Loading...
12-86 70F7-0379 10 11 12 13 14 15 16 17 18 S�MON PROPERTY A Al A Al D A Al 8"X5' CONC. CAP GROUP M W/ 2 #5 CONT. COL. COL. COL. COL. A Al CONC. COL. CONC. COL. NATIONAL CITY CENTER 1' -4" l' -4' 5'X8" CONC. CAP P.O. BOX 7033 01 BLDG. LINE BLDG. LINE PARAPET WITH (@ ELEV. 52.0 ONLY) ° W/ 2 #5 CONT. INDIANAPOLIS, IN 46207 • • 8"X8" CONC. CAP 1._4„ A Al 1,_4» 0,00 (317) 636 -1600 BLDG. W/ 2 #5 CONT. SLA REINF. COL. SLAB REINF. +16' -0" 8" CMU WALL SLA REINF. ° ADD'L TOP REINF. AT EL. +52' -0" SEE PLAN +32' -0" 1' -4" SEE PLANS. SEE PLAN +16' -0" BLDG. w SEE PLAN. O LINE CONC. COL., 3 #5 LINE o SLAB REINF. TIME j, BEYOND +52' -0" BLDG. LINE SEE PLAN +52' -0" L .0 1, 7 - OMIT PARAPET ®RAS FOR REINF. +42' -0" � ° SEE NOTES ° ° ° �o ° AT EL. + 32' -0" • °° COMPANY w w w #3@6 ° ° ° ° 2 5 1 #5 Uj 1111 Lincoln Road Mall ° I quite 510 d ° 1 E. CONC. BEAM, I Miami Beach, Fl. 33139 ° ° ° CONC. BEAM, _ ° ° C) 6 LIJ ° ° FOR REINF. ° 6 ° FOR REINF. o I (30J� 532-0433 � AND SIZE, SEE BM. � AND SIZE, SEE BM. 1 Uj C) a° CONC. BEAM, SCHED. 2 #5 2# SCHED. K ° FOR REINF. AND SIZE, SEE BM. ° ° P.C. JOIST DOES NOT SCHED. ° a ° ° ° CONC. COL. CORCREINF.M (CURVED) ENGAGE GRID LRNES 6 & 7 Ld F 2 #6 4 2 #6 #3 ®24' AND SIZE, SEE BM. SEE PLANS CONC. COL., COL. SCHED. 8„ 8„ 0 ;11 8� 8» 8» 81 $ 8 r t J ` TIN K`_2�SECTION 3 SECTION 3A SECTION r4_'�SECTION � SEC 0 �.12SCALE:3 /4 " =1' -0" S5.02 SCALE:3 /4 " =1' -0" S�.12SCALE:3 /4 " =1' -0" S�.12SCALE:3 /4 " =1' -0" �.12SCALE:3 /4 " =1' -0" j I o w A Al A Al CONC. COL. SEE COL. Al B FOR HANDRAILS. B BLDG. LINE ,_ » 8"X8" CONC. CAP A Al CONC. COL. 1 4 4 W/ 2 #5 CONT. COL. TCMU PARAPET COL. 10' -0" N.T.S. x BLDG. LINE � 4' -0" 4' -0" ® ELEV. +32' -0" ONLY BLDG. LINE EI 1' 4" 6' -0" N.T.S. FOR CMU @ ELEV. +16' -0" 1' -4" 8" MASONRY WALL H COL. � C L. SEE ARCH. SEC. 2 \A —A5.01 0 - SEE PLAN REINF. +32' -0" • ° ', ;�, ADD'L TOP REINF. +32' -0" I SLAB REINF. BLDG. SEE PLAN. SEE PLAN LINE #4010 "O.C. SLAB REINF. ADD'L TOP REINF. � +16' -0" P.C. JTS. SEE, PLAN TOP & BOT. _ SEE PLAN 8" X8" CONC. CAP SEE PLAN. J w +16- 0 ____________ _ o W/ 2 #5 CONT. SLAB REINF. 0 z cn +42' -0„ w ° ° ° _316 1 1 SEE PLAN _ `� `� ° ° CO I 0- 0 - ° a °d ° 4 °° ° ° Z ° • 6 ° I o o a ° a 6 ° ^° w o 1 w w G I +52' -0„ w w F� Co a° ° W Z G 1 #5 a s ° o� w ° a 2 #5 ° Cw �° o Q _I W/ 2 #4 CONT.T.& BT. _ VA o ° P.C.JOIST ° I CV ° o w DOES NOT ENGAGE ° ° �' � w #3 ®12" STIRRUPS ° 1 ww °a° °° CURVED BM BETWEEN o0 o m g" „ ������������ 2 5 a o c 1 #5 1 #5 LINE 6 & 7, SEE PLAN. N FOR REINF. ° ° CONC. BEAM, iiiiiiiiiiii '�' ° a ° ° AND SIZE, SEE BM. m AND SIZE SEE BM. P.C. JTS.SEE PLAN ° P.C. JTS. SEE PLAN 11 4 w ° SCHED. —� — / / / / / / / / / / / , , / , , , SCHED. w o ° FORCREINF. EM� ° SOFFIT BEAM,FOR REINF. ° 1 #5 ° SOFFIT BEAM,FOR REINF. 2 #6 ° AND SIZE, SEE BM. wU' ° AND SIZE, SEE BM, SCHED. WOILIEI�IERG AND SIZE, SEE BM, AII,�IAI�IE7G SCHED. SCHED. CONC. BEAM, ° 8" 8� 8 12„ P.C. JTS.SEE PLAN 4' -0" JST. SPC. ° CURVED CONC. BEAM, � I FOR REINF. AND AND SIZE, SEE BM. SOFFIT BEAM, AS REQ D # TIES #3 @ 30 SCHED. PARTNERS ERS SEE PLAN & BEAM SCHED. FOR REINF. 2 6 CONC. COL. AND SIZE, SEE BM, SCHED. » ARCHIT6CfURH • BNGINEHRINc 4 PLANNING •INTERIOR DESIGN 8" 8" 5960 S.W. 57TH AVE. MIAMI, FLORIDA 33143 3\A -B5.01 (305) 666 -5474 5 SECTION 6 SECTION 2�A -A5.o1 � SECTION 8 SECTION E ('4A SECTION FAX (305) 666 -4994 S5.02 SCALE:3 /4 " =1' -0" S5.02 SCALE:3 /4 " =1' -0" S5.02 SCALE:3 /4 " =1' -0" S�.02SCALE:3 /4 " =1' -0" �.02SCALE:3 /4 " =1' -0" A.A.C. 000aoa EUGENIO M. SANTIAGO, P.E. 8 "X8" CONC. CAP 9' -3" RADIUS 9' -3" RADIUS EGISTERFL ENGINEER REG. NO. 19`673STRUCT. f — W/ 2 #5 CONT. Al CO . ROUND CONC. COL: „3 °•° COL. COL. CONC. COL., BEYOND ` • . ADD'L TOP REINF. ' D SEE PLAN. � s � SLAB REINF. ( , SEE PLAN. SLAB REINF. SEE PLAN r - ADD'L TOP REINF. N k SLAB REINF. ':- cv „ » ••.......... +16'- 0 +32'-Y' SEE PLAN. SEE PLAN. ,_ „ +42 —0 +52 0 ISSUE DATE d° ° ° ° ° ° - d ° ° ° ° ° ° ° • ° - lip ° Z ° ° ° ° ° 1f - CONC. BEAM, ° 0- W ° � - Cq FOR REINF. ° ° w o o I ° C : ° REVISION DATE AND SIZE, SEE BM. I CURVED CONC. BEAM, N I 1 j o : 08 — — 1 SCHED. FOR REINF. w - CD N 1 6 ° PRICING DOC. #4010 "O.C. a AND SIZE, SEE BM. w w 8" WIDE CURVED ° TOP & BOT. ° ° SCHED. e P.C. JOIST DOES NOT BEAM' - . . CANT. BEAM BEYOND EA. WAY. � � ENGAGE CURVED BM SCHEDEINF., SEE BM. : Z 8 WIDE BTW GRID LINES 6 & 7 - SEE PLAN ° CURVED BEAM o ° - U ° ° SEE PLANS w B SLOPE ° 0 "CLR• 14" DIA. COL. D : � ° D ° d ° .Q 4 8„ 8„ ° ROUND CONC. COL. CADD FILE NAME 16 x 16 CONC. S502 -RT 6,_9„ 7„ COL. DRAWING TITLE SECTIONS AND DETAILS E TIN ri SECTION l 2 SECTION SHEET NUMBER 9 SECTION �o S C 0 A S5.02 SCALE:3 /4 " =1' -0" S�.02SCALE:3 /4 " =1' -0" S5.02 SCALE:3 /4 " =1' -0" S�.02SCALE:3 /4 " =1' -0" r S5,02 1 2 3 4 5 6 '7 8 9 10 11 12 13 14 15 16 17 OF