12-86 4OF7-0851 2 3 4 5 6 7 8 9 10
A A.1 B B.8 C D D.8 E E.6 F.2 F.3 G.2 G.8 H.l H.2 H.8 I.5 I.7 I.8 J.2 J.6
M
I
I CW I I I I I I
A -303
1 S RESID NTIAL
_ \,4 j T H V ST. ELEV TORS I i i
- - - -
4 W /1/2" A -30 EL -A1 EL -A2 - - - - - - -I - ST -A2 - - - - - - - - - - - -
L1.1 RESEAL � H _ , , � I I I I ' �
3/4" H.B. A -301 I 'I
O I I I
WL ,' RWL (260 SF) I LOBBY
1/OFFSET ® 3RDFL CLG i DN
I
UP -FOR DETAILED DESIGN OF THIS
T -Al pN I I AREA, SEE ENLARGED PLUMBING I I -
2 - _ _ - PLAN ON SHEETS A -P4.02 - _ _ - _
-I - - -
WL I ❑ , WL Er (4675 SF)
e3"(175 SF)UP RWL 4" 1750 SF
2 ( )
K° RWL 4" RWL DN -
e2 (1925 SF) ®0 � "SAN S
VENT e '
3 _4VENT UP
3.1 A .2nd F1 R. CLG o I /�s"VENT UP 7 (3R4 SF) ,
I I ❑ I I I Q '
_ TVENT DN.
I
J - $ ® I 1 1 CI L]�
I ®1/41/17, ® I I I STUB -OUT I I
4600 5F) ABO Ei �AN STACK FOR AMC" VENT I,
6" RWL DN. ' RD. FL} CLG. E" RWL (4600 SF) 5WL ' I S I WL (6050 SF , I I I I e I
SAN. S I'
3 4" RWL UP - VENT U7 I I Z" CD CD '
(1450 SF)- - ❑ - - - - - - - - - ' - �- - - - - - -
5 ® � S -
�CD Cp 7 Y 22 ,SAN STACK W/ ' OFFSET ABOVE
(STUB -OUT &CAP 3RD FLOOR CLG.
❑ FOR FUTURE ABOVE,
I _ 0 2ND FL CLG. PER I II
0 ❑ ' "AMC" REQUIREMENT ' A -305 I ,
' I TENANT -AM I I 1 I
ABV. �CLGI DN
i I
LW R.R. I 4"RWL UP RWL
RWL TRWL UP ' ' (1525SF) 'a7
1 I I
N (275 SF) _ -- 0 ° I I " I'
6 - - - - - - WL - WL - - ' - - - ' - - - , - - - ; - - - R L 4 RWL I 1 �t CW RE- FL
EAL DN
1 ® DN I $" I 1 1425 SF TO BELOW
ST -A 5 ,l � D -}- (
,1 3 4 H
600SF} �i�= _ _ _ _ - - _ _ - - - - - - I WASTE & _7_�
4" TRWL �12840SQ ,DN. ABOVE 3RD FL C G. ' ' CW " A -307 I
H 6.2 e1 SERVICE 8
- 0 ® - - GW GW I ' FUEL TANK RI E , 4 "FD W/
1 CD CD 0 - 1 i S*VE & ' I I A- RE -SEAL
3, ' ' GW WL 3"CW RIS FROM 1ST FL DN DN S 8A 2" RISE Q 8 ELENOID
ABOVE 2ND FLO R CEILING ' 1A FROM BELOW I I e8 PUMP RO M. PER "AMC" '
7 8" ®1/8" /FT (8 40SF) ' 16685 SF - -o ] REQUIREM NTS `'
I 3" RWL FROM ABOVE (520 SF) I ' ' ' ' ' WASH RING
I
' I \ FOR DETAILED �ESIGN OF THIS I I _ CD ' 2-CD RISER I
AREA, SEE ENLARGED PLUMBING FROM ABOVE
G PLAN ON SHEET A -P4.02 -
ABOVE 3RD FL CL . L. +32' -0
/ ABOVE 2ND FLOOR CEILING ' I I ' � I i
\ I I I I
' I ' 8" ®1 /8" /FT (7120 SF) I
' 6"RWL FROM I I I ( UP
ABOVE (7720 S - - - I - I - -�-- - - - ' - - CD - - - - - ' - 1
gr
Elf
C \ \ Q O +30'4-\
E -
F
p
�'I `l\' /) \ \� /'/ 1 1 /4 7 CW C
T EL-A5
\ 16"WIDE TRENCH I i� ' EL -A6\
DRAIN
(550 SF)�� --
I (550-SF) 22 L WL EL -A7
WH 2900 SF UPI 21 \
36 SIF DN - _
- S GW - - I - - -� I EL . +32'-
I I I ' � 3 I I ABOVE CLG. I' j G
WL 3"RWL 'I n'� J (7 SF) 3" ®1/
14 (700 SF ) ,
1 1 I I 2"CD FROM CD 2" CD (1090 SF� I�� 9 4 "f
' AB pV.E 10 / 700 SF _ I / /) (tE
e G , )
I
CD I / , W // N
� � 8" RWL
I I I 1 1 I 10 ' CD �
(7350SF - - - - -
4" RWL , /
/
I ABV. 3RD. FL CLG. �� � VENT � (1090 SF)
I i
/ FL 2ND. 4 "SAN FROM WL RWL ' /// + -311
1 , FL CLG. ABOVE /_S ' 16
9A A�
e UNDER BEAM / / , I
-4- - - - - - -�- - - - - -�� - - - ,- - - -
4"
WL
17
G.4 I I
CN
� 3„ 4"
G.1 \,� F (2
z F.7 3 1---_(225
H.4 '
\ H.5
G.3 H.7 `
B
� I I p \ 3 ®0 SF
13.8 / ' / H.
G.6 ,
\ / 30AD
° I.2 (350SF)
CD \ /
I °
BLDG. A THIRD FLOOR PLUMBING PLAN
Ln I n I
A SCALE:1 /16 =1 0 \ , \ , h-3
/
r 14.7 / �� �, ,
Ln
U
r14- 9)
w
0
1 2 3 4 5 6 7 8 9 10
2
11
i
11"
111
iz I is
14 15 16
I ILI
I
I
ABO CLG.
I GW _ - - _ __
' �J��I�� - - - � CO
-SAN A -316
I� G ANITOF�, o I
WH BLW. FL
1
I I u I u
I
KEY PLAN
W/z A )D
A- 31
CORRIDOR
I
ROUTE 3 4 "CW TO IN} LINE WATER
\ I HEATER 3(4-2) W/ 1, /2"HW & CW
TO P-8
Li
I
1 i _
i
I
I
I
0 0 0 0 0 0 0 I
0
3'
6" 0118" ,11FT - -� -�- -
(2525SF)
i
i
4" AD. \ I I I
(510 SF) I
6" (600 SF) WL
27
' %4 (1410 SF) WL
I II I I I i I
O - -
1
AD U P TO/ D.-
I
I
ABOVE CLG. '
CONTD. SHEET B -P3.03
o
1
12 13 14
II I (140 SF) I
I I �
I I
15
17 I is
10110111111111111111110y lU111
I"L:I1
INATIONAL CITY CENTER
P.O. BOX 7033
INDIANAPOLIS, IN 46207
(317) 636 -1600
K
ki
I
I-owl
THIS _j
COMRAS
COMPANY
1111 Lincoln Road Mall
Suite 510
Miami Beach, FL. 33139
(305) 532 -0433
A
0
�-i
Cs�
AILVARIE L
AND
PPLLAN�NINC�TERRIIOR DESIGIGN
I _ 5960 S.W. 57TH AVE.
MIAMI, FLORIDA 33143
\ TEL (305) 666-5474
l i FAX (305) 666-4994
- - - / ' ' ' i \ �\� AA 0002416
I \ EB 0002354
MARIO H. GUTIERREZ, P.E.
FL. MECHANICAL ENGINEER
I I \ \ \ REG. N0. 0019687
3"VENT 5 3
6" G5 , "SAN.
2" CD 1 I ' \ � -
ISSUE DATE
_ REVISION DATE
A -317 " \ :� 08 -07 -96
TENA� PRICING DOC.
I ` _ 12 -10 -96
I ` 02 -12 -97
EiRWL L ' ' `, : z 04 -14 -97
(4260 SF) 29 I _
w 06 -18 -97
. O
Q
' - CADD FILE NAME
I _!
AP303 -RT
G DRAWING TITLE
' I BLDG A 3rd FLOOR PLAN
GW3 I GW4 I G V5
I SHEET NUMBER
A
II I
A -P3.03
1
16 17 18 of