Loading...
12-86 4OF7-2121 2 3 4 5 6 7 M t "C FOR COMM. CABLE 3/4'C FOR TENANT CONTROL LOOP FD /SD FD /SD Fp�SD FD /SD � INFILINK MODULE L ir J I I I I P F TO MAIN ELECTRICAL ROOM F/A PANEL "EA v SF -A6 EPA -4 F PA -1 - — E EPA -2 F/A B- SF-A5 M K LCX -898 TO MAIN ELECTRICAL ROOM LIGHTING A -143 PANEL "TD81" � T CONTROLLER _I EPA- y PANEL - - - „2HA7 T .B 2_14 3/4 C TO T ' 2_16 INFILINK MODULE PANEL TO MAIN ELECTRICAL ROOM _ ^TH,427 PAN L _ `EPA PANEL "HHA "2 11.1 F SQ. "Cr MINI POWER ONE "EPA PANEL (MPZ5540F) "LF" I SF -A7 STARTER re I F .1 E., I-Es' CDI0 I- 0 Ln w JI Q w 0 t z A �fl w W Q m w o BLDG. A ELEC. ROOM A -143 SCALE: 1/2 " =1' -0" 8 9 10 11 12 13 14 15 16 17 18- TC"50/851 CONTR UNIT 3/4" C 1 I 2 I 3 I 4 BLDG. C ELEC. ROOM SCALE: 1/2 " =1' -0" 5 - C -121 m 1 1 /4� CONDUIT THROUGH WALL FOR METERING COORDINATE LOCATION & HEIGHT WITH F.P. & L. CO. SEWAGE LIFT STA. CONTROL PANEL FIRE ALARM PANEL \ U STATION I I \ ALARM \ \ EPC -2 1002 \ EPC -2 SEE NOTE #4 � �,. � � EPC -4 EPC -1 2 4" TEL. CONDUITS _ HHC- 37,39,41 IMAX SEE SHT. C -E3.01 T.T.B. O GROUND BUS BAR ` EPC -3 REFER TO DETAIL TEL. DWG. E6.01 SF -C3 TDB10 EF -C3 F.P.L. TRANSFORMER VAULT TO ELEV. MAIN, BLDG. "D" SEE ONE LINE DIAGRAM DWG. E7.02 4" HIGH CONCRETE - PEDESTAL (TYP.) TO TENANT MAIN BLDG. "D" SEE ONE LINE DIAGRAM, DWG. E7.02 PANEL "EC" MAIN N0.1 � � � "ATS` TDB9 C ` PANEL / "H LC' — -TO TENANT (� PANEL SPACE 607 � � � "FEC" � � � C ORDINATE LOCATION ONDUIT STUB -UPS WITH AL LAYOUT FOR NIKE EL TRICAL ROOM MAIN N0.2 � TRANSF. NIKE / � � wTHC7 PTO GEN. CONTROL ANEL y\ BLDG. "A Q PANEL `HHC TO PANEL GDP BLDG. / TO PANEL "EC2" 0 AfiS � E3 LCX -898 � LIGHTING CONTROLLER 36" MIN. &NNONO 3 � �/� 0 PANEL PANEL Cc" mEPrCis.2 % \ NOTES: 1. PROVIDE 30 ft. OF CABLE SLACK, INSIDE VAULT, FOR ALL SERVICE CONDUCTORS. 2• COORDINATE BUS STUBS PENETRATIONS WITH F.P. & L. CO. 3. REFER TO RISER DIAGRAM FOR GROUND BUS BAR CONNECTIONS. 3. TO SEWAGE LIFT STATION. SEE CIVIL DWGS. 10 I 11 I 12 PANEL "LC' ---- K TO FEEDER PULL � MODU SECTION " 811" CONDUIT UP TO— � TENANT SPACE 807 PASS. ELEV. SHUNT TRIP MOLDED CASE SW. ON UNISTRUT SUPPORTS rcx 850/851 CONTROL MODU VERTICALLY STAC ED BLDG. C MAIN ELEC. ROOM - C -I04 SCALE: 1/2 " =1' -0" 4 L • } 4111 14 I 15 f 16 1 17 L ffiAmI n 94 J COMRAS C OMPA NI I I I I ]Lincoln Load Mall Suite 510 Miami 19eacl�, FL 33139 (30,9 532--0433 p__ (a ARC micrun • wmmm ING PLANNING -MTMOR DMI24 1 1 MIAMI, FLORIDA 33143 TEL (305) 666 -5474 FAX (305) 666 -4994 EAA 0002416 EB 0002354 ANGEL E. LORENZO, P.E. FL. ELECTRICAL ENGINEER RE .. I •' D .. e ISSUE DATE -O O REVISION DATE PRICING DOC. f 12 -10 -96 xr. -o z 2 -12 -97 I _' v 4 -14 -97 . Lis 0 06 -18 -97 :a CADD FILE NAME E- 505 —RT DRAWING TITLE ELECTRICAL ROOMS SHEET NUMBER A