12-86 70F7-0140
0
ra■
MAN
no
0
ME
ME
ME
ME
v■
1 2 3 4 5 6 7 8 9 10
A A.1 B 1 B.8 C D 5 D.8 E E.6 F.2 F.3 G.2 G.8 H.1 H.2 H.8 I.5 I.7 I.8 J.2 J.6
5.09 S5.16
245' -9"
10' -0" 3' -3" ' -0" 25' -6" 1' -0" ' -0" 15' -9" 10' -11" ' -3" 24' -7" 24' -4" 20' -9" 1' 21' -2" 18' -0" 14' -0" 14' -3" 12' -3"
190' -7"
SHAFT 0 ENING
R -5 ELEVATOR 0 ENING -RSB -1 6„ PRSBP PANELS RS -3
RB 7
1.1 I - I - - - - - -- 7EN
STRUCTURE AB T �HOWN II
FOR CLARITY. II
T 77777
rSEE ENLARGED PLAN.
1 .W. AT STAIR
A
II
5.02 l b
- (BELOW) soh -0"
6" THK SLAB 4 +52' -0" uTOs
W/#5@1 2 T. & B. E.W. - - -
2 I I
S.W. @ S I oz
'b A 1(BELO I SEE NOTE No.12 1
I m
_ -1co
N
I
cl 4 - - _ RSB -5 I RSB -6 SB -7 - -RS -8 - 1 6" P.C. PANELS RSB -14 RSB -15
3 - -- ----- - - - - -� -- -- --
I
- - - - -- = - - - --
N 1 I IIo S.W. 3.1A LOW) - -= --
3.1 �, 1 - I� o
I °I
5 � m ml
S5.02 I I U'
4
N o N MECH. E UIP. 124 P.C. JOISTS
o 1� o (75 PSF s2' -o" 1 I 2
(-')1 1 s
N I a 1- 1 m S5.16
'TO
N I Im I SEE NOTE No.6 I m l "
1 (BEW WjI.P CON RETE WALL �i
RPD-4 - -- RSB -S I- -- -RSB -6 -- -- SB -7- R I `r'
5 o A/C BRACKET SUPPORT (TYP.) II II
I - I % SEE STD. DETAIL.
Im I
1 <52 0'> 1m M 1 24 P.C. JOISTS @ 4?-8"
= I -� I DOUBLE JOIST I I 70' -9"
co
S.W. AT STAIR A -3 I I rn 100 To g1
(BELOW.) I I 1 1 o
RSB -9 11 ME CH I QF IPm I � <70.0'> ml
CD r2
_ _ RSB -10 _-1 _ _ _RSB_ -11 _ RSB -12 _ _ _ RSB_- S Tos I I I S5.09
m -
6 I - - -- - - -- -- - - - - -- - - - - - - E6 27 -- - -
�LnPFQ -11
Lot
`i I
m 2'-� I c S
_�
o OS T� T
LO
1 &4 �' 1 C/) 70'- m 48' -0" Fr -
0 or- TOS t os
RS RSB -1 _ _ _RSB _18 RSB =19 _ _ _ RSB -_ RSB= 21_(HI) _ _ RSB- 2 _ RSB= 23
- - - -- --
8
RSE 16 RSB -17 RSB -18 RSB -1I9 RS -20 (LOW) SB -24 (HI) RSB -25 (HI) RSB -26 RSB -27 RSB -28 (HI)
CMU ALL. m 70' -7 1/2"
o I T I Tos 24" P.C. JOISTS @ 5' -8" �I ITOS
a
co I
N
V) I I I s9' -11 <70.0'> I
T0� I TOS
RSB_29 _ _RSB- 0 _ RSB -31 I __- RSB_32 _ - RSB- 33______�
R -2�
j I.-. 1 1 III ml
/ ,-,1 247 P.C. JOISTS @ 5'-87
�Icv `i11 II
6 THK SLAB j
AIN REINF. #4 @12"
� I
& B. IE.W. STAGG. I I TOS I I I Tos
/ I - - RSB =29 _ _I_ RSB - �0 _ _ _ _ RSB - 31
� -, I I NI
RSB -29
j III I I I I I I col
1 iI S51,3 PLAMIM
N 1 o
ROOF A ELEV. +48'-Y'
/ I N mI ml I I FOR F G PLAN
C.I. . PARAPET / 1 En
M I �I 1 �
EL VARIES. � N / I I I SEE DR ING A -S .04.
j I RSB -29 RSB- 0 RSB -31 I I I I 48 -�
- - - - - -- - -- -- - - - - -J TOS
6 "THK SLAB RSB -64C cn v cv
W/ #4@12 / �, I I Ln
T. & B. W. STAG_ o I I 1 I <41.01>
pry m
M1 I DOUBLE JOIST I I 1
m=_ = = = -J I _I
M
N® I r -I I SB 12 4-,
i RSB -34 T RSB -35 RSB -361 I I RSB -38 1 I RSB -39 RSB -40 RS B-4
---- - - - - - -- -
m IRSB- 5A - - - --
RSB -37
TRUCTURE ABOVE N v ~
o I OT SHOWN FOR o v co °
12.5 CLAR TY. SEE ENLARGED o m
U /
110 � PARTIAL PLAN DETAIL � m � c° /
m BS3. 6 m I
® o/
13 1 RSB =6 = _ = RSB -65= - _ _ = RSB -66 = _ _ = RSB =67 � = R - __ -
1 r RS so' 10" 4'
e• 4 Tos
GA 3 u
S J
roo M 1
o I (3 6 "THK SLAB v~i �1 1 ��R B 4p r
s
- W/ #4 ®12" o �I 1 G 3 \ 1 H.7
co @ T. & B. E.W. STAGG.
® - < +56' -0 "> I I I I // ` S5.17
7 ® SEE NOTE No.6 I 1 13.8 / ` \ 21 \ 4"
S5.03 - - - - - RSB -6 _ _ RSB =67 _ RSB -68 _ J I / / \
14 - - - - - -- - -- - - -- - - - -- r // 1 28',�
1 0 / / / / o / ° S5.03 8 I.2
S. ® (BELOW) cn
- - - -- N �' X11 14.1 ^ /; `��;��� // 2'o I9
h
_ - - - -- 7 0 5 (3
0
CE
ZA 0
- m �.03 T YP. I a - o) Cv/ 4 ° m i rn
S5.04 - .7
A/C BRACKET SUP OR (TY .)
SEE STD. DETAIL. RSB -74
RSB -6 RSB -70 RSB -71 RSB -72 m/ / 6 �6" do/ /
1 2 3 4 5 6 7 8 9 10
11 12 13 I 14 I 15
NOTES: KEY PLAN
1. ROOF SYSTEM CONSISTS OF A 4 1/2" MIN. CONC. SLAB REINF.
W/ #3@12 O.C. E.W. CENTERED.
PRECAST PRESTRESSED JOIST SHALL BE 16" DEEP EXCEPT
AS NOTED; SPACING OF JOIST AS NOTED ON PLANS.
2. SUPER IMPOSED LOADS (SIL) 65 PSF EXCEPT AS NOTED.
3. FIRE RATING 2 HOURS.
4. TOP OF CONCRETE SLAB ELEVATION AS NOTED ON PLAN.
5. ELEV.O' -0" = ELEV. 11.00' NVGD. lip
6. SHEAR FRICTION REINFORCEMENT TYPICAL AT ALL SOFFIT FRAMING
INTO SUPPORTS.
7. CONTRACTOR TO COORDINATE THE LOCATION OF ALL NON BEARING
CONCRETE BLOCK WALLS WITH THE ARCHITECTURAL DRAWINGS.
THEIR ADDITIONAL LOAD (840 LB/L1. FT.) IS IN ADDITION TO THE
SUPERIMPOSED LOADS INDICATED IN THE GENERAL STRUCTURAL
NOTES (SEE DRAWING S -6.01)
PROVIODE DOUBLE PRECAST CONC. JOISTS UNDER NON BEARING
BLOCK WALLS WHERE WALLS RUN PARALLEL TO JOISTS DIRECTION.
PROVIDE 2 #5 BARS CONT. BOTTOM WHERE WALLS RUN PERPEND.
TO JOISTS DIRECTION.
8. FOR BEAMS SCHEDULE SEE DRAWING S9.02 THRU S9.07
9. FOR COLUMN SCHEDULE SEE DRAWING S8.02 AND S8.03
10. FOR SHEARWALL DETAIL SEE DRAWINGS S6.01 THRU S6.05.
11. FOR TIE BEAMS AND TIE COLUMNS SEE GENERAL STRUCTURAL
NOTES ON DRAWING S8.01.
12. TEMP. & CRACK CONTROL REINF. W/ #3 @12 "X6' -0" LONG TOP
STAGGER ENDS 1' -0" (TYP. AT ALL SOFFIT BEAMS)
BLDG. A ROOF FRAMING PLAN
SCALE:1 /16 " =1' -0"
is 17 1 1e SdMON
:61
SHE RWALL AT Tos
STAR D -2
- 59' -0" M
IN Uri Mm
6" C NC. SLAB TOP
W/ 4@ 10" O.C. NATIONAL CITY CENTER
Tn P & B OT. P.O. BOX 7033
AY, STAGG. INDIANAPOLIS, IN 46207
RSB - 2 (317) 636 -1600
M I - //�� 110 os
co I I RSB -1
51,_ I I L
TOP O 1 1
mIl III
M
60 1
11- T
II
II
II
II
L.5 L.6 M.2 M.5 M.8 N.1 N.6 0 0.3 0.6 0.9 P.2
OPE?I
ffm - FWD= I - -
I TO
�,
-? 1'- 18' -8" 10' -2" 8' -6" 8' -6" 14' -2" 13' -2" 9' -6" 8' -6" 8' -6"
0
rJ
I
,11.1
(12.
- 11�111unii�n IYIIIIII�����II �
lll�iulu�� u1U1 �
i
i
\I
X64
10.1
I
N
C10.4
M
SHE
COMRAS
COMPANY
1 I I I Lincoln Road Mall
Suite 510
Miami Beach, 171. 33139
(3057 5320433
Km�
N I P.C. JOISTS @5' -6" I I -
I II
Iof
III
II SEE
NO.6
T,
TOS
II
N
2 co coI I J
12 CONC. WALL m 1 S5.11 00 1
EV. LOWd - I alo 1 1 cn III
of II '
3 11
S5.11 ,
I
C CONC. SLAB I I
W/ #4 @12 "O.C• I�
I MECH. Do I O
TOP & BOT. N I 0 EQUIP. I I a
EA.WAY, STAGG. M (I � 136 PSF 1m GPI
of I c3Fo 11
Imo@ I
SHEAR
PRE -FAB I I I STAIR x
CURB, SEE MECH. I P.C. JTS. @ 5' -6" I I ���� E-4
DWG'S. N N
EA.WAY, STAGG. I II 48" m I 1 0
M
co
TrN oS " co
O I 6 CONC. SLAB � I I1
W / #4@ 10" 0. C.
TOP & BOT.
EA.WAY, STAGG.
N 148' -5" RSB -2 - - -
pp TOS
� I TOS
RSB -192 G'
_clnl
J i` v•v,�
"00.
N
2Lo
I
Eo
0
o TOP 16" PC. JOIST
® 6' -6"
48' Cr -
TOS
r/13.2 1 -
R OF AT ELEV. +48' -0'
F R FRAMING FLAN
S E DRAWING -S3.04
0
I I
I
51' -0"
I -- -- _ -1 TOP -
1
5
N S5.03C
N
11 12 13 14
15 116 17
IF
i
1V�(G)I ll:l� I
•
ARCIfffBC= - HNGIMMMG
PLANNING - INTERIOR DESIGN
5960 S.W. 57TH AVE.
MIAMI, FLORIDA
33143
(305) 666 -5474
E
FAX (305) 666 -4994
A.A.C. 000404
\
EUGENIO M. SANTIAGO, P.E.
1
EGISTERED ENGINEER (CIVIL /STRUCT.
IFL.
REG. NO. 19673
r_O"
/►�"
,a1�4, orb -
TOP
\
ISSUE'' DATE
II
P.C.J T
:0
® 4' -6"
- cq
C>
REVISION DATE
c
08-07-96
I
PRICING DOC.
-4'
s*
1
_
-o
0
II
: Z
02 09 -12 -96
1
. U
Im
Of
5
-__
.w
-0
cf
I
CADD FILE NAME
AS305 -RT
DRAWING TITLE
BLDG A ROOF PLAN
SHEET NUMBER
A
I
A -53.05
18
OF