12-86 4OF7-208I M L K J I G F E- 00 M M N aJ �I • i1 `DI0 o� JI Q w 0 Az w v wl Y Q Q7 cn U W 0 1 I 2 I 3 urrrrnr uw _ . nnm� • r L�J m J e. 4 I 5 A -122 ELEV. HLA-13i EQUIP. III III 111111111 11 >r, LN' 1 EGL -19 R® JANITOR FEA -2,4,6 ROOM FOR CANT. SEE-DWG. A -E2.0 1 BLDG. "A" ELEVATOR EQUIPMENT ROOM SCALE: 1/8 " =1' -0" - 20,22,24 NOTES: - - - 1. ALL PIT(S) LIGHT FIXTURES ARE TYPE QK BLDG. "A" ESCALATOR EQUIPMENT SCALE: 1/8 " =1' -0" - E BLDG. "B ESCALATOR EQUIPMENT SCALE: 1/8 " =1' -0" 1 I 2 6 I 7 ♦a, /� ` qqu,. ra 8 I 9 I 10 -H LA -12,14 SUMP PUMP RECEP. (G.F.I. & W.P.) 120V., 1/2 H.P. PASSENGER ELEVATOR BLDG. "A" ELEVATOR EQUIPMENT ROOM SCALE: 1/8 " =1' -0" 8'x8'x3/4" PLYWOOD BACKBOARD B -123 , B -124 SCALE: 1/8 " =1' -0" I 1 12 LOBBY A -4."" �� A -101 EHP -1 FOR CONTINUATION/ SEE DWG. A -E2.01 SCALE: 1/8 " =1' -0" 1io� 1TH FA ra A -103 rt rn 13 SEE SHT. E -801 FOR ADDITIONAL WORK IN THIS ROOM -PE -1,3,5 �EHP -8 / EHP -7 A -30\ \-A- � ELEV. MACH. 1 ,-EHP2 -7 FEB- 8,10,12 �B 28 B-26 ELEV. —102 ELEV. EQUIP. B -22,24 SCALE: 1/8 " =1' -0" BLDG. "B" SCALE: 1/8 " =1' -0" 3 I 4 I 5 I 6 I 7 I $ I 9 I 10 I 11 -.:T TT T - - , yv ` e.6. 3.4.3.4 12 I 13 EPA -7 ALL ELEVAT( LIGHTS ARE (TYPICAL) ELEVATOR PIT(S) RECEPTACLES TO BE W.P. & G.F.I. (TYP -) SUMP PUMP RE( (G.F.I. & W.P.) 120V. 1/2 H.P. 15 I 16 I 17 I 18 A -143 1UU 3,5 SUMP PUMP RECEPT. (G.F.I. & W.P.) 120V., 1/2 H.P. BLDG. "A" ELEVATOR EQUIPMENT ROOM SCALE: 1/8 " =1' -0" BLDG. "A" ELEVATOR PITS FLOOR PLAN SCALE: 1/8 " =1' -0" NOTES 1 - TYPICAL FOR ALL ELEVATOR PITS: PROVIDE A HEAT DETECTOR TO ACTIVATE ELEVATOR SHUNT TRIP. 2 - PROVIDE AT TOP OF THE SHAFT OF ALL ELEVATORS A HEAT DETECTOR AND A SMOKE DETECTOR (NEITHER ARE SHOWN ON PLAN). HEAT DETECTOR TO ACTIVATE ELEVATOR SHUNT TRIP AND SMOKE DETECTOR TO ACTIVATE ELEVATOR RECALL 3 - ALL ELEVATOR PITS LIGHTS ARE TYPE QK 14 PARKING GARAGE ELEVATORS PARTIAL RISER DIAGRAM N.T.S. 15 r6A 17 SHE COMRAS COMPANY I I I I Lmcoln Road Mall Suite 510 Miami Beach, FL. 33139 (305) 532 -0435 5960 S.W. 57TH AVE. MIAMI, FLORIDA 33143 H�"� �' /4 X70' CU -CLAD GND. ROD TEL (305) 666 -5474 FAX (305) 666 -4994 BOND TO FOUNDATION STEEL E8 0002354 I R j OO � 8'X 10'X 3/4 REG. NO. 31137 � O PLYWOOD BACKBOARD .4EL � R EPB -7 6 -o -o HLB -4,6 � -13 �B -2.4,6 TOR SOLID STATE REVISION DATE /CONTROLLER 08-07-96 220V., 30A HUBBELL 2620A PRICING DOC. 12 -10 -96 0 2 -12 -97 VEST. Z 4 -14 -97 � m 30 7' -6" A.F.F. - v 06 -18 -97 OTOR EB o _ _ CL :Q � HLB -9 B -125 CADD FILE NAME E- 501 —RT B -127 E. O ELEV. DRAWING TITLE ((TIE) EQUIP. SHEET NUMBER A BLDG. "B" ELEVATOR EQUIPMENT ROOM E5.01 SCALE: 1/8 " =1' -0" I 1 12 LOBBY A -4."" �� A -101 EHP -1 FOR CONTINUATION/ SEE DWG. A -E2.01 SCALE: 1/8 " =1' -0" 1io� 1TH FA ra A -103 rt rn 13 SEE SHT. E -801 FOR ADDITIONAL WORK IN THIS ROOM -PE -1,3,5 �EHP -8 / EHP -7 A -30\ \-A- � ELEV. MACH. 1 ,-EHP2 -7 FEB- 8,10,12 �B 28 B-26 ELEV. —102 ELEV. EQUIP. B -22,24 SCALE: 1/8 " =1' -0" BLDG. "B" SCALE: 1/8 " =1' -0" 3 I 4 I 5 I 6 I 7 I $ I 9 I 10 I 11 -.:T TT T - - , yv ` e.6. 3.4.3.4 12 I 13 EPA -7 ALL ELEVAT( LIGHTS ARE (TYPICAL) ELEVATOR PIT(S) RECEPTACLES TO BE W.P. & G.F.I. (TYP -) SUMP PUMP RE( (G.F.I. & W.P.) 120V. 1/2 H.P. 15 I 16 I 17 I 18 A -143 1UU 3,5 SUMP PUMP RECEPT. (G.F.I. & W.P.) 120V., 1/2 H.P. BLDG. "A" ELEVATOR EQUIPMENT ROOM SCALE: 1/8 " =1' -0" BLDG. "A" ELEVATOR PITS FLOOR PLAN SCALE: 1/8 " =1' -0" NOTES 1 - TYPICAL FOR ALL ELEVATOR PITS: PROVIDE A HEAT DETECTOR TO ACTIVATE ELEVATOR SHUNT TRIP. 2 - PROVIDE AT TOP OF THE SHAFT OF ALL ELEVATORS A HEAT DETECTOR AND A SMOKE DETECTOR (NEITHER ARE SHOWN ON PLAN). HEAT DETECTOR TO ACTIVATE ELEVATOR SHUNT TRIP AND SMOKE DETECTOR TO ACTIVATE ELEVATOR RECALL 3 - ALL ELEVATOR PITS LIGHTS ARE TYPE QK 14 PARKING GARAGE ELEVATORS PARTIAL RISER DIAGRAM N.T.S. 15 r6A 17 SHE COMRAS COMPANY I I I I Lmcoln Road Mall Suite 510 Miami Beach, FL. 33139 (305) 532 -0435 5960 S.W. 57TH AVE. MIAMI, FLORIDA 33143 TEL (305) 666 -5474 FAX (305) 666 -4994 AA 0002416 E8 0002354 I ANGEL I- WMZO P.E. n- ELECTRICAL ENGINEER j REG. NO. 31137 ' ISSUE DATE -o -o TOR SOLID STATE REVISION DATE /CONTROLLER 08-07-96 PRICING DOC. 12 -10 -96 0 2 -12 -97 Z 4 -14 -97 - v 06 -18 -97 OTOR o _ _ CL :Q CADD FILE NAME E- 501 —RT DRAWING TITLE ELEV. ELEC. ROOMS SHEET NUMBER A E5.01 18 of