Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
12-86 4OF7-217
Y 4� ,a If 1 2 5 6 7 8 9 10 I I 12 13 14 15 16 17 --------------------------------------------------------------------------------------------------------- HOUSE KWHR METER I � -IN SEPARATE ENCLOSURE E HOUSE PANEL / Er 100A TENANT TWELVE APT. I PANEL I THROUGH TWENTY-TWO( TENANT 100A APT. PANEL J MODULAR METER CENTER, 30 MAIN 10 BRANCHES (TYP:) 149 G ra E n � A DUAL VOLTAGE FP &L E 208V 277 480V TRANSFORMER VAULT I 120/208V / KW I INDIVIDUAL FREIGHT ELEVATOR KWH i R 600A HR 100A I TENANT METER -- KWH PAN EL " FEA" ^ I ONEL -- - - - - - - - - ----- - - - - -- - - - -- - - - - - -- -------------------- - - - - -- -------------------------------------- - - - - -- - - - -� PASSENGER H B O 2500A. BUS DUCT 2000A. BUS DUCT 250OA. ELEV. MAIN HOUSE DISTRIBUTION THROUGH TENANT 400 A. SWITCHBOARD 'HSA' I APT. BUS DUCT b 1 -1/0 �' TENANT TDB1 TDB2 TD63 T F CW KW PANEL D IN 1 /2 "C. 0 ® MAIN 3/4 "C. W /CONTROL M + / '1 ("N0.4 MAIN WIRING TO TO PANEL MAIN N0.1 GFP JR HR ELEVEN 1600A. NO.5 EMERG. 2000 100A BOLTED a MAIN G 1 - #6 BOLTED 600A GEN. GDP" 3P 2000 A PRESSUSRE No.3 - IN 1 /2" C. - PRESS SW 60A. 60A. SWITCH 2500A ATS "E1" G W /GFP. & O 60A. � � �- �� � TENANT G GFP 4 POLE 1 -500 KCM 1600A. 125A. APT. 300A. IN 1 1/4" C. = CLASS L 4 POLE 60A. 60A. 60A. 60A. PANEL 1 -500 KCM FUSES ATS IN 1 1/4 "C. _ A A l G TO 3/4" C. W/ O ' ' 60A. 60A. 60A. -0 60A. TO AMC GDP C CONTROL ) 500A 400A. �� �� 0--E 17-0- 0- 31-0 DISTRIBUTION WIRING TO HHA LA + AREA "B" RESIDENTIAL PANELBOARD EMERG. EMERG, G 60A. � lu 11 NATIONAL CITY CENTER �.0. EOX 7033 INDIANAPOLIS, IN 46207 1600A BUS DUCT. (317) 636 -1600 EGL TO ATS 'A' „ Er TO PARKING GARAGE 15 KVA. TO ATS ENANT TDB5 EG AIN NO.2 3P 1600 A GFP 1600 nGENERAT06R (t 1 -2 /0 IN 3/4 "C. - GEN. TO ROOFTOP PANEL 60A 60A l O C.T.'S A/C CHILLER 0-U=_0_/ � (TYP) 850 TONS. "THA" 60A. 60A. 1 - 400 KCM IN HHA2 45 KVA 1 -400 KCMG 400A. 400A. 200A. IN 1 1/4% DIGITAL IN 1 1/47C. 'EHP SE 60A. 60A. G KWHR `) METER �� -0\-0- i 11-0 1 (TYP.) lO �-'� ..'_S 60A. 60A. _ KW KW 02 5-• LR H LA 500A SECT.I SECT-11 100A HR ) HR 100A GUTTER ELEVATOR TENANT TEN ONE TENANT PANEL "P�' APT. I I APT. PASSENGER IN TOWER I I 400A. LASFR ROOM PANEL SCHEDULE THROUGH 6 -3 1/2" EMPTY CONDUITS (CONDUCTORS BY TENANT) © 3 - #1 & 1 - #3 (N) IN 1 1/4 "C. MAIN NO.2 © i KW QD 2 SETS OF 4 -300 MCM IN 2 1/2-C. EA. & 2 -2 1/27C (SPARE) EIGHTEEN HR 2-3"C. (SPARE) TENANT 3 SETS OF 4 -500 MCM & 'l -4/0 (G) IN 100A © 3 -500 MCM & 1 - #3/0- (N) IN 3 "C. APT. QH 3 -500 MCM & 1 -3/0 (N) IN 3"C. HOUSE QI 4-1/0 IN 1 1 /2" C. PANEL Q 4 -1/0 & 1 - #1 (G). IN 2 "C. Q 4 -3 l/2" EMPTY CONDUIT) (CONDUCTORS BY TENANT) 4�1 HOUSE _o ISSUE DATE 100A PANEL o "A" ° REVISION DATE C .rn 08-07-96 AREA 'A' RESIDENTIAL PANEL THROUGH l i I NINE 100A TENANT FIAPT. PANEL G 1 -1 /0 IN 3/4"C. SERVICE & FEEDER WIRING SCHEDULE AREA "B" 6 -3 1/2" EMPTY CONDUITS (CONDUCTORS BY TENANT) © 3 - #1 & 1 - #3 (N) IN 1 1/4 "C. MAIN NO.2 © 3 -500 MCM, & 1 - #3 (G) IN SC. If 300 KVA QD 2 SETS OF 4 -300 MCM IN 2 1/2-C. EA. & 2 -2 1/27C (SPARE) QE 2 SETS OF 4 -500 MCM IN 3" C. EACH & 2-3"C. (SPARE) Q 3 SETS OF 4 -500 MCM & 'l -4/0 (G) IN 3 1/27C. EACH. © 3 -500 MCM & 1 - #3/0- (N) IN 3 "C. 113 KVA QH 3 -500 MCM & 1 -3/0 (N) IN 3"C. HOUSE QI 4-1/0 IN 1 1 /2" C. 1661 KVA Q 4 -1/0 & 1 - #1 (G). IN 2 "C. Q 4 -3 l/2" EMPTY CONDUIT) (CONDUCTORS BY TENANT) 1 2 3 TO GARAGE ELEVATOR MACHINE ROOM TO SOUTH ENTRY ELEVATOR MACHINE ROOM TO GARAGE FREIGHT ELEV. EQUIP. ROOM ELEVATOR PANEL " FEB" TO BUILDING B RESIDENTIAL ELECTRICAL ROOM 0 MULUtU UAJt JWI I Uh WITH SHUNT TRIP 5 I 6 45 KVA - 2LA EPA BLDG. A ELEC. ROOM A -143 TRANSFORMER VAULT BLDG. B SECTION "A" ONE -LINE DIAGRAM PROVIDE HORZ. BLDG. A ELEC. ROOM A -143 FEED -THRU BUS FOR FUTURE EXP. TDB4 60A. 60A. --0\-0iI11 -0 60A. 100A 60A 60A 0- 1I \-o-0=3--o 100A 100A 0__' o- -o\-o -M 13-0 60A. 60A. 0--T M-0-/*-- -off 31-o 60a7 60A. LOAD TABULATION AREA "A" AREA "B" MAIN NO.1 1216 KVA MAIN NO.1 1300 KVA MAIN NO.2 1063 KVA FUTURE EXP. 300 KVA EMERG. 37 KVA EMERG. 22 KVA ELEVATORS 237 KVA ELEV. (FUT.) 122 KVA HOUSE 332 KVA ELEVATORS 113 KVA CENTRAL A/C 1188 KVA HOUSE 230 KVA AMC (80% D) 1661 KVA CENTRAL A/C 1164 KVA 5734 KVA ref ` ,�� °- '�. 2962 KVA 7 I 8 I 9 I 10 I I 1 I 12 13 1 - #6, 1, 14 SECT.I 15 TO GAMEWORKS GDP - - F 1 -4/0 IN 1 "C. TO ATS TO ATS 'C' " E2" 3/4 "C. W/ CONTROL WIRING TO EMERG. GEN. FOR CONTINUATION SEE DWG. E7.02 NOTES: 1. AMPERE RATING DENOTES SWITCH SIZE. FUSES ARE TO BE SIZED ACCORDING TO ACTUAL TENANT LOAD. 2. LOAD DESIGN ALLOWANCES ARE AS FOLLOWS: A. RETAIL TENANTS: 8.4 VA /SQ. FT. B. SPECIALTY STORES: 10 -12 VA /SQ.FT. C. RESTAURANTS: 28 VA /SQ.FT. D. ANCHOR STORES: AS PER TENANT REQUIREMENTS 16 I 17 I 18 THIS COMRAS COMPANY 1 111Lincoln road Mall Suite 510 Miami 19erA FL. 33139 (305)-532-0433 F =0 11-1) f M �I , I I ' W. z I- I "i• ITT � 1[. ■� AIhCC1iITECIUM • ENCANEEEING PLANING • W= OR DMGN 5960 S.W. 57TH AVE. MIAMI, FLORIDA 33143 TEL (305) 666 -5474 FAX (305) 666 -4994 EAA 0002416 EB 0002354 ANGEL E. LORENZO, P.E. FL. ELECTRICAL ENGINEER REG. NO. 31137 ref ` ,�� °- '�. •.`� _o ISSUE DATE o ° REVISION DATE C .rn 08-07-96 PRICING DOC. 12 -10 -96 0 02 -12 -97 z 04 -14 -97 w 06-18-97 = -D i .0 - B CADD FILE NAME E- 701 -RT DRAWING TITLE ONE LINE DIAGRAMS SHEET NUMBER A E7.01 i OF