12-86 4OF7-093M
L
K
i
I
H
G
F
E
1:11
C
rel
rwil
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
i
NATIONAL CITY CENTER
- P.O. BOX 7033
,/ -- INDIANAPOLIS, IN 46207
(317) 636 -1600
I I I I I I
I I I I
L.5 L.6
YMI N.l 0.3 0.6 0.9 P.2
---- -- 1004
zli/
937
- - - -
10.1
I
6
0
i DN. IN "AMC
I / PAR MON
' !
100
4" VENT �
I I I
I I I 7)11
I - D 11 I + I I
0 TO R° I
0
0
1C
L2_/
I I
I I I
D DESIGN OF THIS 1 0 GA
FOR DETAILED � G.7
AREA, SEE ENLARGED PLUMBING ° F H.3 \
. 7 , ' , I
PLAN ON SHEET B -P4.02 1 , I / ' t
L , e& g
16 H.5 I I 44 I
1 TO /
G. H . 7 � II
I.1 _ - - -I - - - - -� - - - - -I - - - - - - - �-
B� --401 I B -404 H. � 13.7 -- - � _ � � r
T1_1y L 1 TENAN -AMC 13'3 3" G. GD15 TO ' -
6
\� 6" UP UP
I
TO RD 12
I ST -1 / - ---�
\-erVENT Ga W I COORDINATE W/ w AMC I
DNff_
I
REQ'TS. � I
I
UP TO D14
\ , \ 1/4 w /FT MIN. BL , \ \ / 3" PTO GD13 3" R TO GD13A I
w 1
3" UP TO GD13'
-Er Up
14.7
° m o 8" DN. R 9L / 6w RWL \ �6" UP/ ' \
' I 8A ' \ TO RD ' �-5' RD '
3„ / // \ /\ 1 (1630 SF) I I
I 6" ®1 /T /FT MIN. I I n �„ L \, I T� _ I 1
_ - - - - - _ - - - - - - } b 14.9 S 75 � / \ \ - - - - 3w(140 SF) 3"(468 SF) -
15 - ° -� I 4 � 7 / \ 6675 SF) 6 / _ \_ - - - -
15.1
P \- \`
° — TO RD \ TO RD � ' \ L 3" RD I I
o / w
o COORDINATE W/ I AMC" ' ' \ I , L �P TD' 15 (742SF)
REQTS. \ 767 SF) 3 ' / B ' IT
4 "RD WL r - -
(230 SF) 16 II
FOR DETAILED DESIGN OF THIS ° _ 1 \ \ - S I '
AREA, SEE ENLARGED PLUMBING , _ 6" VENT I
PLAN ON SHEET B -P4.02 ° ' ' ' I ��
&
I-Er VENT G4 z \
\ \�\ � 16.E
I I J °- - I- - - -
- - o - - - - - - -
WASTE &VTR.
`I S - B I I I
I I I
°° - - - - - -
® I 17.7 1 4 7VTR
TO RD RWL
4" VENT S 6" UPe I
o
�
CAPPED VICTAULIC
2"CW DN (BACKFLOW
08 -07 -96
PRICING DOC.
PREVENTION BY
0 04 -14 -97
1 EQUIP'T MFR.
o
13
0
TRAP PRIMER
I
DRAWING TITLE
BLDG B 4th FLOOR PLAN
2°fQUIP. -Rk- - - - - - - - - - - -
DRAIN (W.)
3 "WASTE & VTR. S I /
B3 �C
17.3
GW ,
6" RD RWL 6"RD ' L 6"VTR B2
(5240 SF) (
4000 SF) 12
- - - - - 12 - - - - - - - - - - - - - - - - - - - I GW
- VTR I I ,
� � I
6„ 1 I I ' 63 i 6 DRAIN (TYP. 4 "� RIfVL 4 SF)
�� RWL , , �� 6" UP RWL I 3 (5360 SF) I I
T- I I I TO RD e TO RD e I WL g 13 - - 1 •6 - - -
I S " I - - - - - - - I I 4 VENT I $
I I e I I - - - - - - - - -t- �r ( _ I 0�-- -4 VTR I I I I -
19 v ST B3 B1 - - - - - - - - - - - - -
2 0 I
1(692S GD -4-/ I L�GD-6 GD -7 GD -8 I I
3"(692 SF) I ILGD-5 3"(173 SF) 3"(473 SF) 3"(473 SF) 3"(218 SF) 1
I I I I I I I I I I
I I II I I II
I I I I I I I
A A.1 B C D E F G H I J K K.1 L M N 0 P Q R, S S.1
1 1 2
BLDG. B FOURTH FLOOR PLAN
SCALE:1 /16 " =1' -0"
41
10 1 11 1 12
13 I 14
GENERAL NOTES:
1. ALL DRAINAGE PIPING 4" AND LARGER SHALL
BE SLOPED AT 118" PER FOOT MINIMUM.
2. ALL DRAINAGE PIPING 3" AND SMALLER SHALL
BE SLOPED AT 1/4" PER FOOT MINIMUM
KEY PLAN
15 1 16 1 17
B
THE
C�OMRAS
COMPANY
1 111 Lincoln Road Mall
Suite 510
Miami Beach, FL. 33139
(305) 532 -0433
0
x
E
7
O
v�
ARCHITECTURE • ENGINEERING
PLANNING - INTERIOR DESIGN
5960 S.W. 57TH AVE.
MIAMI, FLORIDA 33143
TEL (305) 666 -5474
FAX (305) 666 -4994
AA 0002416
EB 0002354
MARIO H. GUTIERREZ, P.E.
FL. MECHANICAL ENGINEER
REG. N0. 0019687
J °
=
-
-
-
-o
-z
- U
. w
ISSUE DATE
REVISION DATE
08 -07 -96
PRICING DOC.
12 -10 -96
0 04 -14 -97
CADD FILE NAME
BP304 -RT
DRAWING TITLE
BLDG B 4th FLOOR PLAN
SHEET NUMBER
A
B-P3,04
18 I I OF