12-86 4OF7-125i
i
i
i
}
TERMINATE
LBELOW ID ROOF CAPF W/
n
1
I
271
I
r c�
IJI
�I
ice■
one ■
ice■
io■
io■
r
r�
U
r
WCO
54CD-f
e 1
or
(CONTINUED COLECTION ISOMETRIC 'f ,T
3 4 5 6 9 10. 'it 12 13
VENTED CAP
TERMINATE
BELOW ROOF W/
eVENTED CAP
3B _ 1 4" V.T.R.
-__I I L
- rJ L n d6
EQ IPT � RM.
DRN.TYPr INTERFACE j
2. I
I
r ,11
TERMINATE TERMINATE (
BELOW ROOF W/ gVaD W/ r i 3' V.T.R. r I I UMP DRAIN
VENTED CAP I� 13'V.T.R. s J I L I)
J IL r 4 ° 12• 1 -1�r CAP FOR 'NIKE7
tiL r3' \ r '^ I �" r I I REQUIREMENTS
MP DRAIN —~ �.� ti r r r 1 y
4'
RED. r 3" i 1
1 I 2' I RED. Co 1 4'
r I 1 s 31
% I r 4' 1 L
TRAP PRIMER- r 1 r EQ IPT
DRAIN.F.) co
I I VICE 1
I I YPF I
I U1 I
I I I
3' I I r 13' 4.
I 4' I r
r i r
U
I�
4
C.> I, ° 1-p - Y 4' CAP FOR PROPOSED 'NIKE'
I I I RESTI�OOM COORDINATE
WITH NIK REQUIREMENTS.
r
3'I 47
I r 4•
I
4• Cp
r 1 127
rI I '
3' I 45 DN.
I 4• I I
r 4' r 4'
c WCO ° WCO v WCO
1 wco 41
WCO WCO WCO 41
r 41 41 41
WCO WCO S
co
�S
2 3 4 5
OFN NE7 art (NOT USED)
f; V.T.R.
TERMINATE -� I L
BEIOW ROOF W/
VENTED CAP I
I
L'
r I
�r I
I
r I�
I �
n
I �
� 1
r
6"
0
U
WCO
4' V.T.R.
Y
TERMINATE tr I
BELOW ROOF W/ I TERMINATE 1r
VENTED CAP -� I VVENai D ROOF W/
4' V.T.R J L
VENTED CAP�n
I I
I I
I �I
I
i
r �
I,
2' 4
� � I
-e� I
r � ll I
I r FROM 'NIKE' SHOWERS
I
j " 'NIKE' REST ROOMS
1 1
_ I
I
I
I
I 4'
/J
cA
47 r FROM "NIKE' SHOWERS
i
r I
r WRAP AROUND COLUMN
I - MINIMUM 45�
I
I
I SYSTEM INDICATED ABOVE GRADE THIS DIAGRAM
do ON PLANS ARE ANTICIPATED AND FOR SLEEVE
r �1 4• COORDINATION ONLY, PIPING IS N.I.C. THIS PHASE
OF CONSTRUCTION; PROVIDE SLEEVES AND
3' OPEMIMGS WHERE RERQUIRED PER "NIKE'
REQUIREMENTS.
WCO '` I I WCO
WCO I
I
4'
CAP FOR PROPOSED
"NIKE' SYSTEM
J I � V.T.R.
I
1
I .J j � • V.T.R.
L�� I
11 � 11 JIL4' V.T.R.
I
I r IT J
I 14• ���,
I I
I I
I k I
V+ I I A
1 I
I
■ I � I
•� I C
4' I I
4.��J
6
"g.
12 13 Na7 Na7 16
(NOT USED) (NOT USED) (NOT USED) 'C eIr 'C'' &'D'
I
i
I
4' 1
WCO
fl'
I
I
U
I
I
Y "��FROM GREASE
INTERCEPTOR
S
17
• ^.
i
I
I
I�
1
4' 1
I O
CO
1 C1
W J
WCO
S
18
•C.
4"
1 WCO
1
14"
i
I 2■
I
U
1 I
I
' I
I c
14'
I �
I 4'
. I I
4
I I
e7
J I L V.T.R.
I
4' V.T.R. I
-JIL 1
r
r TERMINATE BELOW ROOF I
I �WffH VENTED CAP I
O
4'
e8
14 15
4' V.T. J I 4' V.T. R J L
Y L I
1 I
4' V.T.R J' L
I I
I I I
I 1 1
I
I I I
4
r' '
I
I
I � I
1 11 '�3' i - -�
I I I I I
I I I I
I I I I I
I I I
4' 1 1 I
I
I I �'I
I I I I
I 13' �
I I I I
I I -
Y
� j I
4' i r ') 4'
4' I f;
13■ I 47 4' C
I
3 I
I
I
I WCO I WCO
4'
iJ 4'
WCO
4'
1
_C 4o- -� CONNED TO TRAP BIBB BRANCH
4'
S
19
Woo
SANITARY &GREASE WASTE RISER DIAGRAMS
6'
16 17 18
J' L 'r V.T.R.
I
I J
I
I
o,
s" 1
YE FOR FUT
NT (TN -
I
c
i Er
J I L V.T.R.
1
I
I ,311
I
I
I
r,
I �
I
I�
9 6-GW 9A 'a7
N107
.�
out
J I L4' V.T.R.
I
U
I
I
I
I
I
I
I
I
I
I
I
Y
I
J I L4" V.T.R.
I L
TERMINATE BELOW ROOF
J _ 3' WITH VENTED CAP >
i
I
I I
I
\� I
I
I
I
I
I
I WRAP AROUND ONLY
I COLUMN 23
I
i
1 1
1 4.1
I FROM GREASE
1 INTERCEPTORS 7
WCO II
I
"�
4"
I
L '
0
U
0
U
D
U
BELOW ROOF
ED CAP
�r z3 ONLY
Jr
/-s /-s -s\ 20 _ 21 22 AS SHOWN
■CI ■y@ S
23 SIMILAR
■C.
(CONTINUED COLECTION ISOMETRIC 'C',TYP.)
A N.T.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
M %A J1 �,UJ �Lj
NATIONAL CITY CENTER
P.O. BOX 7033
-_ _INDUNAPOLIS, Iii 46207
(317) 636 -1600
L
RN
THE
COMRAS
COMPANY
1111 Lincoln Road Mall
Suite 510
Miami Beach, FL. 33139
(305) 532 -0433
J
q
I � o
w
a
F
KiF
G
F
AR=CTURE • ENG MMMNG
PLANNING - WTMOR DESIGN
5960 S.W. 57TH AVE.
MIAMI, FLORIDA 33143
I r
4' I
EAA
(
E
4• I
I
MARIO H. GUTIERREZ, P.E.
FL. MECHANICAL ENGINEER
REG. N0. 0019687
; I
LL1,
Y � �; v•
a
ISSUE DATE
I
I
�
y
I
6.
I
c
L'
REVISION DATE
I
Y
PRICING DOC.
12 -10 -96
'
A02-12-97
I y
CID
04 -14 -97
2" 4
137
.w
4�,1
I
'
WCO I
41
CO
Co
I
31
WCO
` 4'
1
CADD FILE NAME
�
4
1
WCO
1
Er
131,
-4'FD W BUCKET STRAINER
AND SEAL TRAP
•
S•1 ."
4'
1
_C 4o- -� CONNED TO TRAP BIBB BRANCH
4'
S
19
Woo
SANITARY &GREASE WASTE RISER DIAGRAMS
6'
16 17 18
J' L 'r V.T.R.
I
I J
I
I
o,
s" 1
YE FOR FUT
NT (TN -
I
c
i Er
J I L V.T.R.
1
I
I ,311
I
I
I
r,
I �
I
I�
9 6-GW 9A 'a7
N107
.�
out
J I L4' V.T.R.
I
U
I
I
I
I
I
I
I
I
I
I
I
Y
I
J I L4" V.T.R.
I L
TERMINATE BELOW ROOF
J _ 3' WITH VENTED CAP >
i
I
I I
I
\� I
I
I
I
I
I
I WRAP AROUND ONLY
I COLUMN 23
I
i
1 1
1 4.1
I FROM GREASE
1 INTERCEPTORS 7
WCO II
I
"�
4"
I
L '
0
U
0
U
D
U
BELOW ROOF
ED CAP
�r z3 ONLY
Jr
/-s /-s -s\ 20 _ 21 22 AS SHOWN
■CI ■y@ S
23 SIMILAR
■C.
(CONTINUED COLECTION ISOMETRIC 'C',TYP.)
A N.T.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
M %A J1 �,UJ �Lj
NATIONAL CITY CENTER
P.O. BOX 7033
-_ _INDUNAPOLIS, Iii 46207
(317) 636 -1600
L
RN
THE
COMRAS
COMPANY
1111 Lincoln Road Mall
Suite 510
Miami Beach, FL. 33139
(305) 532 -0433
J
q
I � o
w
a
F
KiF
G
F
AR=CTURE • ENG MMMNG
PLANNING - WTMOR DESIGN
5960 S.W. 57TH AVE.
MIAMI, FLORIDA 33143
TEL (305) 666 -5474
EAA
FAX (305) 666 -4994
0002416
EB 0002354
MARIO H. GUTIERREZ, P.E.
FL. MECHANICAL ENGINEER
REG. N0. 0019687
LL1,
Y � �; v•
a
ISSUE DATE
_C1111
c
- o�
-�
REVISION DATE
08-07-96
PRICING DOC.
12 -10 -96
A02-12-97
_ o
Z
04 -14 -97
.w
_ O
:Q
CADD FILE NAME
CP501 -RT
DRAWING TITLE
BLDG C PLUM DIAGRAMS
SHEET NUMBER
A
C -P5.01
OF