12-86 70F7-0379 10 11 12 13 14 15 16 17 18 S�MON
PROPERTY
A Al A Al D
A Al 8"X5' CONC. CAP GROUP
M W/ 2 #5 CONT. COL. COL.
COL. COL. A Al
CONC. COL. CONC. COL. NATIONAL CITY CENTER
1' -4" l' -4' 5'X8" CONC. CAP P.O. BOX 7033 01 BLDG. LINE BLDG. LINE
PARAPET WITH (@ ELEV. 52.0 ONLY) °
W/ 2 #5 CONT. INDIANAPOLIS, IN 46207
• •
8"X8" CONC. CAP 1._4„ A Al 1,_4» 0,00 (317) 636 -1600
BLDG. W/ 2 #5 CONT. SLA REINF. COL. SLAB REINF. +16' -0" 8" CMU WALL SLA REINF. ° ADD'L TOP REINF.
AT EL. +52' -0" SEE PLAN +32' -0" 1' -4" SEE PLANS. SEE PLAN +16' -0" BLDG. w SEE PLAN.
O LINE CONC. COL., 3 #5 LINE o SLAB REINF. TIME
j, BEYOND +52' -0" BLDG. LINE SEE PLAN +52' -0" L .0 1, 7 -
OMIT PARAPET ®RAS
FOR REINF. +42' -0" � °
SEE NOTES ° ° ° �o ° AT EL. + 32' -0" • °° COMPANY
w w w #3@6
° ° ° ° 2 5 1 #5 Uj 1111 Lincoln Road Mall
° I quite 510
d ° 1 E. CONC. BEAM, I Miami Beach, Fl. 33139
° ° ° CONC. BEAM, _ ° °
C) 6 LIJ ° ° FOR REINF. ° 6 ° FOR REINF. o I (30J� 532-0433
� AND SIZE, SEE BM. � AND SIZE, SEE BM. 1 Uj
C) a° CONC. BEAM, SCHED. 2 #5 2# SCHED.
K ° FOR REINF.
AND SIZE, SEE BM. ° ° P.C. JOIST DOES NOT
SCHED. ° a ° ° ° CONC. COL. CORCREINF.M (CURVED) ENGAGE GRID LRNES 6 & 7 Ld F
2 #6 4 2 #6 #3 ®24' AND SIZE, SEE BM. SEE PLANS
CONC. COL., COL. SCHED.
8„ 8„ 0 ;11 8� 8» 8» 81 $ 8
r
t
J `
TIN K`_2�SECTION 3 SECTION 3A SECTION r4_'�SECTION � SEC 0
�.12SCALE:3 /4 " =1' -0" S5.02 SCALE:3 /4 " =1' -0" S�.12SCALE:3 /4 " =1' -0" S�.12SCALE:3 /4 " =1' -0" �.12SCALE:3 /4 " =1' -0"
j I o
w
A Al
A Al CONC. COL.
SEE COL. Al B FOR HANDRAILS. B BLDG. LINE ,_ » 8"X8" CONC. CAP A Al
CONC. COL. 1 4 4 W/ 2 #5 CONT.
COL. TCMU PARAPET COL.
10' -0" N.T.S. x
BLDG. LINE � 4' -0" 4' -0"
® ELEV. +32' -0" ONLY BLDG. LINE EI
1' 4" 6' -0" N.T.S. FOR CMU @ ELEV. +16' -0" 1' -4" 8" MASONRY WALL
H COL. � C L. SEE ARCH. SEC. 2 \A —A5.01 0
- SEE PLAN REINF. +32' -0" • ° ', ;�, ADD'L TOP REINF. +32' -0" I SLAB REINF.
BLDG. SEE PLAN. SEE PLAN
LINE #4010 "O.C. SLAB REINF.
ADD'L TOP REINF. � +16' -0" P.C. JTS. SEE, PLAN
TOP & BOT. _ SEE PLAN
8" X8" CONC. CAP SEE PLAN. J w +16-
0
____________ _ o W/ 2 #5 CONT. SLAB REINF. 0
z cn +42' -0„ w ° ° ° _316 1
1 SEE PLAN _ `� `�
° ° CO I 0- 0 - ° a °d ° 4 °° ° ° Z ° •
6 ° I o o a ° a 6 ° ^°
w o 1 w w
G I +52' -0„ w w F� Co a° ° W Z G
1 #5 a s ° o� w ° a 2 #5 ° Cw �°
o Q _I W/ 2 #4 CONT.T.& BT. _ VA
o ° P.C.JOIST ° I CV ° o w
DOES NOT ENGAGE ° ° �' � w #3 ®12" STIRRUPS ° 1 ww °a°
°° CURVED BM BETWEEN o0 o m g" „ ������������ 2 5 a o c
1 #5 1 #5 LINE 6 & 7, SEE PLAN. N FOR REINF. ° ° CONC. BEAM, iiiiiiiiiiii '�'
° a ° ° AND SIZE, SEE BM. m AND SIZE SEE BM. P.C. JTS.SEE PLAN ° P.C. JTS. SEE PLAN 11 4
w ° SCHED. —� — / / / / / / / / / / / , , / , , , SCHED. w o ° FORCREINF. EM� ° SOFFIT BEAM,FOR REINF.
° 1 #5 ° SOFFIT BEAM,FOR REINF. 2 #6 ° AND SIZE, SEE BM. wU' °
AND SIZE, SEE BM, SCHED. WOILIEI�IERG
AND SIZE, SEE BM, AII,�IAI�IE7G
SCHED. SCHED. CONC. BEAM,
° 8" 8� 8 12„ P.C. JTS.SEE PLAN 4' -0" JST. SPC. °
CURVED CONC. BEAM, � I FOR REINF. AND
AND SIZE, SEE BM.
SOFFIT BEAM, AS REQ D # TIES #3 @ 30 SCHED. PARTNERS
ERS
SEE PLAN & BEAM SCHED. FOR REINF. 2 6 CONC. COL.
AND SIZE, SEE BM, SCHED.
» ARCHIT6CfURH • BNGINEHRINc
4 PLANNING •INTERIOR DESIGN
8" 8"
5960 S.W. 57TH AVE.
MIAMI, FLORIDA
33143
3\A -B5.01 (305) 666 -5474
5 SECTION 6 SECTION 2�A -A5.o1 � SECTION 8 SECTION
E ('4A SECTION FAX (305) 666 -4994
S5.02 SCALE:3 /4 " =1' -0"
S5.02 SCALE:3 /4 " =1' -0" S5.02 SCALE:3 /4 " =1' -0" S�.02SCALE:3 /4 " =1' -0" �.02SCALE:3 /4 " =1' -0" A.A.C. 000aoa
EUGENIO M. SANTIAGO, P.E.
8 "X8" CONC. CAP 9' -3" RADIUS 9' -3" RADIUS EGISTERFL ENGINEER REG. NO. 19`673STRUCT.
f — W/ 2 #5 CONT. Al
CO . ROUND CONC. COL: „3
°•° COL. COL.
CONC. COL.,
BEYOND ` • .
ADD'L TOP REINF. '
D
SEE PLAN. � s �
SLAB REINF. ( ,
SEE PLAN.
SLAB REINF.
SEE PLAN r -
ADD'L TOP REINF. N
k SLAB REINF. ':-
cv „ » ••..........
+16'- 0 +32'-Y' SEE PLAN. SEE PLAN. ,_ „
+42 —0 +52 0 ISSUE DATE
d° ° ° ° ° ° - d ° ° ° ° ° ° ° • ° - lip
° Z ° ° ° ° ° 1f -
CONC. BEAM, ° 0- W ° � - Cq
FOR REINF. ° ° w o o I ° C : ° REVISION DATE
AND SIZE, SEE BM. I CURVED CONC. BEAM, N I 1 j o : 08 — —
1 SCHED. FOR REINF. w -
CD N 1 6 ° PRICING DOC.
#4010 "O.C. a AND SIZE, SEE BM. w w 8" WIDE CURVED
° TOP & BOT. ° ° SCHED. e P.C. JOIST DOES NOT BEAM' -
. .
CANT. BEAM BEYOND EA. WAY. � � ENGAGE CURVED BM SCHEDEINF., SEE BM. : Z
8 WIDE BTW GRID LINES 6 & 7
- SEE PLAN ° CURVED BEAM
o ° - U
°
° SEE PLANS w
B SLOPE ° 0 "CLR• 14" DIA. COL. D : �
°
D
° d °
.Q
4 8„ 8„
° ROUND CONC. COL. CADD FILE NAME
16 x 16 CONC. S502 -RT
6,_9„ 7„ COL.
DRAWING TITLE
SECTIONS AND DETAILS
E TIN ri SECTION l 2 SECTION SHEET NUMBER
9 SECTION �o S C 0 A
S5.02 SCALE:3 /4 " =1' -0" S�.02SCALE:3 /4 " =1' -0" S5.02 SCALE:3 /4 " =1' -0" S�.02SCALE:3 /4 " =1' -0"
r
S5,02
1 2 3 4 5 6 '7 8 9 10 11 12 13 14 15 16 17 OF