12-86 4OF7-215r
n
11
L
s
r
w
F
E
2
3
!�
5
TYPICAL STAIR LIGHTING
N.T.S.
0
TO EXP)
INSERTS
1 -N BUILE
7
F4111
0
3/8" THREADED GALVANIZED
ROD, LENGHT AS REVD.
SQUARE WASHER, LOCK —
WASHER & HEX NUT
-(EACH SIDE)
-STEEL CHANNEL 1 5/8 "X
1 5/8" (APPROX. 200'/100')
GALVANIZED ----/
STEEL CLAMP
OVERHEAD CONDUIT SUPPORT DETAIL
N.T.S.
IWIVI�RUN TO PANEL
D
--FLOOR SLAB (-FLOOR SLAB
42" MIN. 30 "_ MIN.
3" '2" 2" 3" COVER
COVER '�` I I 3" 2', 3»
PARE CONDUITS
.•Y:
_ �I'i— :. ..�• ::: _ �; 5 CONDUIT .,
4' ' S 6 „� (TYP. OF 9)
N�/- 3000 PSI
CONCRETE
3000 PSI ;�, r , ► ., ► . e R
1'— CONCRETE-
. Q
0
B 4W UCT BANK
CD 9W5 DUCT BANK
SECTION "A -A" CTION "B -B"
N.T.S.
QO
. .S.
(FOR CONDUIT SIZE REFER
w TO FLOOR PLANS).
J_
Q
W
0
. U
z
w
w
Y
Q
d -
U
w
° 1 2 3 4 5 8
CD
6" TO 12"
PVC END BELL OUTSIDE WALL
WITH PLUG. (TYP.)
IL IL J
i
D
D' p• '
oA D 1-,_�FINISHED GRADE
p•
VARIES
D ° FOOTING
p•
D
°
D .p•
4
D •D. p
6' RADIUS ELBOW p-
n
D To
STAGGERED CONCRETE ENCASEMENT
COUPLINGS
SECTION
V i
TO BUILDING "A'
1 1/4!* SLEEVE O VAULT
IN SLAB
5" CONDUIT
7 4 1 (TYP. OF 6)
FROM F.P. & L. CO
PLAN MANHOLE
VAULT "B" PEDESTAL DETAIL
N.T.S.
— � TO BUILDING "C"
F.P. & L VAULT
`—-9 W DUCT BANK
VAULT "A" PEDESTAL O DETAIL
N.T.S.
11
OTHER'
7/4'
MAIN
4IW
wj
ti 9S,P
13
11V"L -,j f1.J 1 V /IV VLI 1
CABLE CONNECTOR LUGS
GROUND BAR DETAIL
N.T.S.
7 I 8 I 9 I 10 I 11
F/A SYSTEM
TRI MODULE FDAI
rOEM—PANEL
F
/
DATA
LOOP
DETAIL
N.T.S.
F/A sBOL
M4
CHOR TO WALL
PER MOTOR
In
17
[U616
TRANSFORMER MTG.
CHANNEL
n-n
VIBRATION ISOLATORS
ANGLE BOLTS AS REVD.
TO STEEL SUPPORTS
ATTACHED IN BLDG.
STRUCTURE (AS REQ'D)
NEOPRENE —IN —SHEAR
VIBRATION ISOLATOR
1/2" THREADED
GALVANIZED STEEL ROD
1-1/2" X 2" X 3/16"
GALV. ANGLE.
DRY TYPE TRANSFORMER
PROVIDE DOUBLE NUT &
SPLIT LOCK WASHER
BELOW & SINGLE NUT
WITH FLATWASHER ABOVE.
CEILING HUNG
TRANSFORMER INSTALLATION DETAIL
N.T.S. (SYMBOL FT)
NOTES:
TRANSFORMER INSTALLATION IN ELECTRICAL ROOMS SHALL COMPLY WITH
N.E.C. ARTICLES 110 -16.
a a
d a Q Q
d d
S I M0N
I I1
IN
C mew I� 11'mi'm
COMPANY
Lincoln d
slite r
Miaiw ,, .
F
��' el I I � Is I 1
I) I�T�� I fib
RECEPT. POWER CIRCUIT 5960 S.W. 57TH AVE.
LIGHTING MIAMI, FLORIDA 33143
POWER TEL (305) 666 -5474
CIRCUIT L FAX (305) 666 -4994
AA 0002416
3/4" COM. COND. EB 0002354
i
ANGEL E. LORENZO, P.E.
FL. ELECTRICAL ENGINEER
REG. NO. 31137
TYPICAL POLE BASE DETAIL (ALL OY POLES) .•r••,
4•yq�l \Yj -
,' �.
_k
n
4
FLOOR SLAB �- -FLOOR SLAB f —FLOOR SLAB ISSUE DATE i
TyP' •� ----4" WIDE YELLOW WARNING CNI
12" (TYP.) 3" 2" 3» TAPE WITH 2" BLACK LETTERS - o
" " " " " REVISION DATE
3', 2 3', 3" 2, 2 3 24 O.C. TO READ ELECTRICAL 08-07 _
TT —7 TT
PRICING DOC.
Its
''� � ^°' •''� �'•" ROUTE CONDUIT UNDER EXISTING - 12 -10 -96
GRADE BEAMS IN PARKING GARAGE
-,• MAINAT CONSTANT ELEVATION W - 06 -18 -97
REQUIRED SLOPE. z
LLI
CONDUITS SIZE -
AS PER PLANS
(TYPICAL) : 13-
TWO CONDUITS THREE CONDUITS FOUR CONDUITS B
.Q
CADD FILE NAME
E- 601 —RT
UNDERGROUND CONCRETE ENCASED CONDUIT DETAILS DRAwWC TITLE
APPLICABLE FOR UNDERGROUND FEEDERS AND TELEPHONE NON F.P. & L CONDUCTORS SECTIONS & DETAILS
N.T.S. e SHEET NUMBER
1 1
- X6.01
I
12 13 14 15 16 _ 17 18 of