12-86 4OF7-1321 2 3 4 5 1 6 7 8 9 10 11 12 H V A C SYMBOLS AND ABBREVIATION S M ABBREVIATIONS PIPING SYMBOLS AFF ABOVE FINISHED FLOOR �HyyR CHILLED WATER RETURN EXPANSIOM COMPENSATOR (BELLOWS TYPE) AP ACCESS PANEL —AHU AIR HANDLING UNIT —�HWS— — CHILLED WATER SUPPLY ITS FLOW SWITCH ARCH ARCHITECTURAL A COMPRESSED AIR BD BACKDRAFT DAMPER C CONDENSATE GATE VALVE BOD BOTTOM OF DUCT L BOP BOTTOM OF PIPE CWR CONDENSER WATER RETURN GAUGE COCK BTU BRITISH THERMAL UNIT r CLG CEILING —CWS— CONDENSER WATER SUPPLY � I � BUTTERFLY VALVE CD CEILING DIFFUSER RG REFRIGERANT, HOT GAS CG CEILING GRILLE MOTOR OPERATED BUTTERFLY VALVE CR CEILING REGISTER RL REFRIGERANT, LIQUID CHWP CHILLED WATER PUMP RS REFRIGERANT, SUCTION GAS �TS- CWP CONDENSER WATER PUMP TEST STATION CONNECTION POINT K CU CONDENSING UNIT — RGP — REFRIGERANT, HOT GAS PUMPOUT --->—FS FLOW STRAIGHTENER CFM CUBIC FEET PER MINUTE C.O.P. CHILLER OPERATING PANEL RLP REFRIGERANT LIQUID PUMPOUT � PRESSURE TAPPING IN CHILLER BARREL DIFF DIFFUSER G GAS DPT DIFFERENTIAL PRESSURE TRANSMITTER art— QF Y -TYPE STRAINER W/2 -1/2" FIRE HOSE CONNECTION DA DIRECT ACTING GLOBE VALVE DG DOOR GRILLE PS PRESSURE SWITCH - OS & Y (GATE VALVE) DN DOWN J DWG DRAWING �� PET COCK OR GATE DUCTWORK DB DRY BULB DGP DATA GATHERING PANEL = PIPE GUIDE MVD MANUAL VOLUME DAMPER EA EACH < PIPE ANCHOR FID FIRE DAMPER EP ELECTRIC - PNEUMATIC SWITCH ELEC ELECTRICAL � PLUG VALVE � SD SMOKE DAMPER EL ELEVATION � EQ EQUAL PRESSURE GAUGE � gp I BACKDRAFT DAMPER EAT ENTERING AIR TEMPERATURE PRESSURE REDUCING VALVE MOD EWT ENTERING WATER TEMPERATURE MOTOR OPERATED DAMPER EXH EXHAUST PRV PRESSURE REDUCING VALVE STATION E/A EXHAUST AIR � FD SD EF EXHAUST FAN � COMBINATION FIRE /SMOKE DAMPER ESP EXTERNAL STATIC PRESSURE PRESSURE RELIEF VALVE PRIMARY � FICE FLOW TEELEMENT C FOR CFM CUBIC FEET PER MINUTE FCU FAN COIL UNIT (OR ) FPM FEET PER MINUTE PRIMARY FLOW ELEMENT (VENTURI, � CAPPED END H FD FIRE DAMPER � FLOW TUBE) ROUND DUCT FC FLEXIBLE CONNECTION FM FLOWMEfER MAGNETIC FLOW METER �'�' —► UNDERCUT DOOR GPM GALLONS PER MINUTE — � SOLENOID VALVE IR INFRARED HEATER SECTION SYMBOL TEE DOWN SECTION No. KW KILOWATT G � TEE UP SHEET WHERE SHOWN LVG LEAVING LAT LEAVING AIR TEMPERATURE SUPPLY OR PRECONDITIONED OUTSIDE AIR DUCT LWT LEAVING WATER TEMPERATURE THERMOMETER LF LINEAR FEET � FLOW CONTROL VALVE RETURN OR EXHAUST AIRDUCT M/A MAKE —UP AIR T � INTERNALLY LINED DUCTWORK MVD MANUAL VOLUME DAMPER THERMOMETER WELL SIZES GIVEN ARE CLEAR INSIDE DIMENSIONS) MAX. MAXIMUM MECH MECHANICAL TAP IN VANED ELBOW F MER MECHANICAL EQUIPMENT ROOM MOD MOTOR OPERATED DAMPER' --Fhb UNION MOV MOTOR OPERATED VALVE MBH THOUSAND BRITISH THERMAL � 2 —WAY AUTOMATIC CONTROL VALVE UNITS PER HOUR PR RADIUS ELBOW NPSH NET POSITIVE SUCTION HEAD 3 —WAY AUTOMATIC CONTROL VALVE 1.5Dia. NC NOISE CRITERIA � ANGLE VALVE E TYPE NIC NOT IN CONTRACT A 12x9 SIZE OPNG OPENING � AUTOMATIC AIR VENT (AAV) CFM AIR QUANTITY OBD OPPOSED BLADE DAMPER 0/A OUTSIDE AIR �— BALANCING VALVE � CEILING DIFFUSER, -4 -WAY OSA OUTSIDE SUPPLY AIR ,�, UNLESS SHOWN OTHERWISE OIP OPENING IN PARTION ABOVE CEILING ��' BALL JOINT O THERMOSTAT PE PNEUMATIC - ELECTRIC SWITCH —F�— BALL VALVE D PSI POUNDS PER SQUARE INCH NEW DUCTWORK BASKET STRAINER RISE IN DUCT IN THE QTY. QUANTITY ` DIRECTION OF AIRFLOW QF QUICK FILL DROP IN DUCT IN THE Y -TYPE STRAINER WITH D DIRECTION OF AIRFLOW R/A RETURN AIR HOSE BIBS VALVE RG RETURN GRILLE FLEXIBLE CONNECTION RR RETURN REGISTER 7 PIPE CAP NCH TAKE-OFF - RPM REVOLUTIONS PER MINUTE W /MVD C RM ROOM CHECK VALVE S/D SMOKE DAMPER COMBINATION PRIMARY FLOW SMOKE DETECTOR SD SPLITTER DAMPER v ELEMENT &BALANCING VALVE SP STATIC PRESSURE � REDUCER � CONCENTRIC REDUCER S/A SUPPLY AIR �— DIRECTION OF FLOW IN DUCT OR PIPE SF SUPPLY FAN �� DRAIN VALVE (GATE VALVE SG SUPPLY GRILLE WITH HOSE COUPLING) � DUCT TRANSITION B SR SUPPLY REGISTER �— ECCENTRIC REDUCER TP TOTAL PRESSURE NOTES: TG TRANSFER GRILLE o--I ELBOW UP NP TYPICAL 1. THIS IS A MASTER SHEET: FOR SYMBOLS APPLICABLE TO THIS UH UNIT HEATER C� ELBOW DOWN PROJECT REFER TO THE DRAWINGS. 2. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR ACTUAL LOCATION VAV VARIABLE AIR VOLUME EXPANSION LOOP OF ALL AIR DISTRIBUTION DEVICES AND ACCESS PANELS. A 2W, 3W 2 -WAY, 3 -WAY, ETC. FLANGED PIPE END 3. FOR CLARITY NOT ALL LINED DUCTWORK HAS BEEN IDENTIFIED WITH THE WB WET BULB TEMPERATURE, OF APPROPRIATE SYMBOL. REFER TO PROJECT SPECIFICATIOS WP WORKING PRESSURE FLEXIBLE PIPE CONNECTION FOR DISTRIBUTION DUCTWORK RECEIVING LINING. (WITH CONTROL RODS) 4. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. 1 2 3 4 5 6 7 8 9 10 11 12 D /3\ 13 14 15 16 17 18 13 1 14 15 16 17 10 [41,11 0) 1 . IN, L�1 NATIONAL CITY (ENTER P.O. BOX 70M INDIANAQOLiS.IN 46207 (317) 63fr1600 L I IN I i w F-9 F THE CONR ICOMPANY im uaomxogmmn Satte5l0 Aluw Bad. EL 53199 (905153204ii �q O w H rn I - p Alrl�' ALVAR]BZ AiaTI9 lPAR1'N 16RS ARCHIUCTIM - BNGINBSRING PLANNING - INTERIOR DMGN M1.01 OF 5960 S.W. 57TH AVE. MIAMI, FLORIDA 33143 TEL (305) 666 -5474 FAX (305) 666 -4994 EAA 0002416 EB 0002354 MARIO H, GUTIERREZ, P.E FL MECHANICAL ENGINEER REG. NO. 0019687 ' D-":' , 1;0. 1 '.1" V) •_ „^,J�Yt �i ' ISSUE DATE -o -o .cq : = REVISION DATE c ' P A "id mc. 12 -10 -96 3 02 EVISION -12 -97 - •: . 0 - Z 7 04 -14 -97 W - B:CL .m _Q CADD FILE NAME M101 -RT DRAWING TITLE HVAC - LEGEND SHEET NUMBER A M1.01 OF