Loading...
12-86 70F7-0140 0 ra■ MAN no 0 ME ME ME ME v■ 1 2 3 4 5 6 7 8 9 10 A A.1 B 1 B.8 C D 5 D.8 E E.6 F.2 F.3 G.2 G.8 H.1 H.2 H.8 I.5 I.7 I.8 J.2 J.6 5.09 S5.16 245' -9" 10' -0" 3' -3" ' -0" 25' -6" 1' -0" ' -0" 15' -9" 10' -11" ' -3" 24' -7" 24' -4" 20' -9" 1' 21' -2" 18' -0" 14' -0" 14' -3" 12' -3" 190' -7" SHAFT 0 ENING R -5 ELEVATOR 0 ENING -RSB -1 6„ PRSBP PANELS RS -3 RB 7 1.1 I - I - - - - - -- 7EN STRUCTURE AB T �HOWN II FOR CLARITY. II T 77777 rSEE ENLARGED PLAN. 1 .W. AT STAIR A II 5.02 l b - (BELOW) soh -0" 6" THK SLAB 4 +52' -0" uTOs W/#5@1 2 T. & B. E.W. - - - 2 I I S.W. @ S I oz 'b A 1(BELO I SEE NOTE No.12 1 I m _ -1co N I cl 4 - - _ RSB -5 I RSB -6 SB -7 - -RS -8 - 1 6" P.C. PANELS RSB -14 RSB -15 3 - -- ----- - - - - -� -- -- -- I - - - - -- = - - - -- N 1 I IIo S.W. 3.1A LOW) - -= -- 3.1 �, 1 - I� o I °I 5 � m ml S5.02 I I U' 4 N o N MECH. E UIP. 124 P.C. JOISTS o 1� o (75 PSF s2' -o" 1 I 2 (-')1 1 s N I a 1- 1 m S5.16 'TO N I Im I SEE NOTE No.6 I m l " 1 (BEW WjI.P CON RETE WALL �i RPD-4 - -- RSB -S I- -- -RSB -6 -- -- SB -7- R I `r' 5 o A/C BRACKET SUPPORT (TYP.) II II I - I % SEE STD. DETAIL. Im I 1 <52 0'> 1m M 1 24 P.C. JOISTS @ 4?-8" = I -� I DOUBLE JOIST I I 70' -9" co S.W. AT STAIR A -3 I I rn 100 To g1 (BELOW.) I I 1 1 o RSB -9 11 ME CH I QF IPm I � <70.0'> ml CD r2 _ _ RSB -10 _-1 _ _ _RSB_ -11 _ RSB -12 _ _ _ RSB_- S Tos I I I S5.09 m - 6 I - - -- - - -- -- - - - - -- - - - - - - E6 27 -- - - �LnPFQ -11 Lot `i I m 2'-� I c S _� o OS T� T LO 1 &4 �' 1 C/) 70'- m 48' -0" Fr - 0 or- TOS t os RS RSB -1 _ _ _RSB _18 RSB =19 _ _ _ RSB -_ RSB= 21_(HI) _ _ RSB- 2 _ RSB= 23 - - - -- -- 8 RSE 16 RSB -17 RSB -18 RSB -1I9 RS -20 (LOW) SB -24 (HI) RSB -25 (HI) RSB -26 RSB -27 RSB -28 (HI) CMU ALL. m 70' -7 1/2" o I T I Tos 24" P.C. JOISTS @ 5' -8" �I ITOS a co I N V) I I I s9' -11 <70.0'> I T0� I TOS RSB_29 _ _RSB- 0 _ RSB -31 I __- RSB_32 _ - RSB- 33______� R -2� j I.-. 1 1 III ml / ,-,1 247 P.C. JOISTS @ 5'-87 �Icv `i11 II 6 THK SLAB j AIN REINF. #4 @12" � I & B. IE.W. STAGG. I I TOS I I I Tos / I - - RSB =29 _ _I_ RSB - �0 _ _ _ _ RSB - 31 � -, I I NI RSB -29 j III I I I I I I col 1 iI S51,3 PLAMIM N 1 o ROOF A ELEV. +48'-Y' / I N mI ml I I FOR F G PLAN C.I. . PARAPET / 1 En M I �I 1 � EL VARIES. � N / I I I SEE DR ING A -S .04. j I RSB -29 RSB- 0 RSB -31 I I I I 48 -� - - - - - -- - -- -- - - - - -J TOS 6 "THK SLAB RSB -64C cn v cv W/ #4@12 / �, I I Ln T. & B. W. STAG_ o I I 1 I <41.01> pry m M1 I DOUBLE JOIST I I 1 m=_ = = = -J I _I M N® I r -I I SB 12 4-, i RSB -34 T RSB -35 RSB -361 I I RSB -38 1 I RSB -39 RSB -40 RS B-4 ---- - - - - - -- - m IRSB- 5A - - - -- RSB -37 TRUCTURE ABOVE N v ~ o I OT SHOWN FOR o v co ° 12.5 CLAR TY. SEE ENLARGED o m U / 110 � PARTIAL PLAN DETAIL � m � c° / m BS3. 6 m I ® o/ 13 1 RSB =6 = _ = RSB -65= - _ _ = RSB -66 = _ _ = RSB =67 � = R - __ - 1 r RS so' 10" 4' e• 4 Tos GA 3 u S J roo M 1 o I (3 6 "THK SLAB v~i �1 1 ��R B 4p r s - W/ #4 ®12" o �I 1 G 3 \ 1 H.7 co @ T. & B. E.W. STAGG. ® - < +56' -0 "> I I I I // ` S5.17 7 ® SEE NOTE No.6 I 1 13.8 / ` \ 21 \ 4" S5.03 - - - - - RSB -6 _ _ RSB =67 _ RSB -68 _ J I / / \ 14 - - - - - -- - -- - - -- - - - -- r // 1 28',� 1 0 / / / / o / ° S5.03 8 I.2 S. ® (BELOW) cn - - - -- N �' X11 14.1 ^ /; `��;��� // 2'o I9 h _ - - - -- 7 0 5 (3 0 CE ZA 0 - m �.03 T YP. I a - o) Cv/ 4 ° m i rn S5.04 - .7 A/C BRACKET SUP OR (TY .) SEE STD. DETAIL. RSB -74 RSB -6 RSB -70 RSB -71 RSB -72 m/ / 6 �6" do/ / 1 2 3 4 5 6 7 8 9 10 11 12 13 I 14 I 15 NOTES: KEY PLAN 1. ROOF SYSTEM CONSISTS OF A 4 1/2" MIN. CONC. SLAB REINF. W/ #3@12 O.C. E.W. CENTERED. PRECAST PRESTRESSED JOIST SHALL BE 16" DEEP EXCEPT AS NOTED; SPACING OF JOIST AS NOTED ON PLANS. 2. SUPER IMPOSED LOADS (SIL) 65 PSF EXCEPT AS NOTED. 3. FIRE RATING 2 HOURS. 4. TOP OF CONCRETE SLAB ELEVATION AS NOTED ON PLAN. 5. ELEV.O' -0" = ELEV. 11.00' NVGD. lip 6. SHEAR FRICTION REINFORCEMENT TYPICAL AT ALL SOFFIT FRAMING INTO SUPPORTS. 7. CONTRACTOR TO COORDINATE THE LOCATION OF ALL NON BEARING CONCRETE BLOCK WALLS WITH THE ARCHITECTURAL DRAWINGS. THEIR ADDITIONAL LOAD (840 LB/L1. FT.) IS IN ADDITION TO THE SUPERIMPOSED LOADS INDICATED IN THE GENERAL STRUCTURAL NOTES (SEE DRAWING S -6.01) PROVIODE DOUBLE PRECAST CONC. JOISTS UNDER NON BEARING BLOCK WALLS WHERE WALLS RUN PARALLEL TO JOISTS DIRECTION. PROVIDE 2 #5 BARS CONT. BOTTOM WHERE WALLS RUN PERPEND. TO JOISTS DIRECTION. 8. FOR BEAMS SCHEDULE SEE DRAWING S9.02 THRU S9.07 9. FOR COLUMN SCHEDULE SEE DRAWING S8.02 AND S8.03 10. FOR SHEARWALL DETAIL SEE DRAWINGS S6.01 THRU S6.05. 11. FOR TIE BEAMS AND TIE COLUMNS SEE GENERAL STRUCTURAL NOTES ON DRAWING S8.01. 12. TEMP. & CRACK CONTROL REINF. W/ #3 @12 "X6' -0" LONG TOP STAGGER ENDS 1' -0" (TYP. AT ALL SOFFIT BEAMS) BLDG. A ROOF FRAMING PLAN SCALE:1 /16 " =1' -0" is 17 1 1e SdMON :61 SHE RWALL AT Tos STAR D -2 - 59' -0" M IN Uri Mm 6" C NC. SLAB TOP W/ 4@ 10" O.C. NATIONAL CITY CENTER Tn P & B OT. P.O. BOX 7033 AY, STAGG. INDIANAPOLIS, IN 46207 RSB - 2 (317) 636 -1600 M I - //�� 110 os co I I RSB -1 51,_ I I L TOP O 1 1 mIl III M 60 1 11- T II II II II L.5 L.6 M.2 M.5 M.8 N.1 N.6 0 0.3 0.6 0.9 P.2 OPE?I ffm - FWD= I - - I TO �, -? 1'- 18' -8" 10' -2" 8' -6" 8' -6" 14' -2" 13' -2" 9' -6" 8' -6" 8' -6" 0 rJ I ,11.1 (12. - 11�111unii�n IYIIIIII�����II � lll�iulu�� u1U1 � i i \I X64 10.1 I N C10.4 M SHE COMRAS COMPANY 1 I I I Lincoln Road Mall Suite 510 Miami Beach, 171. 33139 (3057 5320433 Km� N I P.C. JOISTS @5' -6" I I - I II Iof III II SEE NO.6 T, TOS II N 2 co coI I J 12 CONC. WALL m 1 S5.11 00 1 EV. LOWd - I alo 1 1 cn III of II ' 3 11 S5.11 , I C CONC. SLAB I I W/ #4 @12 "O.C• I� I MECH. Do I O TOP & BOT. N I 0 EQUIP. I I a EA.WAY, STAGG. M (I � 136 PSF 1m GPI of I c3Fo 11 Imo@ I SHEAR PRE -FAB I I I STAIR x CURB, SEE MECH. I P.C. JTS. @ 5' -6" I I ���� E-4 DWG'S. N N EA.WAY, STAGG. I II 48" m I 1 0 M co TrN oS " co O I 6 CONC. SLAB � I I1 W / #4@ 10" 0. C. TOP & BOT. EA.WAY, STAGG. N 148' -5" RSB -2 - - - pp TOS � I TOS RSB -192 G' _clnl J i` v•v,� "00. N 2Lo I Eo 0 o TOP 16" PC. JOIST ® 6' -6" 48' Cr - TOS r/13.2 1 - R OF AT ELEV. +48' -0' F R FRAMING FLAN S E DRAWING -S3.04 0 I I I 51' -0" I -- -- _ -1 TOP - 1 5 N S5.03C N 11 12 13 14 15 116 17 IF i 1V�(G)I ll:l� I • ARCIfffBC= - HNGIMMMG PLANNING - INTERIOR DESIGN 5960 S.W. 57TH AVE. MIAMI, FLORIDA 33143 (305) 666 -5474 E FAX (305) 666 -4994 A.A.C. 000404 \ EUGENIO M. SANTIAGO, P.E. 1 EGISTERED ENGINEER (CIVIL /STRUCT. IFL. REG. NO. 19673 r_O" /►�" ,a1�4, orb - TOP \ ISSUE'' DATE II P.C.J T :0 ® 4' -6" - cq C> REVISION DATE c 08-07-96 I PRICING DOC. -4' s* 1 _ -o 0 II : Z 02 09 -12 -96 1 . U Im Of 5 -__ .w -0 cf I CADD FILE NAME AS305 -RT DRAWING TITLE BLDG A ROOF PLAN SHEET NUMBER A I A -53.05 18 OF