12-86 4OF7-223
no al AN ml I VO4 G F E D C it A 1 10 12 RESIDENTIAL UNITS FEEDER SCHEDULE BLDG. UNIT NO. S PANEL E WIRE CONDUIT A A3 -1 R 1 3 #2 1 1/4" LAUNDRY ROOM A3 -2 R1 3 #2 1 1/4" A3 -3 R1 3#2 1 1/4" A3 -4 R1 3 #2 1 1/4" A3 -5 R 1 3 #2 1 114 A3 -6 R1 3#1 1 114" A3 -7 R1 3 #1 1 114" A3 -8 R1 3 #1 1 114" A3 -9 R2 3-1/0 1 114 A4 -1 R 1 3 #2 1 114 A4 -2 R1 3 #2 1 114" A4 -3 R1 3 #2 1 1/4" A4 -4 R 1 3 #2 1 114 A4 -5 R1 3 #2 1 114" A4 -5 R1 3 #2 1 114 A4 -6 R1 3 #1 1 114" A4 -7 R1 3 -1/0 1 112" A4 -8 R1 3 -1/0 1 1/2" A4 -9 R2 3 -1/0 1 1/2" HOUSE A 1_ 6 G 1 1/4!' B B3 -1 R1 3 #1 1 114" B3 -2 R 1 3 #2 1 114 133 -3 R1 3 #2 1 1/4" B3 -4 R1 3 #2 1 1/4" B3 -5 R 1 3 #2 1 114 B3 -6 R1 3 #2 1 114" B3 -7 R1 3 #2 1 1/4" B3 -8 R1 3 #2 1 114" B3 -9 R 1 3 #2 1 114 B3 -10 R 1 3 #2 1 114 B3 -11 R2 3#1 1 114 B4 -1 R2 3#1 1 114 B4 -2 R1 3 #1 1 114" B4 -3 R1 3 #2 1 114" B4 -4 R 1 3 #2 1 114 B4 -5 R 1 3 #2 1 114 "R2" B4 -6 R1 1 3 #2 1 114" B4 -7 R1 3 #2 1 114" B4 -8 R1 3 #2 1 1/4" B4 -9 R1 3 #1 1 114 B4 -10 R1 3 #1 1 1/4" B4 -11 R2 3 #1 1 114" RESIDENTIAL UNIT FEEDER. HOUSE B 4 -300 MCM 2 1/2" O REFER TO BLDGS. A AND B ONE -LINE DIAGRAM, SHEET E7.01 FOR RATING AND SIZES OF EQUIPMENT, CONDUCTORS, CONDUITS AND OTHER ADDITIONAL INFORMATION NOT SHOWN ON THIS DRAWING. OCONTRACTOR SHALL COORDINATE WITH F.P.& L. CO. ALL PENETRATIONS INTO THE VAULT, FINAL LOCATIONS OF CONDUIT STUBS, CONDUCTOR LENGTHS AND TERMINATIONS PRIOR TO COMMENCING THIS WORK. O PASSENGER ELEVATOR MAIN, 3P., 200A., ENCLOSED CIRCUIT BREAKER WITH SHUNT -TRIP DEVICE. O4 SHUNT -TRIP SIGNAL WIRING TO HEAT DETECTORS LOCATED IN ELEVATOR EQUIPMENT ROOM AND IN THE ELEVATOR SHAFT. O 3 -3/0 & 1 - #6 (G) IN 2 7C. TO ELEV. EQUIPMENT ROOM. O6 3/4 "X 10', COPPER -CLAD GROUND ROD. CONNECT TO GROUNDED SERVICE CONDUCTOR (NEUTRAL) IN SERVICE MAIN. BOND TO REINFORCING STEEL IN BUILDING FOUNDATION, TO THE COLD WATER PIPE AND TO THE SECOND GROUND ROD WITH 1 -2/0 AWG. IN 3/4%. ALL CONNECTIONS ON GROUND RODS SHALL BE EXOTHERMICALLY WELDED. 7O BOND TO REINFORCING STEEL IN BLDG. FOUNDATION AND TO THE COLD WATER PIPE.- O8 1#6 IN 3/47C. GROUNDING CONDUCTOR CONNECT TRANSFORMER SECONDARY NEUTRAL AND TTRANSFORMER GROUNDING LUG TO GROUND ROD. �g COMBINATION, ONE -UNIT, STEPDOWN TRANSFORMER AND PANELBOARD IN INTEGRATED ENCLOSURE. 48OV. PRIMARY WITH CIRCUIT BREAKER, 5 KVA., SINGLE PHASE, 240/120V. SEC., TRANSFORMER WITH 2P, 30A., SECONDARY MAIN AND SIX, ONE -POLE, 20A. BRANCH CIRCUIT BREAKERS. REFER TO SCHEDULE. 10 EMERGENCY POWER FEEDER. REFER TO PANEL SCHEDULES. RESIDENTIAL UNIT PANEL "R1" OR "R27 [/A I N RESIDENTIAL PANEL "R1" OR "R2" RESIDENTIAL UNIT FEEDER. REFER TO FEEDER SCHEDULE (TYPICAL) 13 15 16 17 11 ELEVATOR EQUIPMENT FUSIBLE DISCONNECT SWITCH, 3P., 100A., 480VAC. FUSES AS PER ELEVATOR EQUIPMENT REQUIREMENTS PROVIDE AUXILIARY, ELECTRICAL INTERLOCK, CONTACTS TO MONITOR SWITCH POSITION. CONNECT INTERLOCK CONTACTS TO ELEVATOR CONTROLLER. 12 3/4 "C. WITH CONTROL WIRING FROM SWITCH INTERLOCK CONTACTS TO ELEVATOR CONTROLLER. CONNECT, AS PER ELEVATOR EQUIPMENT INSTRUCTIONS TO DISABLE ELEVATOR CONTROLLER BATTERY POWER AND STOP THE ELEVATOR CAB IN POSITION. 13 POWER FEED TO ELEVATOR EQUIPMENT, 3 #3 IN 1" C. 14 PASSENGER ELEVATOR MAIN, 3P, 150A., ENCLOSED CIRCUIT BREAKER WITH SHUNT -TRIP DEVICE. 15 1 - #6, CU, THHN, IN 3/4%. TO TEL. BACKBOARD. - • - . - - FOURTH FLOOR THIRD FLOOR SECOND FLOOR MAIN ELECT. ROOM BUILDING "A" RESIDENTIAL BUILDING "A" BUILDING "A" ELECTRICAL ROOM RESIDENTIAL ESIDENTIAL UNIT ELEV. EQUIP. METER WITH 100A. ROOM CIRCUIT BREAKER (TYP.) ELEVATOR FEEDER OR O r MAIN 13 ON O a 12 4 OUSE KWHR le METER WITH OR O is O 9 125A. CIRCUIT 11 BREAKER -� ORION O.oI PANEL PANEL MAIN HOUSE PANEL "PE" o 0.0 1 OF 1 O® O„ PANEL "EHP" ❑ A O 1 o O•oa 8 8 1 -2/0 IN 3/4 "C. 8 TX TX REQ. LENGTH SPARE WIREWAY 15 0 n n 6 T T GROUND FLOOR 1-1-27 SPARE - L4 SIJ CONDUIT 1" SPARE 0 4W. Y, Z tLw :t i o I I o I REFER TO ONE -LINE 5 CONDUIT I I 10 I RAMS SHEET E701 I DIAGRAMS, I � I � R SERVICE L- -J L - - - - - - I FO SE I CONDUCTORS AND _ _ _,S _ - _ - - I �I CONDUITS - - - - - - - - - - - - - - - I [too] RESIDENTIAL SERVICES -LOAD CALCULATIONS (NEC. ART. 220, 220 -32) BUILDING "A" 16 APTS. AT 16.57 KVA. EACH= 265.12 2 APTS. AT 17.4 KVA. EACH= 34.74 TOTAL APT. LOAD: 299.86 KVA. AS PER TABLE 220 -32 DEMAND FACTOR: 0.38 295 KVA. X 0.38= 114.95 KVA., 317 AMPS AT 208V., 30 HOUSE LOAD, PANEL "A ": 24.22 KVA., 116.4 AMPS., AT 208V., 10 APT.. DEMAND AMPS: 317 HOUSE PANEL AMPS: 116 TOTAL SERVICE AMPS: 433 SERVICE LATERAL PROVIDED: 2 SETS OF 4 -300 KCM IN 2 1/2 "C. EACH 2.3% VOLTAGE DROP BUILDING "B" 17 APTS. AT 16.57 KVA. EACH= 281.7 5 APATS. AT 17.4 KVA. EACH= 87 368.7 DEMAND FACTOR: 0.36 368.7 KVA.X 0.36= 132.73 HOUSE LOAD, PANEL "8": 60 192.73 KVA, 535 AMPS., AT 208V., 30 SERVICE LATERAL PROVIDED: 2 SETS OF 4 -500 KCM IN 3"C., EACH. 2.54% VOLTAGE DROP - - - - - o - ----- ------ ------ ------ ------ ------ ------ ------ ------------- __j ------------------------------------------------- ------ ------ ------ BUILDINGS "A" & "B" RESIDENTIAL SERVICES ELECTRICAL RISER DIAGRAM N.T.S. 1 2 3 4 5 6 7 8 9 _ 10 11 12 13 14 IN m 17 In 13 w (o) { ol 1 011 obllillk\si�lll\iLUIIII"l 09), 10 i• N It) FEMME 1- �� I I' II ARCHMC M - BNCROM 1NG PLANNING -IN =OR DL%Qi SybU S.W. 5 /IN AVL. MIAMI, FLORIDA 33143 TEL (305) 666 -5474 FAX (305) 666 -4994 EAA 0002416 EB 0002354 ANGEL E. LORENZO, P.E. FL ELECTRICAL ENGINEER REG. NO. 31137 - Vic•. �'' ' -` ISSUE- -DATE -o o <=> REVISION DATE PRICING D DC. 12 -10 -96 0 4 -14 -97 z w CADD FILE NAME E- 805 -RT DRAWING TITLE ONE LINE DIAGRAMS A SHEET NUMBER E8.05 RESIDENTIAL U UNIT L LAUNDRY ROOM PANEL P PANEL "R1" " "L" OR " R2" FOURTH FLOOR RESIDENTIAL UNIT PANEL "R1" OR "R2" THIRD FLOOR RESIDENTIAL UNIT FEEDER. REFER TO FEEDER SCHEDULE (TYPICAL) SECOND FLOOR BUILDING "B" B BUILDING "B" B BUILDING "B" MAIN R RESIDENTIAL R ELEV. EQUIP. ELECTRICAL R ROOM E ELECTRICAL R ROOM E ROOM RESIDENTIAL UNIT ELEVATOR R ON O O o C METER WITH 100A. (TYP.) MAIN O ON O ON O OBOB 1 12 4 O ON O O . O. O O K HOUSE- . O METER ON O O. O O. O O. PANEL M ATS o ON O O a MAIN O 2 0 1 O o O H HOUSE P PANEL " E2' ❑ o O a 1 1 O o P B" OR O O ® ® O O e O O® 2 1 14 2 21 1 8 8 8 12" X 1 12" X 39 1 18 WI REWAY O O 1 -2/0 I IN 3/4" C C. P PAR © G GROUND FLOOR ' ` `� � � , ' ' 15 ' 1 1" SPARE CONDUIT I _ _J I - - - - - - - I - - - - - - - -- - -� -� - - I ' - - -' - - ' ------ - ------ - -� 0 0 I - ----- ------ ------ ------ ------ ------ ------ ------ ------------- __j ------------------------------------------------- ------ ------ ------ BUILDINGS "A" & "B" RESIDENTIAL SERVICES ELECTRICAL RISER DIAGRAM N.T.S. 1 2 3 4 5 6 7 8 9 _ 10 11 12 13 14 IN m 17 In 13 w (o) { ol 1 011 obllillk\si�lll\iLUIIII"l 09), 10 i• N It) FEMME 1- �� I I' II ARCHMC M - BNCROM 1NG PLANNING -IN =OR DL%Qi SybU S.W. 5 /IN AVL. MIAMI, FLORIDA 33143 TEL (305) 666 -5474 FAX (305) 666 -4994 EAA 0002416 EB 0002354 ANGEL E. LORENZO, P.E. FL ELECTRICAL ENGINEER REG. NO. 31137 - Vic•. �'' ' -` ISSUE- -DATE -o o <=> REVISION DATE PRICING D DC. 12 -10 -96 0 4 -14 -97 z w CADD FILE NAME E- 805 -RT DRAWING TITLE ONE LINE DIAGRAMS A SHEET NUMBER E8.05 DRAWING TITLE ONE LINE DIAGRAMS A SHEET NUMBER E8.05