12-86 4OF7-0981 2 3 4 5 6 '7 8 0 10 11 12 t:j
REFER TO SHEET No. D -PE.03 FOR D -302
MROOF INFORMATION ON THIS AREA CORRIDOR
STORAGE
X.
UP TO 4" RD 5 y .1
_ 25 (790 SF) _ i
W. Z.l Z.2
WL UP TO 4" RD
24 (1630 SF) 9.4 r ,
- / ` - _ LOPE C ID 1 , (Z.3)
AD 6
CORRIDO 118" SLOPE BETWEEN JOISTS 858 ` / \ -
(1630 SF) (INSULATED) TYP. fVTR \i 02 8 FkR� / '
UP TO RD � 1/ 10.4
F WL UNDER JOISTS / CW K 10.1 - - - - ` II \ 2 5 \ �' BETWEEN J01 S` _ - )VE // ,( *) \ / 4"
6"RWL N. (INSULATED) 1iYP. CAPPED
4 "PUM ATION "B"\ CW
� � ,� - 10.3 /
I \ (2420 F) , " / - - �� /
10.2 7 ABV. CLG. _ � _
D JOISTS I+ 21 4"
s �\ / ,/ o , 11.3
10.8 \ 18 / / / \ O 3/4 CW ( *) CW
I \ CW \ \ , 8 '
/ �' , , 4 I \ + ABV. CL . / 6" RWL ( *) , \
\ / I \ \ / L 6" RWL + / / � ' 4A
' 6"RWL (3500SF) ` UP. TO RD / , / ( *) 4 "CW
11 12.1
(3192SF)
\ / \ .4 / / \�\\
\ I UNDER BM. � \ D 6" `
UP UP TO �j \� \ \ ,�' \, / /D 12.2
' \ I WL 6" RWL ENANT -K OFFSET AT / / \ / � \ / \ 3" VEN�
(4 40 F) CW I 3RD FL CLG
OFFSET AT 8 U / - 3
12.
3RD FL CLG I 1 11.9 \ / \ , 3 2" CD 5 (*
S 6" \ / / \ \ - - - - I - DER I ,\
- I - - - - - --f- - - \ — — 12.7
I S 2"C VENT
CW 9A 3" VE \ / Opp \\ \ / TENANT –L01
UP T ,
CW S I � / \ \�� qTA \\ '
' I \
J 131 \ /
is I 14
WL \ 4 V \
' I ' 4B RWL
/ 6 "RD �(471F) 5 / fi.4
e
38 / / \ /
I TAD \ \
HI I I I (780SF) /\ /
S 4" AN. I— — — 1 11 ®/ \ 6" R 927SF) \
IF-
13.9
I � 4L� I 4" WL DN. WL \ ° DRAIN UIPMENJ�2 ,
I 0 780 F /
2" CD ) 15 I ( j 3" ® 1 /4" /FT
-� - - - I - - - - - - - - - - - �/ S % 3" WASTE AND VENT. BELOW FLOOR I CAPPED VI ULIC 4" VTR
I!i 12 2" CW. DN.(BACKFLOW S
PREVENTION BYQUIP'T. ) UM
– —E�F-J
I I
I I I I L UP TO GD -8 3" SUMP DRAIN (5589 SF) '
19 3" (816SF) (TYP.) / \ /
I ' I
I II I
I
BRIDGE
BELOW
I I I I
F II I
I I
ABOVE CLG.
3" GD -3 ET-2) 3" (539SF)
X WL 3" RD i I I RWL 3" GD -4
22 (400SF) , 11 (714SF) -
II
E I I \ BRIDGE
' I I BELOW II I I L
' WL 8
_ _ - _ _ / _ _I _ , , I L 6" RD , 3" (939SF) I ' ABV.
13 (5357SF) CLG.
/ 6" RWL L 6" RD
AB /4" FT. (3862SF) I
-- 17.3 - - - - - - - - - - - - - / - - \- - - - - - -
\�
,� \ RWL 6 "RWL / ` 6" RD
D V I R �� 13 I (2719SF) RWL
'L
S I v I I I (3433SF) 11
- - S
-_ - - - I - - - - - - WL I / 6-VTR 19 4 "VTR T17 I I 6"VTR� 4 "VTR
23 3" (368SF) o` o S 4 "VTR o L S
3" 966SF
� \ �� 18 , 21 ( ) n 16
MI I 3"GD -9 3"GD -10 ! 3"GD -1
ABOVE FLOOR (208SF)J (371 SF) ABV.
- - --- r - I I I I 112 "GD -1A IFLR.
I (112SF)
II
I I
II
11 I I I I I
I I
B
Q R S S.1 T U V W x X.1 Y
15
`\ / `\ `\ 15.5
RWL 3"GD -7
20 (935SF \ /
13.5 \ \ / 16.5
\,
6RD (7181 SF)
RWL 3" \
(3 \ /
10
W
- -� (3
11A (899SF)
0
1 1 2
BLDG. C THIRD FLOOR PLAN
SCALE:1 /16 " =1' -0"
3
i
/ 6"® 1 /4 " /Ff / / \ \ I , / , / /
/
\ //
I 6"VTR 1 / \ . 55 SF \ , , / % I \ \ \
j � ( I / \ / GG
I
•3" GD -2
(371 SF)
2" GD -2A
(112SF)
Z
10
16
DD
/Z X
AA
11 12 13 14 15 16
17 I is
GENERAL NOTES:
1. ALL DRAINAGE PIPING 4" AND LARGER
SHALL BE SLOPED AT 118" PER FOOT
MINIMUM.
2. ALL DRAINAGE PIPING 3" AND SMALLER
SHALL -BE SLOPED AT 1/4" PER FOOT
MINIMUM.
3. ( *) COORDINATE WITH "NIKE"
REQUIREMENTS AND PARTITIONS
KEY PLAN
D
17 1 18
M I%AiL\�oUUJL
NATIONAL CITY CENTER
P.O. BOX 7033
INDIANAPOLIS, IN 46207
(317) 636 -1600
L
KI
i
11
H
Ifl,
[a
THE
COMRAS
COMPANY
1111 Lincoln Road Mall
Suite 510
Miami Reach, FL. 33139
(305) 532 -0433
r--
•
f,
f,
aRaflTECTVRa • aNCnrt�RU�rc
PLANNING •INTERIOR DESIGN
5960 S.W. 57TH AVE.
MIAMI, FLORIDA 33143
TEL (305) 666 -5474
FAX (305) 666 -4994
EAA 0002416
EB 0002354
REG. NO. 0019687
FL. MECHANICAL ENGINEER
MARIO H. GUTIERREZ, P.E.
D < r _�
ISSUt DATE
c _ REVISION DATE
08-07-96
PRICING DOC.
12 -10 -96
C; 102-12-97
Z &04 -14 -97
- U
:o
CADD FILE NAME
CP303 -RT
DRAWING TITLE
BLDG C 3rd FLOOR PLAN
SHEET NUMBER
0 F