE BY SOFFIT BEAM MANUFACTURER. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 M ,%AiL \�U�V_ ii NATIONAL CITY CENTER P.O. BOX 7033 INDIANAPOLIS, IN 46207 (317) 636 -1600 10 K THE CCOMRAS COMPANY 1111 Lincoln Road Mall Suite 510 Miami Beach, FL. 33139 (305) 532 -0433 I o w x H H o G F SO I�T�IIL'a ARCIGTE=U - ENGINEERING PLANNING - INTERIOR DESIGN 5960 S.W. 57TH AVE. MIAMI, FLORIDA 33143 (305) 666 -5474 E FAX (305) 666 -4994 A.A.C. 000404 EUGENIO M. SANTIAGO, P.E. EGISTERED ENGINEER (CIVIL /STRUCT. FL. REG. NO. 19673 . % r J r ISSUE DATE -o -o c REVISION DATE PRICING DOC. - O _z _ Ld .o B :D:f _Q CADD FILE NAME S801 -RT DRAWING TITLE FOOTING SCHED. & DTLS. SHEET NUMBER A 58.01 OF