Loading...
12-86 70F7-0320 no "M ion 1 0 amm Itam ice■ ME o■ 1 2 3 4 5 6 7 BLDG. D THIRD FLOOR F SCALE: 1/16 " =1' -0" RAMING PLAN 1 2 3 4 3 S5.11 3 0.30.60.9 P.2 V8 2 35g" o, -o n • N 7 N _ j m 1 N _ o� 0$ 101 ( .. N 3SB, • `29 i cv 10.4 v 35g,228A , -C ES- o \_ =o T.3 I DN DN ail \ 8 R.6 PR. (S. 2 S.7 7" _ 18' -9" _ SHEARWALL AT STAIR - D2 ST -D2 s io 1 ii iz I is I 14 1 15 is iv is T.8 143' -0" 37' -0" _ 37' -0" M 35' -0" V.9 0.0 0 3SB -31 OA I M �SB -310A ° r m ?� I II a to MI 0 I V) o I II m �9, MI I �� I I - 2.2 II ° I I �s� �I I m M I I I %_Q Ml Im �1 III X01 M low D 3.2 \ =o o I 2 M I I Q, I \ 6" C. P NELS s5.1, o M1I N11 SEE NOTE No. In m v' III M � M ml III 11 �I I II 11 7 I I � - 1 15.1 N1 �I Im 0 I I o N � (D Ito m m I I SEE NOTE No.6 co M I I M cn I N\ N N II �, II ��\ M 16" P.C. JOISTS I �\ SHEARWALL AT I I 11 I - -D-1- 1801 -D, 011 NII W I P M 1 I mI I �I I II III �I I m � \ 6" THK SLAB I N I I 1" EXP. JT. I I �W'YAY'7"_ " B. / 7.1 IM 3S6 -301A 3SB- 01A 3S6 -301A 7.2 I N C) �- (3 i 3 C 3 B -302D m cn M 3SB -303A ° j p 35 9' a° LO - 0 809 JSS- W.9 z ia WA 9.4 3 3B -69 3B-70 36 -7 3B -7 3B-184 i I m CORRIDOR C ID R ( \ I m l M m COR IDOR `r \ /� JANITOR / 1 //� I M N SHEARWALL AT V) 4 r- STAIR -A6 nil I rn 1 n.C. JOIST S5.09 m II N 3e�8, ' NI �G / 1 m P.C. JOIST m En M / `1 "'I I ®5' -6" O.C.(MAX) / 1 �I 1 SEE NOTE No.12 N II II SEE NOTE No.6 i' I n I M I S NOTE No.13 M I I NII NI I m I I N " XP. JT. NI m m MI I" U) I N Lo m l MI I 1 12' P.C. JOISTS 1 r� I �) I �I 12"P.C.JOIST ®5 6" O.C. (MAX) 1 M m @6'-6" O.C. I SEE NOTE No.6 / '`'I I� II II �I I _ o f m CIT N I 11 �- �I SIL 103 PSF. I I m NI N ' - NI M SEE NOTE No.12 "I I m I I Q3 a' INS M i re) 11I II -� SEE NOTE No.13 III I I" EXP. JT. 8 9 10 11 \o i 11.4 �s 12.3 12.7 II I�1 o 4 �-s 13.1 6 �HK',.� o. W 4 ®16 EA•Wp NOTES: 1. 3rd FLOOR SYSTEM CONSISTS OF A 4 1/27 MIN. CONC. SLAB REINF. W/ #3 ®12 O.C. E.W. CENTERED. PRECAST PRESTRESSED JOIST SHALL BE 16" DEEP EXCEPT AS NOTED; SPACING OF JOIST AS NOTED ON PLANS. 2. SUPER IMPOSED LOADS (SIL) 103 PSF EXCEPT AS NOTED. 3. FIRE RATING 2 HOURS. 4. TOP OF CONCRETE SLAB ELEVATION +32' -0" EXCEPT AS NOTED. 5. ELEV.O' -0" = ELEV. 11.00' NVGD. 6. SHEAR FRICTION REINFORCEMENT TYPICAL AT ALL SOFFIT FRAMING INTO SUPPORTS. 7. CONTRACTOR TO COORDINATE THE LOCATION OF ALL NON BEARING CONCRETE BLOCK WALLS WITH THE ARCHITECTURAL DRAWINGS. THEIR ADDITIONAL LOAD (840 LB /LI. FT.) IS IN ADDITION TO THE SUPERIMPOSED LOADS INDICATED IN THE GENERAL STRUCTURAL NOTES (SEE DRAWING S -6.01) PROVIODE DOUBLE PRECAST CONIC. JOISTS UNDER NON BEARING BLOCK WALLS WHERE WALLS RUN PARALLEL TO JOISTS DIRECTION. PROVIDE 2 #5 BARS CONT. BOTTOM WHERE WALLS RUN PERPEND. TO JOISTS DIRECTION. 8. FOR BEAMS SCHEDULE SEE DRAWING S9.02 THRU S9.07 9. FOR COLUMN SCHEDULE SEE DRAWING S8.02 AND S8.03 10. FOR SHEARWALL DETAIL SEE DRAWINGS S6.01 THRU S6.05. 11. FOR TIE BEAMS AND TIE COLUMNS SEE GENERAL STRUCTURAL NOTES ON DRAWING S8.01. 12. TEMP. & CRACK CONTROL REINF. W/ #3012" X6' -0" LONG TOP STAGGER ENDS 1'-0" (TYP. AT ALL SOFFIT BEAMS) KEY PLAN i i j 12 13 14 15 16 1 17 1 18 INATIONAL CITY CENTER P.O. BOX 7033 INDIANAPOLIS, IN 46207 (317) 636 -1600 L rN THE COMll ALAS COMPANY 1111 Lincoln Road Mall Suite 510 Miami Beach, FL. 33139 (305) 532 -0433 F ARC=C= - E NGU400 IMG PLANNING - INTERIOR DWGN 33143 (305) 666 -5474 E FAX (305) 666 -4994 A.A.C. 000404 EUGENIO M. SANTIAGO, P.E. EGISTERED ENGINEER (CIVIL /STRUCT. FL. REG. NO. 19673 .. y ISS � 'DIx7E .Cq c : o� REVISION DATE PRICING DOC. - F- - U _ W CADD FILE NAME DS303 -RT DRAWING TITLE BLDG D 3rd FL FR PL SHEET NUMBER A D -53.03 OF